| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 2 | ALL KIND OF SOIL @40% |
| 3 | ORDANARY ROCK @20% |
| 4 | HARD ROCK(B.P)@ 40% |
| 5 | Earth work in excavation by mechanical means(hyd excavator) in trenches for foundation ,drains ,pipe etc. over areas (Exceeding 30 m and upto 1.5 mtr in depth. I mtr in width as well as 10 sqm. on plan) including disposal of excavated earth upto I Intr from cutting edge. disposed ealth to be leveled and neatly dressed in : |
| 6 | ALL KINDS OF SOIL 40% |
| 7 | ORDINARY ROCK 30% |
| 8 | HARD ROCK (BP) 30% |
| 9 | Filling available excavated earth (excluding rock) in trenches plinth, sides of foundation etc in layer not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50cm and lead up to 50 m and lift upto 1.5 mtr. |
| 10 | STONE SOLLING Dumping of stone including cost of stone (in horizontal on level) |
| 11 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (crushed) |
| 12 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (crushed) |
| 13 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50 mm thick with 20mm nominal size stone aggregate. (Use Of Portland Pozzolana Cement Is advised as Per Green Building Guidelines OR 25% replacement of Ordinary Portland cement with fly ash by weight of cement used in structural concrete.) |
| 14 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundation, footing bases of column |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. |
| 18 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete |
| 19 | Providing & fixing stabilized mud concrete solid blocks (adobe) with 3% cement,masonry up to floor five level including hoisting and setting in position in mudmortar using approved quality mud with carriage ofmaterial complete. |
| 20 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for seperately) First classkail wood |
| 21 | Providing and fixing panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for seperately,all complete as per direction of Engineer-in-charge.(second class teak wood 35 mm thick shutter) |
| 22 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick.Second Class teak wood |
| 23 | Providing and fixing of glass panes, of thickness 4.0 mm (weighing not less than 10 kg/sqm) including all type of fixture by way of wooden beading of 1 st class kail wood etc complete. |
| 24 | CEMENT PLASTER (IN COARSE SAND) 12mm Cement plaster of mix 1 : 4 ( 1 cement : 4 coarse sand) |
| 25 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer (Note: It Should have Low or No VOC as per Green Building guidelines) |
| 27 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. (Note: It Should have Low or No VOC as per Green Building guidelines) |
| 28 | New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm.(Note: It Should have Low or No VOC as per Green Building guidelines) |
| 29 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) (Note: It Should have Low or No VOC as per Green Building guidelines) |
| 30 | Preparing newly primed wooden surface for painting by way of filling of putty sand papering rubbing complete. |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. (Note: It Should have Low or No VOC as per Green Building guidelines) |
| 32 | Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with: |
| 33 | Providing and fixing accessories of standard and quality make of approved manufacturer including all necessary fixtures required. |
| 34 | Classical cylinderical door lock for room door of approved brand Godrej or equivallent or as per engineer incharge |
| 35 | AL Drop for room doors of approved brand or as per site engineer |
| 36 | T- Bolt for doors of approved brand or as per site engineer |
| 37 | Handles for door of approved brand or as per site engineer |
| 38 | Providing wood work in frames of walls,false ceiling, partitions etc. sawn and fixed in position :KAILwood (Note : False Celling Design should be as per engineer in charge which may be of different level celling ) |
| 39 | Providing and fixing 12 mm thick tongued and grooved Pine wood (Soft Wood ) 4-5 inch in width panelling or wall panels in walls and celing includining all necessary fixtures including cornice with necessary screws, priming coat on exposed surface etc., complete. Brand - Rait Wood |
| 40 | Preparing newly prepared panneled surface for polishing by way of filling of putty , sealer and sand papering rubbing and applying hard polish,glossy polish in sequance over the prepared surface complete job |
| 41 | Providing and fixing thermal insulation with specified wool and density conforming to IS: 8183, 50 mm thick, wrapped in 200G Virgin Polythene bags fixed to walls with screws, rawl plugs and washers and held in position by criss-crossing GI wire etc. complete as per directions of Engineer-incharge. |
| 42 | Wooden planking, tongued and grooved in flooring including fixing with iron screws complete: 25 mm thick Second class teak wood |
| 43 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 44 | Providing and fixing of cornice of 2nd class k-wood inluding all fixing accessories |
| 45 | P/F Stainless steel 304 Grade Square Shaped Sink Vessel Sink (21 X 18 X 8) inches (Steel) of approved brand and manufacture Hindware/Jaguare/Imperio/ Kaff and any other approved brand as per Engineer Incharge including all accessories |
| 46 | Providing hoisting and fixing trusses/ purlins,rafter/posts.Post plated of truss components of Ist class budloo wood.fir wood including cost of screw etc Complete. |
| 47 | Providing and fixing 52mm thick weather boarding of budloo wood plained on one side. |
| 48 | Providing and fixing 250mm wide eves boarding of budloo wood plained on one side |
| 49 | Providing ridges or hips of width 60cm overall width plain G.S. sheet fixed with poymer coated J. or L hooks, bolts and nuts 8mm G. I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275gm /m2 specifications as per engineer in charge Please Enable Macros to View BoQ information |