| 1 | Removing the existing roof treatment of any description completely and remove all the debrisold water tanks from site and rubbish off the premises complete all asspecified and directed. |
| 2 | M & L for roughening surfaces of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc.and brushing neat cement slurry with 3 Kg of cement per square metre complete all asspecified and directed. |
| 3 | M & L for providing cement concretetype B0 1:2:4 using (12.5mm graded stone aggregate) as in padding and benching & filletting with IWPC (IWPC measured and paid seperately) complete all as specified and directed. |
| 4 | M&L screed bed or bedding layer 10 mm thick CM 1:4 for laying floor finishes finished even and smooth without using extra cement with WPC (WPC measured separately) as in roof slabs complete all as specified and directed. |
| 5 | Supply only integral water proofing compound. |
| 6 | Material and labour for water proofing treatment with APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified with non woven polyester matt black finished over compatiable primer at 0.3 litre per sqm,torching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per manufactures instructions and finally finished with at coat of bitumastic aluminium paint over the membrane. The over lap joint shall be provided of 100mm in longitudinal direction and 150mm in tranverse direction respectively.All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage complete all as specified and as directed.Note : The work shall be carried out by authorized applicators of manufacturers. |
| 7 | Demolition of cement concrete un reinforaced of any description and in any position not other wise specifically provided for complete all as specified and as directed. |
| 8 | M&L for filling polymer modified non shrinking slurry for sunken floors for toilets by drilling holes 60mm by 20mm dia at 1 mtr interval and applying slurry all as per technical specification complete all as specified and as directed. |
| 9 | M&L for rendering 15mm thick in CM 1:3 on concrete surfaces iincluding finishes even and smooth withoutusing extra cement complete all as specified and as directed. |
| 10 | M&L for filling polymer modified non shrinking slurry for sunken floors for toilets by drilling holes at 1M interval to a depth of 60 mmx20mm dia and applying 2 mm thick brush bond over the concretesurfaceby mixing acrylic emulsion NITO BOND BB 4 Ltr with brush bond powder 23 kgs and water 4 ltrslurry all as per technical specification and as required complete work upto work including testing etc. complete all as specified and as directed. |
| 11 | M&L for PCC (1:4:8)using (40mm graded stone aggregate) type D2 asin foundations, filling mass concrete complete all as specified and as directed. |
| 12 | M&L for 40mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate)mixed with WPC at 2% by weight of cement, complete all as specified and as directed. Note:WPC shall be measured separately. |
| 13 | Dismantling of AC sheets / Galvalume sheet / GI Sheet of corrugated or semicorrugatedsheets in roof coverings etc. Complete all as specified and as directed. |
| 14 | S&F Pre-painted galvalume aluminium zinc coating GI based profilesteel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, as in roof covering / cladding to wall and fixed with self tapping screwscomplete all as specified and as directed |
| 15 | S&F Pre-painted galvalume aluminium zinc coating GI based plainsteel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa,as in roof covering / cladding to wall and fixed with self tapping screwscomplete all as specified and as directed |
| 16 | Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and as directed |
| 17 | S & F for MS framed structure roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all as specified and directed. |
| 18 | M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed |
| 19 | Disconnecting existing tanks of capacity exc 250 ltr & n exc 500 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately), etc complete all as specified and directed. |
| 20 | Disconnecting existing tanks of capacity exc 500 ltr & n exc 1000 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately), etc complete all as specified and directed. |
| 21 | S&F 500 Ltr capacity rotaional moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position including dismantling existing tank complete all as specified and directed. |
| 22 | S&F 1000 Ltr capacity rotaional moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position all as specified including dismantling existing tank complete all as specified and directed |
| 23 | S&F 2000 Ltr capacity rotaional moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position all as specified including dismantling existing tank complete all as specified and directed. |
| 24 | S&F in repair Ball valves 25 mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight25mm-455gms) complete all as specified and as directed |
| 25 | S&F in repair20mm bore dia Gun metal Gate valvewith iron wheel head screwed both endsfor iron pipe or for union, complete all as specified and directed. |
| 26 | S&F in repair25mm bore dia Gun metal Gate valvewith iron wheel head screwed both endsfor iron pipe or for union, complete all as specified and directed. |
| 27 | S&F in repair40mm bore dia Gun metal Gate valvewith iron wheel head screwed both endsfor iron pipe or for union, complete all as specified and directed. |
| 28 | S&F GI tube 40mm dia medium graded with all fitings and fixed to wall, celing or laying in trenches including taking up and down complete all as specified and directed. |
| 29 | S&F GI tube 25mm dia medium graded with all fitings fixed to wall, celing or laying in trenches including taking up and down existing GI tubing complete all as specified and directed |
| 30 | S&F GI tube 20mm dia medium graded with all fitings and fixed to wall, celing or laying in trenches including taking up and down existing GI tubing complete all as specified and directed. |
| 31 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. Complete all as specified and as directed |
| 32 | M & L for brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 33 | M & L half Brick wall with sub-class \"B\" bricks old size straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed |
| 34 | Taking down cement plaster any descriptionon brick or stone walls, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 35 | M&L for10mm thick in CM 1:6 rendering on brick or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed . |
| 36 | M & L for rendering 15mm thick in cement mortor 1:4 on Brick wall surfaces, finished even and smooth without using extra cement with @ at 3% IWPC (IWPC measured separately) complete all as specified and directed. |
| 37 | M&L for Rendering 5mm thick in CM 1:3 as in ceilings concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed |
| 38 | M&L forpreparation of new plastered surfaces of walls three coats of white washcomplete all as specified and directed |
| 39 | M&L forpreparation of new plastered surfaces of walls andapplying two coats of oil bond distemper over a coat of chalk whiting primer paint on plastered surface all as specified and directed |
| 40 | M&L forpreparation of new plastered surfaces of walls three coats of Colour washcomplete all as specified and directed |
| 41 | M & L preparation of new surfaces of walls plastered or unplastered etc and applying two coat of cement based paint paint on wall complete all surfaces as specified and as directed |
| 42 | M&L for Praparation of Newly plastered surfaces and applying Three coats of White wash on Ceiling complete all as specified and directed |
| 43 | M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection etc complete all as specified and directed. |
| 44 | S & FPVC( SWR ) pipes 110mm dia single socketed , in any lenthwith rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches incl taking down complete all as specified and directed. |
| 45 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 46 | S&F PVC (SWR) branch piece single ( Single Y) equal or un equal with access door of bore 110 mmcomplete all as specified and directed. |
| 47 | S&F grating doom 100mm dia of PTMT (minimum weight 25gms )complete all as specified and directed. |
| 48 | M&L for morum filling/redbajri fillingunder floors or in foundations including watering &consoldation laid in layers n.exc 15 cm thick spread levelled and well rammedcomplete all as specified and directed. |
| 49 | M&L for 75mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in plinth protection etc finishing the surface even and smooth without using extra cement. |
| 50 | M&L for 100 mm thick cement concrete type D-2, 1:4:8 using (40mm graded aggregate) as in Sub-base to floor finishes. complete all as specified and directed. |
| 51 | Material and Labour Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern and conforming to IS-15658:2006. as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra and complete all as specified and directed. |