| 1 | SH-1 Wiring |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.ii) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.iii) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 5 | SupplyinganddrawingfollowingsizesofFRLSPVCinsulated copperconductor, singlecorecableintheexistingsurface/ recessed steel/ PVC conduit as required. ii) 3 x 1.5 sq. mm |
| 6 | SH-2MCCB, MCB & DB |
| 7 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)ii) 16 way, Double door |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) Single pole |
| 9 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. ii) Double pole |
| 10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. iii) Triple pole and neutral |
| 11 | Supplyingandmakingendterminationwithbrass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. (i) 3.5 X 35 sq. mm (32mm) |
| 12 | Supplying and fixing of 4 way, 100 AmpsWall Mounted Busbar Chamber, 415 volts,Busbar made of ETP Grade Copper, Standard - IS 61439-6, Colour - RAL 7035 Semi Glossy, DB Sheet Thickness - 1 mm & 1.6mm, Ambient Temperature - 40ºC, Support Material for Busbar - DMC, Complete with connections, etc. as required. ( make like: Havells/ Anchor/ legrand,ABB, Schinder) |
| 13 | Supplying and fixing of FP 100 Amps MCCB, Breaking capacity- 25 KA, 415 Volts, 50 Hzs along with Sheet enclosures including both side spreader terminal kit for connection, drilling and fixing on wall and making connections etc. as required. (Make like- Havells (A Frame series) /Anchor/ legrand/ ABB/ Schinder /C&S etc. |
| 14 | Supplying and fixing of FP 50 Amps MCCB, Breaking capacity- 25 KA, 415 Volts, 50 Hzs along with Sheet enclosures including both side spreader terminal kit for connection, drilling and fixing on wall and making connections etc. as required. (Make like- Havells (A Frame series) /Anchor/ legrand/ ABB/ Schinder /C&S etc. |
| 15 | SH-3EARTHING |
| 16 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories,andprovidingmasonryenclosurewithcoverplate havinglocking arrangement and wateringpipe etc. with charcoal/ coke and salt as required. |
| 17 | Providing and fixing 6 SWG dia GI. wire on surface or in recess for loop earthing as required. |