| 1 | M&L preparation of old surfaces of wall and applying one coat of distempering with 1st quality Acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved manufacturer\"s instruction complete all as specified and directed.Note :- Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Work shall be carried out using Roller/Brush as per manufacturer\"s instruction. Proper masking to be carried out before primer and paint application. |
| 2 | M&L preparation of wall surface and applying One coat water based premium acrylic smooth exterior emulsion(of approved colour) with PU & silicon additives, excellent dirt pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifications, Anti Algai properties in two coats @1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as specified and directed. |
| 3 | M&L preparation of old decorated plastered surfaces of walls and applying one coat of white wash, complete all as specified and as directed. |
| 4 | M&L preparation of old decorated plastered surfaces of ceiling and applying one coat of white wash, complete all as specified and as directed. |
| 5 | M&L Preparation old decorated plastered surfaces of wall and applying onecoat of cement base paint,using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and as per manufacturer\"s instruction complete all as specified and as directed. |
| 6 | M&L for complete removal of existing finishes, Preparation of surfaces of wall and applying two coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over priming coat of exterior primer applied @ 0.90 litre/ 10sqm, complete all as specified and as directed. |
| 7 | M&L preparation of old paintedwooden surfaces of any description over 10 cm width or girth and applyingone coat of synthetic enamel paint, complete all as specified and directed. |
| 8 | M&L preparation of old painted iron/steel surface of any description, over 10cm in with or girth and applying one coat of synthetic enamel roof paint complete all as specified and directed. |
| 9 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete including removing debries of the site complete all as specified and as directed. |
| 10 | M&L 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm& 5mm) mixed with and including water proofing compound in top layer as per manufacturer\"s instructions, finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
| 11 | Supply only Integral water proofing compound complete all as specified and directed. |
| 12 | M&L Rendering 15 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed. |
| 13 | M&L rendering 5 mm thick on ceiling or concrete Surfaces in cement mortar 1:3 finished even and smooth. (without using extra cement), complete all as specified and directed. |
| 14 | M&L preperation of new surfaces of ceilings and applying three coat of white wash,complete all as specified and as directed |
| 15 | M&L preparation of new wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specificationover new surface over 1 mm thick wall care putty,complete all as specified and directed. |
| 16 | M&L preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 17 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 18 | Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in concrete , brickwork, masonary etc. including taking out embedded portion and making good disturbed ground, complete all as specified and as directed. |
| 19 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 20 | Excavating in post holes (or similar holes) in soft/loose soil, each n exc 0.5 cu. m, getting out,and removing soil out of the site ,complete all as specified and as directed. |
| 21 | M&L providing plain cementconcrete type C-2, (1:3:6), (using 40 mm graded stone aggregate), Cement concrete in foundations, filling and mass concrete complete all as specified and directed. |
| 22 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including necessary prepration of surface and applying a coat of red oxide zinc chrome primercomplete all as specified and directed. |
| 23 | M&L TMT bar 10 mm diaand over, cut to length, bent to shape required, including cranking, hooking ends as in chain link fencing complete all as specified and as directed. |
| 24 | Supply only chain link MS galvanized fencing4mm dia and size as ordered, complete all as specified and as directed. |
| 25 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed. |
| 26 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed. |
| 27 | S&F Mild steel screw bolts 11 to 15mm dia. (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm and not exc 10cm long complete all as specified and directed. |
| 28 | M&L preparation new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 29 | Dismantling plain or corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 30 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 31 | S&F pre painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 32 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer, complete all as specified and as directed. |
| 33 | Demoliation of cement Concrete(unreinforced) in any position complete all as specified and as directed. |
| 34 | M&L 100mmthick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base of floor finished even and roughh complete all as specified and directed. |
| 35 | S&F 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including dismantling existing unserviceable paver block complete all as specified and directed. |
| 36 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top, including taking out old unserviceable membrane, bedding layerincluding PCC padding complete all as specified and directed:-(i) Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete and providing PCC 25mm thick average thickness Type B0 (using 20mm graded aggregate) as levelling course(ii)Rendering 10mm thick in CM (1:4) mixed with and including water proofing compound as per manufacture instructionon existing roof surface true to level after applying cement slurry @ 3Kg/Sqm over RCC slab when concrete is green(iii) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm.(iv) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.50 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 160gms per Sqm.Polymeric membrane shall be taken to a height of 30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(v) Two coats of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions. Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the endand sides of the polymeric membrane respectively and sealed alloverlaps and joints as per manufacturers instruction. |
| 37 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete including removing debries of the site, complete all as specified and as directed. |
| 38 | M&L rendering 15mm thick with cement mortar 1:4on fair faces of brick workin two layers (10mm and 5mm) sperately mixed with water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and faircomplete all as specified and directed. Note:- WPC shall be measured & paid separately |
| 39 | M&L Rendering 15 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed. |
| 40 | M&L rendering 5 mm thick on ceiling or concrete Surfaces in cement mortar 1:3 finished even and smooth. (without using extra cement), complete all as specified and directed. |
| 41 | Supply only Integral water proofing compound complete all as specified and directed. |
| 42 | Taking down Chowkhats or frames exc 1.5 sqm and not 4.00 sq. m each but with shutters (without taking off shutters from the frames) complete all as specified and as directed. |
| 43 | Taking down Chowkhats or frames not exc 1.5 sqm each but with shutters (without taking off shutters from the frames) complete all as specified and as directed. |
| 44 | S&F Pressed steel frames for doors with one or more rebates,1.25mm thk cold rolled mild steel sheet, size of frame 165 x 60mm including necessary fixing lugs, hinges, lock strike plate,etc., complete all as specified and as directed. |
| 45 | S&F Pressed steel frames for doors with one or more rebates,1.25mm thk cold rolled mild steel sheet, size of frame 105 x 60mm including necessary fixing lugs, hinges, lock strike plate,etc., complete all as specified and as directed. |
| 46 | M&L providing plain cementconcrete type B1, (1:2:4), (using 20 mm graded stone aggregate), as in fixing of hold fast, back filling of pressed steel door frame including necessary form work as required complete all as specified and directed. |
| 47 | S&F 2nd class hard wood plain solid, straight chowkats and frames , wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. |
| 48 | S&F anodised aluminium frame for doors, windows, ventileters with one or more rebates including joining cleat for fixing etc complete all as specified including powder coating above aluminium section.(minimum thickness of powder coating 50 micron) complete all as specified and directed. |
| 49 | S&F Powder coatedAnodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified complete all as specified and directedNote:- (i) Glass/Wire Guage shall be measured and paidseperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed(iii) Minimum thickness of powder coating 50 micron |
| 50 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples GI wire cloth with 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium frame work complete all as specified and directed. |
| 51 | S&F 30 mm thick factory made 2nd class hard wood glazed and skeleton shutters, open with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part -I. section 8, clause 8.24(b), complete all as specified and as directed. |
| 52 | S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 53 | S&F 35 mm thick factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part -I. section 8, clause 8.24(a), complete all as specified and as directed. |
| 54 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 55 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heatmoulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail;Paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cementcomplete all as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 56 | S&F 75mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified anddirected. |
| 57 | S&F 100mm MS butt hinges medium weight, complete all as specified and directed. |
| 58 | S&F 150 mm Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed. |
| 59 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed. |
| 60 | S&F 100mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed. |
| 61 | S&F 300mmlong Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed. |
| 62 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 63 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 64 | S&F 4mm thick plain sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in eachpane complete all as specified and as directed. |
| 65 | M&L Preparation of new or previously untreated wood surfaces of any description, over 10 cm width or girth, not otherwise described appling applying two coat of synthetic enamel paint overone coat of pink primer,complete all as specified and directed. |
| 66 | S&F in repair, 15mm bore Bib taps, fancy type, chromimum plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 67 | S&F in repair 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with in let ball valve float and handle, PVC flush pipe, complete all as specified and as directed. |
| 68 | S&F in repair,15mm bore Stop/Angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 69 | S&F in repair, vitreous China pedestal wash basin, white, flat back, size 550x400mmincluding brackets including cutting forand pinning in ends of brackets or erecting stand including, 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated,fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe, 32mm bore Waste fittings, brass, chromium plated with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, and 32mm bore PVC waste pipe 800mm long complete all as specified and as directed. |
| 70 | S&F PVC connection 15mm size with PTMT nuts, 450mm long complete all as specified and as directed. |
| 71 | M&L Loose filling with aggregates of gauge 40 to 80 mm, broken stone or boulders as in filling around transformers/Sub station complete all as specified and directed. |
| 72 | Demoliation Brickwork or stone/boulder masonry, built in cemnt mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified anddirected. |
| 73 | M&L brick work with sub class \"B\" bricks, old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 74 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debries/ rubbish from the site complete all as specified and directed. |
| 75 | M&LNon - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) of size 600 x 600mm in floors etc. set and jointed in cementitious tile adhesive and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 76 | M&L Glazed ceramic coloured tiles in vertical surfaces 300x600x7mm thick set and jointed in cementitious tile adhesive & jointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 77 | Demoliation of cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level)complete all as specified and as directed. |
| 78 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 79 | M&L Preparation of old wood surfaces of any description, over 10 cm width or girth, not otherwise described appling applying one coat of synthetic enamel paint,complete all as specified and directed.. |
| 80 | M&L preperation of new plastered surfaces of ceiling and applying three coat of white wash,complete all as specified and as directed |
| 81 | S&F Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; thickness of lath 1.25mm thick, erected in position as indicated, complete: push pull or manual type complete all as specified and directed. |
| 82 | S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 83 | ms |