| 1 | S & F in repair stainless steel CP Rod 25mm dia with 2mm thick, including wooden side caps, brackets, and rings @ 120mm c to c, complete all asspecified and directed. |
| 2 | Taking downrain water pipes (CI,AC,PVC etc) set in any cement mortor of any diameter incl bends Note rate quoted up to G+8 bldg including scaffolding. |
| 3 | S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete. Note rate quoted up to G+8 bldg including scaffolding. |
| 4 | S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore complete. Note rate quoted up to G+8 bldg including scaffolding. |
| 5 | S & F 100 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed. Note rate quoted up to G+8 bldg including scaffolding. |
| 6 | S & F 75 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed. Note rate quoted up to G+8 bldg including scaffolding. |
| 7 | Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) complete all as specified. |
| 8 | M&L for Plain, solid, straight chowkats and frames made of 2nd class hard wood, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed,making good , complete all as specified and as directed by Engineer-in-Charge. |
| 9 | S&F for 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 10 | M&L for 35 mm thick 2nd class hard wood glazed and skelton door shutter, factory made,open rebated and prepared to receiveglass/guage etc. (without sash bar) edge of frames plain, chamfered or rounded, fitted with cut & mitred beads for securing glass/guage etc size of member as specified in SSR Part I Section 8 clause 20(a) and fixed to chowkat, complete all as specified. |
| 11 | M&L for 35 mm thick 2nd class hard wood glazed and skelton door shutter, factory made,open rebated and prepared to receiveglass/guage etc. (without sash bar) edge of frames plain, chamfered or rounded, fitted with cut & mitred beads for securing glass/guage etc size of member as specified in SSR Part I Section 8 clause 20(b) and fixed to chowkat, complete all as specified. |
| 12 | S&F150mm long extruded alumiunium alloy handle fabricated type anodized (D type). |
| 13 | S&F 100 mm long(size)butt hinges medium weight, cold rolled,mild steel, complete all as specified(Fixing included in item 43 here-in-before). |
| 14 | S&F for 150 mm size aluminium, anodised barrel tower bolts of extruded section and fixed to shutter complete. |
| 15 | S&F for MS300mm size,door springtype rat tail rod pattern springs including roller and roller plate complete. |
| 16 | S&F for 100 mmsize longmortice lock vertical type ,4 levers with key in duplicate, brass body with brass two nos handle fixed in shutters with screw complete all as specified. |
| 17 | Supply & fix two legged aluminium floor door stopper with rubber shoe 140mm long complerte all as specified and directed by Engineer-in-Charge. |
| 18 | S&F for galvanized stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm dia fixed with stainless steel wire staples including beading complete all as specified and as directed . |
| 19 | Hacking out old brokenglass of any thickness size quality or description frame wooden frames /Aluminium frame fixed with wooden beads/aluminium beads and M&L 5.5 mmthick sheet galss ordinary quality and glazing with wooden bead/aluminium beads, complete all as specified. |
| 20 | Anodised aluminium powder coated sliding windows, window shutters and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as locking system, suitable handle (1 no.)complete all as specified and as directed by Engineer-in- charge. |
| 21 | S&F powder coated Anodiesed aluminium door shutters, aluminium section weighing 0.55 Kg/m incl. necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each doors,Brass 2 lever mortice lock verticle type size 100mm, hinges, anodiesed aluminium snap beading screw withetc. |
| 22 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). → Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 23 | S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed. |
| 24 | Taking down chowkhat or frame not exceeding 1.5 Sqm eachwith shutter (without taking off shutter from the frame) |
| 25 | S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded Complete all Specified and directed. |
| 26 | All as per item Srl item No 25 above but without glazing bars. |
| 27 | S&F for Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165. |
| 28 | Demolition of cement concrete(Un reinforced) in ground floors n.exc 15cm thick (above or below grnd level) complete all as specified. |
| 29 | M & L for 75mm thick cement concrete 1:3:6type C2(using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished fair and even without using extra cement, complete all as specified. |
| 30 | M&L for PCC( 1:3:6) type C-2 using 20mm graded stoneas in padding on roof correction of slope and roof kerbs all as specified and directed. |
| 31 | M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent Repair Polymer including taking down existing roof treatment of any type including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified land as directed.Note: The application shall be executed on any type of surface and on horizontal/Vertical areas. |
| 32 | M&L providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary [coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge.Notes for item Nos 32: (a) The work shall be executed through authorised applicator of manufacturer only.(b) Authrised Applicator shall be approved by GE before starting of work.(c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.Engineer-in-Charge shall deface the original purchase vouchers.(d) MOU with authorized applicator will be submitted by contractor within 7 days after opening of Financial Bid.(d) A guarantee amount of 2.5% of contract of work done for item Nos 32 of BOQ will be retained for 5 years of the completion of work. |
| 33 | Taking up or down steel tubing 15 mm bore, and connections, including cleaning for re-fixing or removal to store in repairscomplete all as specified. |
| 34 | S & F 15 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairscomplete all as specified. |
| 35 | Fixing only 15 mm water tubes, any grade, to walls and ceilings or laying in floorsin repairscomplete all as specified. |
| 36 | Taking up or down steel tubing 20 mm bore, and connections, including cleaning for re-fixing or removal to store in repairscomplete all as specified. |
| 37 | S & F 20 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairscomplete all as specified. |
| 38 | Fixing only 20 mm water tubes, any grade, to walls and ceilings or laying in floorsin repairscomplete all as specified. |
| 39 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etcComplete all as specified. |
| 40 | M&L for brick work with sub class \"B\" bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1 : 4complete all as specified. |
| 41 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete. |
| 42 | M & L for Non skid 600x600x8 to 8-10mm thick coloured ceramic tiles as in floor over hacking surface of existing floor on 15mm thick screed bed in CM 1:6 including pointing in coloured cement to match the shade of tilesincluding cutting of existing door shutter at required height. complete all asspecified directed by Engr-in-Charge, and approved by GE. |
| 43 | M&L for coloured Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tilesnot exceeding 0.36 sqm, in floors etc. set and jointed in neat c ement slurry and pointed in white or coloured cement to match rendering 15mm thick cement mortar in CM 1:4 ,complete all as specified and directedby Engr-in-Charge. |
| 44 | All as per item No 43 above but10mm thick on rendering surface in CM 1:4 on vertical surfaces of wall as in skirting including taking down of existing skirting on walls complete all asspecified directed by Engr-in-Charge. |
| 45 | M& L for Non skid coloured ceramic tiles (300x300x)7 to 8mm thick in floors, etc, set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed for laying floor in CM 1:6complete all as specified and directedby Engineer in Charge, approved by GE. |
| 46 | M&L for coloured ceramic tiles (300x600mm)x7mm thick on vertical surfaces on skirting dados and risers to steps etc including rendering 10mm thick cement mortar in CM 1:4 ,complete all as specified and directedby Engr-in-Charge. |
| 47 | Schedule of Credit |