| 1 | Labour only for Non Comprehensive Routine maintenance checkup of Fire alarm system\"s error and alarms, necessary inspection of the Fire alarm system and take necessary corrected actions, resolve any issues regarding the system and take corrective actions for the problems , check connectivity and communication at all terminations, check all power sources and outlets used in the system complete for all panels all Fire alarm system at site \"A\" by authorised service engineer of OEM and furnish the report to Engineer-in-charge. |
| 2 | (a) All as per above item No 1 but for ABBAKKABuilding at Little Binaga. |
| 3 | (b) All as per above item No 1 but for CHINNAMMABuilding at Little Binaga. |
| 4 | (c) All as per above item No 1 but for M .C.P.OBuilding at Kadmba Vanam. |
| 5 | (d) All as per above item No 1 but for MAIN M.O BUILDING and M.O WAREHOUSE and M.O STORE and M.OCENTEENBuilding at Core Area. |
| 6 | (e) All as per above item No 1 but for VB YardBuilding at Core Area |
| 7 | (f) All as per above item No 1 but for CT Pool at Core Area |
| 8 | (g) All as per above item No 1 but for HQ Kadamba Building at Core Area |
| 9 | (h) All as per above item No 1 but for HangarBuilding at Core Area |
| 10 | (j) All as per above item No 1 but for Patanjali HospitalBuilding at Core Area |
| 11 | (k) All as per above item No 1 but for HQ Main Building at Core Area |
| 12 | (l) All as per above item No 1 but for NSRY Fire stationBuilding at NSRY. |
| 13 | (m) All as per above item No 1 but for CDT at Core Area. |
| 14 | (n) All as per above item No 1 but for WM Tower -22 PUSHPA at Kadamba Vanam |
| 15 | (o) All as per above item No 1 but for WM Tower- 23 NALANI at Kadamba Vanam |
| 16 | (p) All as per above item No 1 but for SBS Bldg at Little Binaga |
| 17 | (q) All as per above item No 1 but for DHANAM and MANIK New Tower Officer md Accn at Kamat Bay |
| 18 | (r) All as per above item No 1 but for New Tower- 31at Amdali |
| 19 | (s) All as per above item No 1 but for New Tower- 32 at Amdali |
| 20 | Supply and fix in repair Fire alarm control panel with network cardcomplying with BSEN 54 Singleloop panel of capacity from 99 detectors and 99 modules up to 200 detector and modules(per each loop) including battery, power supply complete installation with networking of panels all as specified and directed by Engr-in-charge. |
| 21 | Supply and fix in repair Fire alarm control panel with network cardcomplying with BSEN 54 double loop panel of capacity from 99 detectors and 99 modules up to 200 detector and modules(per each loop) including battery, power supply complete installation with networking of panels all as specified and directed by Engr-in-charge. |
| 22 | Supply and fix in repair Fire alarm control panel with network cardcomplying with EST 3XSingleloop panel of capacity from 99 detectors and 99 modules up to 200 detector and modules(per each loop) including battery, power supply complete installation with networking of panels all as specified and directed by Engr-in-charge. |
| 23 | Material and labour in repair conventional type 16 zone fire alarm panel up to 20 detectors per zone with 6 hours battery back up, detector circuit monitored for open circuit, short circuit and 16 zone panel.including 2 No 12V,7 AH dry rechargeable batteryetccomplete all as specified and directed. |
| 24 | Material and labour in repair conventional type 10 zone fire alarm panel up to 20 detectors per zone with 6 hours battery back up, detector circuit monitored for open circuit, short circuit and 10 zone panelincluding 2 No 12V,7 AH dry rechargeable batteryetccomplete all as specified and directed. :- |
| 25 | Supply and fix inreplacement Addressabledual loopcard complete all as specified and directed. |
| 26 | Supply and fix in replacement Zone cards10 zone card and16zone card and 8 zone and X zone 4etccomplete all as specified and directed. |
| 27 | Supply and installation in repairs of Addressable Smoke detector along with required accessories complete all as specified and directed. |
| 28 | Supply and installationin repairs of Addressable Heat detector along with required accessories complete all as specified and directed. |
| 29 | Supply and installation in repairs of Addressable Multi Sensor detector along with required accessories complete all as specified and directed. |
| 30 | Supply and installation in repairs of Addressable Isolator Module along with required accessories complete all as specified and directed. |
| 31 | Supply and installationin repairs of Addressable Control Module along with required accessories complete all as specified and directed. |
| 32 | Supply and installation in repairs of Addressable Sounder cum strobe along with required accessories complete all as specified and directed. |
| 33 | Supply and installationin repairs of Addressable Manual Call Point along with required accessories complete all as specified and directed. |
| 34 | Supply and Laying in repairs of 2 Core 1.5 Sq mm Copper Flexible Cable for control wiring with and including copper lugs, connectors etc complete all as specified and directed. |
| 35 | Supply and Fix in repairs lead acid typebattery of 12 Volts 7 AH capacity complete all as specified and directed . |
| 36 | Supply and installation in repair of network card of Fire Alarm control panel complete all as specified and directed |
| 37 | Supply and installation in repair of Power supply of Fire Alarm control panel complete all as specified and directed |
| 38 | Supply and installation in repair of Display of Fire Alarm control panel complete all as specified and directed |
| 39 | Supply and installation in repair of MCP Glass only complete all as specified and directed |
| 40 | Supply and installation in repair of loop card of Fire Alarm control panel complete all as specified and directed |
| 41 | Supply and installation in repair of mother board of Fire Alarm control panel complete all as specified and directed |
| 42 | Supply and fix in repairs hose box made of 18 gauge MS Sheet 800mm X 600mm X 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and inside yard complete all as specified and directed. |
| 43 | Supply and fix in repair drum with hose reel of 20 mm dia and 30 mtr long with nozzle conforming to IS 5132 complete all as specified and directed. |
| 44 | Supply and fix in repair Branch pipe gun metal 63 mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short complete all as specified and directed. |
| 45 | Supply and fix in repair and replacement Yard hydrant Post / Stand Post 80mm Dia GI / MS both flanged type 1.5m Height complete all as specified and directed. |
| 46 | Supply, installation, testing and commissioning of PN 1.6 rated 80 mm NB CI swing check type reflux (non return) valve, conforming to IS:5312 (part 1)-2004 with flange drilling standard end connection conforming to IS: 1538-1993 and necessary accessories all complete as specified and directed. |
| 47 | Supply and fix gun metal one way fire hydrant landing valve of 63 mm dia with instantaneous coupling complete all as specified and directed. |
| 48 | Material and labour RRL hose type A 15 m length and 63 mm dia, non-percolating type conforming to IS 636 complete all as specified and directed |
| 49 | Supply and laying MS ERW Pipe 80 mm painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer including all fittings complete all as specified and directed. |
| 50 | Supply and laying MS ERW Pipe 65 mm painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer including all fittings complete all as specified and directed. |
| 51 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting outin soft/loose soil all as specified and directed. |
| 52 | Returning filling in soil including spreading leveling, watering and well ramming in layers not exceeding 25cmall as specified anddirected. |
| 53 | Removing excavated material/soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. |
| 54 | Supply and fix in repair and replacement of single headed Hydrant Valve complete all as specified and directed. |
| 55 | Supply and fix in repair and replacement of Butterfly Valve of size 100 mm dia complete all as specified and directed. |
| 56 | Supply and fix in repair and replacement of Butterfly Valve of size 80 mm dia complete all as specified and directed. |