| 1 | Taking down chowkats or frames with shutter not exc 1.5 sqm each (without taking off shutters from the frame) complete all as specified and directed. |
| 2 | All as per item No 1 but exc 1.5 sqm but n.exe 4sqm each. |
| 3 | Taking down shutter of any description n. exc 1 sqm each |
| 4 | Taking down shutter of any description exc 1 sqm but n.exec 2 sqm each. |
| 5 | All as per item No 3 but exec 2 sqm each. |
| 6 | Providing and fixing factory made uPVC white colourfixed window Area not exceeding 1.00 sqm each, made of extruded profiles with wallthickness of 2.3mm(+-0.2mm). Window profile withhollow section with multi chamber. Frame (60mm x58mm). T profile (Onevertical length in between twoshutters) (60mm x 74mm). Glazing bead (35mm x20mm) will be mitered cut and fusion welded at allcorners, including drilling of holes for fixinghardware and drainage of water etc. makingarrangement for fixing of hardware, EPDM gasket.1.2 +–0.2mm thick, galvanized steel Frame (28mm x21.5mm), T profile (27mm x 17 mrn) to be inserted inrequired profile, frame will be fixed to the wall with8mm x 100mm long fasteners- 5mm thick glazing withselected quality glass(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories.Net opening will be measured for payment purpose.) |
| 7 | Providing and fixing factory made uPVC white colourcasement (Openable) window Area exceeding 1.00 sqm but not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm) Window profile with hollow section with multichamber, frame (60mm x 58mm), sash (60mm x 73mm) T profile (One vertical length in between two shutters)(60mm x 74mm), Glazing bead (35mm x 20mm) will bemitered cut and fusion welded at all corners, includingdrilling of holes for fixing hardware and drainage ofwater etc., making arrangement for fixing of hardware.EPDM gasket 1.2 +– 0.2mm thick, galvanized steelFrame (28mm x 21.5mm), sash (31mm x 27.5mm). Tprofile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of\"zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludescost of glass and includes all other connectedaccessories. Net opening will be measured forpayment purpose.) |
| 8 | S&F for 1.25 mm thick pressed steel framesfor doors with one/more rebated incl necessary fixing lugs hinges lock strike plate etc completesize 125x60mm and filling with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in back of chowkatscomplete all as specified and directed |
| 9 | S&F for 35 mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed |
| 10 | S&F 30 mm thick flush shutters, solid core construction, with block board coreand ply wood face panels, commercial type on both sides including both faces covered with decorative face veneer with lipping / frame to match complete all as specified and directed |
| 11 | S&FFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 12 | S&F Factory Made Solid PVC Moulded Door Shutter,28 to 30 mm thick \"Stiles\" with 2, 4, or 6 raised panel design with 2 mm thick Moulded Prelam PVC sheet on the front face and 2 mm prelam PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing. |
| 13 | S&F in repair 150 mm Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed |
| 14 | S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed |
| 15 | S&Fin repair 150 mm long aluminium handles , cast type, anodised complete all as specified and directed |
| 16 | S&F 150 mm long aluminium handles , cast type, anodised complete all as specified and directed |
| 17 | S&F in repair aluminium alloy, anodised 250 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed |
| 18 | S&Faluminium alloy, anodised 250 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed |
| 19 | S&F 100mm sizebutt hinges stainless steel of AISI 304 complete all as specified and directed. |
| 20 | Taking down easing and adjusting shutters of any description exec 1 sqm but n exc 2 sqm each refixing in same opening, all as specified and as directed. |
| 21 | S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples etc complete all as specified and directed. |
| 22 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples etc complete all as specified and directed. |
| 23 | Hacking out old glass (any thickness) from any frame incl punching and drilling out old clips/pins and fixing with new one or glazed with putty or fixed with beads complete all as specified and directed. |
| 24 | M&L for sheet glass 3mm thickglass ground or obscured or frosted, on one side glazing with oil putty in square n. exec 0.5 Sqm in each pane complete all as specified and as directed. |
| 25 | M&L for tinted glass 5 mm thickin square n. exec 0.5 Sqm in each pane complete all as specified and as directed. |
| 26 | M&L for PCC (1:2:4) type B1 (using 20mm graded agg) for hold fasts finished to match with the sorrounding surfaces including necessary form work complete all as specified and as directed. |
| 27 | S&F in repair mortice lock brass 4 levers vertical type, size 100mm complete all as specified and directed. |
| 28 | S&F in repair 150 mm over all length of cover plate of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor complete all as specified and directed. |
| 29 | S&F 150 mm over all length of cover plate of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor complete all as specified and directed. |
| 30 | Supply and fixed in repair aluminium (die cast) body door closer hydraulically regulated designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. |
| 31 | S & F in repairs double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheed, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed |
| 32 | Taking down easing and adjusting aluminum shutters including complete accessories of any descriptionexc 1.5sqm but not exc 4 sqm each refixing in same opening, all as specified and as directed. Note :- Replacement of door closer, glass, lock, handle, tower bolt etc shall be measured and paid separately.Note: Taking down aluminium door and refixed after fixing floor spring including making good etc deem to be included in quoted rate. |
| 33 | S&F powder coated aluminium (minimum thickness of powder coating 50 micron) work fordoorwith chowkhat /frame made with aluminium section with size 100x44x2mm thick and shutter of vertical style with section 84x44x2mm thick and top /middle / bottom rails of shuttermade with 112x44x2mm thick over and including 5mm thick tinted glass panes, including necessary fixing arrangment ,joining cleats, glazing clips, rubber beading, floor door spring, tower bolts 200mm long, mortice lock 300 mm, 4 lever, rounded handles etc fixed to shutters complete all as specified and directed by engr in charge. |
| 34 | M&L for aluminium sliding windows with double shutter, tripple channel with 5.50mm thick tinted glass and stainless steel wiremesh with glazing clips , rubber beading and with roller, locking plate etch complete all as specified and directed. |
| 35 | Demolition of brick work or stone masonry built in cement mortar including all quoines arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all asspecified. |
| 36 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed |
| 37 | Dismantling of wall and ceiling boards any type (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets any thickness including cover fillets all as directed. |
| 38 | Supplyand fixing false ceiling at all heights with semi perforated 12mm thick micro tegular edged GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and pattern having moister content less than 2%, humidity resistant of 99%, NRCO.50 to 0.75 as per IS 8225:1987, noncombustible as per BS 476 (part 4) - 1970 and light reflectance of 85% minimum to be laid in true horizental level suspended on inter-locking metal T-Grid of hot dipped galvanised ireon section of 0.33mm thick (galvanised @120gm/Sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross T of size 15 x 32 mm of length 1200mm and secondary intermediate corss T of size 15 x 32 mm of length 600mm to from grid module of size 600x 600 mm suspended from ceiling using galvanised mild steel items (galvanised @ 80gm/Sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specifiection, drawing and as per directed of Engineer-in-Chagre. |
| 39 | Refixing only the depressed/saggedportion ofexisting false ceilinggrid system ofany descriptionafter taking down existingceiling board of any description and refixing the same in position. Note- The quoted unit rate include supply and fixing4 mm dia GI bar hanger and fly clipif required in refixing. |
| 40 | S&F 16 mm thick of size 595 x 595mm or 600 x 600 mm mineral fibre false ceiling board of pattern classic lite RH -99 (Bevelled tegular) of armstrong or equivalent make Specified including taking down old ceiling board from existing snap grid complete all as specified and directed. |
| 41 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise sepcifically provied for including existing roof treatment (tarfelt) including removing to a distance exc 1.50 KM but not exc 5.00 KM complete all as specified and directed |
| 42 | M & L for cement concrete type C1 1:3:6 (20 mm graded aggregate) in copings, plinth protectioncourses, string courses and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 43 | Hacking out old glass (any thickness) from aluminium door shutter with rubber beading / aluminium beading and refixing the same glass after the change of new rubber beading and tightening the same complete all as specified and directed. |
| 44 | Hacking out old glass (any thickness) from aluminium door shutter with rubber beading / aluminium beading and fixing new glass 5 mm thick with new rubber beading and tightening in existing door shutter complete all as specified and directed. |
| 45 | S&F in repair WPC board, 9 mm thick prelaminated on both side with decorative choice lamination and fixed with screws aluminium door panel complete all as specified and directed. |
| 46 | Dismantlingwrought iron or mild steel work of any description not otherwise described for,complete all as specified and directed. |
| 47 | M&L for Framed work as grills with end bars shoulders/framed guard bars/gas bank/gate/framing barred iron doors,ladders,framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 and similar work conforming to Fe-410 or 310 complete all as directed |
| 48 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooksand hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) andhanging; also fastening and fixing complete all as specified and as directed. |
| 49 | S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed |
| 50 | S&F 1.25 mm thick Mild steel, plain, blacksheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bendingor turning up, mitred angles, etc. as required complete all as specified and directed |
| 51 | S&F in repairSteel rolling shutters with thickness of lathe 1.25 mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete:push pull or manual type all as specified and directed. |
| 52 | M&L for servicing existing mainsteel sliding doors hangers by cleaning/oiling/ greasing bearing wheels of top and bottom of gate including cleaning rails of shutter movement complete all as specified and directed :- Note :- (a)Contractor have to make its own arrangement of prop to reach the top of hanger gate by any means and for inspection purpose. (b) Rate all inclusive of derailed hanger gate, realigned with using adequate manpower, chain pulley blocks and adequate support for shutters. |
| 53 | Preparation of new or previously untreated wooden surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel pain over a coat of pink primer complete all as specified and directed. |
| 54 | Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel pain complete all as specified and directed. |
| 55 | Dismantling asbestos cement (corrugated or semi corrugated etc) sheets incl wind ties in roof coverings complete all as specified and directed. |
| 56 | Dismantling plain or corrugated steel sheeting, any gauge or thickness at any position or similar pattern of roof covering complete all as specified and directed. |
| 57 | S & F pre-painted galvalume aluminum zinc coating 150gsm, GI based corrugated steel sheet0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 58 | S & F pre-painted galvalume aluminum zinc coating 150gsm, GI based plain steel sheet0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridge to match the existing roof coverings, fixed with self tapping screws complete all as specified and directed. |
| 59 | S & Fix in repair wind driven turbo ventilators of 600 mm size with fixing sheet. The top portionshold be made of aluminium with power coating, The shaft and varipitch should bemadeof stainless steel and aluminium respectively alongwith heavy quality ball bearing system without FRP base complete all as specified and directed by Engineer -in-Charge.Note: (i) No 100 % site for execution will be given at once to the contractor will be provided site as per requirement of site decided by Engineer in charge. (ii) The contractor will attend to execute item no. 38 with proper fitting and finishing with in 8 hours of verbal direction given by Engineer in charge orGE there will be a penalty of Rs 1500 per hour exceeding 8 hours. |
| 60 | All as per item No. 59 but with FRP corrugated base sheet |
| 61 | Closing bolt holes and water tightening of self tapping screw/J bolt in GI/Galvalume roof sheeting with using ready to use tarplastic water proofing sealent in cold application including replacement of defective tapping screw/J bolt screw comple all as specified and directed. |
| 62 | S& F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 63 | S&FSolid PVC Wall Lining/panneling on wall/ceiling consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as perrequirement and directionof Engr-in-Charge.Note: The colour and desing for wall panneling shall be approved with Garrion Engineer prior to finxing. |