| 1 | PROVIDING & FIXING SUN-CONTROL FILM OF APPROVED QUALITY AND SHADE AS DIRECTED BY EIC OVER GLASS DOORS / WINDOWS. |
| 2 | PROVIDING & FIXING 3 MM THICK PLAIN SHEET GLASS TO EXISTING STEEL WINDOW PANELS. RATE INCLUDES REMOVAL OF BROKEN GLASS (IF ANY) CAREFULLY, REMOVAL OF OLD PUTTY AND PROVIDING AND APPLYING NEW PUTTY ETC. COMPLETE. |
| 3 | PROVIDING AND FIXING ACRYLIC PLASTIC SHEET PANELS 2.00 MM TO 3 MM THICK OF APPROVED QUALITY IN REQUIRED THICKNESS PLAIN CLEAR OR ANY COLOUR OR OBSCURED LININGS IN LIEU OF GLASS PANS TO DOORS/WINDOWS INCLUDING PROVIDING AND FIXING CLIPS, PUTTY ETC. COMPLETE. |
| 4 | PROVIDING AND FIXING PLAIN/FLOAT GLASS PLANES OF 5.00MM THICKNESS (WEIGHT NOT LESS THAN 12.5KG/SQM) IN OLD ALUMINIUM DOOR, WINDOW, VENTILATOR, SHUTTERS AND PARTITIONS ETC.M WITH EPDM RUBBER/ NEOPRENE GASKET, USING EXISTING ALUMINIUM SNAL BEADING ETC., COMPLETE AS PER DRECTIONS OF EIC. |
| 5 | PROVIDING AND FIXING ANODIZED ( TRANSPARENT OR DYED TO REQUIRED SHADE ACCORDING TO IS: 1868. MINIMUM ANODIC COATING OF GRADE AC 15) ALUMINUM SECTIONS FOR FIXED/ SLIDING / PIVOTED / TOP HUNG / SIDE HUNG / LOUVERED TYPE WINDOWS, DOORS, VENTILATORS AND PARTITIONS CONFORMING TO IS:1948, 1961 WITH HOLLOW BOTTOM SECTION & STANDARD SINGLE / TWO / THREE / FOUR TRACK FRAME SECTION ALL ROUND (TOP, BOTTOM AND SIDES) WITH SHUTTER FRAME MADE UP OF STANDARD HANDLE SECTION STANDARD INTERLOCKING SECTION AND STANDARD TOP AND BOTTOM SECTION WITH INFILL PANEL OF PLAIN /FROSTED / TINTED GLASS/ NOVAPAN SHEET / ACRYLIC SHEET / HARDNER LAMINATED SHEET AS LISTED BELOW WITH NYLON GUIDES, GLIDERS GLASS FIXING PVC WEATHER STRIPS, NEOPRENE GASKET, PVC WEEP HOLES ETC COMPLETE WITH APPROVED TYPE OF LOCKING ARRANGEMENT, HANDLES AND OTHER FIXTURES INCLUDING FIXING, FILLING THE GAPS WITH SILICON SEALANT, CLEANING POLISHING THE ALUMINIUM SECTION WITH PETROL AND / OR OTHER AGENTS AS SPECIFIED BY THE MANUFACTURERS ETC. COMPLETE AS DIRECTED BY ENGINEER IN CHARGE. GLAZING WORK/NOVAPAN/HARDNER/ACRYLIC SHEET SHALL BE PAID SEPARATELY UNDER RESPECTIVE ITEM. |
| 6 | PROVIDING AND FIXING GEAR OPERATED ROLLING SHUTTER, HAVING FOLLOWING SPECIFICATIONS,1) LATHS/SHUTTER STRIPS OF0.9MM THICK (MIN.) GI SHEET OFSAIL/ JSW / TATA OR EQUIVALENT.2) GUIDE CHANNELS OF MS 100 MM X 3MM THICK (MIN.)3) HEAVY DUTY HIGH TENSION SPRING MADE FROM HIGH TENSILE SPRING STEEL WIRE AS PER SHUTTER SIZE.4)HEAVY DUTY GEAR SET ASSEMBLY (MACHINE CUT GEAR OF HIGH GRADE CAST IRON OR MILD STEEL) WITH PULLING HANDLE.5) SHAFT: MS PIPE 48MM OD HEAVY DUTY.6) BOTTOM PLATE/LOCK PLATE: MIN. 3 MM THICK REINFORCED WITH MS ANGLE OF MIN. SIZE 35X35X5MM FITTED WITH SLIDING BOLTS AND HANDLES ON BOTH SIDES.7) BRACKETS: MS PLATE 400X400MM, MIN. 6MM THK8) SHAFT PINJARA : MS FLAT 30 MM X 6 MM 9) TOP COVER 0.9 MM GI10) PAINT: ONE COAT RED OXIDE PRIMER AND ONE COAT OF SYNTHETIC ENAMEL FOR MS. MATERIALNOTE: INCASE OF LESSER THICKNESS OF SECTIONS, REDUCTION IN RATE ONPRO-RATA BASIS OF WEIGHT SHALL BE MADE. RATE IS INCLUSIVE OF SCAFFOLDING REQUIRED FOR THE WORK. |
| 7 | PROVIDINGAND APPLYINGTWOCOATSOF EXTERIORACRAYLICEMULSION PAINTCONFIRMINGTO CORRESPONDING I.S. OF APPROVED MANUFACTURE AND OF APPROVED COLOUR TO THE PLASTERED SURFACES INCLUDINGCLEANING,PREPARINGTHEPLASTERSURFACE,APPLYINGPRIMERCOAT,SCAFFOLDINGIF NECESSARY , AND WATERING THE SURFACE FOR TWO DAYS ETC COMPLETE. |
| 8 | PROVIDING, DETAILING, AND FABRICATING AS PER SPECIFICATIONS, TRANSPORTING TO SITE AND ERECTING MS OPEN ABLE / SLIDING /ORNAMENTAL ENTRANCE GATES INCLUDING TRACK AND WHEEL, LOCKING ARRANGEMENT,FIXING BOLTS, NUTS, WASHERS, CLEATS, STIFFENERS, GUSSETS DECORATIVE BALUSTERS, ARROW HEADS ETC. AND ALL NECESSARY OPERATIONS LIKE STRAIGHTENING, BENDING, CUTTING, DRILLING, GRINDING, MACHINING IF SPECIFIED, WELDING ETC. COMPLETE WEIGHING 25 TO 30 KG /SQ.M, INCLUDING CLEANING, GRINDING AND REMOVING THE WELDING BURR AND PREPARING SURFACE AND APPLYING ONE COAT OF RED OXIDE ZINC CHROMATE PRIMER AND ONE COAT OF SYNTHETIC ENAMEL PAINT AFTER FABRICATION AND SECOND COAT OF SYNTHETIC ENAMEL PAINT AFTER ERECTION, WITH APPROVED COLOUR, SHADE AND BRAND ETC. INCLUDING TOUCHING UP WITH PRIMER ETC. COMPLETE AS DIRECTED BY ENGINEER IN CHARGE. |
| 9 | PROVIDING AND APPLYING TWO COAT OF WATERPROOF CEMENT PAINT OF APPROVED MANUFACTURE AND COLOUR TO THE PLASTERED SURFACE,INCLUDING SCAFFOLDING PREPARING THE SURFACE ,WATERING FOR TWO DAYS ETC COMPLETE |
| 10 | PROVIDING, AND FIXING ALUMINIUM COMPOSITE PANEL 3MM THICK WITH SHEET OF APPROVED QUALITY AND MAKE (VIVA OR EURO BOND OR EQUIVALENT MAKE) IN PLAIN CLEAR OR ANY APPROVED COLOUR WITH HEAVY SECTIONAL ALUMINUM FRAME WORK AND CLADDING COMPOSITE WITH SILICON INCLUDING PROVIDING SCAFFOLDING AND INSTALATION IN PROPER LINE AND LEVEL COMPLETE AS DIRECTED BY ENGINEER IN CHARGE. |
| 11 | PROVIDING & FIXING 3 MM THICK PLAIN/BAJARA SHEET GLASS TO NEW/EXISTING WINDOW/VENTILATOR PANELS. RATE INCLUDES REMOVAL OF BROKEN GLASS (IF ANY) CAREFULLY, REMOVAL OF OLD PUTTY/BIDDING AND PROVIDING NEW PUTTY/BIDDING ETC. COMPLETE. |
| 12 | PROVIDING AND FIXING ONLY MISC. MATERIALS NOT COVERED IN THE SCHEDULE OF RATES MENTIONED ABOVE INCLUDING, FIXING AS DIRECTED BY EIC, STORAGE, TRANSPORTING, LOADING, UNLOADING AT SITE ETC. COMPLETE AS DIRECTED EIC ASPER REQUITREMENT OF JOB .(PAYMENT SHALL BE MADE ON BASIS OF ACTUAL COST OF MATERIAL PER GST-CASH MEMO/ RECEIPT-GST). 10% EXTRA PAYABLE TO THE CONTRACTOR TO COVER PROFIT AND OVERHEAD. |