| Sl. No. | Item Description |
| 1 | B/R Portion: -Demolition of cement concrete (unreinforced) in ground floors and pavings any thickness (below or above ground level) and removing unserviceable material exceeding 100 mtr complete all as specified and as directed. |
| 2 | Demolition of brick masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 3 | Demolition of cement concrete (reinforced cement concrete) in ground floors and pavings not exceeding 15 cm thickness (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. |
| 4 | Taking down cement plaster of any description on brick or stone walls or from concrete surface including racking out joints, hacking for key, scrubbing with water etc complete all as specified and as directed. |
| 5 | Taking down chowkhats or frames with shutter without taking off shutter from the frame not exceeding 1.5 Sqm each including cutting holes for taking out holdfast or dismantling brick (holes cut and any other damage to jambs, wall for taking out holdfast shall be finished identical to existing finish without any extra cost to Govt) complete all as specified and as directed. |
| 6 | Taking down chowkhats or frames with shutter without taking off shutter from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each including cutting holes for taking out holdfast or dismantling brick (holes cut and any other damage to jambs, wall for taking out holdfast shall be finished identical to existing finish without any extra cost to Govt) complete all as specified and as directed. |
| 7 | Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each complete all as specified and as directed. |
| 8 | Taking down, easing and adjusting shutters of any description, exceeding 1.00 Sqm and not exceeding 2.00 Sqn each and refixing in the same opening complete all as specified and as directed. |
| 9 | Dismantling floors, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 10 | Dismantling of PVC, cast iron 100mm or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed. |
| 11 | Dismantling of PVC, cast iron 75mm or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed. |
| 12 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 13 | Removing existing treatment from roof surfaces such as tiling, tarfelt, fungus, moss, dust etc., cleaning the surface of all foreign material by wire brushing and dusting and racking out RCC slab complete all as specified and removing the debris outside defence land all as directed. |
| 14 | Brick work of old size sub class ‘B’ bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 15 | Cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) as infoundation, filling and mass concrete complete all as specified and as directed. |
| 16 | Cement concrete (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) as in backfill of pressed steel door frames complete all as specified and as directed by the Engineer-in-Charge. |
| 17 | PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in blocks for hold fasts, benching, coping apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.Note: - Form work required for these items included in the unit rate of this item. |
| 18 | 25 mm thick PCC (1:2:4) type B-1 (using 20 mm crushed stone aggregate) as in floor finished rough complete all as specified and as directed. |
| 19 | 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection laid to an outward slope of not less than (1:12), cast in panels not exceeding 2.0 sqm areas with 6 mm wide joints. The joint shall be filled with mastic filling and 10 mm wide joints between the walls and plinth protection shall be filled with mastic filling and finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 20 | Cement concrete type E-2 (1:5:10) (using 40 mm graded crushed stone aggregate) as in sunken portion complete all as specified to receive floor toping as specified after carrying out the required tests of water proofing and all as directed. |
| 21 | Providing cement concrete type B-0 (1:2:4) (using 12.5 mm graded crushed stone aggregate) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 22 | Providing pre-cast cement concrete (1:2:4) typeB-1 (using 20 mm graded crushed stone aggregate) as in cover slab of manholes, septic tank, soak well etc set in cement mortar (1:4) with plain fair faces including chamfered weathering, throating etc including necessary use and waste of formwork complete all as specified and as directed. |
| 23 | Hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a true surface complete all as specified and as directed. |
| 24 | Framed work as in grills, gratings etc with end of bars shouldered or riveted or forged into spikes, framed guard bars confirming to Fe-290, Gde-E-165 complete all as specified and as directed.Note: - Grills (8 mm square bars and 6mm Steel flat bars) shall be fixed in wall with steel screws not less than 100 mm long as inner face of aluminium windows. |
| 25 | Mild steel TMT bars 6 to 8 mm dia as in reinforcement, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 26 | Pressed steel frames for door (factory made) out of 1.25 mm thick black mild steel sheet, with one or more rebates including necessary fixing lugs, butt hinges, lock strike plate, etc. complete size of frame 125 x 60mm including bottom of each chowkhat to be welded with 2 No\"s 25 x 25 x 3 mm thick flat iron projecting 10 cm on either side including one shop coat of red oxide primer complete all as specified and as directed.Note: - PCC (1:3:6) type C-0 as in back fill will be paid separately. |
| 27 | Solid PVC door frame and for cupboards of size 50mm x 47mm made out of 5mm PVC sheet and edges will be painted to match with printed sheet, reinforced with mild steel square tube supplying and fixing in opening as per specification complete all as specified and as directed. |
| 28 | 30 mm thick PVC factory made panel door shutter (style) consisting of frame made out of mild steel tubes for top and bottom rail, mild steel frame shall be covered with heat moulded wood grain printed PVC channel and 5 mm thick x 15 mm wide PVC sheet beading used inside style and rails and decorative PVC beading of 10 x 10 mm used instead of exposed portion of PVC sheet beading as in toilet/ kitchen cabinet shutters complete all as specified and as directed. |
| 29 | 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, both faces are covered with decorative face veener with lipping/ frame to match complete all as specified and as directed by Engineer-in-Charge. |
| 30 | 35 mm thick second class hard wood half glazed and skelton shutters open rebated and prepared to receive glass/ wire gauge etc. without sash bar but with lock rail edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass/ wire mesh etc sizes of member as per clause 8.20 (a) of SSR Part - I for door shutter complete all as specified and as directed. |
| 31 | Aluminium anodized powder coated (minimum thickness 50 micron) sliding window (Two track) consisting of two shutter of glazed including all necessary fittings and flyproof mesh shall be fixed on external face of window frame with aluminium beads, the following items shall be included in quoted rate of this item: -(a) Aluminium powder coated frame of section 63.5 x 38.10 mm x 1.02 mm thick with or without rebate.(b) Aluminium powder coated window shutters of section 40 x 18 mm x 1.25 mm thick (Both shutter of glass) including self locking catch and roller etc.(c) 4.0 mm thick coloured or tinted glass glazing as in aluminium window/ ventilator with aluminium hollow beading/ glazing clip (included with shutters) size 19mm x 17mm made out of 0.70mm thick hollow section weighing not less than 0.97 Kgs/RM including rubber gasket.(d) Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with statinless steel wire staples and aluminium beads. |
| 32 | Powder coated aluminium door shutter with chowkhats made out of hollow aluminium sections as mentioned below, each shutter having 2 No\"s ‘D’ type aluminium handles of 200 mm long, 2 No\"s aluminium tower bolts of 200 mm long and 1 No mortice lock of 6 lever with key in duplicate, regulated by double action hydraulic floor door spring, shutter partly glazed with 5.5 mm thick sheet glass and partly panelled with 12 mm thick pre-laminated particle board fixed with glazing clips, rubber beadings and aluminium beading complete all as specified and as directed: -Chowkat size : 101.60 x 44.45 x 2.40 mm (1.608 Kg/ RM appx.)Shutter Top rail : 114.30 x 2.15 mm thick (1.836 Kg/ RM appx.)Bottom rail : 150.00 x 2.20 mm thick (2.376 Kg/ RM appx.)Middle rail : 83.50 x 1.70 mm thick (1.243 Kg/ RM appx.)Vertical rail : 85.00 x 1.80 mm thick (1.302 Kg/RM appx.). |
| 33 | Partition wall (Panels of 1.44 Sqm (approx) made out of aluminium powder coated anodized standard hollow sections 63.50 X 38.10 X 1.95mm thick snap fit beadings, standard rubber gasket, 5.5mm thick sheet glass and 4mm thick PVDF aluminium composite panels consisting of a polyethylene core sand witched between two 0.4 mm thick aluminium skins and coated with polyester resin of PVDF coating of any colour or shade complete all as specified and as directed.Note for item: - The scope of work include for taking down existing damaged aluminium door/ window/ grill/ panels and the unit rate quoted shall be deemed to be included for the same. |
| 34 | 4mm thick of size 605 x 605 mm, white pre-premiered, self embossed, reinforced designer board for false ceiling conforming to IS-14862 and ISO-8336 :1993 and GI section frame work (Powder coated) for white, pre-premiered, self embossed, reinforced designer board consisting of perimeter wall angle 19mm X 19mm X 0.45mm, cross \"Tee\" 28.6mm (web) X 24mm flange. 33mm thick powdered coated main tee 38 (Web) X 24mm flange 0.33mm thick. Wall angle screwed fixed to brick wall/ partition wall/ concrete/ RCC with the help of nylon sleeves and screws @ 610 mm centre to centre, then suspending GI main \"Tee\" in both directions by means of hangers with alignment @ 1220mm centre to centre to soffits. To from grid of 610 X 610mm cross Tee shall be provided @ 610mm centre to centre in both directions. Suitable provisions shall be made for fixing the recessed/ surface mounting light fittings if any complete all as specified and as directed by Engineer-in-Charge. |
| 35 | Preparation of old surfaces and applying one coat of synthetic enamel paint over steel surface over 10cm width or girth complete all as specified and as directed. |
| 36 | Preparation of old painted surfaces of wood of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 37 | Preparation of newly plastered surface and applying two coats of premium acrylic smooth interior emulsion on wall and ceiling of approved colour with silicon additive and Color stay Technology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer\"s instructions applied over one coat of acrylic water based interior grade primer @ 0.9ltr (undiluted)/ 10 Sqmtrs diluted with water in (1:1) ratio and 1mm thick interior grade wall putty as per manufacture\"s instructions and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.Notes: - (a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the material i.e. paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE. |
| 38 | Complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint and loose plaster to be completely removed by skilled labour and repair of internal wall/ ceiling to be done with repair mortar to get even surface including preparation of old surface of wall/ ceiling by filling cracks by Berger Bison Putty/ crack fill paste of Berger Paints or equivalent make and make good smoothen surface by sand paper and applying two coats of premium acrylic smooth interior emulsion of approved colour with silicon additive and Color stay Technology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer\"s instructions applied over one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/ 10 Sq mtrs diluted with water in (1:1) ratio and 1mm thick exterior grade wall putty as per manufacturer\"s instructions and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI all as specified and directed. Allow 6-8 hrs to dry the surface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and directed.Notes: - (a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the material i.e. paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE. |
| 39 | Preparation of newly plastered surface and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive and Color stay Technology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/ 10 sq mtrs diluted with water in (1:1) ratio and 1mm thick exterior grade wall putty as per manufacturer\"s instructions and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.Notes: - (a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the material i.e. paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE. |
| 40 | Complete removal of existing treatment including fascias, cornices etc old plastered surface and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive and Color stay Technology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/ 10 Sq mtrs diluted with water in (1:1) ratio and 1mm thick exterior grade wall putty as per manufacturer\"s instruction and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.Notes: - (a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the material i.e. paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE. |
| 41 | Providing water proofing treatment to sunken floors all as given below: -(a) Making fillet of size 25mm x 25mm at corner of slab and wall with polymer modified cementitious (PMC) mortar consisting of one part of tapecrete P-151, two parts of cement and 6 parts of fine sand by weight.(b) Sealing of joints of pipe with epoxy putty CICO POXY LC or epoxy mortar CICO POXY 2125.(c) Cleaning the concrete surface by brushing and watering and applying a coat of tapecrete P-151 Acrylic Polymer Modified cementitious slurry consisting of one part of TAPECRETE P-151 and two parts of cement by weight. The coating shall be carried out upto 300mm above FFL and shall be allowed to dry for 4-6 hours.(d) Applying a coat of TAPECRETE brush topping 1.5mm thick consisting of one part of TAPECRETE P-151, two parts of cement and two parts of silica sand by weight and cured to 2 days.(e) Applying 15mm thick plaster in CM (1:4) mixed with CICO super @ 100ml per 50 Kg cement on treated surface.(f) Filling the sunken portion with PCC (1:5:10) type E-2 (using 40mm graded crushed stone aggregate) upto required level complete all as specified and as directed. (PCC shall be measured and paid separately under respective item). |
| 42 | Home Shield PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied, water-proofing membrane that is highly elastic and UV resistant with 10 years Warranty. ASTM D 6083-97a Waterproofing and heat reflecting system having following key performance properties. (i) UV resistant, prevent yellowing and weathering. (ii) Highly elastic upto 350% and crack bridging. (iii) Excellent adhesion on porous and non-porous substrates. (iv) Tensile Strength >10 N/Sqmm with GeoTextile fleece. (v) Solar Reflective Index (SRI) more than 109-111 ASTM E 1980-11. System: - First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer (or equivalent), Coverage : 0.2Kg/Sqm (with 50% dilution of water), Reinforcement : Geotextile 40 gsm, Second coat : Home shield roofkoat (or equivalent), Consumption : 0.5 Kg/Sqm, Third coat : HS PU roofkoat (or equivalent), Consumption : 0.8 Kg/Sqm. System buildup -1.5Kg/Sqm with geotextile of 40 gsm complete all as specified and as directed. |
| 43 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 44 | Glazed ceramic tiles 300 x 450 x 7mm thick on vertical surface such as in skirting, dado etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. |
| 45 | Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile not exceeding 0.18 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. |
| 46 | Vitrified light shade ceramic tiles 10mm thick (Square/ rectangular) polished area of each tile not exceeding 0.36 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed. |
| 47 | Vitrified light shade ceramic tiles 10mm thick (Square/ rectangular) polished area of each tile not exceeding 0.36 Sqm in skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar (1:3) complete all as specified and as directed. |
| 48 | Rendering 15 mm thick cement plaster (1:4) on fair faces of brick work or concrete surfaces and to be finished even and smooth without using extra cement complete all as specified and as directed. |
| 49 | Rendering 10 mm thick cement plaster (1:6) on other than fair faces of brick work or concrete surfaces and to be finished even and smooth without using extra cement complete all as specified and as directed. |
| 50 | Rendering 5 mm thick cement plaster (1:3) on fair faces of concrete surfaces as in ceiling, chajja, shelves etc. finished even and smooth without using extra cement complete all as specified and as directed. |
| 51 | Rendering 15 mm thick cement plaster (1:3) on other than fair faces of concrete surfaces as on fascia of roof slab, chajja, shelves etc. finished even and smooth without using extra cement (including all necessary scaffolding, lifting arrangement for three storey buildings on external surfaces) complete all as specified and as directed. |
| 52 | 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 53 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 45cm long and 15cm wide with chromium plated bracket guard and railing complete all as specified and as directed. |
| 54 | Supply and fixing in repairs Vitreous china wash down water closet (Pedestal Pattern) \"P\" or \"S\" trap (excluding flushing cistern and flush pipe) including PVC seat cover white closed pattern with recessed bottom and connection to drain or outgoing pipe and flushing pipe complete all as specified and as directed. |
| 55 | Supply and fixing in repairs Vitreous China wash basin, white, flat back, size 580 x 450 mm including 32 mm dia PVC waste pipe, chromium plated brass waste coupling 32 mm dia, pair of mild steel brackets or mild steel fastener/ bolts for fixing arrangements and 450 mm long PVC connection with PVC nut and washer complete at site all as specified and as directed. |
| 56 | Bib tap cast copper alloy with crutch or butterfly handle, chromium plated fancy type screwed for iron pipe, suitable for 15 mm bore complete all as specified and as directed. |
| 57 | Stop valve/ angle valve cast copper chromium plated screwed down high pressure with capstan head suitable for 15 mm bore, screwed both ends for iron pipe complete all as specified and as directed. |
| 58 | Brass chromium plated shower rose 125 mm size swivel type with connecting rod 15 mm bore complete all as specified and as directed. |
| 59 | Stop valve cast copper chromium plated concealed type screwed down high pressure with capstan head suitable for 15 mm bore complete all as specified and as directed. |
| 60 | 15mm bore pillar taps, cast copper alloy fancy type with capstan heads, chromium plated screwed down high pressure, screwed for iron pipe complete all as specified and all as directed by Engineer-in-Charge. |
| 61 | Tubular towel rail 20mm dia \"D\" type 60cm long between flanges chromium plated complete all as specified and as directed. |
| 62 | 15mm bore chromium plated wall mixer with bend pipe for overhead shower pipe for mixing hot and cold water with connecting legs and wall flanges screwed down for iron pipe and fixed complete all as specified and as directed.Makes: - Cera Cat Part No : F2006402 or equivalent in makes as mentioned in Group - 1 of Appx \"F\". |
| 63 | 16mm outer dia CPVC pipes SDR 11 and Plain CPVC SDR 11 fittings on concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down 15mm steel tubing complete all as specified and as directed. |
| 64 | 20mm outer dia CPVC pipes SDR 11 and Plain CPVC SDR 11 fittings on concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down 15mm steel tubing complete all as specified and as directed. |
| 65 | Cutting chases for concealed water tubing or concealed conduit and making good in cement mortar (1:3) of girth exceeding 10 cm and not exceeding 20 cm in brick wall complete all as specified and as directed. |
| 66 | Rotational moulded polyethylene water storage tanks 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I including dismantling of existing water tank, including 20mm ball valves, 20mm tank nipple complete all as specified and as directed by Engineer-in-Charge. |
| 67 | Stop valve 20 mm dia cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 68 | PVC (SWR) pipes 110 mm bore single socketed in any length with rubber joint fixed to wall or laid in trenches or in floor with steel clamps complete all as specified and as directed. |
| 69 | PVC (SWR) pipes 75 mm bore single socketed in any length with rubber joint fixed to wall or laid in trenches or in floor with steel clamps complete all as specified and as directed. |
| 70 | PVC (SWR) bends of 110 mm bore complete all as specified and as directed. |
| 71 | PVC (SWR) bends of 75 mm bore complete all as specified and as directed. |
| 72 | PVC (SWR) branch piece, single \"Y\" equal or unequal provided with access door of 110 mm dia complete all as specified and as directed. |
| 73 | PVC (SWR) floor trap plain including jointing with solvent cement 75 mm dia complete all as specified and as directed. |
| 74 | PVC (SWR) reducer of 110 mm dia complete all as specified and as directed. |
| 75 | PVC (SWR) vent cowl 110 mm bore complete all as specified and as directed. |
| 76 | PVC low level flushing cistern 10 litres capacity white with inlet ball value, float valve and handle including brackets, PVC flush pipe complete all as specified and as directed. |
| 77 | PVC connection 15 mm x 450 mm including brass check nut at both ends screwed for iron pipes of 15 mm bore complete all as specified and as directed. |
| 78 | Towel Ring chromium plated complete all as specified and as directed. |
| 79 | Supply and fixing in repairs Chromium plated Soap dish complete all as specified and as directed. |
| 80 | 25mm outer dia stainless steel decorative drapery rod (Model No - SS-25FL of Vista) of thickness 20 gauge and for every 01 RM length, provide 10 numbers stainless steel wings (Model No:-SS CRNG of Vista) with 50 mm dia and proportionate for part there off, with stainless steel brackets ( Model: - SS 25 BR, Vista) near to ends with stainless steel finials (Model: - SS-1 of Vista with adapter) for 25mm dia drapery rod at both ends complete all as specified and as directed.Notes: - The drapery rod shall be projecting 150 mm outer side from the clear opening of doors/ windows. (Including necessary fittings). |
| 81 | Stainless steel gratings of 125 mm with waste holes of PTMT (minimum weight of 40 grams) complete all as specified and as directed. |
| 82 | Stainless steel butt hinges 100mm long medium weight cold rolled complete all as specified and as directed. |
| 83 | Aluminium tower bolt of size 150 mm complete all as specified and as directed. |
| 84 | Aluminium handle of size 150 mm complete all as specified and as directed. |
| 85 | Aluminium handle of size 100 mm complete all as specified and as directed. |
| 86 | Mild steel helical/ ordinary rat tail rod pattern door spring 300 mm including roller and roller plate complete fixed with welding complete all as specified and as directed (ISI marked). |
| 87 | Aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 88 | Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed in repair with stainless steel wire staples complete all as specified and as directed. |
| 89 | Aluminium alloy, anodised, sliding door bolt 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed in repair complete all as specified and as directed. |
| 90 | Aluminium anodised handles 125 mm of extruded section and fixed in repair complete all as specified and as directed. |
| 91 | Aluminium anodised barrel tower bolts 150 mm of extruded section and fixed in repair complete all as specified and as directed. |
| 92 | Mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete as fixed in repair complete all as specified and as directed. |
| 93 | Cleaning of the exposed concrete slab and repairing the surface irregularities like cracks, potholes, as per manufacturer\"s method statement by Berger HS Rapairo (or equivalent) along with HS Latex Plus (or equivalent) and cement in mixing ratio of (1:4) where ever required complete all as specified and as directed. |
| 94 | Cleaning/ clearing of sewage line (including manholes) 100mm to 150mm bore of any description, underground at any depth, removing any type of blockage including desilting, descaling and dechoking of drains as well as manholes and depositing the sludge in a pit (including digging of pit) not less than 100 metres away from the site of cleaning and covering the sludge with layer of 2.5cm thick layer of earth and spraying unslacked lime on the pit and make line smooth functional complete all as specified and as directed. |
| 95 | Cleaning of blocked WC/ floor trap/ gully trap etc. including and upto first manhole manually and well flushing with clear water, making the seat functional including deposting the sludge in a pit (including digging of pit) not less than 100 meter away from site of cleaning and covering the deposited sludge with minimum 25cm thick layer of earth and spreading unslacked lime on the pit complete all as specified and as directed by Engineer-in-Charge. |
| 96 | E/M Portion: -Taking down old unserviceable copper/ aluminium point wiring concealed/ batten (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/ iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed. |
| 97 | Point wiring with 1.5 Sqmm single core multistranded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 Sqmm copper conductor flexible FRLS insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall, plastering after concealing conduit, including modular galvanised flush boxes of suitable size and white cover plate with frame suitable modules as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer-in-Charge for the following: - |
| 98 | Description all as per Ser Item No 97.00 here-in-before but 5 Amps socket outlet on same board complete all as specified and as directed. |
| 99 | Description all as per Ser Item No 97.00 here-in-before but socket outlet 5 Amps on independent board complete all as specified and as directed by Engineer-in-Charge. |
| 100 | Description all as per Ser Item No 97.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed. |
| 101 | Description all as per Ser Item No 97.00 here-in-before but for one bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 Sqmm size complete all as specified and as directed. |
| 102 | Modular switch 1 way 6A, 1 module, 240 Volts ISI marked complete all as specified and as directed. |
| 103 | Modular switch socket combination, 6A, 6 pin 3 module, 240 volts ISI marked complete all as specified and as directed. |
| 104 | Modular switch socket combination, 16A, 6 pin 3 module, 240 volts ISI marked complete all as specified and as directed. |
| 105 | Modular fan step regulator, 1 module, 240 Volts ISI marked complete all as specified and as directed. |
| 106 | Distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud TPN 4 way 415 volts double door complete all as specified and as directed by Engineer-in-Charge.Note: - Distribution board and MCBs should be of same make. |
| 107 | Distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge.Note: - Distribution board and MCBs should be of same make. |
| 108 | 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed. |
| 109 | SPN 32 Amp rating 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed. |
| 110 | 415V, 10 KA \"B\" curve TPN 40 to 125 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the distribution board complete with connection, testing and commissioning complete all as specified and as directed. |
| 111 | Calling bell Ding Dong/ buzzer, AC 230 Volts single pole complete all as specified and as directed. |
| 112 | Bell push, flush type single pole, 5 Amp, 240 Volts complete all as specified and as directed. |
| 113 | Ceiling rose 3 terminal surface type complete all as specified and as directed. |
| 114 | Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 115 | Self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed. |
| 116 | LED lights fitting 1 x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen/Watt, 6500K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4\" ft long) with LED rod 20 watt, 230 Volts, 50 Hz complete all as specified and as directed. |
| 117 | Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring.Note: - Wiring shall be done in proper colour coding. |
| 118 | Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 10 Sqmm for phase and neutral and one run of 10 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length.Note: - Wiring shall be done in proper colour coding. |
| 119 | Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolts, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 precast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal etc complete all as shown in electrical plate No 3 of SSR Part - I and testing on completion complete all as specified and as directed. |
| 120 | Ceiling fans complete with blades, hanging hooks and accessories, 230 V, 1200 mm sweep minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) including checking of electric sup to the fan point andf hanging of new fans on new hooks etc complete all as specified and as directed. |
| 121 | Exhaust fan, steel body AC single phase, 230 V of size 300mm/ 400mm sweep with blades and frame and louvers, including making holes for 300 mm dia exhaust fan of suitable shape and size into or through brick walls including plastering for making good to the original surfaces complete all as specified and as directed. |
| 122 | Wall mounted fan made of good quality PVC body AC single phase, 230V of size 400mm sweep with blades and frame including making proper connection with 1.5 Sqmm copper conductor in ceiling rose complete all as specified and as directed by Engineer-in-Charge. |
| 123 | 32 Amp, 240 Volts Double pole switches for AC connections complete all as specified and as directed. |
| 124 | Vertical Distribution board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCBs 32 Amp single pole and should be IP-43 protected with copper bus bars, neutral links, Earthing bar complete all as specified and as directed including taking down old unserviceable distribution board/ MCB any type.Note: - (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 Volts with adjustable thermal settings.(ii) MCB\"s shall be measured and paid separately.(iii) TPN distribution board and MCCB should be of same make. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail