| 1 | Execution of works |
| 2 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below |
| 3 | Provision for display of photo of size: 30\"\"x20\"\" by framing with 2\"\" fibre frame with non glare glass including printing of photo in good quality paper of GSM ranging from 260-300 complete in all respect as per direction of engineer in charge. (As per Analysis) |
| 4 | Provision for photograph stand (Size: 3.50x2.15 m)having cabinet at the bottom for storage using 19 mm thick good quality ply board veenering the outer surface and making good with wooden batten to keep erect for display of photographs as per approved drawing. (As per Analysis) |
| 5 | Provision for supply and installation of following items having ISI mark of reputed brand for eletrification of the display gallery room. (As per prevaling market rate) |
| 6 | Celling Light (12 Watt) |
| 7 | Track Light 9 watt (along with frame) |
| 8 | Modular Switches |
| 9 | 12 Module Modular Switch Board |
| 10 | 12 Module Modular Switch Plate cover |
| 11 | Socket |
| 12 | Conduit Pipe 1\" (10 ft) |
| 13 | Copper Wire 4 sq mm |
| 14 | Copper Wire 2.5 sq mm |
| 15 | Copper Wire 1 mm (90 metre Coil) |
| 16 | Screw 1\" (Packet) |
| 17 | Screw 2\" (Packet) |
| 18 | PVC Gutka (packet) 1\" |
| 19 | PVC Gutka (packet) 2\" |
| 20 | Adhesive Tape |
| 21 | Grinder Machine blade |
| 22 | Shutter Exhaust fan |
| 23 | Installation Charges(Lump Sum) |
| 24 | roviding and fixing false ceiling at all heights including providing and fixing of frame work made of special sections , power pressed from M.S. sheets and galvanized with zinc coating of 120 gms / sqm ( both side inclusive ) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm , at 1200 mm centre to centre , one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts , other flange of cleat fixed to the angle hangers of 25x10x0,50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre , to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm , at 450 mm centre to centre , shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction , including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long , the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre , with 25 mm long dry wall screws @ 230 mm interval , including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3,5 x 25 mm at 230 mm c / c , including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board , all as per manufacturer\"s specification and also including the cost of making openings for light fittings , grills , diffusers , cutouts made with 12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095- ( Part 1 ) 2011 ( Board with BIS certification marks ) 12.5 mm thick tapered edge Class Reinforced Gypsum ( GRG ) board conforming to IS : 2095- ( Part 3 ) 1996 ( Boards with BIS certification marks ) frame of perimeter channels suitably fixed . all complete as per drawings , specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095- ( Part 1 ) 2011 ( Board with BIS certification marks ) 12.5 mm thick tapered edge Class Reinforced Gypsum ( GRG ) board conforming to IS : 2095- ( Part 3 ) 1996 ( Boards with BIS certification marks ) (DSR 2023) |
| 25 | Supply and installation of 2 ton split inverter AC (minimum three star)of reputed brand inwith all appliances and necessary electric connection complete in all respect. |
| 26 | Supply and Installation of following items of good quality and reputed brand for upgradation of Security System( CCTV & Fire alam system) of the museum. |
| 27 | i) For CCTVa) 5 MP IP Night vision Camera(Dome) |
| 28 | b) Cat 6 Cable (90 M) |
| 29 | c) 4\"x4\" Box |
| 30 | d) 20 mm Saddle Clip (Packet) |
| 31 | e) Conduit Pipe(1\") (10 ft) |
| 32 | f) Fexible Pipe(1\"\") |
| 33 | g) R-J 45 Connector |
| 34 | h) Adhesive Tape |
| 35 | i) Installation Charges |
| 36 | ii)For Fire Alarm Systema) Fire Smoke Detector |
| 37 | b) Panel Set |
| 38 | c) Fire Alarm Box |
| 39 | d) 2 Core copper 1.5 sqm Cable (90 m) |
| 40 | e) Electric Power Box (16 Amp) |
| 41 | f) Copper Wire 2.5 sq mm |
| 42 | g) Conduit pipe (1\") (10 Ft) |
| 43 | h) Installation Charges |
| 44 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand)( |
| 45 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 46 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 47 | Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 48 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specification:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 49 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |