| Sl. No. | Item Description |
| 1 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 2 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 3 | 50000008\"Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. \"Ground Floor |
| 4 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 5 | 50000018\"4\"\" thick dry brick rammed khoa well watered and fully consolidated complete,including cost of all materials as per direction of Engineer-in-charge. \"Ground Floor |
| 6 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 7 | First Floor |
| 8 | Second Floor |
| 9 | Third Floor |
| 10 | Forth Floor |
| 11 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 12 | First Floor |
| 13 | Second Floor |
| 14 | Third Floor |
| 15 | Forth Floor |
| 16 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 17 | First Floor |
| 18 | Second Floor |
| 19 | Third Floor |
| 20 | Forth Floor |
| 21 | 50000023\"Priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc.complete. \"(FOR OUTSIDE)Ground Floor |
| 22 | First Floor |
| 23 | Second Floor |
| 24 | Third Floor |
| 25 | Forth Floor |
| 26 | 50000025\"Wall painting two coats with plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. \"Ground Floor |
| 27 | First Floor |
| 28 | Second Floor |
| 29 | Third Floor |
| 30 | Forth Floor |
| 31 | 50000035\"providing & fixing ceramic tiles of approved size in dado & skirting over cement plaster 1:3, 12mm thick jointed with with neat white cement slurry including cost of all material labour T & P etc.complete. \"First Floor |
| 32 | Second Floor |
| 33 | Third Floor |
| 34 | 50000036\" Floor Tile flooring over cement plaster 1:1 25mm. thick bed with cost of all materials, labours T & P etc.complete. \"First Floor |
| 35 | Second Floor |
| 36 | Third Floor |
| 37 | 50000044Providing anti-termite treatment including labour and materials etc complete.(As per specification confirming to IS Code 6313-3(2001)part-3 ).Ground Floor |
| 38 | First Floor |
| 39 | Second Floor |
| 40 | Third Floor |
| 41 | Forth Floor |
| 42 | 50000057Drip course mould plaster 1:4 (1:cement :4sand) including necessary scaffolding curing etc. complete at all depth and height.Ground Floor |
| 43 | First Floor |
| 44 | Second Floor |
| 45 | Third Floor |
| 46 | Forth Floor |
| 47 | 50000063\" One coat of priming with approved primer over new wood work. \"Ground Floor |
| 48 | First Floor |
| 49 | Second Floor |
| 50 | Third Floor |
| 51 | Forth Floor |
| 52 | 50000071\"2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard grinite chips on new work including cost of labour,material,T&P etc all complete. \"Third Floor |
| 53 | Forth Floor |
| 54 | 50000495Fly Ash brick masonry in cement mortar 1:4 (1 cement:4sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75 kg per sq. cm with dimensional tolerance +/-2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure.Ground Floor |
| 55 | Third Floor |
| 56 | 50000742\"Painting two coats of Anti-fugal weather coat water proofing paint including scaffolding and cleaning the surface before application. \"Ground Floor |
| 57 | First Floor |
| 58 | Second Floor |
| 59 | Third Floor |
| 60 | Forth Floor |
| 61 | 50000879\"Supplying and fitting, fixing of chequer tiles over cement mortar 1:1, 25mm. thick with cost of all materials, labour, T & P etc.complete. \"Ground Floor |
| 62 | 50000884\"Enamel painting two coats including cost of all materials cleaning,brushes,putty etc. \"Ground Floor |
| 63 | First Floor |
| 64 | Second Floor |
| 65 | Third Floor |
| 66 | Forth Floor |
| 67 | 50000964Providing and Fixing of Granite Flooring in floors, Treads and Landings over 25mm thick bed of cement mortar 1:1 jointed with neat cement slurry mixed with pigment to match the shades of the Granite including cleaning etc.Ground Floor |
| 68 | First Floor |
| 69 | Second Floor |
| 70 | Third Floor |
| 71 | 50001152Providing & fixing aluminium work (min.thickness of powder coating 50 micron) for structural glazing including required scaffolding for fixing the aluminium sections for extruded builtup standard tubural & other sections of approved make confirming to IS:733 and IS:1285 fixing with rawl plugs & screws or with expansion hold fasteners including necessary fillings up gaps at junctions at top,bottom & sides with cement mortar,aluminium sections shall be smooth,rust free ,straight,mitred & jointed mechanically,the glazing will be 5mm thick,coloured,reflective glass of approved colours & make (SAINT GOBAINI) fixed in aluminium sections upto required height & joints filled clear weather silicon sealant etc complete in all respect as per the direction of EIC/Architect in charge.First Floor |
| 72 | Second Floor |
| 73 | Third Floor |
| 74 | Forth Floor |
| 75 | 50001303Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & PlinthGround Floor |
| 76 | 50001305Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure.Ground Floor |
| 77 | First Floor |
| 78 | Second Floor |
| 79 | Third Floor |
| 80 | Forth Floor |
| 81 | 50001311Fly Ash brick masonary in cement mortar 1:4:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure.First Floor |
| 82 | Second Floor |
| 83 | Forth Floor |
| 84 | 50001694Supplying, fitting & fixing of Vetrifed Tile in floors of size 600mm x 600mm (colour / printed series)of approved make conforming to IS : 13755 laid on 20 mm thick cement mortar and filling joints with white cement of approved quality including cost of all materials, labour T &P etc required for the works all complete as per direction of Engineer -in- charge. (For new work only)Ground Floor |
| 85 | First Floor |
| 86 | Second Floor |
| 87 | Third Floor |
| 88 | Forth Floor |
| 89 | 50001814Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame. shutters and all fitting and fixtures.Ground Floor |
| 90 | First Floor |
| 91 | Second Floor |
| 92 | Third Floor |
| 93 | 50007923Supplying,fitting & fixing of Stainless steel aquare pipe using 50X50X2.5MM size square pipe with vertical post and one horizontal rail and grade of size 30X30X2.5MM size square pipe as per approved design and specification, buffing,polishing etc with cost,conveyance of all materials, labour,T&P etc required for the complete in all respect.[JINDAL/NIPPON STEEL]First Floor |
| 94 | Second Floor |
| 95 | Third Floor |
| 96 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 97 | First Floor |
| 98 | Second Floor |
| 99 | Third Floor |
| 100 | Forth Floor |
| 101 | 50010542Providing, Fitting and Fixing of three track (122mmx 54mm) height below 1.5 Mtr.UPVC glazed sliding window Premium quality with frames and sashes shall be from white UPVC profile. All section of frame and sashes shall be reinforced with galvanized steel in single continuous length, holes about 8mm dia to be provided @ 300mm C/C outer side of lower sashes, window shall be such that glazing or deglazing on site possible without the need to remove the outer frame from the structure of the building. Glazing must be used 5mm thick reflective toughened glass with weather seal. Window frame will be fixed to the wall with 100mm long and minimum 8mm dia. fasteners and after fixing frame the gap in between the frame and wall should be filled with silicon sealant for inner frame sealing complete with all fixtures in all respect. UPVC Window make:-DUROPLAST / SIMTA ASTRIX / NCL VEKA, All GLASS work:- Saint-Gobain/AIS (ASAHI).First Floor |
| 102 | Second Floor |
| 103 | Third Floor |
| 104 | 50010554Providing, supplying and fixing of UPVC Glazed Fixed Louvered Ventilator of size 600 mm X600 mm made out of multi chambered UPVC of DUROPLAST / SIMTA ASTRIX / NCL VEKA having isolated drainage, holes about 8 mm dia. to be provided @ 300 mm C/C outer side of lower sashes and reinforced with Galvanized Iron profiles throughout the window with Fan(185mm)of USHA / CROMPTON/Havells/Anchor. The outer frame having an overall size of 39 mm x 39 mm x 2.2 mm thickness with reinforcement of 1.2 mm . Ventilator shall be provided with 4 mm Pin Head glass, standard hardware. Wall thickness of frame and Mullion shall be 2.4 mm, including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site complete for finished item of work with transportation and wastage.First Floor |
| 105 | Second Floor |
| 106 | Third Floor |
| 107 | 50010620Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY)Ground Floor |
| 108 | First Floor |
| 109 | Second Floor |
| 110 | Third Floor |
| 111 | Forth Floor |
| 112 | 50010668Providing and Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units to be of approved colour using high quality pigments complete in all respect as per specification. [NSWI] WPC Frame make:-Century/GreenFirst Floor |
| 113 | Second Floor |
| 114 | Third Floor |
| 115 | 50010704Providing and Fixing of Single leaf solid WPC door shutter of 30 mm thick compacted with wood grain finished with 2 Nos SS Handles (150 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 4 Nos. SS Butt Hinges (125mm x 8.5mm x 5.5mm ) with all necessary fittings Complete with approved colour . [NSWI]Make:- WPC Door(Century/Green), Hard ware fittings (Godrej).First Floor |
| 116 | Second Floor |
| 117 | Third Floor |
| 118 | 50010716Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing.Ground Floor |
| 119 | First Floor |
| 120 | Second Floor |
| 121 | Third Floor |
| 122 | Forth Floor |
| 123 | 50010827Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia. of 2mm thick circular pipe with Balustrade of size 38mm x 38mm x 2mm @ 900mm C/C, stainless steel square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification and the entrance newel post will be 100mm dia. of 750mm height with top bulb, buffing, polishing etc. with cost, conveyance, labour, T and P etc. required to complete in all respect. [NSWI] Stainless steel Brand:- JINDAL/NIPPON STEEL.Ground Floor |
| 124 | First Floor |
| 125 | Second Floor |
| 126 | Third Floor |
| 127 | Forth Floor |
| 128 | 50010839Supplying, fitting and fixing of 110mm dia PVC rain water down pipe (min. 6kg/sqcm) (IS-4985) with necessary fittings and all complete. PVC Pipe Brand:-SUPREME/ORIPLAST/FINOLEX.Ground Floor |
| 129 | First Floor |
| 130 | Second Floor |
| 131 | Third Floor |
| 132 | Forth Floor |
| 133 | 50010927Providing and fixing of Storage Cabinet / Cup board made of 18mm WPC Board,ISI Certification Cabinet will have horizontal panel should be finger joints. The door shutter will be fixed using 9 degree auto hinge. The surface of the Cabinet will be finished with gloss finish laminates including 1st quality teak wood moulding and leaping.Cabinet will have provision for door, with lock and key with ISI certification hardware. WPC board:- Greenply Endure/Century , Laminate make:- Century lam/Greenlam ,Marino Hardware fittings- Godrej.First Floor |
| 134 | Second Floor |
| 135 | Third Floor |
| 136 | 50011579Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC ROOF SLAB)Ground Floor |
| 137 | First Floor |
| 138 | Second Floor |
| 139 | Third Floor |
| 140 | Forth Floor |
| 141 | 50011592Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC COLUMNS)Ground Floor |
| 142 | First Floor |
| 143 | Second Floor |
| 144 | Third Floor |
| 145 | Forth Floor |
| 146 | 50011604Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC SILL BAND)First Floor |
| 147 | Second Floor |
| 148 | Third Floor |
| 149 | 50011616Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR COLUMN FOOTING)Ground Floor |
| 150 | 50011628Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR LINTEL BEAM).Ground Floor |
| 151 | First Floor |
| 152 | Second Floor |
| 153 | Third Floor |
| 154 | 50011640Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR RCC CHHAJA & SHELVES).Ground Floor |
| 155 | First Floor |
| 156 | Second Floor |
| 157 | Third Floor |
| 158 | Forth Floor |
| 159 | 50011652\"Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC STAIRCASE).Ground Floor |
| 160 | First Floor |
| 161 | Second Floor |
| 162 | Third Floor |
| 163 | 50011664Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR TIE BEAM).Ground Floor |
| 164 | 50011676Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR RCC FLOOR BEAMS).Ground Floor |
| 165 | First Floor |
| 166 | Second Floor |
| 167 | Third Floor |
| 168 | Forth Floor |
| 169 | 50011688Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC FINS).Ground Floor |
| 170 | First Floor |
| 171 | Second Floor |
| 172 | Third Floor |
| 173 | 50015685Supplying. fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete.First Floor |
| 174 | Second Floor |
| 175 | Third Floor |
| 176 | 50015997Priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc.complete.(FOR INSIDE)Ground Floor |
| 177 | First Floor |
| 178 | Second Floor |
| 179 | Third Floor |
| 180 | Forth Floor |
| 181 | 10000556Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200cfm/300psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories,tools and plant and consumables etc for lowering of 200mm dia PVC pipes for housing fitted with socket and with or without well screen as per tenecessity for soft,medium,hard and boulder formation (PVC casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and with drawing after completion of the tube well).(Icluding both LABOUR FOR DRILLING 200MM DIA UPTO 30 MTR. & LABOUR FOR DRILLING 150MM DIA FROM 30 MTR TO 150 MTR including all.) CONSIDER FOR 150 MTR DEPTH.Ground Floor |
| 182 | 10000564Lowering 200mm dia. PVC pipes with or without slotted pipes as per the necessity from ground level with fitting and fixing the same in a perfectly vertical position. This includes cutting, threading pipes/slotted pipes with providing and fixing of required jointing materials, tools and plant etc. complete and keeping the top of the casing pipe threaded including plugging tube wells so as to prevent entry of foreign materials from above. (FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG).Ground Floor |
| 183 | 10000570Cleaning and developing 200mm dia. tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour .(FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG).Ground Floor |
| 184 | 10000583Supplying and fixing of control panel board with all accessories. (UPTO 3HP SINGLE PHASE) Make: KSBGround Floor |
| 185 | 10000588Supplying and fixing of HDPE Pipes 32/40 mm (High Density Polyethylene pipes having inner dia. 32mm and outer dia. 40mm) 6Kg/Sq. cm With IS specification.(32MM NOMINAL BORE SIZE). Make Finolex/Oriplast/Supreme.Ground Floor |
| 186 | 10000594Supplying and fixing of PVC coated steel rope including cost of material, labour etc. complete. Make-Mahdev/AerolexGround Floor |
| 187 | 10000596Supplying and fixing of Finolex/L&T/Cable 4 Sq. mm (3core copper wire flat cable with PVC insulation).Ground Floor |
| 188 | 10000600Supplying and fixing of accessories like Nipple, Bore cover, MS clamp, Nut Bolt, Stainless steel nipple, Short piece, GI bend, Socket etc. complete.Ground Floor |
| 189 | 10000602Installation charges pump set with all accessories including transportation etc.Ground Floor |
| 190 | 10001184Supplying of 200mm inner dia. PVC casing pipe for deep bore well CD (deep well casing) type basing on IS-12818-2010, wall thick ness 13mm to 14.8mm with One end of the pipe is male-threaded whereas the other end is a female-threaded socket. Threads are either V-type or trapezoid-type, and protection caps are provided on the threads to protect the threads in transit. With pressure ratings ranging from 7.5 to 20 bar (PN). Make: ORIPLAST/SUPREME/FINOLEXGround Floor |
| 191 | 10001190Supplying Submersible Pump Set with the cost of Motor of following model including cost of transportation charges.1.5HP, Single phase,32D,19 Stage (head 50-129m). Make: KSB(2C/21).Ground Floor |
| 192 | 40000946Recessed wiring to Angle Holder Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havells/V guard/KEI) Make-switch /Angle holder-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 193 | 40000949Recessed wiring to Tube Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 194 | 40000952Recessed wiring to Calling Bell Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular bell push ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-bell push switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 195 | 40000958Recessed wiring to Television Point (Modular)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/TV socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK).Ground Floor |
| 196 | 40000970Recessed wiring to Ceiling Fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 197 | 40000973Recessed wiring to Exhaust fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 198 | 40000976Recessed wiring to Security Light Point ( MODULAR)(1X36WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/HPL/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 199 | 40000979Recessed wiring to Security Light Point ( MODULAR) (4X24WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 15 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/HPL/KEI) Make-switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 200 | 40000982Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 201 | 40000988Point wiring for 15/16 amp socket outlet ( MODULAR) with 4.0sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 15/16 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 202 | 40001000Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 203 | 40001003Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.3)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 204 | 40001006Recessed wiring to submain in 2 x 6 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.4)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 205 | 40001126providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18)Ground Floor |
| 206 | 40001129Supplying and fixing of 6\"X4\" 16/18 swg,2 \" deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-National / Royalam)Ground Floor |
| 207 | 40001132Supplying and fixing of 8\"X6\" 16/18 swg,2 \" deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-(National / Royalam)Ground Floor |
| 208 | 40001135Supplying and fixing of 8\"X10\" 16/18 swg,2 \" deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5)(Make-(National / Royalam)Ground Floor |
| 209 | 40001141Supplying and fixing of two modular GI Box 18 swg with Modular base & cover for 2 module (Sl. No- 1301,1421)(Make-switch/Socke t-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 210 | 40001145Supplying and fixing of 4 modular GI Box 18 swg with Modular base & cover for 4 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 211 | 40001151Supplying and fixing of 8 modular GI Box 18 swg with Modular base & cover for 8 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 212 | 40001154Supplying and fixing of 12 modular GI Box 18 swg with Modular base & cover for 12 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 213 | 40001157Supply and Fixing of 32 amp. DPMCB – 01 no wth 32 amp. 240 volt cutout – 02 nos with copper bus bar & indicator etc.including all accessories and connections . [Make-(a) MCB/MCCB- Legrand/L &T/ABB/SCHNEIDER(b)- Voltmeter, Ammeter-AE/CAPPA (c) ALL OTHER ACCESSORIES ISI MARK]Ground Floor |
| 214 | 40001160Supply and fixing of 63AMP DPMCB-1NO ,63 AMP .240V CUTOUT-2NOS METER SPACE WITH LOCKING ARRANGEMENT,METER CUT OUT,COPPER BUS BAR & INDICATOR including all accessories and connections. [Make-(a) MCB/MCCB- Legrand/L&T/ABB/SCHNIDER(b)- Voltmeter, Ammeter-AE/CAPPA (c) ALL OTHER ACCESSORIES ISI MARK]Ground Floor |
| 215 | 40001172Supply of U-type fan hook(Make-TATA)Ground Floor |
| 216 | 40001190Supplying and fixing of Call Bell/buzzer ISI marked suitable for DC/AC single phase 230 volts complete as required (CSR sl no-1.30)Ground Floor |
| 217 | 40001193Blanking Plate(Make-Legrand /Wipro-NorthWest /Anchor-Panasonic/ havells)Ground Floor |
| 218 | 40001234supply of Stepped type modular fan regulator.(Make-Regulator-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 219 | 40001237Supply and fixing of 4 way , single Door MCB Box with 1 No 32 Amp. DP MCB & 2 Nos of 20 Amp. SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.( Sl. No- 2.3.,2.7, )Make-MCB-(Legrand/L &T/ABB/SCHNIDER/ANCHOR-PANASONIC)Ground Floor |
| 220 | 40001307Supply and fixing of 12 way , Double Door MCB Box with 1 No 32 Amp. DP MCB & 10 Nos of 20 Amp. SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.Make-MCB-(Legrand/L&T/ABB/SCHNIDER/ANCHOR-PANASONIC)Ground Floor |
| 221 | 40001316Supply and fixing of 1 phase tested energy meter as per norms of Electrical distribution company. (Make- Secure/ Palmohan/ L&T / Visiontake/Genus)Ground Floor |
| 222 | 40001322Deposit of service connection charges with Distribution companyGround Floor |
| 223 | 40001325Supply and fixing of 3/4\" MS Bend Pipe including all acessories and connections to be fixed at each quarters for inserting service wire to energy meter.Ground Floor |
| 224 | 40001833Supply and fixing of 6 sqmm service wire along with G.I wire for support of service wire including all acessories and connections.( Make-Joshi/Multicab)Ground Floor |
| 225 | 40001876Supply and fixing of 16 Amp top(for inverter installation) with all accessories and conncetion(Make-Legrand/wipro/Anchor-Panasonic)Ground Floor |
| 226 | 40001879Recessed wiring in 1X1.5sqmm (For inverter)/DG wiring )FR PVC insulated single core multistrand copper conducter of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick as per direction of Engineer in charge(Make of wire Finolex/Anchor/Havells/V guard)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 227 | 40002179Recessed wiring to Surface Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection .( Make of wire Finolex / L &T / Anchor / Havells/ V guard)Make-switch /-Legrand /Wipro /Anchor /havells /Panasonic)Ground Floor |
| 228 | 40008126Supply and fixing of 250 mm sweep air ventilating fan with Louvers (PVC BODY) fan with connecting wire and all accessories including fixing and connections . [MAKE- USHA MODEL-CRISP AIR VX/CROMPTON MODEL-VENTILUS/HAVELLS/ANCHOR)Ground Floor |
| 229 | 40008158Supply and fixing of 1200 mm BLDC (ISI mark 5 star rated)(28wt with aluminium blade)ceiling fan (without remote) with connecting wire and all accessories including hanging and connections .- [MAKE- USHA MODEL-TECHNIX/ CROMPTON MODEL-ENERGIA GROOVE /V-GUARD /HAVELLS MODEL-EFFICIENCIA NEO/ANCHOR-PANASONIC MODEL-PENTA TURBO)Ground Floor |
| 230 | 40008291Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing)Ground Floor |
| 231 | 40010756Supply and fixing of 9 WT. LED Bulb installred at angle holder/ batten holder.(Make- PANASONIC (MODEL NO-PBUM01097)/HAVELLS(MODEL NO-ADORE).Ground Floor |
| 232 | 40010758Supply and fixing of 4 FT 20 W LED Tube light fitting with lamp including fixing and connections (Make- PANASONIC(MODEL NO-PBTM012 07)/HAVELLS(MODEL NO-PHOTON ULTRA).Ground Floor |
| 233 | 40011132Supply & fixing of 25 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories (Make- PANASONIC(MODEL-PSTM27258)/HAVELLS(MODEL-ENDURA SUNDOWN30W)Ground Floor |
| 234 | 40011134Supply & fixing of 45 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories (Make-PANASONIC(MODEL-PSTM27458)/HAVELLS(MODEL-ENDURA SUNDOWN45W)Ground Floor |
| 235 | 40011488Supply and fixing of surface mounted led 15 w square/round light with powder coated finished in white housing 1with lamp , choke, connecting wire, and all accessories and connections .(Make- PANASONIC(MODEL-PDLM36128)/HAVELLS(MODEL-ENDURA NEO)Ground Floor |
| 236 | 10000002Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 20mm nominal outer dia pipesGround Floor |
| 237 | 10000004Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 25mm nominal outer dia pipesGround Floor |
| 238 | 10000006Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 40mm nominal outer dia pipesGround Floor |
| 239 | 10000174Laying in trenches unplasticised PVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by heat application method including testing as per specification complete. (Earth work in trenches to be measured and paid for separately). (160mm dia rigid UPVC pipe Class- 3 (0.60 mpa)).Ground Floor |
| 240 | 10000176Laying in trenches unplasticised PVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by heat application method including testing as per specification complete. (Earth work in trenches to be measured and paid for separately). (110mm dia rigid UPVC pipe Class- 3 (0.60 mpa)).Ground Floor |
| 241 | 10000294Laying in trenches OD PVC pipes and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by non-heat application method including testing as per specification complete. 110mm dia OD P.V.C SWR double socket pipes (ISI TYPE-A),Analysis is done as per AR-2013,SL NO-2.3.2 .Ground Floor |
| 242 | 10000296Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .SINGLE JUNCTION WITH DOOR 110 mm P.V.C SWR TYPE. according to AR-2013 SL NO-3.3.3(V)Ground Floor |
| 243 | 10000298Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .110MM DIA PLAIN BEND P.V.C SWR TYPEGround Floor |
| 244 | 10000300Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .110mm dia bend with door P.V.C SWR TYPEGround Floor |
| 245 | 10000304Fixing 110mm size ‘P’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification.110 MM DIA P.V.C SWR P-TRAPGround Floor |
| 246 | 10000308Fixing floor traps of the following nominal diameter of outlet of self cleaning design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per specification.110mm dia GULLY Trap P.V.C SWR TYPEGround Floor |
| 247 | 10000310Providing and fixing on wall face PVC SWR moulded fittings / accessories for PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .110 mm dia off set as per p.v.c swr type.Ground Floor |
| 248 | 10000312Providing and fixing on wall face PVC SWR moulded fittings / accessories for PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion.110 mm dia cowel P.V.C SWR TYPE.Ground Floor |
| 249 | 10000318Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. ( With Seat and cover)Ground Floor |
| 250 | 10000322Fixing wash basins with hole for pillar taps conforming to with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification.Porcelain Counter Top Basin Oval shape(550X430) with Pillar cock for basin (C.P Pillar cock with Swinging spout),PVC inlet connection pipe ,Chromium Plated brass waste ,PVC waste pipe 32mm Dia,Chromium Plated brass trap including all as per the direction of the E.I.C.Ground Floor |
| 251 | 10000332Providing and fixing Stainless Steel kitchen sink with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required.24\"X18\"X10\" STEEL sink single bowl (parry ware) as per the direction of the E.I.C.Ground Floor |
| 252 | 10000336Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.As per the direction of the E.I.C .(10 litre capacity - colour)Ground Floor |
| 253 | 10000346Fixing of C.P Screw-down TWO WAY Bib Cocks (Taps) polished bright conforming to with CP flange and CP extension piece of the following nominal sizes as per specification complete As per the direction of the E.I.C . (Delux Head& high quality).(15mm diameter C.P Two way bib cock)Ground Floor |
| 254 | 10001062Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 50 mm outer dia CPVC pipes.Ground Floor |
| 255 | 10001088Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc. all complete as per specification with 1:4 brick work in cement mortar (1:4) and 12mm thick cement plaster. For 250mm thick wall.Ground Floor |
| 256 | 10001094Cutting holes in R.C.C floor and roofs up to 19cm thick for passing G.I/PVC pipes and fittings etc. and repairing the hole after insertion of pipes etc. with cement concrete (1:2:4) including finishing complete so as to make it leak proof. Details cost of 1 hole of average size 15cm X 15cm X 25cm.Ground Floor |
| 257 | 10001096Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete, with cement concrete (1:3:6) and 12mm cement plaster (1:3) along with Cement punning.Ground Floor |
| 258 | 10001098\"Fixing floor traps of the following nominal diameter of outlet of self cleaning design with serewed down or hinged grating with or without vent arm complete includingcost of cutting and making good the walls and floors all complete as per specification. 110mm INLET & OUTLET FLOOR TRAP.make: ORIPLAST/SUPREME/FINOLEX \"110mm Dia Inlet & Outlet floor trap PVC SWR type.Ground Floor |
| 259 | 10001124Providing and fixing of 25mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 25 mm dia. CPVC Full Way Valve / Ball Valve.Ground Floor |
| 260 | 10001126Providing and fixing of 40mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 40 mm dia. CPVC Full Way Valve / Ball Valve.Ground Floor |
| 261 | 10001160Providing and fixing Rotational moulded polyethylene cylindrical vertical water storage tank 3layer wall conforming to IS : 12701--1996 including cutting holes through the tank and fixing, fittings CPVC tubes and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting up to a height of 5 metres above ground level and placing the tank to the required position etc. all complete as per specification. Make: SINTEX/SUPREME/ORIPLAST. Triple Layer Cylindrical Vertical water storage tanks.Ground Floor |
| 262 | 10001162Extra over (item No 3.1.8 as per A.R 2013) for hoisting Rotational moulded polyethylene cylindrical vertical water storage tanks of the following size for every additional height of 5 metres or part there of installation on roof as per the requirement and site condition.Ground Floor |
| 263 | 10001464Supplying,fitting & fixing of 15mm dia C.P.long body bib cock with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 264 | 10001466Supplying,fitting & fixing of 15mm dia C.P.angular stop cock with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 265 | 10001468Supplying,fitting & fixing of 15mm dia C.P concealed stop cock with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 266 | 10001470Supplying,fitting & fixing of CP Shower (Over Head) with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 267 | 10001472Supplying,fitting & fixing of CP Arm for Over head Shower with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 268 | 10001474Supplying,fitting & fixing of CP Health Foucet with 1.0 1 RM PVC Tube with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 269 | 10001476Supplying,fitting & fixing of C.P.soap holder/disc. with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 270 | 10001478Supplying,fitting & fixing of C.P. glass scif with glass with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 271 | 10001480Supplying,fitting & fixing of CP. towel rail.(600x20)mm with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 272 | 10001482Supplying,fitting & fixing of CP. towel ring. with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 273 | 10001484Supplying,fitting & fixing of Bevelled Edge Mirror with all fixtures complete as per the requirement at site (rates as per sor)Ground Floor |
| 274 | MIS-CVL-BRICKMASON |
| 275 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 276 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 277 | 50000008\"Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. \"Ground Floor |
| 278 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 279 | 50000019\"25mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. \"Ground Floor |
| 280 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 281 | 50001303Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & PlinthGround Floor |
| 282 | 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor |
| 283 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 284 | MIS-CVL-INSPECTION |
| 285 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 286 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 287 | 50000008\"Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. \"Ground Floor |
| 288 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 289 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 290 | 50001303Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & PlinthGround Floor |
| 291 | 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor |
| 292 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 293 | MIS-CVL-PAVERROAD |
| 294 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 295 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 296 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 297 | 50015702Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC.Ground Floor |
| 298 | MIS-CVL-SEPTICTANK |
| 299 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 300 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 301 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 302 | 50000018\"4\"\" thick dry brick rammed khoa well watered and fully consolidated complete,including cost of all materials as per direction of Engineer-in-charge. \"Ground Floor |
| 303 | 50000019\"25mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. \"Ground Floor |
| 304 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 305 | 50001303Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & PlinthGround Floor |
| 306 | 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor |
| 307 | 50001839Fly Ash brick masonary work in cement mortar 1:4 (1 cement : 4 sand) using fly ash bricks of 23cm X 11cm X 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/-2% including watering,curing and cost,conveyance,royality of all m aterials and cost of labour etc complete.As per the direction of the E.I.C.Ground Floor |
| 308 | 50010360Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB)Ground Floor |
| 309 | 50010420Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC CHHAJA and SHELVES)Ground Floor |
| 310 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 311 | MIS-INE-LIGHTINGPR |
| 312 | 40002086Air-Terminal Supply, Installation, Testing & Commissioning of Early Streamer Emission (ESE-30))type Lightning Air Terminal. Supporting Mast The mounting pole used to support the lightning air terminal shall be minimum length of 05 Mtr. , non corrosive and made up of medium class GI / SS pipe of 1.5″ diameter having base plate at bottom for securely fixing the mast on roof top. The mounting pole and supports shall be securely fixed with the brackets and PVC insulated metallic guy wires to withstand the maximum wind velocity of that area. Protection Radius :- 48 Mtr Make :- ABB / STROMKING All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.Ground Floor |
| 313 | 40002089Lightning Strike Counter Supply, Installation, Testing & Commissioning of non-electronic & non-resettable (Not require any external power supply) type lightning strike counter to count the lightning stroke having display with IP-67 enclosure including all accessories and connection..(6/7 digit) Make :- ABB / STROMKING All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Engineer-in-Charge.Ground Floor |
| 314 | 40002095Supply, Installation, Testing & Commissioning of maintenance free chemical earthing having enhancing chemical compound with 3 Mtr. Long copper bonded steel rod and suitable termination clamp including all accessories. Make :- ABB / STAR-X / UNIVERSAL All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.Ground Floor |
| 315 | 40002720Supply and laying of 70sqmm single core FR PVC insulated unseathed copper conductor for voltage grade 1100 volt as per IS-694 in sur face/underground as required(sl no-5.5.2)(Make-KEI/FINOLEX/HAVELLS)Ground Floor |
| 316 | a) APPROVED MAKE /BRAND FOR CEMENT : ULTRATECH, NUVOCO, ACC, JSW (PSC),RAMCO(PSC),DALMIA(PSC),SAGAR(PSC) |
| 317 | APPROVED MAKE / BRANDS ARE TO BE UTILISED STRICTLY DURING EXECUTION OF ABOVE RELATED ITEMS OF WORK |
| 318 | CESS Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail