| 1 | Taking down chowkats with shutters but without taking off shutters from the frames exceeding 1.5 sqm and not exceeding 4.0 sqm each complete all as specified and directed. |
| 2 | Taking down chowkats with shutters but without taking off shutters from the frames not exceeding 1.5 sqm each complete all as specified and directed. |
| 3 | Taking up or down15 mm dia steel tubing and connectionscomplete all as specified and directed. |
| 4 | Taking up or down 25 mm dia steel tubing and connectionscomplete all as specified and directed. |
| 5 | Dismantling of PVC water tanks of capacity exceeding 500 Ltr but not exceeding 1000 Ltrs complete all as specified and directed. |
| 6 | Demolition of brickwork stone/boulder masonry built in cement mortar complete all as specified and directed. |
| 7 | Demolition of unreinforced cement concrete in ground floorsand pavings not exceeding 15 cm thickness(below or above ground level) complete all as specified and directed. |
| 8 | Demolition of Reinforced cement concrete in any position not exceeding 15 cm thickness(below or above ground level)including cutting and removing reinforcement bars complete all as specified and directed. |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 10 | Dismantling pre painted galvalume sheet roofing of any description fixed in any position with nails complete all as specified and directed. |
| 11 | Dismantling Wallandceilingboards(fibre,pulp, insulation, etc.) or insulationboards/slabs/blankets, any thickness, including coverfillets complete all as specified and directed. |
| 12 | Dismantling of AC/RCC drain pipes100mm dia complete all as specified and directed. |
| 13 | Removal of excavated/ demolished building materialsobtained fromitem Nos 1 to 12 here in beforeoutside MD land ( to a distance of 15 Km approx) after obtaining necessary clearance from local Govt Authourity.Rate quoted by Contractor for this itemis including this aspect complete all as specified and directed. |
| 14 | Taking down the unserviceablepoint wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling roses, pendent regulators, sockets ,light fittings/fame proof lights,flame proof switches etc any light points andcomplete all specified and directed |
| 15 | Taking down unserviceble submain wiring any size /any capacity complete all as specified and directed. |
| 16 | Taking down unserviceble DBs any size / any capacity complete all as specified and directed. |
| 17 | Taking down unservicebleMCB SP/SPN any size /any capacity complete all as specified and directed. |
| 18 | Taking down ofceiling fan, dismantle blades anddeposit the ceiling fan at E&M store yard complete all as specified and directed. |
| 19 | Taking down Exhaust fan, dismantle blades anddeposit the exhaust fan at E&M store yardcomplete all as specified and directed. |
| 20 | Taking up old earthing any size/any type complete all as specified and directed. |
| 21 | Takingdown earth strip/wire any size/any type complete and deposite in E&M store yard all as specified and directed. |
| 22 | Dismantling and taking out carefully GI pipe 50mmdia including earth work if required complete all as specified and directed. |
| 23 | Dismantling and taking out carefully GI pipe 25mmdia including earth work if required complete all as specified and directed. |
| 24 | DismantlingXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area up to 400 Sqmm completeand deposite to E/M store yard all as specified and directed. |
| 25 | Taking down Air conditioner any size /any capacity and deposite to E/M store yardcomplete all as specified and directed. |
| 26 | Taking down LT panel any size /any capacity and deposite to E/M store yardcomplete all as specified and directed. |
| 27 | Material & Labourfor cutting road / hard standing to depth not exceeding 60 CM and to width not exceeding 45 CMand making good the disturbed surfacesby cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate complete all as specified and as directed. |