| 1 | \"M&L for Servicing and testing of EOT crane upto 5 Ton and comprising of the following:-(a) Greasing/oiling of required part ie shaft, coupling, rope drum shaft bearing etc.(b) Checking & testing/adjustment of brakes for of all the motions(c) Checking & tightening of coupling bolts, motor foundation bolt etc.(d) Checking the wiring connections in control panel and other accessories and toensure that no loose/naked connection exist.(e) Checking of gear oil in gear boxes and topping them if necessary.(f) Checking of transformer oil in electro hydraulic thruster unit & topping up if necessary(g) Cleaning of Bridge girder including plate form, cabin, panel, complete. Note:- Servicing is to be carried out in every three months and making/keeping the cranes in serviceable condition complete all as directed. Each job shall mean each crane.\" |
| 2 | M&L for scrapping and cleaning the old painted surfaces of entire exposed parts of EOT crane of capacity 5 Tonincluding removing oil & grease stains using appropriate cleaning agents and applying two spray coats of synthetic enamel golden yellow paint complete all as specified and directed. |
| 3 | Supply and fixing in repair of Long Travel Electro Hydraulic Thrustor brake 150mm dia suitable for 5 Ton EOT crane as per existing size complete all as specified and directed. |
| 4 | \"Supply and fixing in repair of VFD (variable Frequency driver), Capacity same as existing having Input supply voltage 415V (3 Phase), Frequency 50 Hz, VFD having Facility for selecting motor power rating, over current trip, other protection settings suitable for long travel, cross travel and main motion of 5 Ton crane along with programming in software in driver card complete all as specified and directed. |
| 5 | Supply and fixing in repair set of two gear (as per existing gear/ sample) duly casted / fabricated and cutting teeth as required suitable to accommodate in the cranes Gear Box complete and capacities / sizes of cranes up to 5 Ton complete all as specified and directed. |
| 6 | Supply and fixing in repair of Alignment of Gearbox as per site requirement complete all as specified and directed. |
| 7 | Supply and fixing in repair Bearing bracket of size up to 5 ton FLP EOT crane as per existing gear box (or as per sample) complete all as specified and directed. |
| 8 | Supply and fixing in repair Tapper Roll Bearing as per existing/sample gear box bearing suitable for 5 Ton EOT size complete all as specified and directed. |
| 9 | Supply and fixing in repair of Pendant Push Button box made of MS for control of Crane with Push Button for On/Off & all motions (Up, down, forward, reverse, left, right) for 5 Ton EOT crane operation control, including Wiring from Pendent to Control Panel, from control panel to Master Starter and upto motor should be done by using 4 core, 4.0 sqmm PVC insulated and PVC round sheathed, copper conductor (flexible) multistranded industrial cable 1100 Volts and support wire min 25 mtr as per existing size complete all as specified and directed. |
| 10 | Supply and fixing in repair of LT(Long Travel) & CT(Cross Travel) limit switch for 5 Ton capacity EOT crane with auxiliary contacts as per existing size complete all as specified and directed. |
| 11 | Supply and fixing in repair of CT & LT cable trolleys for 5 Ton EOT Crane alongwith proper alignment of cable trolley as per existing size complete all as specified and directed. |
| 12 | Supply and fixing in repair of Wire rope 12mm for 5 Ton Crane as per existing size complete all as specified and directed. |
| 13 | Supply and fixing in repair of CT wheel for 5 Ton Crane as per existing size complete all as specified and directed. |
| 14 | Supply and fixing in repair of LT wheels 5 Ton Crane as per existing size complete all as specified and directed. |
| 15 | Material and labour for rewinding of transformer mounted in control panel of 230/110V for EOT crane upto 5.0 Ton complete all as specified and as directed. |
| 16 | Supply and fixing in repair of Rotary limit switch 3 phase 415 volt 50 Hz, 10 Amps for EOT crane complete all as specified and as directed. |
| 17 | Supply and fixing in repair of Over load Relay for hoist as per site requirement complete all as specified and as directed. |
| 18 | Supply and fixing in repair of Over load Relay for CT/LT as per site requirement complete all as specified and as directed. |
| 19 | Supply and fixing in repair of 3 Ph, 50Hz 415V MCCB 32A for EOT crane as per site requirement complete all as specified and as directed. |
| 20 | Supply and fixing in repair of Coupling Pinion complete all as specified and as directed. |
| 21 | Supply and fixing in repair of Flexible Cable 4 Sq.mm 4 Core complete all as specified and as directed. |
| 22 | Supply and fixing in repair of Flexible Cable 2.5 Sq.mm 4 Core complete all as specified and as directed. |
| 23 | Supply and fixing in repair of Flexible Cable 1.5 Sq.mm 3 Core complete all as specified and as directed. |
| 24 | Replacement & Dressing of cable trolley with trolley chain complete all as specified and as directed. |
| 25 | Comprehensive maintenance and repair including renewal/replacement and installation of defective parts of all existing fire detection system complete consisting of addressable fire control panel, Conventional Fire Alarm Panel, Remote Terminal Unit panels, smoke/heat detector, response indicator, sounder, Manual call Point, Amplifier, Loud speaker, Loop isolator, Zone monitor module, Modem etc., to make them 100% serviceable incl checking of fire detector, checking the batteries and its connections, alarm system and its functions, functionallity of fire control panel and indicating eqpt all to be checked by the operation of trigger device in each zone as described. The system installed in Fire station and at other locations to be inspected and checked for its functionality and to make functional in all respect and if any defect observed to rectify it by visiting every month through Authorised Original Equipment Manufacturer\"s Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.Note:- (i) Cost of new components shall be paid separately under relevant items.(ii) Contractor\"s rep shall visit every month to check all fire panel and system to check its functionility and to make them functional. if any defect observed. (iii) He shall take the serviceability certificate duly signed by the user and submit to the department. After obtaining/ producing seviceability certificate of system payment will be made to contractor.(iv) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running includes maintenance of all mechanical, electrical and electronic parts /sub-assemblies. The preventive maintenance report will be as per the Original Equipmentmanufacturer\"s instructions and Specification. The Contractor may claim payment on monthly basis.(v) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE Office officials or their representatives, The OEM\"s authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period. |
| 26 | Equipment Park |
| 27 | 501AD Office |
| 28 | 97AD Office |
| 29 | MDF Building |
| 30 | M&L for Servicing and repair of all multisensor detector with photo, heat and smoke combination photoelectric after taking down from its position and refixing after servicing as per OEM instructions through Authorised Original Equipment Manufacturer\"s Service Centre Engineers or through OEM Certified Agencies as approved by GE, checking and testing its functionality, tracing and clearing any fault observed including cleaning detectors through air blower on site complete all as specified and as directed. Note : AS per periodicity of cleaning of detector to be done once in 11 Month or before as and when required basis). |
| 31 | Supply and fixing in repair Indoor type detectors complying with and type certified to EN-54 Addressable type multisensor detector with photo, heat and smoke combination photoelectric /optical with base with self built intelligence as per OEM specification complete all as specified and as directed. |
| 32 | Supply and fix in repair electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with following specifications as under:- Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current), Class A, Initiating Mode - Pressing the action plate manually, Resuming Mode-Manually Resumed by a special Key, Ingress Protection IP-43 & Material-ABS all as per IS : 2189 / 1988 as per OEM specification complete all as specified and as directed. |
| 33 | Supply and fix in repair intelligent loop isolator with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:- a) Power- 24V, ≤ 3 mA (Standby Current) ≤15mA (Action Current) b) Class A, c) Initiating Mode- Yellow flashes when polling, illuminates in action, d) Ingress Protection IP-30 & Material-ABS or as per OEM specification complete. |
| 34 | Supply and fix in repair the announcing device Remote response indicator as per OEM specification complete all as specified and as directed. |
| 35 | Supply and fix in repair fire alarm hooter cum strobe electronic type single stage continous normal operation for atleast 20 minutes with sound level 65db to 120db measured at 1.5 m with sound output variation of +5db 500m range as per OEM specification complete all as specified and as directed. |
| 36 | Supply and fix in repair Wireless modem suitable for GSM based communication system to be mounted in RTU enclosure shall be installed at all proposed buildings as per OEM specification complete all as specified and as directed. |
| 37 | Supply and fix in repair Amplifiers suitable 30 Watts, 230 VAC, 50Hz as per OEM specification complete all as specified and as directed. |
| 38 | Supply and fix in repair Input Module for Fault and Alarm Monitoring, 24VDC required (Zone Monitor Module) as per OEM specification complete all as specified and as directed. |
| 39 | Supply and fix in repair 24V DC Power Supply Unit of iRTU, as per OEM specification complete all as specified and as directed. |
| 40 | Supply and fix in repair 12/5V DC Power Supply Unit of iRTU, as per OEM specification complete all as specified and as directed. |
| 41 | Supply and fix repair ARM7 based CPU card with 3 nos. serial Port, 1 ethernet Port and SD card slot of RTU as per OEM specification complete all as specified and as directed. |
| 42 | Supply and fix in repair Analog and Digital I/O Card of RTU, as per OEM specification complete all as specified and as directed. |
| 43 | Supply and fix in repair DI/AI Termination PCB of RTU, as per OEM specification complete all as specified and as directed. |
| 44 | Supply and fix in repair Display and Keyboard of RTU,as per OEM specification complete all as specified and as directed. |
| 45 | Supply and fix in repair DO Termination PCB of RTU, as per OEM specification complete all as specified and as directed. |
| 46 | Supply and fix in repair MCB 6A SP, C curve , 10 KA as per OEM specification complete all as specified and as directed. |
| 47 | Supply onlyLEDs (Red/Green) for RTU Panel.as per OEM specification complete all as specified and as directed. |
| 48 | Supply and fix in repair Relay card : 8 relay 1 Change over for RTU panel as per OEM specification complete all as specified and as directed. |
| 49 | Supply and fix in repair Push Button with NO/NC contact (BLACK) as per OEM specification complete all as specified and as directed. |
| 50 | Supply and fix in repair LCD Screen CGM12864 for FACP as per OEM specification complete all as specified and as directed. |
| 51 | Supply and fix in repair GST200 Rubber Keypad F7.843.249for FACP as per OEM specification complete all as specified and as directed. Make: Siemens and equivalent make in Bosch/GST/Morley as per approval of GE) |
| 52 | Supply and fix in repair GST200 Loop Interface Board F2.908.828 (RoHS) for FACP as per OEM specification complete all as specified and as directed. |
| 53 | Supply and fix in repair FACP Transformer 220V/27V-100W-R as per OEM specification complete all as specified and as directed. |
| 54 | Supply and fix in repair Sine Wave UPS Inverter Capacity : 850 VA as per OEM specification complete all as specified and as directed. |
| 55 | Supply and fix in repair conventional MCP, Red colour with LED 470 ohms, with back box andsurface mouting box red colour as per OEM specification complete all as specified and as directed. |
| 56 | Supply and fix in repair Transistor with heat sink for fire panel as per OEM specification complete all as specified and as directed. |
| 57 | Supply and installation of ABC type stored pressure type fire extinguishers 6Kg capacity with Monoammonium Phosphate complete with squeeze grip type valve, discharge hose & mounting bracket as per OEM specification complete all as specified and as directed. |