| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (un-reinforced ) of any description & in any position not specifically provided for complete etc all as specified and as directed |
| 2 | Taking down chowkats or frames with shutters (without taking off shutter from frames) area not exc. 1.5 sqm eachincluding making good to match with adjoining surfaces etc,complete all as specified and as directed |
| 3 | Taking down chowkats or frames with shutters (without taking off shutter from frames) area exc. 1.5 Sqm but n exc 4.0 Sqm each including making good to match with adjoining surfacesetccomplete all as specified and as directed |
| 4 | Taking down shutter of any description area exc 1.00 Sqm but not exc 2.00 sqm each etc complete all as specified and as directed |
| 5 | Taking down cement plaster of any description hacking for key or raking out joint on old brick work / stone / concrete surface etc complete all as specified and as directed |
| 6 | Taking down shutter from frames of any description area exc 1.00 sqm & not exc 2.00 sqm each and refixng in same opening after easing / minor adjustment / repairs / side cutting / repairs etc complete all as specified and as directed Notes : Glass, wire cloth, butt hinges, Handle, tower bolt, sliding door bolt or any other mtrl reqd to fixing the door shutter, shall be measured and paid Sepeartely |
| 7 | Taking down Handle / Sliding door bolt/ Hasp & Staple/ Tower Bolt / piano hinges etc of any size and any description etc complete all as specified and as directed |
| 8 | M&L forPlain cement concrete(1:4:8) type D- 2 using40mm graded stone aggregate asin 75 mm thicksub base to flooing etc complete all as specified and as directed |
| 9 | M&L for cement concrete (1:2:4)type B-0 using 12.5 mm graded stone aggregatesas in25 mm thick sub base to flooring etc completeall as specified and as directed |
| 10 | M&L forPCC(1:3:6)type C-1using 20 mm graded stone aggregates as in 75 mm thick plinth protectionfinished even and smooth without using extra cementincluding joints filling with sealing compound Grade \"A\"complete all as specified and directed. |
| 11 | M& Lfor Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & includingscreed bed 15 mm thick cement mortar (1:6) including dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 12 | M& Lfor Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting /dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & includingbacking coat 10 mm thick cement mortar (1:3) including dismantlingwall tiling etc complete all as specified and as directed |
| 13 | M& L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over &includingscreed bed 15 mm thick cement mortar (1:6) including dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 14 | M & Lfor exterior grade, coloured glossyfinished pressed, rubber mouldedcement concrete designer chequered tiles of size 20cm x 20cm x 25mm thickset, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade of tiles over and including Screed bed 15mm thick cement mortar (1:6) including demolition of stone slab (Laid bedded and pointed in any mortar) etc complete all as specified and as directed |
| 15 | M&Lfor Glazed ceramic coloured tiles of size 300X450X7mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over &includingbacking coat 10 mm thick cement mortar (1:3) including dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 16 | M&L forGreen Marblestone slab 18 to 20mm thick(table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granit including grinding the edges half round and polishing over & including 15mm thick screed bed in cement mortar (1:6) including dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 17 | M&L for Pre-cast Cement concrete (1:3:6) type C-1using 20mm graded stone aggregates as in solid block masonary exc 10 cm in width and setting in CM 1:6including demolition of brick Work / Stone Masonry/PCC block masonry built in cementmortar of any description all as specified and directed. |
| 18 | M&L for Walling of Stone Masonry squared rubble, uncoursed well bonded, bedded and solidly hearted, built in CM 1:6 etc including demolition of brick Work / Stone Masonry/PCC block masonry built in cementmortar of any description all as specified and directed. |
| 19 | M&L for Key pointing to random or polygonal rubble, uncoursed or brought upto course in CM 1:4 includingraking out joints/ pointing to masonry in single detached joints for flashing, etc complete all as specified and as directed |
| 20 | M&L for Pre-cast cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM (1:6) etc including demolition of existing RCC Slab of any description and in any position etc complete all as specified and directed. |
| 21 | M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed |
| 22 | M&L for rendering5 mm thick cement mortar (1:3) on fair faces of concrete ceiling surface finished even and smooth without using extra cement etc complete all as specified and as directed |
| 23 | M&L for rendering 10 mm thick cement mortar (1:6) on fair faces of brick work or concrete surface finsihed even and smooth without using extra cement etc complete all as specified and as directed |
| 24 | M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surface and5 mm thick in CM 1:4 mixed with water proofing compound as per manufacture instruction finsihed even and smooth without using extra cement etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately |
| 25 | M&L for providing water proofing treatment to sunken portion of WCs, bathroom etc by applying cement slurry mixed with two component Elastomeric Acrylic based polymer modified cementitious composite compound coating as per following specification includingtaking down existing treatment with PCC all as specified & directed :- (i) First layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm.The layer will be allowed to air cure for 4 hours. |
| 26 | (ii)Second layer of slurry of cement @ 0.242 kg/sqm mixed with with Acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm.The layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(iii)20mm thick screed in cement mortar 1:3 mixed with liquid water proofing compound. (iv)Provide 40mm dia light grade GI spout at the lowest point with 30cm projection beyond the out face of the wall.(v) Cement concrete 1:5:10 type E-2 using 20mm granded brick aggregates as in sunken portion of WC.(Note : Treatment shall be tested for water ponding for7days) |
| 27 | M&L for Plain cement concrete(1:2:4) type B-0using 12.50mm graded stone aggregate as in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs/Chajjas and the like including weathering, slightly rounded or chamfered angles, necessary form workand throating all as specified & directed |
| 28 | M&L for water proofing treatment for RCC roof slab as per following specificationcomplete all as specified and directed :-(a) Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth(b) Screed bed 10 mm thick cement mortar (1:3) mixed with water proofing compound finished to even & smooth(c)Applying compatible primer @ 0.40 Litr/Sqm |
| 29 | (d) LayingAPP modified water proofing membrane as per IS 1654-2017/IS 16352-2017, 3mm thick and weighing not less than 3.80kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished overand torch applications of membrane with 100mm side overlap and 150mm end lap after necessary preparation of surface complete as per manufacturer\"s instructions(e) Applying a coat ofaluminum paint on top @ 0.10 litre/sqm(Note : WPC will be measured & paid seperately) |
| 30 | Supply only water proofing compound (Liquid), ISI marked,complete all as specified and as directed. |
| 31 | S&F Factory madepressed steel frame of profile size 125 X 60 mm for door with one ore more rebate, made of 1.25 mm thick M S sheet includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed |
| 32 | S&F Factory madepressed steel frame of profile size 105 X 60 mm for door with one ore more rebate, made of 1.25 mm thick M S sheet includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed |
| 33 | M&L for cement concrete(1:3:6)type C-1 using 20mm graded stone aggregateas in hold fast and fillingof pressed steel chowkatetc complete all as specified and as directed |
| 34 | M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Fe -E-165 etc complete all as specified and as directed |
| 35 | S&F Flush shutter35mm thicksolid core construction with decorative choice lamination on both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed |
| 36 | S & F in repairs Prelaminated particle board 18/19mm thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work,fixed in kitchen Cabinet or cupboardsall as specified & directed. |
| 37 | M&L for Plain fillets square, rectangular or triangular in section clean sawn , secured with nails or brads of second class hard wood fixed to cupboard shutter, not exc 3 sqcm cross section area, all as specified and directed. |
| 38 | S & F in repairs 40 mm dia cupboard knobs fixed with nut, screw and washer,Brasspolished complete all as specified and as directed. |
| 39 | S & F in repairs Continuous (piano) hinges 30 mm width of flap (when open), mild steel, bright finish or electro galvanised etc complete all as specified and as directed |
| 40 | S & FSolid PVC frame (Single Rebated) of size 50X47mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete as sepecified and directed (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
| 41 | S&F factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick (Stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on backface etc. complete all as specified and as directed. |
| 42 | S&F Powder Coated(minimum thickness of powder coating 50 micron) aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified and as directed |
| 43 | S&F Powder Coated(minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified complete all as specified etc. complete shall as specified and as directed |
| 44 | S&F sheet glass4mm thick ofordinary quality and glazing with oil putty or wooden beading to wooden frame or steel framein squares not exc 0.50 sqm in each pane complete all as specified and as directed |
| 45 | S&FFigured glass 4mm thick, pin head type and glazing with oil putty in squares in not exc 0.5 sq.m in each pane etc complete all as specified and as directed |
| 46 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staple etc complete all as secified and as directed |
| 47 | S&F Aluminium anodised towerbolt 200 mm long of extruded section etc complete all as specified and as directed |
| 48 | S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed |
| 49 | S&FButt hinges 100 mm size medium weight, stainless steeland fixed with screws etc complete all as specified and as directed |
| 50 | S&F Aluminium handle 150 mm size,cast type, anodised etc complete all as specified and as directed |
| 51 | S&FFloor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, 150 mm long plate,fixed in floor etc complete all as specified and as directed |
| 52 | S&F AluminiumHasp and staple 100 mm size, safety type, mild steel hinge pin including bolt to hinge plate and fixed with screws etc complete all as specified and as directed |
| 53 | S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mmetc complete all as specified and as directed |
| 54 | S&F in repairs European type Water Closet pedestal pattern(Ivory colour) with compatible soft closing seat cover of size 560X530X380mm with S Trap including connection to out going pipe, & seat cover and flushing pipe complete all as specified and as directed (Make PrayagCat No 4018 orof equlavent make specified in P S herein after)) |
| 55 | S & Fin repairsvitreous china wash hand basin, white flat back of size 550 x 400mmincluding GI bracket, waste fittingsbrass chromium plated with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, PVC waste pipe 75 cm long complete all as specified and directed. |
| 56 | S&F in repairsPVC dual type flushing cisrern valveless with flushing out valve low level of 10 Ltr capacity white with inlet ball valve, float, flushing bend & handle including brackets & connection to pipe etc including PVC connection 450 mm long with PTMT nuts complete all as specifiedand as directed. |
| 57 | S & Fin repairBib taplong body,brass chromium platedwith CP flange,screwed down for iron pipe 15mm dia all as specified and as directed. (Make : Prayag cat No-6808 Marcus seriesor equivalent make as specified in PS herein after) |
| 58 | S&F in repairswall mixer for mixing hot and cold water, Brass chromium plated,\"L\" Bend with Wall Flange (Provision For Over Head Shower) screwed down for iron pipe 15mm diaand fixed complete all as specified and directed (Make : Prayag cat No-6875 Marcus series of Prayag or equivalent make as specified in P S herein after) |
| 59 | S & F in repairs Centre hole wash Basin mixture without Pop up, brass chromium plated, screwed down for iron pipe 15mm diaall as specified and as directed.(Make : Cat No 6850 Marcus series of Prayag or equivalent make as specified in P S ) |
| 60 | S & F in repairsSink mixture with regular spout wall mounted, brass chromium plated fixedfor iron pipe 15mm dia all as specified and as directed.(Make : Prayag cat No 6855 Marcus series of Prayag or equivalent make as specified in P S herein after) |
| 61 | S & F in repairs Angle cockwith wall flangesbrasschromium paltedfixed to pipes 15mmdiacomplete all as specified and directed.(Make : Prayag cat No 6810 Marcus series or equivalent make as specified in P S herein after) |
| 62 | S&F in repairs Unbreakable wall mounted Glassshelf 500mm x 125mm complete all as specified and directed(Make : Prayag cat No BEA-45or equivalent make as specified in P S) |
| 63 | S&F in repairs Unbreakable corner Glass shelf 300mm size,Brass Bracket,complete all as specified and directed(Make : Prayag cat No BEA-44or equivalent make as specified in P S) |
| 64 | S&F in repairs Soap dish,brass chromium plated, fixed as per manufacturers instruction,complete all as specified and directed(Make : Prayag cat Part No BA-45or equivlaent make as specified in P S) |
| 65 | S&F in repairsoverhead shower ABS112mm diawith brass Arm 225mm long & flange including fixing to steel pipe 15mm diaor union complete all as specified and as directed. (Make : Prayag cat No BS-67 or equivalent make as specified in P S) |
| 66 | Supply and fix in repairbevelled edge mirror of size 600mm x 450 mm of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 67 | S&F in repairs PVC Mirror cabinet of size 400x500 mm with various compartment made for bath room complete all as specified and as directed. |
| 68 | S&F in repairs stainless steel plate rack made of 0.63mm thick S S sheet, size 800mm x 600mm x250mmcomplete all as specified and as directed |
| 69 | S&F in repairs Towel rack,Stainless steel glossyfinish complete all as specified and directed (Make : Prayag cat No BA-12Sor equivalent make as specified in P S) |
| 70 | S & F in repairs Towel rail 600mm long, stainless steel glossy finish complete all as specified and as directed. (Make : Prayag cat No-BA10S or equivalent make as specified in P S) |
| 71 | S&F in repairs Towel ring, Stainless steelglossy finish complete all as specified and directed (Make : Prayag cat No BA-02 or equivalent make as specified in P S ) |
| 72 | S & FCPVC pipes 20mm outer dia, SDR 11 & Plain CPVC SDR 11 fittings, concealed in walls/ ceiling or laying in floors including taking down existing GI/CPVC pipe line etc complete all as specified & directed (Notes : Quoted Rate deemed to be included for cutting grooves for concealing of pipes or cutting holes into stone maosonary wall including making good to match with adjoining surfacesetc complete) |
| 73 | S & FCPVC pipes 25mm outer dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors incl taking down existing GI/CPVC pipe line etc complete all as specified& directed |
| 74 | S&F in repairs Rotational moulded polythene water storage tank 1000 ltrs capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part Iincludingball float valves25 mm dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball etc complete all as specified and directed |
| 75 | S & F in repairsGun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe 25 mm dia boreincluding taking down old gate valve all as specified and as directed. |
| 76 | S&F in repairsPVC (SWR) multi floor trap with grating 75 mm dia bore outlet including jointing with solvent cement etc complete all as specified and as directed |
| 77 | S & FPVC (SWR)pipes 110 mm dia bore, single socketed in any length with rubber ring joint laid in trenchesor in floor etc includingdismantling of existing pipe and fittings etc complete all as specified and directed |
| 78 | S&F PVC (SWR) pipes 110 mm dia bore, single socketed in any length with rubber ring joint fixed to walls etc including dismantling of existing pipe and fittings etc complete all as specified and directed |
| 79 | S&FPVC (SWR)pipes 75 mmdia bore, single socketed in any length with rubber ring joint laid in trenches or in floors etc including dismantling of existing pipe line and fittings etc complete all as specified and directed |
| 80 | S&FPVC (SWR) pipes 75 mm dia bore, single socketed in any length with rubber ring joint fixed to walls etc including dismantling of existing pipe line and fittings etc complete all as specified and directed |
| 81 | S&F PVC bends (any radius) of 110mm dia with access dooretc complete all as specified and as directed |
| 82 | S&FPVC (SWR) branch pieces 110mm dia bore, double (doubleY) equal or unequaletc complete all as specified and as directed |
| 83 | S&FPVC vent cowls suitable for 110mm dia pipe etc complete all as specified and as directed |
| 84 | S&F PVC bends (any radius) of 75mm dia with access dooretc complete all as specified and as directed |
| 85 | S&F PVC (SWR) branch pieces 75 mm dia bore, single (single Y) equal or unequaletc complete all as specified and as directed |
| 86 | Complete removal exising treatment (External/Internal wall) by means of wire brushing, sand paper, manually or mechanically up to visible of plastered surface including rubbing and washing etc complete all as specified and as directed |
| 87 | M&L forPreparation of wall surface with sand paper etc., and applying 1mm thick wall care putty finished to smooth surface etc complete all as specified and as directed |
| 88 | M&L for Preparation finished wall sufaceand applying two coatsDistemper acrylic emulsion, white or tinted over a coat of primer etc complete all as specified and as directed |
| 89 | M&L for Preparationnewplastered ceiling surfaceand applying two coatsDistemper Acrylic emulsion, white or tinted over a coat of primer etc complete all as specified and as directed |
| 90 | M&L for complete removal of existing treatment of ceiling and applying two coatsDistemper acrylic emulsion, white or tinted over a coat of primer etc complete all as specified and as directed |
| 91 | M&L for Preparing new plastered suface of walls and applying two coatsDistemper acrylic emulsion, white or tinted over a coat of primer etc complete all as specified and as directed |
| 92 | M&L for preparation of new plastered surface of wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces etc complete all as specified and as directed |
| 93 | M & L for Preparation of old painted woodensurfaces of any description exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 94 | M&L for Preparation of new or previously un-treated steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed |
| 95 | S&F in repairs stainless steel decorative curtain rod of 25 mm dia bore including fancy finale caps cap (02 nos in each curtain rod)etc complete all as specified and as directed |
| 96 | S&F in repair Brass Chromium Plated designer Bracket for curtain rod of dia 25 mm dia made out of S S Flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long etc complete all as specified and as directed |
| 97 | S&F in repairs Bib Cock, two way double handlewith CP flange,brass chromium plated all as specified and as directed. (Make : Prayag cat No-6812 Marcus seriesor equivalent make as specified in P S) |
| 98 | S&F in repairs Health faucet, brass body with 1mtr S S braidedtube & wall hookcomplete all as specified and as directed (Make : Prayag cat No. BEA-41 or equivalent make as specified in P S) |
| 99 | Removing building materials etc. (other than soil) to a distance of exc 100 mtr but not exc 1.00 Km , including loading, unloading and stacking at the destination etc complete all as specified and as directed |
| 100 | S&F Cloth drying system comprising 4 pipes 6 feet long with following specification complete all as specified and as directed :-(a)Anodised aluminium pipes inner dia 19.8mm & outer dia 22mm(b) Pulleys made of Derlin with rope guide mounted on pair of channel length 24 inches.(Distance between two pipes shall be adjustable)(c) Channel to be fixed with self tapping screws(d) Locking system to hide rope knot(e) Rope shall be polyster braided undyed 3 to 4mm dia |
| 101 | Excavating in post holes or similar holesin hard/dense soil each n exc 0.5cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick all as specified and as directed |
| 102 | M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or tobatter finished fair flat surfaces all as specified and as directed |
| 103 | M & L forRCC (1:2:4) type B-1 using 20mm grded stone aggregate in walls or retaining walls, any thickness, size or shape ncluding pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) all as specified and as directed |
| 104 | M & L forMild steel work in fencing posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and as directed |
| 105 | M & L forGalvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ingbolts, including, securing or tying at crossings with andprovision of galvanised mild steel wire, staples or steelpins, etc. as directed (each line wire to be measured) all as specified and as directed |
| 106 | M & L for Galvanised punched tape 3mm thick concertina coil 600mm dia fixed over angle iron Y type section all as specified and as directed |
| 107 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed |
| 108 | M & L for surfacePoint Wiringwith single core PVC insulated unsheathed FRLS cable 1.5 Sqmm1100 volts grade multi stranded copper conductor conforming to IS 694 drawn through and includingnon-metalic rigid PVC conduit with accessories surface run on walls/ ceilingwith MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly for the followingsall as specified and as directed :- |
| 109 | One light / fan point controlled by one switch |
| 110 | One lightpoint controlled by two wayswitch |
| 111 | One 3 pin socket out let 5 Amps on independent board |
| 112 | One 3 pin socket out let 5 A on same board |
| 113 | One Bell / Buzzer Point controlled by bell push |
| 114 | M & L for Surface point Wiringwith single core PVC insulated unsheathed FRLS cable 2.5 Sqmm1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface type run on walls/ ceiling includingMS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including2.5Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 115 | Note for Item No. 106 & 107 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii)Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket board to be included in point wiring. |
| 116 | S&F in repairs LED batten with luminaire suitable for indoor applications 20 Watts, 4 feet long with extruded aluminiumhousing & integrated LED channelcomplete with all accessories including taking out old fittings all as specified and directed. |
| 117 | S&F in repairs LED batten with luminaire suitable for indoor applications 10 Watts, 2 feet long with Polycarbonate integrated LED channelcomplete with all accessories including taking out old fittings all as specified and directed. |
| 118 | S&F in repairs Decorative, wall mounting ,champagne gold finish fixture with plastic body suitable for 9 watt LED lamp B22 baseall as specified and directed. |
| 119 | S&FSwitch piano flush type single pole one way 5amps, 230 volts all as specified and directed. |
| 120 | S&F Switch piano flush type single pole two way 5amps, all as specified and directed. |
| 121 | S&FDing Dong bellAC 230 volts single pole all as specified and directed. |
| 122 | S&FBell push flush type 5Amps 230voltsall as specified and as directed . |
| 123 | S&F Stepped type electronic fan regulator, flush Switch/socket type, 230voltsall as specified and as directed |
| 124 | S&FSwitch socketcombination2in 1 , 5 Amps flush type, 230volts all as specified and asdirected |
| 125 | S&F Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal type 230volts all as specified and asdirected |
| 126 | S&F in repairsMCB SPN 240 volts,32/40 AmpsC curves complete all as specified and as directed |
| 127 | S&F in repairsMCB single pole 240 volts, 10/16/20/32 Amps, C curvescomplete all as specified and as directed |
| 128 | S&F in repairsMCB Distribution board, SPN 12 way, double door type, 240 volts with 200 Amps rated busbar all as specified and as directed. |
| 129 | S&F Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. completeall as specified and directed. |
| 130 | S&F in repairsMCB Distribution board,TPN 4 way double door type, 240 volts with 200 Amps rated busbarall as specified and as directed. |
| 131 | S&F in repairsMCB TPN,63 Ampscapacity 415 volts, 10 KA, \"C\" curves complete all as specified and as directed |
| 132 | S&F Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 133 | S & F in repairsSub main wiring with two runs single core 6 Sqmm1100 volts grade multistranded FRLS copper conductorswithPVC insulatedsingle core multistranded copper conductor 6 Sqmm cable as earth continuity conductor with & including suitable sizePVC casing capingall as specified and as directed |
| 134 | M&L for earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion includingearth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways, funnel with watering G I pipe wire mesh and lugs, test point including dismantling old un-serviceableearthing complete all as specified and as directed |
| 135 | Supply and fixing in repairsLED bldg securitylight fitting30 Watts capacitywith pressure die cast housing along with prismatic polycarbonate diffuser with IP 66protection all as specified & directed. |
| 136 | S&F in repairs GIBracket made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and includingapplying two coats of aluminum paintover a coat of red oxide primercomplete all as specified and directed. |
| 137 | Supply and fixExhaust fan 300mm sweep, steel body AC single Phase. 230Voltswith, blades, frame and louvers including necessary core cutting arrangement for installation all as specified and directed |
| 138 | S&F fix exhaust fan 225mm sweep, steel body AC single phase. 230Volts with, blades, and frame and louvers complete including necessary core cutting arrangement for installation all as specified and directed |
| 139 | Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed. |
| 140 | M & L for returning, filling in trenches including spreading levelling watering and well ramming in layers with soil not exc 25 cm thick in each layer complete as specified and as directed |
| 141 | M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed |
| 142 | M & L for sand cushioning with a layer of river sand under and above the cable all as per Para 19.75 of SSR Part-I complete all as specified and as directed |
| 143 | Supply & layingsub class \"B\" burnt bricks for cable protection complete as specified as directed |
| 144 | Supply & laying XLPE insulated screened PVC bedded galvanised steel strip or wire armoured,electricaluminium conductor power cable (heavy duty)4 Core x 25 Sqmm, 1100 Volts grade including taking out the existing unserviceable cable all as specified and as directed |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail