| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of soil : |
| 2 | Supplying and laying of stone soling hand packed tightly incl ramming watering and filling of interstices incl all carriage complete job |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)(under floors) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platforms. |
| 9 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) i/c Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 10 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position withold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Imported foreign wood |
| 11 | Providing and fixing panelled or panelled and glazed shutters for doors and windows and clerestory windows including ISI marked black enamelled MS butt hinges with necessary screws excluding panelling ( approved imported KD wood) 30-35mm thick |
| 12 | Providing and fixing 30- 35 mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4mm with wire of dia. 0.63 mm for doors, windows and clerestory windows including ISI marked bright finished or / and black enameled M.S. butt hinges i/c wooden beading with necessary screws. Imported KD wood |
| 13 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Ply wood 5 ply, 9 mm thick Decorative ply wood both side decorative veneer (type 1) conformingto IS 1328 BWR type |
| 14 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 15 | 15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 6 ( 1 cement : 6 fine sand) |
| 16 | 40mm thick cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished wit a floating coat of neat cement including carriage of all materials from approved sources upto site of work complete |
| 17 | Providing glass panes 4mm thick) clestory windows suttets (Area of opening for glass panes excluding portion inside shall be measured) |
| 18 | EXTERIOR FINISHING Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 19 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 20 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more including all carriage |
| 22 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat and paint of approved steel primer all complete. Welded including all carriage |
| 23 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2 incl carriage |
| 24 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 25 | Providing and fixing bright finished brass fittings with necessary screws etc. complete. :L Drop |
| 26 | tower bolt: 100mm |
| 27 | handles:100 mm |
| 28 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels (Area of slab over 0.5 sqm) 16mm |
| 29 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 30 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 31 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.PN-16 pipe, 16mm OD(SDR-7.4) |
| 32 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.PN-16 pipe, 20mm OD(SDR-7.4) |
| 33 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 34 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for singlepipe line |
| 35 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board 610x510mm bowl depth 200mm |
| 36 | Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete 40 mm dia |
| 37 | Providing and fixing brass bib cock of approved quality. 19.9.1 15 mm nominal bore |
| 38 | Providing and fixing CP Brass single lever wall mixer of quality and make as per directions OF EIC |
| 39 | Providing and fixing MS grating of approved quality and colour.75 mm nominal dia. |
| 40 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 41 | P/F Hot water geyser (25Itr capacity) of approved design andmake i/c all fittings complete |
| 42 | Providing and fixing of Aluminium work complete in Frames, shutters, glasses, ACP sheets with all fittings and fixtures complete |
| 43 | Carriage of materials by mech transportSand and Bajri |
| 44 | Bricks |
| 45 | Cement |
| 46 | Electric partWiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK) excluding the cost of conduit. |
| 47 | Supply, Installation, Testing and Commissioning of 18W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro/Panasonic). |
| 48 | Supply, Installation, Testing and Commissioning of 50W (Havells/ PhillIps/Wipro skyline ) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w ,CRI>80 ,CCT>5000 ,Avg Life L70 50000 hours ,No haremful UV and IR radiators, Operating Temp -10 to 45C ,Surge Voltage Protection, IP66 Protection and impact resistance of IK07.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. |
| 49 | Supply, installation, testing and commissioning of 1200 mm BEE Star rated energy-efficient ceiling fan, complete with 3 Nos. aluminum blades, downrod, canopy, capacitor, safety pin, nuts, bolts and washers, suitable for 230 V, 50 Hz AC supply. The fan shall have air delivery not less than 220 m³/min, rated speed (RPM) between 340–380 (as per manufacturer’s specification), power consumption not exceeding 50 watts, service value ≥ 6.0, noise level ≤ 60 dB, insulation class ‘B’ and insulation resistance > 2 MΩ. Fan shall be of approved make such as Usha / Havells / Crompton / Orient or equivalent, including installation, online RPM verification, testing, commissioning and handing over to the Engineer-in-Charge, with minimum 2-year manufacturer warranty. |
| 50 | Supplying and fixing ISI-marked 6 A, 250 V modular step-type electronic fan regulator (2 Module), conforming to IS:3854 or latest IS standards, mounted on suitable modular plate with GI flush box, including wiring connections, testing and commissioning, of approved make such as Anchor Roma / Legrand / Schneider / Havells, complete as per direction of the Engineer-in-Charge. |
| 51 | Supply, Installation, Testing and Comm. Of 200/250mm sweep exhaust fan Shutter type of havell /Bajaj/ Crompton/equivalent make as directed by engineer incharge,Air Flow capacity >850cmph, 35-50Watts,Noise level 44db, 1200 rpm,water resistant, including making of space in wall/ window as per site requirement and necessary connections.The job includes replacement warranty of fixture if damaged/burn out what so ever reason for a period of two years reckoned from the date of sucessful commissioning / handing over of site to the intending department.(To be got approved before installation from EIC) |
| 52 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make). |
| 53 | Supplying and fixing of GI box along with modular base and cover plate for modular sockets, switches in recess etc as required6 module (200mm x 75mm) |
| 54 | Supplying and fixing of 5pin 5-10A socket and 5-10A switch on existing modular plate, incl connections etc as required. (Havells/SSK/Anchor/ABB/Schneider) |
| 55 | Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required.(Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) including the cost of conduit. |
| 56 | Wiring for 5- 10A socket out lets for computer (inverter) with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required.including the cost of conduit. |
| 57 | Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent). |
| 58 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired. |
| 59 | Supply and fixing of 12 way, Double door surface/ recess mounting, Horizontal type, 240 V.SPAN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tunned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havelis/L.egrand/SSK/Schnider/ABB) |
| 60 | Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V,10 KA \"C\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCBdistribution board complete with necessary connections. |
| 61 | Supply, installation, testing and commissioning of 32-40A DP rating 240/415V,10 KA \"C\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 62 | Supply, installation, testing and commissioning of 63A DP rating 240/415V,10 KA \"C\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 63 | Supply, installation, testing and commissioning of 100A 4P connector Legrand/ Havells/L&T complete with necessary connections and mounted inside a suitable PVC enclosure. |
| 64 | Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, including the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent). A)2x 2.5 sq mm + 1x 2.5 sq mm Lighting circuit |
| 65 | B)2x10 sq mm |
| 66 | Supply, laying, connecting and commissioning of 16 sq mm 2 core XLPE/ PVCInsulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped. (Over head/ under ground). |
| 67 | Earthing with Gl earth pipe 4.5 mtr. Long 40 mm dia. Including accessorles and providing masonry enclosure with cover plate having locking arrangements and watering pipe, trenching and filling with charcoal/coke and salt. |
| 68 | Providing and laying earth connection from earth electrode with 6 SWG dia wire in 15 mm dia G.l. pipe from earth electrode including connection with GI thimble excavation and re-filling as required. Please Enable Macros to View BoQ information |