| 1 | Excavation in trenches n exc 1.5min depth for foundation etc or for shabts, well, cesspits, monhells, pier holes etc n exc 10 Sqm en plan and nexc 1.5m in depth and getting out complete all as specified and directed |
| 2 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 3 | M&L hardcore broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 4 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 5 | M&L 100 mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate as in sub base finishing the surface even and rough to receive floor finishes complete all as specified and directed. |
| 6 | M&L RCC M-25 using(20mm graded stone aggregates) for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 7 | M&L RCC M-25 using (20mm graded stone aggregates) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 8 | M&L RCC M-25 using(20mm graded stone aggregates) Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 9 | M&L RCC nominal mix type B1 1:2:4 using (20mm graded stone aggregate for chajja complete all as specified and directed |
| 10 | M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 11 | Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 12 | Use and waste of form work for sides of concrete foundation footing, bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams and similar work, vertical or to batter roughed finished surface of concrete complete all as specified and directed. |
| 13 | Use and waste ofFormwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc.finished fair and even complete all as specified and directed. |
| 14 | Use & waste for form work to sides of pillars, posts, struts columns, square, rectangular or polygonal etc finished fair and even complete all as specified and directed. |
| 15 | Use & waste for Formwork to chullah hoods, chajjas, troughs and similar items including edges finished fair and even complete all as specified and directed. |
| 16 | M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 17 | M&L Pre- painted galvalume aluminum zinc coating GIbased Plainsteel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 18 | M&L 75mm thick cement concrete Type C2 1:3:6 using(40 mm graded stone aggregate) in plinth protection and even and finishing cement concrete surface even and smoothwithout using extra cement complete all as specified and directed. |
| 19 | S & F Powder coated aluminium sliding glazedwindows with three track shutter sliding (two shutters glazed and one shutterwire mesh) shall be following specification complete all as specified and as directed.(i)Windows frame of cross section 101mm x 44mm x 1.5mm thick.(ii)Three way track for sliding shutters of cross section91.8mm x 31.75mm x1.1mm thick.(iii)Sliding shutter frame of cross section40 x 18 x 1mm thick.(iv)4 mm thick tintedglass superior quality.(v) IDPE Rubber guasket for fixing of glass.(vi)Locking cleats per shutter -01 Nos.(vii)Sliding rollers per shutter - 02 Nos.including satety steel grill(viii) Aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56mm for shutters 01 Nos. |
| 20 | Providing and fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum ) False ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture contents less than 2% humidity resistance of 99% NRCO.50 to .75 as pe IS8225:1987, Noncombustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on interlocking metal T Grid of hot dipped galvanized iron section of 0.33 mm thick ( galvanised @ 120 gms per sqm including both sides ) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross -T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600mm, suspened from ceiling using galvaized mild steel items ( galvanizing @ 80 grams per sqm) i..e 50mm long, 8mm outer diameter M-6 dash fastener 6mm dia fully threaded hanger rod upto 1000mm length and L-swhape level adjuster of size 85x25 x 2mm galvanised iron permieter wall angle of size 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm ceneter to centre and 50mm long dry wall wood screws. The kwork shall be carried out as per specifications, drawing. |
| 21 | S&F Pressed steel frames 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed |
| 22 | Providing Factory Made 28-30 mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Flush Door Shutter of required size comprising ofvirgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbmmanufactured by \"RAJSHRI\" an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 50 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutterand fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company, complete all as specified and directed. |
| 23 | Providing30 mm thickWire mesh Solid WPC Door shutter consisting ofDensity 500 Kg /CbmManufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose.(confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hingessize 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19*6mm size steel screws etc. Complete as per direction, manufacturer\"s specification & drawings. |
| 24 | Material & labour for Rendering 10 mm thick CM 1:6 using water proofing liquid compound as permanufacturer\"s instructionson brick or concrete surfaces finished even & smooth without using extra cement including necessay scaffolding etc.complete all asspecified and directed. |
| 25 | M&L for preparation of newly plastered surface of internal wall by application of 1 mm thick wall care putty to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed |
| 26 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe-410- W(Gde- E-250) quality- B complete all as specified and directed. |
| 27 | S & F mild steel plate (plain or chequered) channels,square cut or notched (ordinary and counter sunk ) forming holes, with riveted,bolted or weleded attachement confirming to Fe- 410-W (Gde E-250) quality A complete all as specified and directed. |
| 28 | S & F mild steel screwbolts 16 to 20mm dia ( Machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nuts exc 15 cm and n exc 22.5 cm long, complete all as specified and directed |
| 29 | M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified |
| 30 | S&F 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm screed bed 1:6 cement mortar complete all as specified and directed. |
| 31 | M&L Damp proof course In cement concrete (1:2:4)type B-0 40mm thick to horizontal or vertical surfaces including necessary formwork complete all as specified. |
| 32 | Supply only Liquid water proofing compound complete all as specified. |
| 33 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops rounded or chamfered on edges complete all as specified and directed. |
| 34 | M&L hand made sliding bolts; clamps; hold fasts; hooks for hanging fans and similar small articles complete all as specified and directed. |
| 35 | Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets, complete all as specified and directed. |
| 36 | M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to mathc the shade of the slab including rubbing and polishing complete incl 20mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 37 | M&L for machine cut Kota stone slab 20-25 mm thick as in vertical surfaces such as risers of steps, skirting, dado etc over 10mm cement screed bed laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing complete all as specified and directed. |
| 38 | M&L for 100mm thick cement concrete type B-2 (1:2:4) using 40mm graded stone aggregateincluding spike rolling complete all as specified. |
| 39 | M & L for Rendering 15 mm thick in two layers i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as permanufacturer\"s instructions on other than fair faces brick or concrete surfaces and finishing surfaceseven & fair complete all asspecified and directed.Note :- Water proofing liquid compound shall be measured and paid separately. |
| 40 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces and preparation of new plaster surface complete all as specified and directed. |
| 41 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in hard/dense soil complete all as specified and directed. |
| 42 | Removing surplus excavated soil to a distance exc 250m and not exceeding 500m & depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 43 | M&L forfly ash, brick work withsub class\"B\" bricks , usingold sizebricks, straight or curvedon plan exc 6 m meanradius built in cement mortar1:4 complete all as specified and directed. |
| 44 | Material & labour for Rendering 5 mm thick CM 1:3 on ceiling of brick or concrete surfaces finished even & smooth without using extra cement complete all asspecified and directed. |
| 45 | M&L for three coats of white washing of newly plastered surface of ceiling including preparation complete all asspecified and directed. |
| 46 | M&L for 40mm thick cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate as in floor /plinth protectioncomplete all as specified. |
| 47 | Surface excavation n.exc.30cm deep and averaging 7.5cm deep & getting out in any type of soil. |
| 48 | M&L for 20 mm thick screed bed or bedding layer with CM 1:4 as in base for laying chequered tiles paver blocks etc complete all as specified. |
| 49 | Material and labour Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern and conforming to IS-15658 : 2006 as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 50 | Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required completeall as specified and as directed. |
| 51 | Excavation post holes (or similar holes) each n exc. 0.5 Cum, getting out Soft/ loose soil, Returning, filling in and ramming earth or broken rubble mixed with earth around, in layersn.exc. 25 cm, watering and removing surplus soil to a distance not exc 50m and making good surface Complete all as specified and directed |
| 52 | M&L for Plain Cement Concrete Type C2 1:3:6 (using 40 mm gradedstone aggregate) in foundations, filling and mass concrete. |
| 53 | S&F of mild steel angles,bars, flats etc as in supports for posts and struts in fencing including cutting tops to shape as directed,drilling holes,notching for wire,etc, flat iron fillets (For securing wire mesh etc.,) including all necessary drilling,bolting or riveting,etc., and similar workconforming to fe 410-0or Fe 165-O. |
| 54 | S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type standard rails, straining bolts incl securing or tying at crossings with and provn of galvanised MS wire, staples or steel pins, etc., all as specified (each line/ row to be measured) |
| 55 | Supply of chain link fencing including line wire any mesh and any type of standard rails staining bolt etc including provision of binding wire etc complete all as specified and directed. . |
| 56 | Fixing only chain link fencing including line wires, and mesh size type of stadrads, rail straining bols etc size of mess 100x100mm 4mm dia wire complete all as specified and direceted. |
| 57 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts gradeISI-694 marked drawn through in and including heavy duty, PVC surface conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken/gang boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches,including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly includingcutting, chasses and makinggooddisturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 58 | (a) One light point controlled by one, one way switch 5 Amps |
| 59 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 60 | (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 61 | (d)One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 62 | Description all as pe ser item No 57.00 above butusing 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 63 | S & F for Modular Switch piano flushtype, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 64 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 65 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 66 | S & F forModular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 67 | S & Ffor modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 68 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISImarked for batten fitting complete all as specified |
| 69 | M & L forSub main wiring with approved colour coding as per IS withsingle core PVC insulated FRLS cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:-Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit |
| 70 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 71 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired andnecessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed |
| 72 | S & F for sheet metal enclosure MCBDBTPN4 way ,200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 73 | S & F for sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 74 | S & FforMCB tripple pole and neutral rated capacity 16-32 Amps, 415 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 75 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 76 | S & Ffor MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 77 | S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan teriminal includingwritting the MES Number with synthetic enamel paintcomplete all as specified and as directed. |
| 78 | S & F for energy efficient exhaust fan of 450 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing brick wall for fan baseincluding writting the MES Number with synthetic enamel paintcompelte all as specifiedand directed. |
| 79 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. |