| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-12-2025 | Corrigendum I (School Minicoy) | Date | 02-01-2026 |
| Sl. No. | Item Description |
| 1 | EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 3 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 5 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 7 | Filling in plinth or trenches underfloors, foundations in areas etc with red earth ( from main land) in layers not exceeding 20cm in depth, consolidating each depositedlayer by ramming and watering, lead upto 50 m and lift upto 1.5m including cost and conveyance of all materials, labour charges etc. complete at all levels as directed by Engineer-in-charge |
| 8 | Carriage of materials by mechanical transport including loading, unloading and stacking lead up to 5 km, including all lifts involved as directed by the Engineer-in-Charge. Surplus Excavated Earth |
| 9 | Extra rates for quantities of earth works, executed: In or under water and/or liquid mud, including pumping out water as requiredNote for item no. 2.24:- The extra percentage rate is applicable in respect of each item but limited to quantities of work executed in these difficult conditions. The unit, namely, metre depth, to be considered for payment, shall be the depth measured from the sub soil water level up to the centre of gravity of the qty executed in difficult conditions. The depth shall be reckoned correct to 0.10 m, 0.05 m or more shall be taken as 0.10 m and less than 0.05 m ignored |
| 10 | Providing and applying Antitermite treatement by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre-constructional treatement and creating a chemical barrier as per IS 6313 (Part ll) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building,etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge.(Plinth area only to be measured for the payment ) (The above work shall be carriedout by an agency having sufficient experience and should ensure a warranty for a period of 10 years. Only skilled and experienced persons shall be employed for this purpose.) |
| 11 | CONCRETE WORK |
| 12 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 14 | Providing and Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 15 | Providing and laying autoclaved aerated cement blocks filling with 150mm/230mm/300 mm thick AAC blocks laying in sunken portion with approved blockin cement mortar 1:4 ,cost and conveyance of all materials, labour charges etc. complete at all levels as directed by Engineer-in-charge |
| 16 | Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. completeThe quantity will be calculated by multiplying the depth measured from the sub-soil water level up to centre of gravity of concrete under sub-soil water level with quantity of concrete in cum executed under sub-soil water. The depth of centre of gravity shall be reckoned correct to 0.1m. 0.05m or more shall be taken as 0.1m and less than 0.05m ignored |
| 17 | REINFORCED CEMENT CONCRETE |
| 18 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M30 grade with minimum cement content of 350 kg /cum. |
| 19 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M30 grade with minimum cement content of 350 kg /cum. |
| 20 | Extra for laying reinforced cement concrete in or under water and/ or liquid mud, including cost of pumping or bailing out water and removing slush etc., completeThe quantity will be calculated by multiplying the depth measured from the subsoil water level up to the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under sub - soil waterconditions. |
| 21 | Add for using extra cement in the items of design mix over and above the specified cement content therein |
| 22 | Providing and fixing of expansion joint system related with floor location as per drawings and directionof Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / selfcentering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that itprovides floor to floor /floor to wall expansion control system for various vertical localtion in loadapplication areas that accommodates multi directional seismic movement without stress to it\"scomponents. System shall consist of metal profiles with a universal aluminum base member designed toaccommodate various project conditions and finish floor treatments. The cover plate shall be designed ofwidth and thickness required to satisfy projects movement and loading requirements and secured tobase members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates /moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock andslide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure inall directions including vertical displacement. Provision of Moisture Barrier Membrane in the JointSystem to have watertight joint is mandatory requirement all as per the manufactures design and asapproved by Engineer -in-Charge. (Material shall confirm to ASTM 6063).Floor Joint of 150 mm gap |
| 23 | Providing and fixing of expansion joint system related with wall joint (internal/external) location as perdrawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members,self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall besuch that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to cornerapplication, both new and existing construction in office Buildings & complexes with no slipping downtendency amongst the components of the Joint System. The Joint System shall utilize light weightaluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking themulticellular to facilitate movement. (Material shall confirm to ASTM 6063)Wall Joint of 150 mm gap |
| 24 | Providing and fixing of expansion joint system of approved make and manufactures for various rooflocations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extrudedaluminum base members with, self aligning and self centering arragement support plates asper ASTMB221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint coverexpansion control system that is capable of accommodating multidirectional seismic movement withoutstress to its components. System shall consist of metal profile that incorporates a universal aluminumbase member designed to accommodate various project conditions and roof treatments. The cover plateshall be designed of width and thickness required to satisfy movement and loading requirements andsecured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement thatfreely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere endsthat lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movementand flexure in all directions including vertical displacement. The Joint System shall resists damage ordeterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foottraffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to havewater tight joint is mandatory requirement. (Material shall confirm to ASTM 6063Roof Joint of 150 mm gap |
| 25 | STEEL |
| 26 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 28 | Providing fusion bonded Epoxy coating not less than 175 micron thickness and upto 300 micron to reinforcement barsof any diameter as per IS-13620-1993/ ASTM-775 M including repairs to cut ends,welded spouts and handling damages with reccomendedliquid epoxy compatible with the coating and testing of coating at plant etc complete as directed by engineer ion charge. |
| 29 | FORM WORK |
| 30 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete |
| 31 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 32 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 33 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Stairs, (excluding landings) except spiral-staircases |
| 34 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Weather shade, Chajjas, corbels etc., including edges |
| 35 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform |
| 36 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 37 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 38 | MASONARY WORK |
| 39 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 40 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:21850(Part 3) in super structure above plinth level up to floorV level in cement mortar 1:4 (1 cement :4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 41 | Providing and laying solid block masonry 20cm thick using best quality blocks ofavailable size in cement mortar 1:6 ( 1cement: 6 coarse sand )for walls at any area (including duct walls,fin walls skin / ledge wall ,kerb wall etc) .The rate including cost, conveyance and unloading at site and stacking of all materials, all labour, scaffolding, watering, curing etc complete as per the direction of Engineer in charge. |
| 42 | Providing and laying solid block masonry 10cm thick using best quality blocks ofavailable size in cement mortar 1:4 ( 1cement: 4 M. sand )for walls at any area (including duct walls,fin walls skin / ledge wall ,kerb wall etc) .The rate including cost, conveyance and unloading at site and stacking of all materials, all labour, scaffolding, watering, curing etc complete as per the direction of Engineer in charge. |
| 43 | FLOORING WORKS |
| 44 | Providing material and labour for laying 18 to 20 mm Mirror Polished Kota stone of approved quality, selected and sorted for uniform color & texture, in internal/external flooring work. .Kota stone is to be laid and jointed with grey cement slurry mixed with pigment to match the shade of the slabincluding rubbing and mirror polishing completed withbedding of average 25 mm thickness cement mortar in 1:4 (1 cement : 4 coarse sand). |
| 45 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 46 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laidon 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of theslabs, including rubbing and polishing complete. |
| 47 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 48 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size.Size of Tile 600 x 600 mm. |
| 49 | Providing and laying fully Vitrified matt tiles in different sizes (thickness to be specified by manufacturer),with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in allcolours & shade, in dadoing, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sq.m including grouting/filling thejoint with white cement & matching pigments,cost and conveyance of all materials, labour charges etc. complete at all levels as directed by Engineer-in-charge Size of Tile600x600 mm |
| 50 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 51 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting,riser of steps ,over 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 52 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm |
| 53 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 54 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 55 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 56 | JOINERY WORKS |
| 57 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners if required to be paid for separately) :For fixed portion.Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 58 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 59 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 60 mm |
| 60 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick :Float glass panes. 4 mm thick glass pane (weight not less than 10kg/sqm). |
| 61 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick :Float glass panes. 5 mm thick glass pane (weight not less than 10kg/sqm). |
| 62 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 63 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 64 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 65 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm |
| 66 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles ofapproved quality with necessary screws etc. complete. |
| 67 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :100X58X1.90 mm |
| 68 | Providing and fixing of Glass Reinforced polymer (GRP) Door Frames of cross-section 100 mm x 50 mm having single rebate of 42/47 mm x 15 mm to receive shutter of 40/45 mm thickness of approved colour/ texture including architrave. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2.5 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.including cost and conveyance of all materials, labour charges etc. complete at all levels as directed by Engineer-in-charge complete as per direction |
| 69 | Providing and fixing of 40 mm thick Glass Reinforced Polymer (G.R.P.) flush door shutter in different plain of Approved colour/ texture with fire retardant grade unsaturated polyester resin, moulded to 3.5 mm thick GRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of G.R.P. laminate conforming to table - 3 of IS: 14856,including cost and conveyance materials, labour charges etc. complete at all levels as directed by Engineer-in-charge complete as per direction of Engineer-in-charge. |
| 70 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm |
| 71 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 72 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover |
| 73 | Providing and fixing ball bearing for rolling shutters |
| 74 | Providing and fixing an SS sliding mosquito net for windows and doors involves custom-measuring the window or door, sourcing durable stainless steel mesh, and installing a sturdy frame with sliding tracks. The mesh size is of 18 x 16 OPI (openings per inch, 18 openings per inch horizontally and 16 openings per inch vertically). The net is securely attached, and the sliding mechanism is set up for smooth operation. Professionals ensure a perfect fit, easy sliding, and long-lasting protection against mosquitoes, offering a practical, rust-resistant solution for homes and businesses. |
| 75 | WATER PROOFING WORKS |
| 76 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 77 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 78 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm |
| 79 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm. |
| 80 | FINISHIG WORK |
| 81 | 12mm cement plaster of mix1:4 (1 cement : 4 fine sand) including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels - Internal plastering |
| 82 | 15 mm cement plaster on the rough side of single or half brick wall of mix : : 1:4 (1 cement: 4 fine sand) |
| 83 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 84 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 85 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1: 3 (1 cement: 3 fine sand)including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels. - |
| 86 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 87 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 88 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 89 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 90 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 91 | Supply and fixing of Cast iron cover with frames for manholes of size 600 mm x 600 mm rectangular C.I. cover with frame (Heavy Duty )The weight of the cover and frame to be not less than 100 Kg. |
| 92 | Providing and Fixing ofBuilding signages as per following specifications - Sign to be made shall be made of 3 mm aluminium / Acrylic Box Letters (100mm thick letters). Sign Face shall be in 3mm 0/40 Translucent Acrylic with Male / 10mm Water Proof Sun board Female Joint Adequate LED of Samsung Make shall be fitted with the required wiring & Waterproof Transformer to have the uniform Light. A provision for Weather Proof Box shall be made to keep the Transformers. The signages to be fixed on the structural ACP + MSframework with required sizes as per the design. The item includes design of supporting arrangement, fabrication, installation and commissioning the signages with structural framing including channels, angles, gusset plates and anchoring the frame by anchor fasteners to the Building. The structural framing should be painted with primer and enamel paints |
| 93 | Room/Function identification holders signs made of imported clear acrylic of size 127mm x 127mm x5mm thickness . The room location will be made 0.8mm raised computer cut with 16mm high. Signage will be painted with DuPont paint as per approved shade card. |
| 94 | Room/Function identification holders signs made of 127mm x 127mm x3mm thick SS fixed on 3mm thk foam board with double sided tape.The room location will be made 0.8mm raised computer cut with 16mm high. Signage will be painted with DuPont paint as per approved shade card. |
| 95 | Grading roof for water proofing treatment with Cement concrete 1:2:4 |
| 96 | Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete(steel frame work to be paid separately). |
| 97 | Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on steel frame work complete (steel frame work to be paidseparately). |
| 98 | STRUCTURAL STEEL |
| 99 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 100 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 101 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 102 | Providing and fixing stainless steel(grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 103 | INTERIOR |
| 104 | FALSE CEILING |
| 105 | Providing and fixing Gysum false ceiling (12.5 mm) at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS Certification marks) |
| 106 | Providing & fixing 8 mm thick Calcium Silicate false ceilingat all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture\"s specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. |
| 107 | MOVABLE FURNITURE |
| 108 | Providing and fixing conference table of size 7200mm Lenght x 1300 mm Width. Legs shall be made from 25 mm PPB having a straight profile with half round edges and clad with 0.6 mm thick post forming laminat. Overall thickness of leg shall be 26.2 mm.Modesty panel of understructure shall be made of 18 mm thick Pre laminated Twin Board. |
| 109 | Providing & fixing conference and admin chair. SEAT/BACK ASSEMBLY: The seat should be made up of 1.2 ± 0.1cm. thick hotpressed plywood and upholstered with leather and moulded Polyurethane Foam. The back foam should be designed withcontoured lumber support for extra comfort. BACK SIZE: 53.0cm.(W) X 95.4cm.(H) SEAT SIZE: 54.6cm.(W) X 49.0cm.(D) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HRpolyurethane foam should be moulded with density = 45 +/-2 kg/m³ and Hardness load 16 ± 2 kgf for 25% compression.SEAT-BACK CONNECTING SPINE:The seat and back should be arrested together with spine made of 0.8 ±0.05 cm thkHR Steel and should be black powder-coated ( DFT 40-60 microns ).ARMREST ASSY: The armrest assy. should comprise of three parts viz. the armrest support tube and P.U. armrest and thearmrest top. The armrest tube assy. should be made of 2.54±0.03cm x 0.16±0.0128cm M.S. E.R.W. support tubes andChrome plated. The P.U. armrest should be made of black integral skin polyurethane with 50-70 shore \"A\" Hardness andreinforced with M.S. insert. The armrest top should be made of ABS & upholstered with foam & leather. FRONT PIVOT SYNCHRO TILT MECH.: The mechanism should be designed with the following features:•360° revolving type.•Seat back tilting ratio of 1 : 1.5•Front pivot for tilt with feet resting on ground ensuring more comfort.•Tilt tension adjustment.•5-position locking with anti-shock back mechanism, which prevents the backrest from impacting the user when the lockshould be released.•Static seat depth adjustment = 5.0 ± 0.5cm with 5 position locking.PNEUMATIC HEIGHT ADJUSTMENT: it has an adjustment stroke of 9.0 ± 0.3cm.BLOW MOULDED BELLOW : The bellow should be 1 piece and blow moulded in black Polypropylene.PEDESTAL ASSY: The pedestal should be made of die-cast aluminium with buffing finish. It should be fitted with 5nos. twinwheel castor. The pedestal should be 67.0 ± 0.5cm pitch-center dia. (77.0 ± 1.0cm with castors).TWIN WHEEL CASTORS: The twin wheel castors should be injection moulded in black Nylon. |
| 110 | Providing and supplying High back chair. SEAT/BACK A SSEMBLY: The seat is made up of 1.2 + 0.1cm thk. hot pressed plywoodmeasured as per QA method described in OCP-QLTA-PL14-18.The Back is made up of injection mou1ded glass filled nylon& upholstered using Mesh fabric with high tenacity yarn.HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45+/-2 kg/m°and hardness 16 + 2 kgf as per IS:7888 for 25% compression.ARMRESTS : The adjustable armrest is designed with Up-Down adjustment— 8 steps (8 0+0.Scm range) Height adjustable armrest structure which is Powder Coated & fitted with an armrest top. Fixed Armrest Top is PU moulded over metal insert.LUMBAR SUPPORT ASSEMBLY: The Lumbar support consists of polypropylene pad with moulded polyurethane foam &covered with polyester fabric.The Height of Lumbar pad can be adjusted through two projecting knobs provided on the rearside of the pa6. Lumbar pad has an adjustment of 8.0 + 0.5 cm in height.FRONT PIVOT SYNCHRO MECHANISM: The adjustable tilting mechanism is designedwith the following features. 360° revolving type.Single point control. Front-pivot for tilt with feet resting on ground ensuring more comfort. Tilt tension adjustment.4-position locking with anti-shock feature.Seat/back tilting ratio of 1:2.NECKREST : The Neckrest assembly consist of polypropylene pad with moulded polyurethane foam & covered withpolyester fabric Neckrest is fixed to Back Assembly through Neckrest connector Neckrest assembly has height adjustment. |
| 111 | Providing and fixing visitors chair,The seat and back are made of injection moulded high impact strenght polypropylene polymer compound with indoor grade UV Resistance.The tubular weled frame is made from Dia2.22 +/- 0.03cmx 0.12+/- 0.0128 cm and 3.5+/- 0.03 cm x 0.12+/-0.0128 cm stainless Steel 202 grade tube.The tube of green guard by ul certified chair shall be buffed polished to give shinyfinish. The Shoes are made of high impact strenght polypropylene polymer compond with indoor grad UV Resistance andpressed fitted with tubularfram. |
| 112 | Providing & fixing Study table with prelaminated plywood confirming IS 710 grade 16mm ,with 1mm thick laminated fixing on drawer shutters and all visible areas.Best quality accessories and telescopic sliders for drawers to be used(HETTICH/DORMA OR EQ) (TABLE SIZE: 900MMX50MMX75MM, DRAWER SIZE: 300MMX150MM[H]) |
| 113 | Providing and fixing Classroom Table with Bench of size 1100 x 860 x 750 mm for 2 persons consist of25 mm thick pre laminated particle board of approved make with2mm PVC Edge band on desk , bench and back.The end frames forunderstructure are made of 25 mm square x 1.6 mmthick ERW(Electrical Resistant Welding) tube and 5 no:s cross beams connecting end frame are made of 25 mm square x 1.6 mm thick ERW tube. For the foot rest 25 mm square x 1.6mm thick ERW tube will be at 180 mm high from floor level on front.Under Shelf is made of 0.8mm thick CRCA mounted below desk. All made of Knockdown Construction with all metal items are powder coated with 60+-10 microns. Sample furniture must be appoved by the Architect/Engineer-In-Charge prior to procurement. |
| 114 | Providing and fixing chair with writing pad and upholstered with fabric cushion seat and back with arm rest and black powdercoated legs.Sample furniture must be appoved by the Architect/Engineer-In-Charge prior to procurement. |
| 115 | Providing and fixing of Computertable of 1000mm x 600 mm x 750 mmhaving 18mm thick MDF Laminated Board table top of 1000mm x 700mm +18mm with Floor Mounted under Bench Storage Unit having CPU Box Front Open Type of320mm x 570mm x 720mm and Leg space/cross brace/foot rest/key board drawer/ cable manager/back panleand. and 450mm X 100 mm x 100 mmElectric TRunking Box having 6/16 Amp switch Socket and RJ45 Cat 6Data POint of approved make. Completely made of High zinc coated Galvanized Steel 1.0 mm thicknessprime export quality material with test certificate from galvanized steel manufacturer as per IS 277 standard. The shutter & drawer front should be of sandwich construction. Foam sheet filled in shutter gaps must required. The sound deadning Buffer to be used to minimize banging noise while closing the shutter.The shuttersare mounted to the modules by hinges which are openable to 90 degree & self closing on return. Lockable roller bearing to be usedso that the drawerwill not fall. The telescopic drawer slides which should be very sturdy &able to take load upto 30kg to 40Kg. Handle should be Aluminium Concealed Handle.All modulesto have lock and key arragement. Modules Completely finished with epoxy powdercoating. with minimum coatoing layer of 70-80 micron.Sample furniture must be appoved by the Architect/Engineer-In-Charge prior to procurement. |
| 116 | Providing lab chairs withSW with PVC ringhandle, Gas Lift, Fiber stand with royal castor attached, 32 Density Foam for cushioningwithcompany press moulded ply, high quality craps cloth.Sample furniture must be appoved by the Architect/Engineer-In-Charge prior to procurement. |
| 117 | Providing and fixing Centre Tableof size 1800 x 900 x 750 mm25 mm thick pre laminated particle board of approved make with Mahagony finish on top. All made of Knockdown Construction with all metal items are powder coated with 60+-10 microns. Sample furniture must be appoved by the Architect/Engineer-In-Charge prior to procurement. |
| 118 | Providing and fixing Storage unit of size 750x600x750 mm. Completely made of 25 mm thick pre laminated particle board of approved make. The shutters which are openable to 90 degree & self closing on return.Modules Completely finished with epoxy powdercoating. with minimum coatinglayer 60 micron.Sample furniture must be appoved by the Architect/Engineer-In-Charge prior to procurement. |
| 119 | Providing and fixingfaculty Tableof size 1500 x 650 x 750 mm25 mm thick pre laminated particle board of approved make with Mahagony finish on top. All made of Knockdown Construction with all metal items are powder coated with 60+-10 microns. Sample furniture must be appoved by the Architect/Engineer-In-Charge prior to procurement. |
| 120 | Providing and fixingfaculty chair of FP Invention with Multilock Mechanism ,Gaslift & Two Way AdjustableArms (Height & Swivel) with Chrome Base- Leatherette Seat & Back.Sample furniture must be appoved by the Architect/Engineer-In-Charge prior to procurement. |
| 121 | Providing and fixing book shelves of size 2000x450 x1950 mm with Upright - MS 40 x 40 x 1.6 Tube,Side Profile - MS Powder coated metal profile of 1.6mm with Acrylic pouch and band made of MS Powder coated metal 1.6mm. Shelves shall be made of MS powder coated metal 1.2mm supported with brackets,back panels made of MS Powder coated metal 0.8mm top panel , side panel & bottom panel made of 18mm thk plate.Sample furniture must be appoved by the Architect/Engineer-In-Charge prior to procurement. |
| 122 | Providing and fixing reading chair,The seat and back are made of injection moulded high impact strenght polypropylene polymer compound with indoor grade UV Resistance.The tubular weled frame is made from Dia2.22 +/- 0.03cmx 0.12+/- 0.0128 cm and 3.5+/- 0.03 cm x 0.12+/-0.0128 cm stainless Steel 202 grade tube.The tube of green guard by ul certified chair shall be buffed polished to give shinyfinish. The Shoes are made of high impact strenght polypropylene polymer compond with indoor grad UV Resistance andpressed fitted with tubularfram. |
| 123 | Providing and fixing Cupboard of 2610mmX450mmX1800mm with 2 horizontal compartment contain 2 adjustable shelfs in ecah compartment in which 1 is fixed and isCompletely made of 20 G High zinc coated Galvanized Steel 1.0 mm thicknessprime export quality material with test certificate from galvanized steel manufacturer as per IS 277 standard. The shutter & drawer front should be of sandwich construction. Foam sheet filled in shutter gaps must be required. The sound deadning Buffer to be used to minimize banging noise while closing the shutter.The shuttersare mounted to the modules by hinges which are openable to 90 degree & self closing on return. Lockable roller bearing to be provided for drawers. The telescopic drawer slides which should be very sturdy &able to take load upto 30kg to 40Kg. All modules should have lock and key arragement. Modules shall be completely finished with epoxy powdercoating with minimum coatinglayer 70 to 80 micron. Clear Glass Door shall be of 4 mm thick with lock and handle. |
| 124 | Providing and fixing of tabel of 4190mm x 750 mm x 750mm consists of 18mm -20 mm thick Jet BlackGranite Top with Edge moulding at the front and grove at the bottom to avoid by chemical spillage and is supported by rubber strip 6mm x 40 mm sheet of 1225mm +3935mmx 610mm +18mm with floor mounted under bench storage withdrawers unit of 1 drawer /2 shutter & 1 shelf unit of600mm x 500mm x 720mmand 3 drawer unit of 600mm x 500mm x 720 mm andLeg space/Cross Brace /foot rest/key board drawer / Cable Manager / Back pane.corner top support frame of 500mm x 500mm x 720mm and front gap covering panel of 580mm x 720 mm.Completely made of High zinc coated Galvanized Steel 1.0 mm thicknessprime export quality material with test certificate from galvanized steel manufacturer as per IS 277 standard. The shutter & drawer front should be of sandwich construction. Foam sheet filled in shutter gaps must required. The sound deadning Buffer to be used to minimize banging noise while closing the shutter.The shuttersare mounted to the modules by hinges which are openable to 90 degree & self closing on return. Lockable roller bearing to be usedso that the drawerwill not fall. The telescopic drawer slides which should be very sturdy &able to take load upto 30kg to 40Kg. All modulesto have lock and key arragement. Modules Completely finished with epoxy powdercoating. with minimum coating of 70-80 micron |
| 125 | Providing and fixing of L shaped sitting table of 1200mm+2900mm x 750mm x 750mm consists of 18mm -20 mm thick Jet BlackGranite Top with Edge moulding at the front and grove at the bottom to avoid by chemical spillage and is supported by rubber strip 6mm x 40 mm sheet of 1375mm +3935mmx 610mm +18mm with floor mounted under bench storage withdrawers unit of 1 drawer /2 shutter & 1 shelf unit of600mm x 500mm x 720mm and 1 drawer/2 shutter & 1 Shelf unit of 750mm x 500 mm x 720mm and adrawer unit of 600mm x 500mm x 720 mm andLeg space/Cross Brace /foot rest/key board drawer / Cable Manager / Back pane.corner top support frame of 500mm x 500mm x 720mm and front gap covering panel of 580mm x 720 mm.Completely made of High zinc coated Galvanized Steel 1.0 mm thicknessprime export quality material with test certificate from galvanized steel manufacturer as per IS 277 standard. The shutter & drawer front should be of sandwich construction. Foam sheet filled in shutter gaps must required. The sound deadning Buffer to be used to minimize banging noise while closing the shutter.The shuttersare mounted to the modules by hinges which are openable to 90 degree & self closing on return. Lockable roller bearing to be usedso that the drawerwill not fall. The telescopic drawer slides which should be very sturdy &able to take load upto 30kg to 40Kg. All modulesto have lock and key arragement. Modules Completely finished with epoxy powdercoating. with minimum coating of 70-80 micron |
| 126 | Supply and installation of Pantry Chairs stackable type with Polypropylene seat and back and four point stainless steel legs as per directions of Engineer-in-charge (Warranty period: 5 years |
| 127 | :Fabrication, Supply Installation of Cafeteria Table of Size 1350mmX 900mm .Tableframe work made up of ase 48A Stainless Steel, Dim(mm) W-620 x D-510, H- 840, rectangular top SS 306 Hollow tubes of 40 mm Sq for verticals and horizontals at top and bottom finished with matt finish .Table top formed with single piece of High Density particle Board density - 750 - 800Kg/m3, Surface finish: Melamine Laminate, Glue: Melamine Urea Formaldehyde, Top Thickness: In middle 18mm Thick & in corner -25mm thick with waterfall edge of full body vitrified tile of size 900 x 1200 mm of 16 mm Thick Edges shall be round moulding and tile shall be fixed over the SS Metal Structure with necessary screws and clamps etc.The quoted rate shall includes the cost of all materials and labours, tools and tackles etc . Measured in numbers for the given size of the table and paid. |
| 128 | Providing & fixing2 seater sofa with dimension -1800 mm Width x 950 mm Depth x 950 mm Height.Frame shall be made of combination of 12 mm moisture resistance and termite free plywood and pine wood (without knot)having cross section 34x64mm.Seat - shall be made of slab stock foam of density of base 28 kg/ meter cube and super soft 32 kg/meter cube at top. Seatshall be embeded with 2mm pocket spring.Seat Back - made of slab stock foam of density 28 kg/ meter cube pasted on back. Front of the back rest shall be made ofloose conjugated polyester fiber webbing.Legs - legs shall be made of rubber wood.Facia - facia of the sofa shall be made of membrane pressed MDF. |
| 129 | Providing & fixingTeapoy of 900x600mm and Glass should be 12 ±0.3 mmtoughened glass uv glued with bushes made in ss 202 grade for fixing with under structure. it should be a welded assembly made in ss202 grade having dia 12mm. |
| 130 | EXTERNAL DEVELOPMENT |
| 131 | Procuring healthy grass free from weeds and foreign materials and laying on the soil medium as turfing,the rate include for grass cost, transport to site, cost and application of manure, planting, labour, supervision and maintenance for 2 months after plantingPearl Grass |
| 132 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Royal palm |
| 133 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Foxtail palm |
| 134 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Bismarkia palm |
| 135 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Elenji tree |
| 136 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Malpighia Topiary in steel mesh |
| 137 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Eugenia Topiary |
| 138 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Clerodendrum Inerme -Hedge |
| 139 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Murraya Exotica - Flower bush |
| 140 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Heliconia Caribea |
| 141 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Areca tree |
| 142 | Supplying , stacking and spreading sludge / well decayed farm yard manure from thesource,Mixing earth and manure or in proportion specified or directed, Spreading ofdung manure or / and good earth in required thickness.and fine dressing the ground as per natural gradiantapproved by the engineer in charge incl. screening, loading, unloading, conveyance and stacking at site. |
| 143 | Supply and installation of 14mm (minimum) thickand 16mm (minimum) at high stress areas EPDM and PUR coated Sandwich Type Track OR Full PU system Track, colored, impermeable, full pour, spike and ultraviolet resistant self-leveling polyurethane Athletic Running Track system both fully certified and confirming the requirement of IAAF (International Association of Athletic Federation) to a total thickness of 14mm including game line marking all complete as per “IAAF” standard and specification. The cost includes all material and manpower for priming for SBR layer,installation of SBR layer,PU layer,EPDM and PU top coat,line marking,neccessary rubbing,cleaning etc all complete as per specifacations and drawings approved by the Architect.All works must be executed by authorised agency/vendor approved by the Engineer-In-Charge |
| 144 | Supply and installation of 50mm quality proturf imported from FIFA quality manufactures with minimum 12 years warranty with proper infill (quarts sand as 2.5kg/sqft and crumbed rubber granules as 0.8kg/sqft) and standards as per FIFA.18000Dtex Density: 20172t/sqm, Gauge: 5/8 inch, Stitches: 280s/m. All filaments must have specially designed S curve structure. The cost includes all material and labour for supply,applying anti termite and weedicide, laying, infilling, polypropylene fibers Geotextile separation barrier of 200 GSM as per the standard procedure, line marking of ground material and two numbers of FIFA standard goal posts etc all complete as per the direction of Engineer-In-Charge.All works must be executed by authorised agency/vendor approved by the Engineer-In-Charge |
| 145 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 146 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge |
| 147 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 148 | Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side, including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 coarse sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-charge. |
| 149 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin-charge). |
| 150 | MEP |
| 151 | WIRING |
| 152 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 153 | Group C |
| 154 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 155 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 156 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 157 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 158 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 159 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 160 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 161 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 162 | 20 mm |
| 163 | 25 mm |
| 164 | 32 mm |
| 165 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 166 | 5/6 A switch |
| 167 | 2 way 5/6 A switch |
| 168 | 15/16 A switch |
| 169 | 3 pin 5/6 A socket outlet |
| 170 | 6 pin 15/16 A socket outlet |
| 171 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 172 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 173 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 174 | 1 or 2 Module (75mmX75mm) |
| 175 | 3 Module (100mmX75mm) |
| 176 | 4 Module (125mmX75mm) |
| 177 | 6 Module (200mmX75mm) |
| 178 | 8 Module (125mmX125mm) |
| 179 | MCCB, MCB & DB’S |
| 180 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 181 | 8 way , Double door |
| 182 | 12 way , Double door |
| 183 | 16 way , Double door |
| 184 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 185 | 6 way (4 + 18), Double door |
| 186 | 8 way (4 + 24), Double door |
| 187 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 188 | 4 way (4 + 12), Double door |
| 189 | 8 way (4 + 24), Double door |
| 190 | 12 way (4 + 36), Double door |
| 191 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 192 | Single pole |
| 193 | Double pole |
| 194 | Triple pole |
| 195 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 196 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 197 | 25 A |
| 198 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 199 | 40 A |
| 200 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 201 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 202 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 203 | EARTHING |
| 204 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 205 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 206 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 207 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 208 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 209 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 210 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 211 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 212 | MV CABLE LAYING |
| 213 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 214 | Upto 35 sq. mm |
| 215 | Above 35 sq. mm and upto 95 sq. mm |
| 216 | Above 95 sq. mm and upto 185 sq. mm |
| 217 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 218 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 219 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 220 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 221 | HT CABLE LAYING |
| 222 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. |
| 223 | Above 120 sq. mm and upto 400 sq. mm |
| 224 | MV CABLE JOINTING & END TERMINATION |
| 225 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 226 | 3½ X 35 sq. mm (32mm) |
| 227 | 3½ X 50 sq. mm (35mm) |
| 228 | 3½ X 95 sq. mm (45mm) |
| 229 | 3½ X 185 sq. mm (57mm) |
| 230 | 4 X 10 sq. mm (25mm) |
| 231 | 4 X 16 sq. mm (28mm) |
| 232 | HV CABLE JOINTING & END TERMINATION |
| 233 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : |
| 234 | 300 sq. mm |
| 235 | HT EQUIPMENT |
| 236 | RMU |
| 237 | 11KV Outdoor Metering Cubicle |
| 238 | SITC of 11KV Outdoor Metering Cubiclecomprising of : 3 Nos. Current transformer (---/5A,15VA,class 0.2s) 1 No.Potential transformer(11KV /110V,100VA,class 0.2) Separate Compartment for CT/PT and TOD Meter with electrical sealing facilityTTB with Fuse and CarrierProvision for incoming and outgoing XLPE 11 KV Cable and cable entry from bottom side withcable box suitable for 3 x 300 sqmm XLPE, 11KV Al: cable Enclosure-Powder coated CRCA sheet 2MM –IP 54 |
| 239 | 11KV TOD Meter |
| 240 | SITC of 11KV/ √3 / 110V/ √3 , Class 0.2S , 15VA HT TOD Meter suitable for mounting outdoortype with all standard accessories.11 KV KSEB metering cubicle, lead wires etc.complete Carrying CT/PT units with TOD meter for testing and calibrating at the electricalTesting Lab and taking back the same to the site isincluded in the scope of the contractor.Statutory testing fees shallbe remitted and will be reimbursed against producing original receipt |
| 241 | 11KV Multi Panel System (VCB/LBS/LBS) |
| 242 | SITC of H.T 4 Panel comprising of : Incomer1 No. Indoor type 11kV, 630A, 26.3kA for 3 sec Horizontal Draw out VCB fittedwith Manual / Motor operated spring charging mechanism with 230V AC motor andmotor control switch, shunt trip coilof 24V DC, closing coil of 24V DC, Auxiliary Contact 6NO + 6NC, MechanicalON/OFF indicator,mechanical operation counter, master trip relay , auxilliary relay with multifunction meter, voltmeter with selectorswitch and 3 nos ammeter , necessary cast resin current transformer(45/5A , Cl:5P10,/ Cl: 1,15 VA-dual core),Potential transformer ( 11KV/110V , Cl:0.2 , 25VA ) Anti pumping feature, instantaneous IDMT relay withMicroprocessor based 3O/C + and 1E/F Protection relay, Strip Heater with thermostat , Power pack230V AC-24 V DC emergency OFF push button with Aluminium busbar and copper earthing strip, incoming cable entry at bottom suitable for 3 x 300sqmm 11KV XLPE Al: cable Outgoing3 Nos. Indoor 11kv,630A, 26.3 kA for 1 sec Load Break Switch Panel consist ofmechanical / electrical Trip bush button ,ON/OF Indicator ,Space heater with thermostat , 230V AC shunt trip coil HT HRC Fuses links with Aluminium busbar and copper earthing strip, on HVside Rigid Bus Bar interonnection to the TransformerCompletewithallinterconnection , powder coatedapproved color control wiring,earth bus ofadequate capacity & double earthing to all breakersetc.as per ElectricalInspectorate / Electrical Standards. |
| 243 | 11kV/433v,250KVA Cast Resin Transformer |
| 244 | SITC of Transformer comprising of : 11kV/433V ,250KVA ,50Hz,3phase,Vector Dyn 11 Resin Cast Indoor Transformer USS with off circuit tapping+5% to -5% in steps of 2.5% with winding temperature indicator and hooter with allstandard accessories as per IS 2026/77 on HV side Rigid Bus Bar interonnection to the 11KV LBS Panel and on LT side cable boxsuitable for 3 x 3.5 x300 sq.mm XLPE Al ; cablewith all standard fittings and accessories.Painting shall be carried out as per IS 631, impedance ofthe transformer shall be as per relevant standards. |
| 245 | NEUTRAL CTs |
| 246 | Supply & Fixing of 1no Cast Resin Neutral CT with ratio 150/5A ,15VA, Cl.5P10, fixed in a suitable M.S box with view glass. |
| 247 | HT CABLES |
| 248 | Supply of 11KV stranded compact circular aluminium conductor,conductors insulation screened withextruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.),cores laid up, inner sheath of PVC tape,galvanized steel flat strip armoured,and overall PVC sheathed cable conforming to IS 7098/11/85 with latest amendments & confirming to the GTP of Group Aof following sizes. |
| 249 | 3C - 185 Sq.mm HT Cable |
| 250 | GENERATORS |
| 251 | SITC of D.G. set of following 160 KVA 0.8 P.F.3 phase,50c/s,433V, comprising diesel engine, fuel tank, base plate,antivibration pad,battery, batterylead wire, battery charger self startingand self charging mechanism,and residential type silencer, control panel , in accoustic enclosure etc.with all standard accessoriesas per ElectricalInspectoratestandards and pollutioncontrol boardnorms. 8/10 hours of full load opration |
| 252 | 160 KVA |
| 253 | NEUTRAL CTs |
| 254 | Supply & Fixing of 1 No. Cast Resin Neutral CT fixed in a suitable M.S. box with viewglass. 150/5A, 15VA, Cl.5P10 |
| 255 | L.T.PANELS |
| 256 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doorsCRCA sheet ,duly powder coat saline resitant paint (IP65 rating) , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards) |
| 257 | MAIN MV PANELFree standing, floor mounting Switchboard fabricated out of 14SWG CRCA sheet with Top Cable entry facility at HT side for 4nos 250 KVA incomer & Cable/ Bus bar trunking facility at LT side1) Main Busbars: 400A,50KA TPN Aluminium Busbars – 1sets/sections; 2) Transformer 250 KVA Incomer: Moulded Case Circuit Breaker TP, 333A, 50KA Set 666.5A with Electronic release FD KIT, OC, SC, EF, Shunt& Isolation duty Current Limiting type – 2no4) Diesel Generator 160 KVA incomer 1 no. Metering and Indications:3Phase Digital Combination Meter with Ammeter, KW Meter, PF Meter Model EM6400 of Conserve or equivalent , 3nos Cast Resin Metering CTs, CL1,10VA 630/5, 3nos 2AControl fuses – 1setLED Type Red Yellow Blue (RYB), Red Amber Green (Close/Trip/Open) Indication Lamps with Control fuses and toggle switches – 1set3Phase Digital Voltmeter 0-500V Model DM3256 of Conzerv or equivalent and 2A Control fuses - 1setRelays: Stand by Earth fault relay 10-40% 1.3sec IDMT & 400/5 Class 10P10,15VA,415V Resin cast protection CT - 1set; AMF Relay + PLC based Synchronisation Relay5) Outgoing Feeders:Moulded Case Circuit Breaker TP, 75A, 36KA– 4nosMoulded Case Circuit Breaker TP, 250A, 36KA– 2nosIsolator TP, 400A - 1noProvision shall be made for sealing of all shutters. |
| 258 | APFC PANEL - 75 KVArSITC of APFC Panel comprising of : Incomer : 1 No. 250A, TPN, IsolatorIndication/Protection 1 SetR,Y,B LED Type Phase Indicating Lampswith 2A SP MCB as control.1 No. 8 STAGE APFC Relay. 1 Set TPN AL: Bus bars Suitably rated Outgoing 1 No.125A TP Capacitor Switching Contactor with 125 A TPN SFU withHRC Fuses Coupled with 1no 50 KVAr Capacitor. 3 No. 63A TPN SFU with 63A HRC Fuses Coupled with 3 no 25 KVAr Capacitor. 3 No.40A TP Capacitor Switching Contactorwith 40 A TPN SFU withC152:C163HRC Fuses Coupled with 3 no 10 KVAr Capacitor. 2 No.16A TP Capacitor Switching Contactor with 16 A TPN SFU withHRC Fuses Coupled with 2 no 5KVAr Capacitor. Completewithallinterconnection , powder coatedapproved color control wiring,earth bus of adequate capacity & double earthing to all switches etc.as per ElectricalInspectorate / EB Standards. |
| 259 | SSB COMMONSITC of Floor Panel comprising of :Incomer : 1No. 250A TPN Isolator; 1 Set TPN AL: Bus bars Suitably rated Metering/Indication : 1 Set.R,Y,BLED type Phase Indicating Lamps with 2A SP MCB as control. 4Nos.MFDM (KW,KWh,V, A,F ); 3 Nos .500/5A,CL:1, 15VA CTs Outgoing: 3 No. 100 A 25kA TP MCCB; 1 No.200 A 25kA TP MCCB; 2 Nos.100 A 25kA TP MCCBas outgoing;1 No . as Spare. Completewithallinterconnection , powder coatedapproved color control wiring,earth bus of adequatecapacity & double earthing to all switches etc.as per ElectricalInspectorate / EB Standards. |
| 260 | UTILITY PANELSITC of Floor Panel comprising of :Incomer : 1No. 60A TPN Isolator; 1 Set TPN AL: Bus bars Suitably rated Metering/Indication : 1 Set.R,Y,BLED type Phase Indicating Lamps with 2A Control fuse as control. 3 Nos.MFDM (KW,KWh,V, A,F ); 3 Nos .500/5A,CL:1, 15VA CTs Outgoing:2 Nos.100 A 25kA TP MCCB; 4 Nos.100 A 25kA TP MCCB; 1No. 100A TP Isolator as outgoing;1 No. as Spare. Completewithallinterconnection , powder coatedapproved color control wiring,earth bus of adequatecapacity & double earthing to all switches etc.as per ElectricalInspectorate / EB Standards. |
| 261 | UPS PANEL - 10 KVASITC of UPS PANEL comprising of : Incomer : 1 No. 63, TPN Isolator. 1 Set.R,Y,BLED type Phase Indicating Lamps with 2A Control fuse as control . 1 Set TPN AL: Bus bars Suitably rated Outgoing : 2 Nos. 40 A, 4P,RCBO; 2 Nos. 25 A, DP,RCBO ; Completewithallinterconnection , powder coatedapproved color control wiring,earth bus of adequatecapacity & double earthing to all switches etc.as per ElectricalInspectorate / EB Standards. |
| 262 | PUMP PANELSITC of Floor Panel comprising of :Incomer : 1No. 75A TPN Isolator; 1 Set TPN AL: Bus bars Suitably rated Metering/Indication : 1 Set.R,Y,BLED type Phase Indicating Lamps with 2A Control fuse as control. 3 Nos.MFDM (KW,KWh,V, A,F ); 3 Nos .100/5A,CL:1, 5VA CTs Outgoing: 4 Nos. 25 A TP MCB; 3 Nos. 16 A TP MCB as outgoings.;coupled with: 1 Nos. Star/Delta Starters (upto 14 KW) with: 1 Sets. \"ON\" \"OFF\" luminous Push Buttons with 1NO- 1NC contacts. 1 No . 25 A TP MCBas Spare. Completewithallinterconnection , powder coatedapproved color control wiring,earth bus of adequatecapacity & double earthing to all switches etc.as per ElectricalInspectorate / EB Standards. |
| 263 | SUPPLY OF LT CABLE |
| 264 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 265 | 1 X 240 sq. mm |
| 266 | 3 X 4 sq. mm |
| 267 | 3½ X 25 sq. mm |
| 268 | 3½ X 35 sq. mm |
| 269 | 3½ X 50 sq. mm |
| 270 | 3½ X 70 sq. mm |
| 271 | 3½ X 95 sq. mm |
| 272 | 3½ X 150 sq. mm |
| 273 | 3½ X 185 sq. mm |
| 274 | 4 X 6 sq. mm |
| 275 | 4 X 10 sq. mm |
| 276 | 4 X 16 sq. mm |
| 277 | 4 X 25 sq. mm |
| 278 | WIRING |
| 279 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 280 | Group C |
| 281 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 282 | Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copperconductorsingle core cable in surface / recessedmedium class PVC conduit,with modular switch, modular plate,suitable GI box and earthing the point with 1.5sq.mm.FRLS PVCinsulatedcopper conductor single core cable etc. as required for; |
| 283 | Two light controled by one switch. |
| 284 | Three light controled by one switch. |
| 285 | Four light controled by one switch. |
| 286 | Five light controled by one switch. |
| 287 | S\" type M.S. fan hook fabricated from suitable dia. M.S/S S. rod duly painted for fixing of ceiling fan. The \"S\"/U type hook shall be fixed to steel bar in RCC ceiling. The ceiling shall be replastered with sand, cement & neeru etc. The cost of labours for chipping out ceiling upto steel bar & fixing of \"S\"/\"U\" hook & resurfacing the ceiling is included in the cost of item |
| 288 | CABLE TRAYS |
| 289 | FRP Cable Tray |
| 290 | Supply of the following sizes of Ladder Type FRP cable trays with vertical sides on both ends as per approved design and FRP supports with coupler plates spaced 300mm apart throughout the length as specified, including the cost of support hooks, fasteners, painting if required etc.( Contractor shall ensure to use corrossion free materials as support or fastening fittings) |
| 291 | 150mm(150x100x25) |
| 292 | 300mm(300x100x25) |
| 293 | 600mm(600x100x25) |
| 294 | LIGHT FITTINGS / FANS |
| 295 | SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans |
| 296 | LED Downlight Surface mountFitting 60 W-60*60 cm |
| 297 | LED Downlight Surface mountFitting 20 W-20*20 cm |
| 298 | LEDRecessedLuminaire 36Watts |
| 299 | LED Linear Fixture 20Watts 4ftSurface Mounted |
| 300 | Mirror Light 5W |
| 301 | Ceiling Fan -1200 mm ( BLDC) |
| 302 | Exhaust Fan-450 mm-350 cfm |
| 303 | Bollard Lights |
| 304 | 50W Flood Light |
| 305 | 80W Flood Light |
| 306 | LIGHTNING PROTECTION |
| 307 | Air Terminal |
| 308 | Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3. For 1,2,3,4 meter air terminal 16mm rod tapered to 10 mm aluminium rodmeter rod: Meets the requirement (IS/IEC 62305). Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. System consist of Fang Fix with base and clamp on the top air terminal is erected. Air terminal Joining Clip Stainless Steel SS 304 clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. Stainless Steel Wall Clamp or 16 KG stone of 365 mm diameter, high level of stability.No. of stones/wall clamps depending on wind load. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 309 | 2meterairterminalwith Interception Tip mountedon Stainless Steel WallClamp mounting accessories. |
| 310 | Parapet / Down Conductors |
| 311 | Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below:Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 312 | Conductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters |
| 313 | Conductor with Terrace Conductor Fibre Reinforce Concrete holder @ every 0.75 meters |
| 314 | T-Connectors |
| 315 | ProvidingandfixingofCrossConnector/TConnector/FoldingClamp/ClampingShoe/ Expansion Piece: to route vertical down conductor /mesh formation made ofAluminiumFerruleusingscrewfreejoints.FoldingClamp/ClampingShoeformetalpanels(upto 20mmthicknessofthemetalframe):Foldingclamp/clampingshoeformetalframe thicknessupto20mm,madeofstainlesssteelSS304/316grade, conformstothe requirements accordingto (IS/IEC 62305). Expansion piece with connector:Forequalising temperaturerelatedlengthchanges.Necessaryonconductorslengthat every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: usingAluminiumFerrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC62305).Makesurealljointsare strong and willbe inspectedatsite.GalvanisedIronjointsarenotpermittedtoavoidriskofcorrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 316 | Test Joints |
| 317 | Providing and fixing of Stainless Steel Test Joint suitable with suitable Outdoor Enclosure: For 8mm dia solid round aluminium conductor & 10mmdiacopper coated solidsteel roundconductorhaving100micronsofcopperbonding.Conformstotherequirements according to(IS/IEC62305).Theenclosureshouldbeoutdoorglass-fibrereinforcedpolycarbonate opaque having minimum inner dimension of 75mm x 75 mm x 50 mm. Thetestlinkhastobestraightandneedsminimum4mountingscrewsforstrongjoints Inspection of bimetallic corrosion at site required. Seperation of 8mm Aluminium & 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors permitted. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 318 | Ring Earthing |
| 319 | Providingandlayingcoppercoatedsteelsolidroundconductor10mmdiameterfrom earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotentialbonding.AftertestlinkneedstoberoutedinsideHeavydutyconduittoavoid touch potential till ground level. Govt approved Indian labs test certificate required.Make: Cape/Dehn |
| 320 | Welded Joints |
| 321 | Installation of Exothermic WeldJoints for 10mm round copper bonded steel conductor having 100 microns as per IS/IEC 62305.Each under ground joints has to be wrapped withpetrolatum- coatedchemicalfibrefabrichaving1.1mmthickandwidth 50mm. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 322 | Earth Pits |
| 323 | Providingandfixingofmaintenance freeEarthingsystemcomprises ofmolecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250microns asper UL 467. The Rod has to be either continuous or with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend testwith out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016.Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg & bore arrangement rod needs Impactpoint onthe bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollutethe environment and non corrosiveto earth rod. Thematerial shouldhave aresistivity less than0.2Ωm. It should be free from hazardous substances.The mineral compound is required to have minimum 17.5 Kg ofthe total composite.The compound should be chemically inert and needs to submitGovt approved Indian labs test certificate. Concrete Earth electrode inspection chamber with weight bearing capacity of 50KN. The dimension shall be 320mmx 320mmx 190mm. Govt approvedIndianlabstestcertificaterequired. Make: Cape/Dehn |
| 324 | Solar Street Lights |
| 325 | SITC ofSolar Street Lightmounted on 2.5 inch dia. 5 meter height G.I Post comprising of :60W Monocrystalline panels , 26Ah Gell Battery , 15 Watts LED Street Light, Powder doated battery box and automatic ON/OFF Sensor etc. complete. |
| 326 | Supply, installation, testing, and commissioning of a 40 kW Grid-Tied Solar Photovoltaic Power System comprising high-efficiency mono/polycrystalline solar PV modules of minimum 370 Wp capacity each, mounted on corrosion-resistant Hot Dip Galvanized (HDG) module mounting structures suitable for RCC roof/ground type installation. The solar inverter shall be three-phase, with MPPT-based power conditioning unit (PCU) having integrated protections, remote monitoring capability (Wi-Fi/GPRS), and grid-synchronization features, capable of handling complete 40 kW load at rated efficiency. The scope shall include supply and laying of appropriate size DC/AC solar cables, weatherproof AJB and DCDB with SPDs, MCBs, fuses, and isolators, solar LT panel with protection devices, net metering arrangement with bi-directional energy meter as per DISCOM norms, and provision of suitable earthing pits for DC, AC, and LA protection using GI/copper strips and electrodes. The work shall also include all associated civil works like RCC pedestals for structure mounting, foundation for inverter panels, cable routing, and all necessary fittings, accessories, and hardware, complete in all respects as per approved design, make, and quality, and as directed by the Engineer-in-Charge. |
| 327 | 40 KW Common load |
| 328 | UPS |
| 329 | 10 KVA UPS - Three Phase |
| 330 | SITC of10kwFrame with 3.4kw x 3 modules threephase in and out. Withindoor (IP21) with surge protection system with60 min backupbattery @ 10kva .8 PF loadwithmin VAH of16320 Dual string(SMF battery of reputed approvedmake. Input pf >0.99,with externalinput isolationtransformer, with IGBTrectifier andinverterDouble conversiontechnology, with inputvoltage range 320-460 @ full load, 50Hz Three Phase, output400V, 50HzThree phase, compatibility etc. |
| 331 | CCTV |
| 332 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 333 | Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required. |
| 334 | one run |
| 335 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 336 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 337 | DATA |
| 338 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 339 | Supplying and fixing of 32 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 340 | Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required. |
| 341 | 1 or 2 Module (75mmX75mm) |
| 342 | Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required. |
| 343 | one run |
| 344 | TELEPHONE |
| 345 | Supplying and drawing 2 pair, 0.5 sq mm FR PVC insulated copper conductor, un armoured telephone cable in the existing surface/recessed steel/ PVC conduit. |
| 346 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 347 | Supplying and fixing of 32 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 348 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 349 | Telephone socket |
| 350 | Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required. |
| 351 | 1 or 2 module( 75 mmx75 mm) |
| 352 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 353 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 354 | TV |
| 355 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required |
| 356 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 357 | Supplying and fixing of 32 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 358 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 359 | TV antenna socket outlet |
| 360 | Supplying and fixing following size/ modules,GI box along with modular base, cover plate for modular switches in recess etc as required. |
| 361 | 1 or 2 module( 75 mmx75 mm) |
| 362 | CCTV |
| 363 | Supply, installation, testing and commissioning ofIP based IRVarifocal dome Camera, 1/3\" CMOS, 3 MP, 2.7–12 mm MFZ, night vision compatible,IR range of 40 mtrs PoE, inbuilt micro SD card,Ethernet port, H.264, IP 66, ONVIF, UL, FCC & CE certified. All mounting accessories shall be included |
| 364 | Supply, installation, testing and commissioning ofIP based IRbullet Camera, 1/3\" CMOS,3 MP,night vision compatible,IR range of 40 mtrs PoE,inbuilt micro SD card,Ethernet port, H.264, IP 66, ONVIF, UL, FCC & CE certified. All mounting accessories shall be included |
| 365 | Supply, installation, testing and commissioning ofIP based IR PTZ camera, 1/3\" CMOS, 2 Megapixel,30X zoom, WDR,IR range of 200 Meters, inbuilt micro SD card,,Ethernet port,TDN, PoE, DWDR, BLC, AGC, DNR, OSD,H.264 High Profile dual-stream, ONVIF, Wall/corner Mount, IP-66. CE, FCC, C-Tick certified. All mounting accessories and mounting arm suitable for the location shall be included |
| 366 | Supply,installation, testing and commissioning of IP Network Video Recorders 16 channel with 16 ports, 2 SATA, audio 1 input 1 output, video 1 HDMI 1 VGA, recording resolution 5MP/3MP/1080P, 720P/ D1 @ 30 fps, network throughput 200 Mbps from IPC and 128 Mbps to Client, Smart search supported, Remote access by DDNS & P2P, 4 channel alarm input and 2 channel relay output, 2 USB ports, ONVIF, UL & CE certified. |
| 367 | Supply, installation, testing and commissioning of 20 100/1000 SFP ports + 4 Combo 10/100/1000BASE-T/SFP ports + 4 10G SFP+ ports, L2 Management Switch - Core Switch |
| 368 | Supply, installation, testing and commissioning of 8 port- Edge PoE switch |
| 369 | Supply, installation, testing and commissioning of 24 port- Edge PoE switch |
| 370 | Supply, installation, testing and commissioning of Patch Panel UTP Keystone- 24 Port- Fully loaded (Cat 5e,Cat 6 & Cat 6 A ) |
| 371 | Supply and installation of Cat 6 UTP patch cord, 1 mtr |
| 372 | Supply, installation, testing and commissioning of Server PC, Intel i7 processor, 24 inch LED monitor, Gigabit LAN port, USB port, 8GB DDR3 RAM,1TB HDD,1GB dual graphic card, 100/1000 LAN ports, optical mouse, Keyboard, DVD Writer. Genuine Win 8.1 Pro - Down grade to Win 7 professional, 24 inch LED monitor |
| 373 | Supply, installation, testing and commissioning of Professional Joystick designed for Surveillance application as compatible with the above mentioned system. UL+CE+FCC certification minimum. |
| 374 | Supply, installation, testing and commissioning of Surveillance/ ESATA compatible Hard Disk of 4TB capacity to achieve the total storage for the NVR server |
| 375 | Supply, Installation, Testing & Commissioning of 42 inch full HD LED monitor with resolution 1920X1080 pixel including wall mounting accessories (location: security room & central control room).Material shall be UL/CE listed |
| 376 | Supply and installation of wall mounted 22U rackincluding cable manager, power supply units etc.to accommodate NVR, ethernet switch patch panel etc in control rooom |
| 377 | Supply of the following sizes of Ladder Type FRP cable trays with vertical sides on both ends as per approved design and FRP supports with coupler plates spaced 300mm apart throughout the length as specified, including the cost of support hooks, fasteners, painting if required etc.( Contractor shall ensure to use corrossion free materials as support or fastening fittings) |
| 378 | 150mm(150x100x25) |
| 379 | 300mm(300x100x25) |
| 380 | PA SYSTEM |
| 381 | Supply, installation, testing & commissioning of column speaker6 watts |
| 382 | Supply, installation, testing & commissioning of 6 watts ceiling speakers |
| 383 | Supply, installation, testing & commissioning of voice alarm call Station with all cables and accessories |
| 384 | Supply, installation, testing & commissioning ofvoice alarm keypad - Extension to voice alarm call station with all cables and accessories |
| 385 | Supply, installation, testing & commissioning of voice alarm controller with all cables and accessories |
| 386 | Supply, installation, testing & commissioning of voice alarm router with all cables and accessories |
| 387 | Supply, installation, testing & commissioning of 480 W Booster Amplifier with all cables and accessories |
| 388 | Supply, installation, testing & commissioning of DVD/MP3Player for audio playback only |
| 389 | Supply, Installation, Testing & Commissioning of Paging Microphone, goose neck type |
| 390 | Supply, laying and termination ofShielded Cat6 cable with all necessary accessories |
| 391 | Supply, laying and termination of2 Core x 1.5Sq.mm ArmouredAl.Mylar Screened FRLS Twin Twisted PVC Insulated cable along with all accessories. Accessories include cable glands, locknuts,saddle clips, cable tie & other hardwares to achieve cable termination and installation. Cable shall be terminated in speakers and amplifiers |
| 392 | Supply, installation, testing & commissioning of standard AV rack with 600mm Width, 800 mm Outer Depthand 36U Height |
| 393 | DATA SYSTEM |
| 394 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 395 | RJ 45 socket |
| 396 | Supply and installation of Cat-6 shuttered 24 port patch panel |
| 397 | SITC of24 portunmanaged ethernet switch |
| 398 | Supply and installation of 9U rack withFront glass door, Rear Perforated door with handle Lock & key. Front/Rear 19\" mounting angles, top, bottom open, RAL 9005 with all other accessories |
| 399 | AX3600 WIFI6 Dual Band Multi Band Multi Gigabt Ceiling Mount Access Point / EAP660HD |
| 400 | Supply of the following sizes of Ladder Type FRP cable trays with vertical sides on both ends as per approved design and FRP supports with coupler plates spaced 300mm apart throughout the length as specified, including the cost of support hooks, fasteners, painting if required etc.( Contractor shall ensure to use corrossion free materials as support or fastening fittings) |
| 401 | 150mm(150x100x25) |
| 402 | 300mm(300x100x25) |
| 403 | TELEPHONE SYSTEM |
| 404 | Supply,laying and termination of 20 pair telephone cable, 0.5mm copper PVC insulated,unarmoured telephone cable drawn in the existing cable tray |
| 405 | Supply,laying and termination of 20 pair telephone terminal block housed in engineering plastic box with transparent hinged door |
| 406 | Supply,laying and termination of 10 pair telephone cable, 0.5mm copper PVC insulated,unarmoured telephone cable drawn in the existing cable tray |
| 407 | Supply,laying and termination of 10 pair telephone terminal block housed in engineering plastic box with transparent hinged door |
| 408 | Supply of the following sizes of Ladder Type FRP cable trays with vertical sides on both ends as per approved design and FRP supports with coupler plates spaced 300mm apart throughout the length as specified, including the cost of support hooks, fasteners, painting if required etc.( Contractor shall ensure to use corrossion free materials as support or fastening fittings) |
| 409 | 150mm(150x100x25) |
| 410 | 300mm(300x100x25) |
| 411 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:17.1.1White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 412 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 413 | FIRE HYDRANT SYSTEM |
| 414 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cisternMake: Jaquar, Kohler, Grohe, Cera high end series. |
| 415 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Make: Safeguard, Minimax, New Age |
| 416 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 417 | Providingandfixingstainlesssteeltoiletpaperholder. Make:Jaquar,Kohler, Grohe, Cera high end series. |
| 418 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore.Make:Jaquar, Kohler, Grohe, Cera high end series. |
| 419 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms |
| 420 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 421 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board510x1040 mm bowl depth 250 mmMake: Jayana, Nirali, Carysil high end series. |
| 422 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:17.7.10Stainless Steel AISI - 304 ( 18/8/) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap. |
| 423 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore Make: Jaquar, Kohler, Grohe, Cera high end series. |
| 424 | WATER SUPPLY |
| 425 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR 11) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (Above ceiling and Ducts) |
| 426 | 15 mm nominal outer dia Pipes |
| 427 | 20 mm nominal outer dia Pipes |
| 428 | 25 mm nominal outer dia Pipes |
| 429 | 32 mm nominal outer dia Pipes |
| 430 | 40 mm nominal outer dia Pipes |
| 431 | 50 mm nominal outer dia Pipes |
| 432 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.Make: Astral, Supreme, Finolex, Prince |
| 433 | 15 mm nominal outer dia Pipes |
| 434 | 20 mm nominal outer dia Pipes |
| 435 | 25 mm nominal outer dia Pipes |
| 436 | 32 mm nominal outer dia Pipes |
| 437 | ProvidingandsupplyingISImarkCID/FButterflyValvesasperIS:13095 (Latest Edition) of PN 10 and 50 mm diameter including all taxes, insurance, transportation,freightcharges,octroi,inspectioncharges,loading, unloading, conveyance to departmental stores, stacking etc. complete. |
| 438 | ProvidingandsupplyingISImarkCID/FButterflyValvesasperIS:13095 (Latest Edition) of PN 10 and 65 mm diameter including all taxes, insurance, transportation,freightcharges,octroi,inspectioncharges,loading, unloading, conveyance to departmental stores, stacking etc. complete. |
| 439 | ProvidingandsupplyingISImarkCID/FButterflyValvesasperIS:13095 (Latest Edition) of PN 10 and 100 mm diameter including all taxes, insurance, transportation,freightcharges,octroi,inspectioncharges,loading, unloading, conveyance to departmental stores, stacking etc. complete. |
| 440 | Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile of 50 mm dia |
| 441 | Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile of 65 mm dia |
| 442 | Providing and fixing Gun metal check or non-return fullway wheel valve.(E) 40mm dia. |
| 443 | Providing and fixing Gun metal check or non-return fullway wheel valve.(E) 50mm dia. |
| 444 | Miscellaneous Works |
| 445 | Excavation for foundation/utility services upto 1.5 m depth including sorting out and stackingofusefulmaterialsand disposingoffthe excavated stuff with all lead and lift.(E)HardRock |
| 446 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each depositedlayer by ramming and watering. (Ramping by manual ormechanical means) |
| 447 | Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standardweight.(i)Squaremouthtraps.(B)150mmx100mmsizePorR type(make-Local ) |
| 448 | A. SANITARY FIXTURES. |
| 449 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin counter top type 550x420mm with a 15 mm CP Brass single hole basin mixer. Make:Jaquar, Kohler, Grohe, Cera high end series. |
| 450 | Fixing, Testing and Commissioning at site Wall Mounting type water closet with P trap & its all fittings like rag bolts, solid plastic Seat cover etccomplete including cutting and making good the walls and floors wherever required,Concealed flushing cisternwith brass screws,nuts , and washers complete including cutting and making good the walls and floors wherever requiredEtc complete.Queo - (Zelos Neo+CC Sisma)/ KOHLER ESCALE K16817IN-SS-0, OR Equ. |
| 451 | Providing, Fixing, Commissioning at site Urinal Partition with Curved shaped frosted glass fixing with brass screws,nuts , and washers complete including cutting and making good the walls and floors wherever requiredEtc complete. 900x450x10 mm tk. Make: Jaquar 1110uc/ equ. |
| 452 | Providingandfixingofgrabbars300mmStainlesssteelinphysically disabledtoiletincludingallnecessaryfitting,SSScrews&Accessories etc.Complted in all manners and satisfied to of EIC. complete. Make: Jaquar,Kohler, Grohe, Hindware, Cera high end series. |
| 453 | Providing and fixing of grab bars Vertical Swing 18-8 S, type-304, 18-gauge (1mm) stainless steel tubing with satin-finish. 1–1/4 (25mm) outside diameterwallmountedinphysicallydisabledtoiletincludingallnecessary fitting, SS Screws & Accessories etc.Complted in all manners and satisfied to of EIC.complete. Make: Jaquar, Kohler, Grohe, Hindware, Cera high end series. |
| 454 | Providing, Fixing, Testing and Commissioning at site ablution Health Spray Faucet with wall hook and 1.2 mtr. Chrome plated PVC hose pipe, etc. complete in all respects. Queo - Addons/Kohler/Grohe/jaquar |
| 455 | Providing, Fixing CP Robe hook: Queo - / KOHLER/Grohe ,jaquar OR Equ. |
| 456 | Supplying,Fixing, Testing, and commissioningSink tapwall mounted/floor mounted with swivel casted spout and wall flange, trending cutting and making good the walls whatever required etc. complete Queo - Allamoda/jaquar/Kohler/Grohe |
| 457 | Providing and fixing Gyser 20 Ltr with flexible connectionfittings arrangement etc. complete of approved quality and make, including cost and conveyance of all materials, labour charges, lead, lift, etc. complete, as per direction of the Engineer-in-Charge at all levels. |
| 458 | B. SOIL, WASTE, VENT & RAIN WATER PIPES |
| 459 | Supplying, Fixing, testing and commissioning at site in positionuPVC pipe -6kg/cm2) (IS:4985)Solvent Welded fittings with bosses where required e.g. tees, bends, coupling, door bends, junctions, cowls, door TEE , Door Elboe where ever required etc.,complete. (Soil & Waste in Shaft) Make: Astral/Supreme/Ajay |
| 460 | 110 mm O.D. (6Kgf/cm2 IS:4985) |
| 461 | 75 mm O.D.(6Kgf/cm2 IS:4985) |
| 462 | 63 mm O.D( 4Kgf/cm2) Vent pipe in shaft |
| 463 | Providing, Fixing, testing and commissioning at site in position uPVC pipe( IS : 4985 ) With Rubber Ring or Solvent Welded fittings with bosses where required e.g. tees, bends, coupling, etc. complete. (For Rain water pipes in shaft & Ceiling) Make: Astral/Supreme/Ajay |
| 464 | 110 mm O.D( 4Kgf/cm2)) Rain water pipe in shaft |
| 465 | Supplying, Fixing, testing and commissioning at site in position u PVC pipe of 6Kgf/cm2including PVC fittings with bosses where required e.g. tees, bends,door TEE , Door Elboe where ever requiredcoupling and adapters and jointing with adhesive approved by fitting manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site universal clamps & anchor fasteners(8mm) , threaded rod(8mm),nuts ,washers, wherever required etc. complete.Make: Astral/Supreme/Ajay |
| 466 | 40 mm O.D. (6Kgf/cm2 IS:4985) |
| 467 | 50 mm O.D. (6Kgf/cm2 (IS:4985) |
| 468 | 75 mm O.D. (6Kgf/cm2 (IS:4985) |
| 469 | 110mm O.D (6Kgf/cm2 (IS:4985) |
| 470 | 32 mm O.D. (8Kgf/cm2 (IS:4985) for sunken spout |
| 471 | Supplying, Fixing, testing and commissioning at site in position Deep Seal UPvc fabricated Multi floor trap (4”), with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, anchor fasteners etc. complete in all respects.50/75 mm dia outlet (In Ceiling)Astral/Supreme/Ajay |
| 472 | Supplying,Fixing, testing and commissioning at site in position UPvc fabricated Multi floor trap (7”),with 50/75 mm dia outlet (In Sunken slab & floor raising areas)Astral/Supreme/Ajay |
| 473 | Supplying,Fixing, Testing and commissioning at site in position 150x150mm square C.P cast brass or stainless steel anti cockroach grating cover ss (304) of matching size of UPvc fabricated floor trap / multi inlet trap complete in all respects. Chilly/Eligna/ |
| 474 | Supplying,Fixing, Testing and commissioning at site in position 150x150mm square C.P cast brass or stainless steel sealed grating cover ss (304) of matching size of UPvc fabricated floor trap / multi inlet trap complete in all respects. Chilly/Eligna/ in common toilets |
| 475 | Supplying,Fixing, testing at site in position 160mm dia square /circular grating Terrace rain water outlet(Cast Iron)(for 110mm dia pipe) |
| 476 | Supplying, Fixing, testing at site in position PVC Roding Eye (6kg/cm2) Complete in all respects. |
| 477 | 110 mm dia |
| 478 | 75 mm dia |
| 479 | Providing and fixing in position cowel went to pipes.(C) 100mm dia |
| 480 | Providing, Fixing at sitein position uPVC Pipes (as per ASTMD – 1785 sch-40 ) of approved make For Cold Water Supply, complete with all necessary (ASTM D – 2466/2467) fittings (elbows, unions, tees, reducers, couplings, nipples etc) (External/ Inshaft) |
| 481 | 1 ¼ “ (32mm) dia. |
| 482 | 1 1/2 “ (40mm) dia. |
| 483 | 2” (50mm) dia(External / in Shaft) |
| 484 | 2 ½” (65mm) dia(External / in Shaft) |
| 485 | Supplying,Fixing at site in position full way lever operated forged brass gate valve of brass body with forged brass hard crome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings |
| 486 | ½ \"\"(15mm) dia.Globe valve |
| 487 | ¾ \"\"(20mm) dia. |
| 488 | 1” (25mm)dia |
| 489 | 1 ¼ “ (32mm) dia. |
| 490 | 1 1/2 “ (40mm) dia. |
| 491 | 2” (50mm) dia |
| 492 | Supplying, Fixing, testing and commissioning at site Puddle Flangefabricated from Upvc ASTM Grade sch-40 pipes & uPVC sheet (600 mm long) |
| 493 | 1 ¼ “ (32mm) dia. |
| 494 | 1 ½” (40mm) dia(External / in Shaft) |
| 495 | 2” (50mm) dia(External / in Shaft) |
| 496 | 2 ½” (65mm) dia(External / in Shaft) |
| 497 | 3” (80mm) dia(External / in Shaft) |
| 498 | 4” (100mm) dia(External / in Shaft) |
| 499 | 6” (150mm) dia(External / in Shaft) |
| 500 | 8” (200mm) dia(External / in Shaft) |
| 501 | Supplying, Fixing, testing and commissioning at site Puddle Flangefabricated from GI pipe with 6mm tk plate (600 mm long) for FIRE Tank |
| 502 | 4” (100mm) dia-GI,single side flange |
| 503 | Drilling with core cutting machine in RCC beams, slabs floors etc., for laying pipes and rendering the same in RCC 1:2:4,finishing the same to the satisfaction of the Owner or his authorized representative etc., including nominal reinforcement wherever required, complete. The quoted rate shall also include for providing (conbextra GP -2/GP – 10) based water proofing compound for sealing the joints around the pipes. (Slab Thickness – 10cm / 12cm) |
| 504 | RCC Slabs (For Wash Basin, EWC & Floor Trap) |
| 505 | 125 MM DIA |
| 506 | 90 MM DIA |
| 507 | 65 MM DIA |
| 508 | 50 MM DIA |
| 509 | 40 MM DIA |
| 510 | Providing,fixing,jointingandtesting,heavyquality caststeel /Brass Air Release Valve designed ofapproved make, including flanges / unions, nuts, bolts, washers, etc. complete, as per I.S 5212 approved by the Engineer-in-charge for water supply lines of the following nominal bore (NB)size: 20mm diameter. Make:ZOLOTO/VTC/SANT |
| 511 | D.EXTERNAL SEWERAGE |
| 512 | Supplying and Laying of pipes and conveying to position; cleaning, laying and jointing to true lines and gradients,with proper bedding uPVC pipe of IS 4985(6kgf/cm2)including jointing the pipe as per specification, testing the pipe line after installation all per provisions of IS: 1742-1983 (Code of practice for building drainage) complete as directed by the Employer |
| 513 | 110 mm OD (6/kg/cm2) |
| 514 | 160 mm OD (6/kg/cm2) |
| 515 | STORM WATER DRAINAGE |
| 516 | Providing and supplying of Class SN8Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smoothExternalAnnularCorrugatedandSmoothInternalSurfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as per EN:13476-3 including all local and central taxes, transportation,freightcharges,octroi,inspectioncharges,loading, unloading, conveyance to the departmental stores etc. complete.(ID 150 mmdiameter) Make: Astral, Supreme, Finolex, Prince |
| 517 | 160 mm OD (6/kg/cm2) |
| 518 | 200 mm OD (6/kg/cm2) |
| 519 | Supply, installation, testing and commissioning of percolation well (Recharge well) including all work like drilling, compressor work, gravel packing, mud slurry disposal, clay packing and including of all materials like 300mm UPVC pipe, 300mm wire screens, 300mm collar joint, accessories, gravels, sand, sand filteration module etc. Site cleaning, mud pit, mud refilling for borewell must be in the contractor\"sscope.Contractorhastomaintainthepercolationwellupto three years after installation. |
| 520 | F.PUMP AND ACCESSORIES |
| 521 | Supply,Installation, Testing and commissioning of Clear water transfer open well submerssible pump of adiquate hp with discharge 3 lps at 20 mtr head, SS body, ss shaft with bronze impeller mounted on a single base platewith controll panel and auto level controller. |
| 522 | 1 working+ 1 stand by |
| 523 | TERRACE DWS BOOSTER PUMP Duty Conditions of 6 lps @ 35 mtr - head(Each pump 3LPS 35 mtr Head - 1 Pump system-1 WorkingCompact skid mounted Booster pumps with SS 304 casing, SS316 impeller , SS316 shaft , C I base and TEFC motorwith mechanicalseal. Pumpto be havesingle VFD logic controller. - Electriccontrol panel withlogic controller, relays, calibrated pressure switch, pressuretransmitter including cabling within panel, incorporating dry run protection, potential contacts forBMS integrating , sucton and discharge headers, pressure vessal 60 ltr capacity. |
| 524 | Supplying and fixing of Borewell /tube well submerssible pump with panel, with CIconstruction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and50 Hz frequencyalong with pump protection starter with in built level controller for automatic operation of pumpset using float switch , The panel should have LCD screen showing Voltage / Ampere, Error log, Cascading operation , Pump run status , Auto faulty pump change over, Auto- Manuel selection etc . The panel should protect the pumpsetfrom over and under voltage, over and under load, dry protection , Phase reversal protection , Single phase prevention etcincluding cost and conveyance of all materials,labour charges etc complete as directed by the Engineer-in-Charge at all levelsCapacity :7m3/hrHead : 55 m |
| 525 | Supplying and fixing of Horizontal open well SUBMERCIBLE pump(1W+1S)ug to oht, with CIconstruction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and50 Hz frequencyalong with pump protection starter with in built level controller for automatic operation of pumpset using float switch , The panel should have LCD screen showing Voltage / Ampere, Error log, Cascading operation , Pump run status , Auto faulty pump change over, Auto- Manuel selection etc . The panel should protect the pumpsetfrom over and under voltage, over and under load, dry protection , Phase reversal protection , Three phase prevention etc -Capacity :24 m3/hrHead : 32 m |
| 526 | WATER TREATEMENT PLANT |
| 527 | PRIMARY CHILLED WATER PUMP |
| 528 | Supply, installation, testing and commissioning of Primary CHW Pumpset- Constant speed Centrifugal Back pull out ,long coupled ,end suctionPUMPS, factory mounted base frame with electric motor for recirculation of water for the central air conditioning system with eleactrical panel and cabling between pump and panels. All pumps shall be aligned properly as required. The pump motor shall be suitable for 415 + 10% volts, 1440Rpm,50 cycles, 3 phase power supply. The Quoted price should be inclusive of mechanical seal including SS 316gland plate, Bronze Impeller, Coupling gaurd & with performance characteristics as given below : Primary CHW pumps: 3 Nos. (2 working + 1 No. Stand by) Flow rate = 144 USGPM Head = 10 Mtr |
| 529 | Hot Water Generation & Circulation |
| 530 | Providing,fixing,jointingandtesting,heavyquality caststeel /Brass Air Release Valve designed ofapproved make, including flanges / unions, nuts, bolts, washers, etc. complete, as per I.S 5212 approved by the Engineer-in-charge for water supply lines of the following nominal bore (NB)size: 20mm diameter. Make:ZOLOTO/VTC/SANT |
| 531 | Miscellaneous Works |
| 532 | Constructing Brick masonry road Inspection chamber 450mm x 450mm x 775mm with horizontal grating complete.C.M.1:6.Foundation concrete150 mm thick in C. C.1:4:8oftrap metalsize 25mm to40mm thick, inside cement plaster in C. M. 1:3 and cement pointing outside in C. M. 1:3 and ms gratings on top. Upto 1 Mt. depth from G. L. to pipe invert level incl. complete civil works but excl. cost of excavation and refilling, with cast in situ RCC slab in one single piece with fixing of DI/FRP-MH Frame and cover (incl cost of DI/FRP-MH Frame and cover) with 23 mm thick brick masonry wall in C.M.1:6.With precastslab in two parts 15mm. for rain water/storm water drainage |
| 533 | Construction of Manhole chambers(Inspection chambers) 600mm X 600 mm and depth 1.0 m in brickorbelastonemasonry,locallyavailableinC.M.1:6.Foundation concrete150 mm thick in C. C.1:4:8oftrap metalsize 25mm to40mm thick, inside cement plaster in C. M. 1:3 and cement pointing outside in C. M. 1:3 and top cover of precast RCC slab 100 mm thick (with key hole in two parts, each with handles or MS Bar etc. complete as given size) Upto 1 Mt. depth from G. L. to pipe invert level incl. complete civil works but excl. cost of excavation and refilling, with cast in situ RCC slab in one single piece with fixing of DI/FRP-MH Frame and cover (incl. cost ofDI/FRPI-MH Frame and cover) with 23 mm thick brick masonry wall in C.M.1:6.With precastslab in two parts 15mm. |
| 534 | Extra over items above for every additional depth of 0.1M. of part thereof beyond 450mm depth for Brick masonry chamber.(i) |
| 535 | ProvidingandfixingDI/FRPcoverwithframe(Medium duty)600x600mm , total weight of cover and frame to be not less than 108kgFOR SUMP TANKS |
| 536 | ProvidingandfixingDI/FRP.coverwithframe(Light duty)600x600mm , total weight of cover and frame to be not less than 23 kg for OHT |
| 537 | Supply, installation,testing and commissioning of Grease Chamber round type havingcapacity of 400-750 litter. The separator for greasy wastewater is suitable for installation in the ground and comes without metallic components in the tank. The collecting tank made of permanently resistant polymer (PE) is equipped with an integrated sludge trap and has a rounded base for fast and clean disposal. Access for cleaning and maintenance work is possible via one or several service access covers. A direct disposal pipe socket shall be available for odour-reduced manual disposal. A load distribution slab must be installed on site for load class D. The reinforcement shall be provided as per OEM specification . installation depth 550-900 mm,net weight not less than130 kgand gross wight not leass than 137 kg |
| 538 | Supply and fixing ofDRAINAGE GRATING WITHTROUGH, 30x30x8+10• Trough using 1 mm thick 304grade #4 stainless steel• Grating using 2 mm thick 304grade #4 stainless steel |
| 539 | Supply and fixing ofDRAINAGE GRATING WITHTROUGH, 60x30x8+10• Trough using 1 mm thick 304grade #4 stainless steel• Grating using 2 mm thick 304grade #4 stainless steel |
| 540 | Providing, Supply, installation,testing and commissioning of UPVC Oil Wastesystem conforming to DIN-EN-12056 & DIN-1986-100 fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offSet and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints. Pipes may be laid / fixed in sunken floors, under slung from ceiling. The pipes laid in sunken floor shall be encased with 75 mm thick cement concrete (1:2:4) all around. The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications. |
| 541 | 75mm Dia |
| 542 | 110mm Dia |
| 543 | IRRIGATION SYSTEM |
| 544 | Supply, laying & jointing in position High Density Polyethylene (H.D.P.E) Pipes,confirming to IS 4984:1995 and IS 7328:1992,(PE-80)PN-16 and suitable for the respective working pressures without all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers\" instruction.The rate shall including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-ChargeMake:- Supreme |
| 545 | 65mm-Dia-PN-16 |
| 546 | 50mm-Dia-PN-16 |
| 547 | 40mm-Dia-PN-16 |
| 548 | 32mm-Dia-PN-16 |
| 549 | 25mm-Dia-PN-16 |
| 550 | 20mm-Dia -PN-16 |
| 551 | DRIP & ACCESSORIESSupply & Fixing of flexible,kink resistant, inline tubingHigh Density Polyethylene (H.D.P.E) Pipes,confirming to IS 4984:1995 and IS 7328:1992,,(PE-80)PN-16 algae growth drip tube,with a flow rates of 2.3lph to 3.5 lph and pressure rating of 0.58 to 4.14 bar.The rate shall include cost of all required fittings and accessories like Clamps,connectors,tees,elbows,adaptor,coupling etc complete in all respect required for fixing drip tube as per approved design,make and quality as directed by Engineer-in-Charge.Make:- Supreme |
| 552 | SPRINKLERS & ACCESSORIESSupply & Fixing of Pop up spray head Spray bodies,having Co-moulded wiper seal is moulded into the cap and features like pressure-activated, multi-function seal design,with an encased plastic \"cage\" to provide unmatched resistant to grit, with high efficiency VAN Nozzle capable of covering 0.9-5.5m at 1.0 - 2.1 Bars, pressure, and the environment with proven UV resistant plastic.The rate shall include cost of all required fittings and accessories like swing joint,service saddle as per required sizeetc complete in all respect as per approved design,make and quality as directed by Engineer-in-Charge. |
| 553 | Supply & Fixing of Pop up spray head Spray bodies, with hand adjustable rotary nozzle havingmutilple streamspray having Co-moulded wiper seal is molded into the capand features like pressure-activated, multi-function seal design,with an encased plastic \"cage\" to provide unmatched resistant to grit, nozzle capable of covering 5.2-7.4m at 1.4 - 3.8 Bars, pressure, and the enviroment with proven UV resitant plastic.The rate shall include cost of all required fittings and accessories like swing joint,service saddle as per required sizeetc complete in all respect as per approved design,make and quality as directed by Engineer-in-Charge. |
| 554 | VALVES & ACCESSORIESSupply & Fixing of PN10 PVC Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem non mechanical ,with a base which permits maximum penetration into the valve of size 63mm.complete in all respect as per approved design,make and quality as directed by Engineer-in-Charge. |
| 555 | Supplying,Fixing at site in position full way lever operated forged brass gate valve of brass body with forged brass hard crome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings |
| 556 | 25 mm nominal bore |
| 557 | 32 mm nominal bore |
| 558 | 40 mm nominal bore |
| 559 | 50 mm nominal bore |
| 560 | 65 mm nominal bore |
| 561 | Supply & Fixing of a double acting 1/2 \" PVC Air release valve,The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar.complete in all respect as per approved design,make and quality as directed by Engineer-in-Charge. |
| 562 | Supply & Fixing of 18\" Rectangular Valve Box withgreenlid and corrugated structure with unique shovelaccess slot and bolt hole knockout complete in all respect as per approved design,make and quality as directed by Engineer-in-Charge. |
| 563 | Supply & Fixing of 12\"Roundbox withgreenlid and corrugated structure with unique shovelaccess slot and bolt hole knockout complete in all respect as per approved design,make and quality as directed by Engineer-in-Charge. |
| 564 | Supply & Fixing of 25mm dia brass Quickcoupling valve fittingswith ofauto close lid, SS spring, brass valvecomplete in all respect including key as per approved design,make and quality as directed by Engineer-in-Charge. |
| 565 | Supply & Fixing of Key threads into top of Quickcoupling valve to provide water access complete in all respect as per approved design,make and quality as directed by Engineer-in-Charge. |
| 566 | FIRE HYDRANT SYSTEM |
| 567 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Make: Safeguard, Minimax, New Age |
| 568 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Make: Safeguard, Minimax, New Age |
| 569 | Stainless Steel (Grade 304) |
| 570 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Make: Safeguard, Safefire, Minimax, New Age |
| 571 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.and tested to 1.2 MPA( 12 Bar pressure) installation brackets, complete in all respects including all accessories as required for complete installation. INLET PIPE CONNECTION FROM RISING MAINS TO HOSE REEL SHALL BE PROVIDED WITH GI HEAVY CLASS PIPES WITH UNIONS OR WITH READY MADE TYPE FLEXIBLE RUBBER HOSE IN STANDARD LENGTH, HYDRAULICALLY FITTED END CONNECTIONS ETC .Make: Monsher, Minimax, New Age |
| 572 | Supplying and fixing of 2 Way fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :Make: Safeguard, Safefire, Minimax, New Age |
| 573 | Providing, laying, testing & commissioning of \"B\" class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as requiredNote : Pipes up to and 50 mm dia shall be socket welded with DI fittings. For pipes inside the Fire pump room |
| 574 | 25 mm dia |
| 575 | 80mm dia |
| 576 | 100 mm dia |
| 577 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : Make : Leader/ Audco/ Zoloto |
| 578 | 80 mm dia |
| 579 | 100 mm dia |
| 580 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : Make : Leader/ Audco/ Zoloto |
| 581 | 150 mm dia |
| 582 | 100 mm dia |
| 583 | 80 mm dia |
| 584 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.Make : Leader/ Audco/ Zoloto |
| 585 | 100 mm dia |
| 586 | 200 mm dia |
| 587 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. Set |
| 588 | Supply, installation, testing and commissioning of Brass Air release valve, size 25mm with threaded inlet & provided with ball type float complete with all accessories required for complete installation. Make : Leader/ Audco/ Zoloto |
| 589 | Supply, installation, testing and commissioning of industrial type pressure switch having 1/4\" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required. Make: Infoss/ |
| 590 | FIRE PUMPS, & ACCESSORIES |
| 591 | Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in allrespects, as required :(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. |
| 592 | 450 lpm at 35 m Head Set |
| 593 | Make : Kirloskar, Mather & Platt India Limited,lubi |
| 594 | RISER SYSTEM |
| 595 | Providing and fixing GI heavy duty \"B\" class (IS: 1239 Part-1) including cutting, welding etc. and providing all fittings viz. Flanges. Bends,Tees, Elbow, Reducers, Clamps. Hangers etc. including cutting holes and chases in brick or RCC walls/slabs and making good the same to the approval of engineer/consultant complete including painting with one coat of primer and two or more coats of enamel paint of approved make and shade including steel work, GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & fire sealant compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. Note : Pipes up to and 50 mm dia shall be socket welded with DI fittings. |
| 596 | 25 mm dia |
| 597 | 65 mm dia |
| 598 | 80 mm dia |
| 599 | 100 mm dia |
| 600 | Supply, installation, testing and commissioning of electrically operated water flow switches (Vane type) dia 65 mm including tamper switch and accessories, complete with tap off socket arrangement as required, with potential free contact with 2 Nos. NO/NC including all accessories as required for complete installation. HD/ Honeywel |
| 601 | In 100mm line |
| 602 | ADDRESSABLE FIRE ALARM SYSTEM |
| 603 | Supply, Installation, Testing and Commissioning of Fire alarm control panel capable of handling 99 devices / detectors per loop to meet the NFPA Standards and UL approvals. 2 loop Panel should be expandable, with a battery backup in normal condition and in alarm condition. The panel should be expandable. |
| 604 | Make: Honeywell/Edward/Essar/Cooper |
| 605 | Supply, Installation, Testing and Commissioning of analogue addressable type Manual pull station at indicated locations with necessary termination as per the specifications and full ready for operation. |
| 606 | Make: Honeywell/Edward/Essar/Cooper |
| 607 | Supply, Installation, Testing and Commissioning of addressable sounder at different locations complete with all fixing accessories. |
| 608 | Make: Honeywell/Edward/Essar/Cooper |
| 609 | Supply and laying of 2C X 1.5 Sqmm Armoured copper conductor cable FRLS with all necessary saddles and other accessories. Make: Finolex/Polycab/Havells/KEA |
| 610 | Make: Finolex/Havells/Polycab |
| 611 | Supply, Installation, Testing and Commissioning ofShort Circuit Isolator Module for isolating the affected segment of the circuit, allowing the remaining devices to continue operation. |
| 612 | TALK BACK SYSTEM |
| 613 | 10 zone control panel for fire alarm system with following:- 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required 2 Nos. (one to act as standby) Talk back master station with LED PTT (Press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit 1 set.Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required 1 Set. Amplifier change over switch for inter changing amplifier 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required 1 No.Gooseneck microphone with stand and ON/OFFswitch 1 No. Mains ON/OFF switch, fuse indication lamps,DC and AC voltMetres & Ammetres terminal blocks etc. complete as required 1 Set. Battery charger trickle cum boost to take completeload of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries |
| 614 | Supplying, installation, testing & commissioning talk back slave station in surface/ recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/ microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. |
| 615 | Supply, installation testing and commissioning of20mm. PVC Rigid Conduits conforming to IS and specification,on walls /ceiling / floor etc. complete with all accessories like junction boxes, collars, bends etc. Make: ISI Marked |
| 616 | Supply, install, test and commission 2C x 1.0 mm PVC cable. Make: Finolex/Havells/Polycab |
| 617 | Miscellaneous Items |
| 618 | Supply and installation of Weather proof Outdoor type hose cabinets fabricated from 14 SWG M.S. sheet with full glass door with locking arrangement (Water Proof), suitable to accommodate 2 nos.15 M long hose and 1 No branch pipe. Glass will be transparent Acrylic - 3mm thick. The cabinet shall be painted with coat of P O Red paint from outside and white paint from inside including all accessories as required for complete installation.(size shall be such that the above all items can be accommodated). (Double door type) as per industrial standards |
| 619 | Supplying, laying, fitting and fixing , testing and commissioning of under ground GI heavy duty \"C\" class pipe confirming to IS 1239 The pipes shall have anti-corrosive wrapping coating and a wrapping treatment with pipe coat 4 mm thickness, after applying one or more coats of Asphalt primer. Rates shall include cutting, welding etc. bends, elbows reducers suitable for pipe joints, clamps and all other accessories including excavation of earth to sufficient depth to install the pipes, the pipes buried in ground excavation and refilling etc.as per the specification and as required complete as required for complete installation etc. including cutting holes in RCC walls/slabs and making good the same adequately supported on rigid supports duly painted as required complete in all respect including allup to building rising mains and for yard hydrants , |
| 620 | 100 mm dia |
| 621 | 80 mm dia |
| 622 | Supply & installation of Pressure Gauge with 0-300 psi (0-21Kg/Sq.CM) range white background, black graduation scale with dual reading in Kg/Sq.CM & PSI, 1/4\" BSPT bottom entry 100 MM dial, PHOSPHOROUS BRONZE bourden tube, brass moving parts, polished stainless steel case with positive seal against weather, moisture & dust, hardened glass, glycerine filled type with syphon tube and isolation cock,Make: Fiebig / H guru |
| 623 | Providing & fixing double flanged flexicon rubber expansion joint with unit control of standard length as per manufacturers specifications suitable for working pressure rated (PN16) and test pressure to be 150 % rated pressure ofincluding rubber gaskets, flanges, nuts, bolts and washers complete as required |
| 624 | 100 mm dia |
| 625 | Extinguishers |
| 626 | Supply and fixing Co2 type Fire Extinguisher of capacity 4.5 kg filled with Co2 Gas with control discharge mechanism ( squeeze grip type) fitted with Bend and Horn applicable on Class B and C class of fire. Manufactured and marked to IS 15683 with ISI marking and cylinders having the approval of Chief Controller of Explosives, and including all accessories as required for complete installation. |
| 627 | Supply and fixing of dry chemical powder type (DCP) fire extinguishers (ABC Type) of 4 Kg capacity, Pressurized with nitrogen, mfg. to IS:15683 with ISI mark fitted with pressure gauge, GM cap nozzle complete with initial charges and installation brackets and screws with ISI marks etc. complete as approved and instructed by the engineer in charge including all accessories as required for complete installation.. |
| 628 | Supply and fixing emergency exit light fixture with battery back up unit, LED Lamps, indicating Fire Exit, recess / mounted type. 24hrs x 7days working conditional. |
| 629 | Supplying andinstalling of in position the various type of sign boards made out of 3mm thick \"Opaque\" PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners. Size : 60cm x 15cm |
| 630 | Supplying,Fixing at site in position full way lever operated forged brass Ball valve of brass body with forged brass hard crome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings |
| 631 | 1” (25mm)dia |
| 632 | 2” (50mm)dia |
| 633 | Supplying,Fixing at site in position full-3way lever operated forged brass Ball valve with sight viewb glass (test and drain ) of brass body with forged brass hard crome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings |
| 634 | 2” (50mm)dia |
| 635 | Supply,erection, testing and commissioning of Automatic Motor Control Panel for the electric driven terrace pump, with DOL Starters, switch gear and contactors shall be rated for motor HP. The panel shall include necessary indicating lamps for the RYB phases, ammeters and volt meter with selector switch. etc. The panel shall have Auto/Manual Selector Switch. The panel shall be powder red in colour and shall have provision for wall mounting with all accessories as required complete. The cabling between the pump and the panel shall be provided by others. |
| 636 | HVAC SYSTEM |
| 637 | Supplying & installing M.S powder coated standard type stand mounting for outdoor unit of split A.C up to 2TR Capacity, erected with necessary hardware materials as irected. 1.75 kg for 1 set (8-3-3/151) |
| 638 | HIGH SIDE EQUIPMENTS |
| 639 | DRAIN PIPING |
| 640 | Supplying, fixing, testing and commissioning of UPVC Class E condensate drain pipe with U trap, insulation & fittings up to drain line with necessary support and accessories |
| 641 | 25mm Dia |
| 642 | VENTILATION |
| 643 | EQUIPMENTS |
| 644 | Supply, installation , testing and commissioning of metal body wall mounted proppeller fan with necessary accessories and supports |
| 645 | Providing and erecting 3 star and above rated approved make split air – conditioning unit consisting of condensing unit with fan motor, hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of proper insulated copper tubing up to 5 RMT suitable for (Cost includes S.S. Stand, Gas Charging & Internal Copper Wiring Remote Control). The outdoor unit shall comply with the saline resistance at exterme condition.Bluestar/votas/carrier |
| 646 | 1. ton capacity. |
| 647 | 1.5 ton capacity. |
| 648 | 2 ton capacity. |
| 649 | Remote control (b) Cordless remote control. |
| 650 | KITCHEN EXHAUST,FRESH AIR DUCTING AND FANS |
| 651 | Supplying, Fixing, Testing & commissioning at site in position2 HP Axial Fan for ExhaustSpecification :Fan Casing is made of heavy gauge MS Sheet (as per IS-1079/2062) having robust construction. It has flanges at both ends for easy fixing on ducts/walls. Impeller is made of Die Cast aluminium having aerofoil design with adjustable pitch angles. fitted with 2 Hp , 4 Pole, 440 volts , 50 Hz, 3 Phase Motor |
| 652 | Supplying, Fixing, Testing & commissioning at site in position1 HP Axial Fan for Fresh Air Specification :Fan Casing is made of heavy gauge MS Sheet (as per IS-1079/2062) having robust construction. It has flanges at both ends for easy fixing on ducts/walls. Impeller is made of Die Cast aluminium having aerofoil design with adjustable pitch angles. fitted with1 Hp , 4 Pole, 440 volts , 50 Hz, 3 Phase Motor |
| 653 | Supplying, Fixing, Testing & commissioning at site in positionGI Ducting with Fittings For Exhaust Specification : 22 Swg Gi Sheet Of Tata/Jindal With All Connected Accessories For Fitment Of The Duct On The Ceiling And With Hood As Per Site Layout/Site Conditions. Plat Form For Fixing Blower, Smooth Bends, Bents To Be Fixed With GI Angle And GI Suspenders Fixed On To The Ceiling/Wall With All Allied Fixing Materials. The Jointing Flanges To Be Made With 35x35x3 Mm. GI Angle. 8mm GI Rods And Painted 5mmx35mmx3mm GI Angle At An Interval Of 2mtr Shall Be Used To Suspended The Ducting On To Ceiling/Wall. Duct Joints to Be Bolted Together With Gasket for Air Tight Seal. |
| 654 | Supplying, Fixing, Testing & commissioning at site in positionGI Ducting with Fittings For Fresh Air Specification : 22 Swg Gi Sheet Of Tata/Jindal With All Connected Accessories For Fitment Of The Duct On The Ceiling And With Hood As Per Site Layout/Site Conditions. Plat Form For Fixing Blower, Smooth Bends, Bents To Be Fixed With GI Angle And GI Suspenders Fixed On To The Ceiling/Wall With All Allied Fixing Materials. The Jointing Flanges To Be Made With 35x35x3 Mm. GI Angle. 8mm GI Rods And Painted 5mmx35mmx3mm GI Angle At An Interval Of 2mtr Shall Be Used To Suspended The Ducting On To Ceiling/Wall. Duct Joints to Be Bolted Together With Gasket for Air Tight Seal. |
| 655 | Supplying, Fixing, Testing & commissioning at site in positionFresh Air Grill |
| 656 | Supplying, Fixing, Testing & commissioning at site in positionWall Mount Exhaust Hood With Baffle Filters size-1800*900*500 mm ,Exhaust Hood with filters for Bulk range & Hot plate Wall mounted type :20 SWG SS 304 body; SS 304 Baffle filters , air grill and oil collection tray |
| 657 | Supplying, Fixing, Testing & commissioning at site in positionWall Mount Exhaust Hood With Baffle Filters -size-1250*750*500 mm,Exhaust Hood with filters for Bulk range & Hot plate Wall mounted type :20 SWG SS 304 body; SS 304 Baffle filters , air grill and oil collection tray |
| 658 | GAS WORK |
| 659 | Supplying, Fixing, Testing & commissioning at site in positionGas BankSpecification : (3+3) Manifold SS 304 1/2 pipe Schedule 40 S with Necessary Fittings 3/8 needle valve unitechEmergency shutter valve 1/2\"4\" ss measure guageManifold valve ss valveNon return valve (gasman)Liquid drain filterQC adapter (gaso)Cylinder pigtail 2ft.Booster valve united 30 PSIRange connector (Lumpsum) |
| 660 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 661 | DemolishingR.C.C work manually/ by mechanical means including stacking of steel bars and disposal of unserviciable materialwith in 50 metres lead as per direction of Engineer incharge |
| 662 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical meansincluding stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :In cement mortar |
| 663 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Of area 3 sq. metres and below |
| 664 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Of area beyond 3 Sq. Metres |
| 665 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-inchargeAll kinds of soil |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail