| 1 | Dismantling of single layer of manglore/ Similar pattern tiles in roofing complete all as directed. |
| 2 | Dismantling of battens of tiles of any size and description spaced exc 15 cm, including tiling fillets complete all as directed. |
| 3 | Dismantling of unframed wk timber scantlings 40 sq. cm and over in section, in any position complete all as directed. |
| 4 | M&L for wrought second class hard-wood in scantlingsin repairs, to replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions to store complete all as specified and directed |
| 5 | M&L for clean sawn second classhardwood tile battens at 30cm centres, exe 5 and n.exe 15 sqcm sectional area complete all as specified and directed |
| 6 | Ditto all as per itemNo. 05 above but except battens |
| 7 | M&L for preparing tile battens of any size and spacing andtreated all over (measured overall on one side only spaces not deducted) with two coats of cresoting oil etccomplete all as specified and directed |
| 8 | M&L for providing roof tiles manglore pattern interlocking at side joints, laid dry (at any height of bldg), complete all as specified and directed |
| 9 | Ditto all as per item No. 08 above but except tiles |
| 10 | M&L for ridge or hip tiles to suit mangalore pattern of roofing tiles, bedded and jointed in CM (1:6) complete all as specified and directed |
| 11 | Ditto all as item No. 10 above but except tiles |
| 12 | S&F in repair 20mm thick second class hard-wood in eaves boards etccomplete all as specified and directed |
| 13 | M&L for preparation of new wooden surfaces and paintingtwo coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed |
| 14 | M&L for cutting of vegetation plant from roof, terrace, chajjas etc digging out the roots and making good the surface in PCC (1:2:4) type B1 (using 20mm graded stone aggregate) with surfaces finished to match including scaffolding (at any height ) etc complete, all as specified and directed |
| 15 | M&L for preparing old plastered/conrete surface ofroof/wall with wire brush with water thoroughly to remove all dust/dirt and loose particles and applying 3 coats of Dr fixit New coat/Asian paint damp proofor equivalent on roof/wall surfaces including crack seal sealent if required at crack portion of roof/wall all application as per manufacturer instruction and including warranty certificate provided by applicator/company complete all as specified and directed. |
| 16 | Takingdown of existing tarfeltand cement plaster of anydescription and thicknesson rooftopincluding flashing andjunctionof parapetandcleaning existingroof topsurfaceby brooming, wirebrushingincl removing the debrishout completeall asspecified and directed |
| 17 | Demolition Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 18 | M&L for cement concrete type B0 (1:2:4) 12.5mm size graded stone aggregate ) in roof padding complete all as specified and directed |
| 19 | M&Lfor10mmthickrenderingon concrete surface on roof in cementplaster1:4finishedevenand fairwithoutusingextracementby using Dr. fixit or equivalent@3%of wt of cement contentcomplete all as specified and directedNote: Liquid Water proofing Compound measured and paid seprately |
| 20 | Supply only Liquid water proofing compoundcomplete all as specified and directed |
| 21 | M&L for water proofing treatment on wall,roof,chajja\"s,gabble walls, edges (atany respective height of bldg ) as followingas manufacturer\"s instructions complete all as specified all as specified and directed(a) preparing plastered surfaces and applyingapproved bituminous primer @ 0.3 Kg/sqm uniformly to receive APP membrane(b) Applyingand stick non-woven polyster matt modified APP Membrane 3mm thick as reinforcement weighing not less than 3.5 Kg/sqm, bonding material85/25bitumen1.2 Kg/Sqmbeforeandafter layingmembranelaidbytorchapplication and sideoverlapof 150 mm andoverlapof 150 mm longtitudinally, (c)At thejunctionof roof andparapet walla grooveof 75mm wide and 65mm deep and shaping horizontal of groov with 1:3 with bituminious masticjoints/overlap shallbe sealedwithhotbitumen85/25(d)Applying one coat of aluminium paint on top of the membrane (at any height ) as per manufacturer instructions |
| 22 | M&L for providingcementconcrete PCC (1:2:4) type B1 (20mm graded stone aggregate)as in coping to parapet wall/kerbs in roof with projection of 50mm from the outer surface with a groove of 12 mm x 12mm as drip course in bottom sideincluding necessary form work etc completeall as specified and as directed |
| 23 | Dismantling ofPlain or corrugated steel sheeting, any gauge, thickness, including Nainital orsimilarpattern roof coverings complete all as specified and directed |
| 24 | S&F galvanised corrugated mild steel sheeting 0.63mm thick with two corrugations side lap, fixed with \"L\" type or \"J\" type of cranked hook in lieu ofscrews and washers in roofs, walls etc with grade of zinc coating 275 complete all as specified and directed |
| 25 | S&F galvanised plain mild steel sheeting 0.63mm thick in Ridge, hips, valley gutter, drip and straight flashing (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 26 | S&F pre painted galvalume aluminium zinc coating GI based corrugatedsteel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering /cladding to wall fixed with L hooks or J types or cranked bolts completeat any heights all as specified and as directed |
| 27 | Takingupor down 15 mm steeltubing and connections including cleaning for refixing complete all as specified and directed |
| 28 | Taking up or down 20 mm steeltubingandconnections includingcleaningfor refixing complete all as specified and directed |
| 29 | Refixing 15 mm old steel tubing and connections in new or old position (Walls, ceiling, floors, etc) complete all as specified and completed |
| 30 | Refixing 20mm old steel tubing and connections in new or old position (Walls, ceiling, floors) etc complete all as specified and completed |
| 31 | S&F 15 mm bore mild steel water tubingmedium grade galvanized with all fittings and fixture fixed to walls ceiling or laid in floors complete all as specified and as directed |
| 32 | Ditto all as per above item No 31above but for 20 mm bore |
| 33 | S&F in repair Ball valves 15mm dia high pressure of PTMT with epoxy coated Aluminiumrod& highdensity plastic ball screwed for iron pipe and fixed.(Minimum weight 15mm-142gms/ 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms)including taking down old one complete all as specified and directed. |
| 34 | Ditto all as per Item No. 33 above but 20mm dia |
| 35 | Disconnecting existing water tanks exc 250lts n.exc 500 ltrs capacity ,setting aside (or lowering if required ) for repair,cleaning etc and hoisting if required reconnecting and refixing in position (cleaning,repairing etc measured separately) complete all as directed. |
| 36 | Disconnecting existing water tanks exc 500lts n.exc 1000 ltrs capacity ,setting aside (or lowering if required ) for repair,cleaning etc and hoisting if required reconnecting and refixing in position (cleaning,repairing etc measured separately) complete all as directed. |
| 37 | Cleaning and removing all scale and dirt, etc, from water storage tanks 500 Ltr capacity existing tanks and from mouths of circulating pipes, etc complete all as specified and directed |
| 38 | Cleaning and removing all scale and dirt, etc, from water storage tanks 1000Ltr capacity existing tanks and from mouths of circulating pipes, etc complete all as specified and directed |
| 39 | Dismantling of old cast iron/ PVC /AC 100 mm bore pipes jointed in cement motar or fixed to wall or floor complete all as specified and directed |
| 40 | Dismantling of old cast iron/ PVC /AC 75 mm bore pipes jointed in cement motar or fixed to wall or floor complete all as specified and directed |
| 41 | S&F75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or floor including stack clamps complete all as specified and directed |
| 42 | S&F110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or floor including stack clamps complete all as specified and directed |
| 43 | S&F for 75mm dia PVC (SWR) bends any radiuscompleteall as specified and directed |
| 44 | S&F for 75mm bore dia PVC (SWR) bends with access door complete all as specified and directed |
| 45 | S&F for 75mm dia PVC (SWR) junction single(single T) complete all as specified and directed |
| 46 | S&F for 75mm dia PVC (SWR) branch piece single(single Y)equal or unequal completeall as specified and directed |
| 47 | S&F for 75mm dia PVC (SWR) vent cowl complete all as specified and directed |
| 48 | S&F for 110mm dia PVC (SWR) bends any radiuscompleteall as specified and directed |
| 49 | S&F for 110mm bore dia PVC (SWR) bends with access door complete all as directed. |
| 50 | S&F for 110mm dia PVC (SWR) junction single(single T) completeall as specified and directed |
| 51 | S&F for 110mm dia PVC (SWR) branch piece single(single Y)equal or unequal completeall as specified and directed |
| 52 | S&F for 110mm dia PVC (SWR) vent cowl completeall as specified and directed |