Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L Repairto door shutters for easy closing/opening(size upto 3 Sqm) including minor repair and easing, adjustment/alignmentto openable with assessories and including taking down and refixing, tightening of hinges or changing the position of hinges,welding of hinges door to frame adjustment of tower bolts, sliding bolts with new screws etc,complete all as specified and directed. |
| 2 | Taking down chowkats or frames (wooden/steel)including shutter (without taking off shutters from the frame) area n exc. 1.5 Sqm each all as specified and as directed. |
| 3 | Taking down chowkhat or frame (wooden/steel) exceeding 1.50 Sqm and not exceeding4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed. |
| 4 | Taking down shutters of any description exc 1.0 Sqm andn.exc 2.0 Sqm each complete all as specified and directed. |
| 5 | S&F 2nd class hardwood Plain, solid, straight, chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 6 | Supply and Fixing 30 mm thick factory made flush shutter solid core construction with block board core and plywood face panels, comercial type on both faces complete all as specified and directed. |
| 7 | Supply and Fixing Factory made soild PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with \"C type Gl or 40 x 20 x19 of MS pipe as stiffner & supplying & fixing in frame at site as per specifications & drawing complete all as specified and directed. |
| 8 | S&F Aluminium, anodised, barrel tower bolts 200mm long of extruded section all as specified. |
| 9 | S&F Aluminium handles 150mm size, cast type, anodised complete all as specified. |
| 10 | S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 11 | S&F overall length of cover plate 150mm long Floor door stopper of aluminium alloy body & tongue, anodised, with hard drawn steel spring fixed in floor all as specified and directed. |
| 12 | S&F 100mm butt hinges stainless steel complete all as specified and directed. |
| 13 | M&L Preparation of new wooden surfaces over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.. |
| 14 | M & L for preparation of old painted wooden surfaces of anydescription, not otherwise described, exceeding 10cm inwidth or girth and applying one finishing coat of synthetic enamel paint complete all as specified and directed. |
| 15 | Supply & Fixing of UPVC glazed 3 track-2 panel sliding windows with mesh made out of multi chambered uPVC sections with TPE gaskets having isolated drainage and reinforced with Galvanized iron profiles throught out the window. The outer frame having an overall size of 108 x 48 mm with reinforcement of 1.2mm thickness and sash with overall size of 38 x 61 mm with reinforcement of 1.2 mm thickness mesh sash of overall size 38 x 58mm Fiber mesh reinforced with 1.2 mm of GI. Glazing bead for fixing of glass shall be of size 16mm x 19mm and TPV gasket. Windows will be provided with 5mm thick plain float glass and stainless steel wiremesh, With \"Astrapia\" hardware or equivalent & Single point locking system of flush lock. Wall thickness of frame & sash shall be 2-2.2mm complete all as specified and directed. |
| 16 | S&F in repair manually operated polyester fabric vertical venetian blinds of approved colour and pattern of any size and thickness of 0.45mm (+/-0.05mm) including high strength aluminium alloy channel fixing with two Nos clamp and semi transparent type including all connected fittings and fixtures for windows,ventilators etc complete all as specified and directed. |
| 17 | S&F 12 mm thick toughen glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required and glass fixing with fish mouth channel & patch fittings included as approved material, fixing with all accessories and glass joints should be filled with weather proof silicon including fixing to wall for all arrangments and opening push and pull arrangements for double door & for top and bottom for pivot and lock patch and including door floor spring automatic arrangements materials and fixing including, permanent fixing wall for all arrangement including fittings, complete all as specified and directedNote:- (a) Glass fixing to wall and opening arrangement necessary all fitting and screws included as directed by Engineer in Charge.(b) Glass fixing with fish mouth channel and glass joints should be filled with weather proof silicon, MS portal materials and fixing cost included as directed by Engineer in Charge.(c) The above cost included for double glass door opening (push and pull type) any size, including all materials and necessary fittings for all fixing arrangement. |
| 18 | S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel covert governing pivot made of brass, other parts made of mild steel heavy duty including taking down existing complete all as specified and directed. |
| 19 | S&F Stainless steel for glass door handles of size 400 mm, minimum 25mm dia, SS 304 and H type of approved pattern and make, suitable for toughen glass fixed complete all as specified and directed |
| 20 | S&F in repair powder coatedaluminium framewith all fixing arrangementsfor doors, sliding windows andventilators/ partitions etcwith one or more rebates including joining cleat for fixing etc aluminium section of powder coating not less than 50 micron completeall as specified and directed. |
| 21 | S&F in repair Powder coated anodised aluminium windows, and ventilator shutters, sliding type without sash bars, aluminium sections weighing not less than 0.55 Kg/m (powder coating not less than 50 micron) including necessary joining cleats glazing clips, rubber packing, anodised aluminium fittings suitable lock with roller complete all as specified and directed. |
| 22 | S&F frosted glass 4.0mm thick, pin head typen exc 0.5 sq.m in each pane and fixed. completeall asspecified and directed. |
| 23 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete one all as specified and directed. |
| 24 | S&F 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50 sqm in each pane complete all as specified and directed. |
| 25 | S&F 4 mm thick sheet glass ordinary quality and glazing complete in square exc 0.50 sqm in each pane complete all as specified and directed. |
| 26 | S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete including taking down existing one from UPVC/Alumnium/ wooden frameall as specified and directed. |
| 27 | S & F in repair 18/19 mm thick ,water proof plywood , fixed to Cupboard work in any position with nails including removal of old boards of any description complete all as specified and as directed. |
| 28 | S&F in repair powder coated Stainless steel curtain rod fancy type (colour as approved) of 22/25mm bore diaincludingSS brackets, stops, rollers, etc. andfixed to wall with steel screws complete all as specified and as directed . |
| 29 | S&F PVC beading for cupboard work, colour and pattern as approved including taking down existing one complete all as specified and as directed |
| 30 | S&F Aluminium body door closer hydraulically regulated,designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed including taking down existing one complete all as specified and directed. |
| 31 | S&F Decorative laminates of 0.90 mm thick type matt finish, fixed with adhersive, colour and pattern as approved. including taking down existing one complete all as specified and as directed. |
| 32 | S&F Stainless steel auto hinges of size and approved pattern and make suitable for base/wall unit of cupboard including taking down the existing one complete all as specified and directed. |
| 33 | S&F Stainless steel handles of size 100 mm of approved pattern and make suitable for Base/Wall unit of modular kitchen including taking down the existing one complete all as specified and directed. |
| 34 | S&F in repair looking mirror of size 600mm x 450mm on commerical ply wood 6mm thick with PVC/ wooden moulding beading fixed to wooden plugs with chromium plated brass, screws and cup, washers, aluminium frame and fixed complete all as specified and directed. |
| 35 | Supply and fixingAnodized aluminium size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with hangers of GI wire of suitable dia (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and 10mm thick PVCinsulation panels with EPS stuck to 1mm printed PVC sheet , fixed to sheet suitably placed in false ceiling grid made of Aluminium/G.I./ M.S.as per specification and drawing complete all as specified and directed. |
| 36 | M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames/UPVC frames glazed with putty or fixed with beads and material and labour for4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm in each pane complete all as specified and directed. |
| 37 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 38 | M&L RCC, Cement concrete Type B0 1:2:4 (12.5mm graded aggregate) as in floor/roofSlab and roof projectionSlabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slabs and in shelves and the like similar work complete all as specified and directed. |
| 39 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, column, beam landings and similar work n exc 200mm thick complete all as specified and directed. |
| 40 | M&L MS TMT bars 10 mm dia and above , cut to length ,bent to shape required , including cranking , bending , spirally for hooping forcolumns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and directed. |
| 41 | M&L Cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed . |
| 42 | M&L Pre-cast PCC 1:3:6 type C1 (20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 of any description and demolition of old brick work or stone/boulder masonry, built in cement mortar or cement lime mortar complete as specified and directed. |
| 43 | M&L for rendering 15mm thick cement plasterin CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 44 | M&L Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 45 | M&L PCC (1:4:8) type D2 using 40mm graded aggregate, 75mm thick as in sub base of floor finished even and rough to receive top layer and including demolition ofcement Concrete (un reinforced) of any description and in anypositionnot otherwise specifically provided complete all as specified and directed.. |
| 46 | Complete removal of existing treatment ofold walls and washing, rubbing down, and applying plaster of paris putty of 1mm thickness over plastered surfaces to prepare the surface even and smooth painted surfaces and applying two coats of oil bond distemper over a coat of primer all as specified and directed. |
| 47 | Material and labourfor Preparation of old plastered or unplastered surfaceof ceiling brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applyingone coat of white wash complete all as specified and directed. |
| 48 | M&L for preparation of old plastered surfaces, complete removal of existing treatmentof wall by using pressure washer, removal all dirt and dust, applying water proofing putty and applying two coat of exterior emulsion weather proof paintover a coat of primer complete all as specified and as directed. |
| 49 | M & L for preparation of old painted steel and iron surfaces of any description exceeding 10 cm in width or girth and applying one finishing coat of synthetic enamel paint complete all as specified and directed. |
| 50 | M&L Vitrified Ceramic tiles 10 mm thick, lightshade (square/ rectangular) polished, area of each tile not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6complete including dismantling of existing old flooring tiles and disposal to outside MD land complete all as specified and directed. |
| 51 | M&L Vitrified Ceramic tiles 10 mm thick, lightshade (square/ rectangular) polished, area of each tile not exceeding 1.00 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6complete including dismantling of existing old tiles and disposalto outside MD land all as specified and as directed. |
| 52 | Material and labour for 25mm thk PCC 1:2:4 type B-0 using 12.5 mm graded stone agg as wearing coat for layingfloor finishes, finished even and fair to receive tiles including necessary demolition of old concrete complete all as specified and as directed. |
| 53 | Taking downcementplaster on stone/brick or ceiling wall etcincluding racking out of joints hacking for keys scrubbing down with water etc complete all as specified and directed. |
| 54 | M&L for cement plaster rendering 15mm thick on fair faces of brick/concrete surfaces with two coats i.e. (10mm thick backing coat in CM 1:6 and 5mm thick finishing coat in CM 1:4) and mixed with as per manufacturer instruction, finished even and smooth without using extra cement (WPC to be measured and paid separately) complete all as specified and directed. |
| 55 | M&L 10 mm thick cement plaster in CM 1:4 on fair faces of brick/ concrete block stone/ concrete including WPC as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. |
| 56 | M&L for cement plaster rendering 5mm thick in CM 1:3 on fair faces of brickwork or concrete surface as on ceilling finished even and smooth with thin layer of sagol complete all as specified and directed. |
| 57 | Supply only Integral liquid waterproofing compound of approved make (ISI marked)all as specified and directed. |
| 58 | Material & Labour for applying two or more coats of exterior emulsion weather proof paintincluding priming coat of exterior primer after applying water proofing putty of 1mm thcikness, applied over new surfaces complete all as specified and as directed. |
| 59 | M & L for preparation of new plastered surfaces of walls applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two finishing coat of oil bound distemper over a coat of primer complete all as specified and directed. |
| 60 | M & L for preparation of new plastered orunplastered surfaces of ceilingsincludingcornices, etcand applying three coatof whitewash complete allas specified and directed. |
| 61 | Complete removal of existing water proofing treatment of any description and in any position including PCC padding any thickness and cleaning, wire brushing, watering & removal of debris outside MOD land complete all as specified and directed.NOTE :-Unit rate quoted shall also include for removal of PVC water storage tank and water pipe lines wherever existing carefully and refixing at the same or other position after completion of roof repair work |
| 62 | M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed. |
| 63 | Roughening surfaces of old concrete floors by picking, sweeping clean and washing down with waters to remove dusts etc. complete all as specified and directed. |
| 64 | M&L for Brushing neat cement slurry with 3kg/sqm all as specified and directed. |
| 65 | M&L PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in concrete padding laid to required slope incl finishing the concrete surface fair and even without using extra cement complete all as specified and as directed. |
| 66 | M & L for 10 mm thick screed bed or bedding layer of mortar in cement mortar (1:4) for laying roof finish as padding finished with liquid WPC as per manufacturer instructions, complete all as specified and directed NOTE :- Integral WPC shall be measured and paid separately. |
| 67 | Apply oil bound bitumen primer @ 0.40 Litre / Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg / Litre at 25 degree Celsius on the prepared dry roof surface complete all as specified and as directed. |
| 68 | M&L APP polymeric membrane min weight 3.0kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) laid on primed surfaces by torch application method complete all as specified and directed. |
| 69 | M&L for preparation of new surfaces of any description not otherwise described over 10cm width or girth and applying two coats of solar reflective aluminium paint @ 0.10 kg/sqm of membrane surfaces complete all as specified and directed. |
| 70 | Supply and fix in repair 110mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall or laid in trenches complete all as specified and as directed. |
| 71 | S&F in repairs PVC bends 110mm borecomplete all as specified and as directed |
| 72 | Supply and fix in repair 75mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall or laid in trenches complete all as specified and as directed. |
| 73 | S&F in repairs PVC bends 75mm borecomplete all as specified and as directed |
| 74 | M&L Repair of leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damage portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed |
| 75 | M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick area of each tile not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointedin white or coloured cement to match incl 15 mm thick screed bed in cement mortar 1:4 for layingfloor finishes & dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises complete all as specified and directed. |
| 76 | M&L forceramic coloured tiles of size 350mmx250mm/ 300mm X 450mmx7 to 8 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc & dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises complete all as specified and directed. |
| 77 | Supply and fixing 15 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 78 | Supply and fixing 25 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 79 | Cutting chases pinning in making good to facing where required for concealed water tubing any size and making good with CM 1:3 cutting not exc 10cm girth in brick/stonewalls complete all as specified and directed. |
| 80 | Supply and fixing 40 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 81 | S&F Wash basin vitreous china (flat back and angle back Type) size 580x400mm excluding tap waste,chain and plug and porceline stopper but brackets including cutting for and pinning inends of brackets or erecting stand with waste pipe, fixed including taking down existing one complete as directed. |
| 82 | S&F in repair bib taps fancy typewith wall flange of make - Jaquar/ Hindware/CERA screwed down high pressure with both ends for iron pipe 15mm bore chromium plated complete all as specified and directed. |
| 83 | S&Fin repair Pillar tap cast copper alloy fancy type with capstan heads, chromium plated of make - Jaquar/ Hindware/CERA screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long shanks and nut screwed for iron pipe of 15 mm bore complete all as specified and directed. |
| 84 | S&F in repair 15 mm fancy type chromium plated stop valve / angle valve cast copper alloy of make - Jaquar/ Hindware/CERA screwed down high pressure with crutchor butter fly handlescrewed both ends for iron pipe complete all as specified and directed. |
| 85 | S&F in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kg/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed. |
| 86 | S&F in repair PVC gully/floor trap 125/110 mm dia, with stainlesss steel grating including jointing to waste pipe fixed in solvent cementall asspecified and directed. |
| 87 | S&F Jaquar Rimeless Single PieceWC with PP Soft Close slim Seat Cover, Hinges, Dual Flush Cistern Fitting, Fixing Accessories and Accessories Set, Size: 370x665x750 mm, S/P Trapand including all fittings complete fixed in repair, all as specified and as directed. (Make :- Jaquar/ Parryware/ Cera) |
| 88 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe of Make - Jaquar/ Hindware/CERA and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 89 | S&F in repairs Brass chromium plated 2-in-1 tap 15mm bore of make - Jaquar/ Hindware/CERA for fixing of health faucet and all as specified and directed. |
| 90 | S & F in repair PVC waste pipe 32 to40mm dia for WHB/Sink up to floor trap and fixed complete all as specified and directed. |
| 91 | S & F in repairs vitreous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steel chromium plated or aluminium hinging device and connecting to \"P\" or \"S\" trap incl connecting flush pipe with flushing rim complete all as specified and as directed. |
| 92 | Supply and fixing in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed. |
| 93 | S&F glass shelf 600 mm long of make - Jaquar/ Hindware/CERA and all as specified and directed. |
| 94 | S&F corner glass shelf of make - Jaquar/ Hindware/CERA and all as specified and directed. |
| 95 | S&F in Brass chromium platedtowel ring of make - Jaquar/ Hindware/CERA and all as specified and directed. |
| 96 | S&F brass chromium plated toilet paper holder Recessed type of make - Jaquar/ Hindware/CERA and all as specified and directed. |
| 97 | S&F in Brass chromium plated towel rack of make - Jaquar/ Hindware/CERA for fixing of health faucet and all as specified and directed. |
| 98 | S&F Rotational moulded polythene water storage tank of1000 Ltrs capacitycylindericalvertical with closed top including 3 Nos GI check nuts and tank nipple of 25/40mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including dismantling/ taking down of old unserviceable tank complete all as specified and directed. |
| 99 | S&F in repair Gun-metal Globe or gate valves 20 mm nominal bore dia with iron wheel head screwed both ends for iron pipes and fixed complete all as specified and as directed. |
| 100 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 600 mm all as specified and as directed |
| 101 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking up or down oldtubing complete all as specified and directed. |
| 102 | Supplying and fixing of 20mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified. |
| 103 | Supplying and fixing of 20mm outer dia CPVC brass elbow and all as specified. |
| 104 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking up or down old tubing complete all as specified and directed. |
| 105 | Supplying and fixing of 25mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified. |
| 106 | Supplying and fixing of 25mm outer dia CPVC brass elbow and all as specified. |
| 107 | S&Fin repairs table top/ counter type Wash hand basin 495x395x150mm vitreous china (white) with cantilever CI/Angle iron brackets embedded in concrete block, including long shank mixer pillar tap (Make :- Jaquar/ Parryware/ Cera) , Brass chromium plated waste coupling 32mm bore, Waste pipe PVC 32mm bore, complete all as specified and directed. |
| 108 | S&F in repairs, 10 litre capacity PVC flushing cister, syphonic action type, low level, white, with inlet, ball valve,pvc flush pipe, float and handle incl brackets and waste pipe complete all as specified and directed. |
| 109 | S&F in repair Hand Wall Mixer 3-in-1 System with Hand Shower Complete 115mm Long Bend Pipe, Connecting Legs & Wall Flange with Hand Shower 8mm Dia, 1.5 Meter Long flex tube & ABS wall hook and fixing to pipe) with Nuts. Make : Jaquar/ Hindware/CERA complete all as specified and directed . |
| 110 | S&F in repairs 15mm bore fancy type single lever Basin mixer chromium plated cast copper alloy with capstain head, long screwed shanks. Make : Jaquar/ Hindware/CERA all as specified and directed. |
| 111 | S&F in repairs brass chromium plated shower rose with or without swivel joints 150mm size of Make - Jaquar/ Hindware/ CERA and all as specified and directed. |
| 112 | S&Fin repair CP Concealed stop cock, Regular body fancy type with adjustable wall flange of make - Jaquar/ Hindware/ CERA screwed down screwedfor iron pipe15mm bore complete all as specified and as directed |
| 113 | S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm fixed in repairs complete all as specified and directed. |
| 114 | M&L Granite 18 to 20mm thick (table rubbed and polished) in steps, Jambs, Pillars, Windows, cills, platforms and like CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed. Note :(i)The Unit rate quoted is included for demolition of old Stone Slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar.(ii)Cost of rounding of stone deem to be included in unit quoted rate. |
| 115 | M & L for 75 mm thick PCC type C1, 1:3:6 (20 mm graded stone aggregate) as in plinth protectionfinishing the surface even and smooth with using extra cement, including necessary demolition of old concrete all as speecified and as directed. |
| 116 | Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed. |
| 117 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed/surface in wall/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame , concealed in wall and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 118 | All as per item No. 117 here in before but for one light point/fan/bell point controlled by one wayswitch. |
| 119 | All as per item No. 117 here in before but for one 3 pin socket outlet 5 Ampon the same board |
| 120 | All as per item No. 117 here in before but for one switch socket outlet 3 pin 5 Amps on independent board |
| 121 | All as per Sl No. 117 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. |
| 122 | Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 123 | Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 124 | Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian |
| 125 | Supply and Fix modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 126 | S & F in repair Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directedMake : Legrand/ Crabtree/ Anchor |
| 127 | S & F ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and directedMake : Anchor/Havells/L&T |
| 128 | Supply and fix White cover plate with frame,2/3 module |
| 129 | Supply and fix White cover plate with frame,4 module |
| 130 | Supply and fix White cover plate with frame,8 module |
| 131 | Supply and fix White cover plate with frame,6 module |
| 132 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length complete all as specified and directed.Make:- Havells/ Polycab/ Plaza. |
| 133 | S&F in replacementfactory madepowder coated distribution board VTPN, 6 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 134 | S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 135 | Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 136 | Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 137 | S&F in repairs 35/36 W (WH) LED Surface/recessed type2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. |
| 138 | Supply and Fixin repair and replacement ofsurface mounted Square/Roundfor LED 18W Watt downlights made of extruded Aluminium housing and high power LED light source withDriver clear diffuser with separate electronic driver with complete accessories all as specified and directed.Make : Philips/ Bajaj/ CG/Havells. |
| 139 | Suply and fix in repairs LED decorative post top lantern fitting 25 W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection completeall as specified as directed. Make: Bajaj / Philips/Halonix/ CG |
| 140 | Taking down of old unserviceable ceiling fan of any size and keep in safe custody complete all as specified and directed. |
| 141 | Refixingexisting serviceable ceiling fans 1200/1400 mm sweep servicing, painting. of ceiling fan with one coat of synthetic enamel paint by spraying including greasing/oiling, fillingcavities with filler after cleaning all dust etc. completeall as specified and as directed by Engineer-in-Charge. Note : cost includes for replacement of rubber bush ,hanging hook with new cotter pins etc complete. |
| 142 | Supply and fixing in replacement of unserviceableceiling fan 1200mm sweep, energy efficient BLDCISI mark withstar rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible copper cable 3 core of size 1.5 sqmm not less than 0.5 m long complete and writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells/Bajaj/ Orient.Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard. |
| 143 | Taking down of old unserviceable geyser and keep in safe custody complete all as specified and directed. |
| 144 | Refixingexisting serviceable geyser after servicing and cleaning all dust etc. completeall as specified and as directed |
| 145 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 146 | S&F in replacement factory madepowder coated distribution board SPN 12 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 147 | S & F MCB in repair SPN 240 volts 32 to 40 Amps suitable for \"C\" curve, 10 KA complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 148 | S&F as in repair energy efficient wallmounted LED luminaire16/18 W ,Input Supply Voltage Range: 140-270 V, Frequency :50-55 HZ supply single phase including connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting and fixing to ceiling complete all as specified and directed. Make Luker/ Philips / Havells/Bajaj |
| 149 | Supply and fiixing in repair of pressure pump of 0.5 HP of 12 Mtr head single phase50 Hz energy efficient, Star rating , 230 Volts, copper winding complete all as specified and directed. |
| 150 | Taking down of old unserviceable exhaust fan/Wall mounted fan of any size and keep in safe custody complete all as specified and directed. |
| 151 | Refixingexisting serviceable Wall mounted /Exhaust Fan of any size and sweep servicing, paintingExhaust fan with one coat of synthetic enamel paint by spraying including greasing/oiling, fillingcavities with filler after cleaning all dust etc. completeall as specified and as directed by Engineer-in-Charge. |
| 152 | Supply and fixingExhaust Fan 300 mm sweep, 230/240 volt AC single phase, PVC body,1400 RPM, suitable hold fast with necessary nut, bolts / screws with louver and writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. |
| 153 | Supply and fiixing of Wall mounted fan PVC body 400 mm sweep high speed, single phase, 50 Hz energy efficient, Star rating , 230 Volts, copper winding conforming to ISI complete with necessary connection upto ceilling rose all as directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. |
| 154 | S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 155 | S & F in repair MCB single pole 240 volts 6 to 32 Amps suitable for \"C\" curve, 10 KA complete including taking down unserviceable fitting complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian. |
| 156 | Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed.Make : Havells/ Indo asian/ Legrand |
| 157 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 2.5 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 2.5 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.Note: (a)2 runs of 2.5 Sqmm cable along with one run of 2.5 Sqmm cable for earth conductor shall be measured as one length complete all as specified and directed.Make:- Havells/ Polycab/ Plaza. |
| 158 | Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of pipelines etcinsoft/loose soil, complete all as specified and directed. |
| 159 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. |
| 160 | Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. |
| 161 | Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. |
| 162 | Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. |
| 163 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 164 | Supply only of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed. |
| 165 | Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items. |
| 166 | Supply, installation, testing and commissioning of LT panelCPRI Tested suitable for 3 phase 415 Volts of suitable size out door made out of 3.00 mm thick CRCA sheet for outdoor panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 320 Amp suitable for 415 V , 3 Phase 4 wire dust and vermine and weather proof, separate hinged door for each compartment with locking arrangement , grouted in PCC 1:2:4 type B1 complete duly powder coated with 7 tank process and comprising of the following :-INCOMING(a) MCCB four pole 25 KA, 160 A, 415 V- 02 No (b)Change over switch 160 Amp 415 V - 01 No(c)LEDindicating lampR-Y-B - 03 Nos.(d)Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 NoOUTGOING(a) MCCB four pole 10 KA, 100 A, 415 V -03 No (b) MCCB four pole 10 KA, 63 A, 415 V -01 No(c) MCB TPN 40 Amps -02 Nos (d) MCB SPN 32 A, 230 V -02 Nos(e) Provn of two Nos earth terminals. |
| 167 | S&F as in repair energy efficient wallmounted LED spike/bush type light 9 Watt with warm white with die-cast aluminium housing designed for outdoor usage and IP-65 protection. Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ supply single phase including connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting and fixing to ceiling completeall as specified as directed Make: Bajaj / Philips/Halonix/ CG |
| 168 | Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 155mm x 210 mm x 92mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. |
| 169 | M & L for drawing of PVC insulated FRLS Round Sheathed 3 core 2.5 Sqmm copper coductor , industrial cable through PVC conduit/PVC casing caping from bottom to top hole and both side connection in Junction box MCB and Street light fitting complete all as specified and directed . |
| 170 | Supply and fixing in repair building security/ LED street light fitting 35/36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG |
| 171 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global |
| 172 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 173 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 174 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 175 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 176 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 177 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 178 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 179 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 180 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 181 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 182 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 183 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 184 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 185 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 186 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 187 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 188 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 189 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 190 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 191 | M&L in repair Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mmfor each electrode pit, including taking down old u/s earth pit cover, complete all as specified and directed. |
| 192 | S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip of any description, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. |
| 193 | Note :- An amount of Rs 37,323.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail