| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness as in roof coverings. |
| 2 | S&F prepainted aluminium zinc steel sheet (galvalumebase) or thinknee0.50mmhaving tensile strength of 550 MPA , in colour and to be facotry moulded as in roof covering /cladding and fixed withself tapping screws /self drilling serews, to suit the roofing in customizedcolour matching with the colour of roofing and screws are to be fixed using torque adjustable electronic gun screws drills of suitable capacity complete all as specified. |
| 3 | M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws as specified. |
| 4 | Dismantling timber scantlings 40 sq. cm and over in section, in any position |
| 5 | M&L Rolled sections channel angle Tee section and in tubular sectionas in main and cross beams, hip and jack rafters; purlins,post of Fe 410- W (Gde-E-250) where connected to common rafters and running rails and embbeded in concrete complete . |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwiseprovided for. |
| 7 | M&L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 8 | M&L for two coats of synthetic enamel painting over a coat of red oxide zinc chrome primer on steel surfaces over 10cm width or girth including preparation of surface complete. |
| 9 | Demolition of brick work built in cement work complete. |
| 10 | M&L for brick work with sub class `B’ bricks, straight on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 11 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) any thickness, including cover fillets but without frame work. |
| 12 | S&F powder coated aluminium snap grid frame work for false ceiling size of grid 605 mm x 605 mm complete all as specified and directed. |
| 13 | Supply & fixing 4mm thick non asbestos E-board cememt building board for insulation and accoustic purpose, 600 x 600 mm size fixed with staples on snap grid as in ceiling complete all as specified and directed. |
| 14 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level). |
| 15 | M&L 75 mm thick PCC (1:4:8 ) type D-2 as in sub base finished even and roughcomplete all as specified and as directed. |
| 16 | M&L for Mirror polished Kota Stone slab flooring 18-20 mm thick over cement screed bed 15mm thick 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L for Kota Stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed bed 10mm thick 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge. |
| 18 | M&L for 75mm thick cement concrete 1:3:6 type C-2 using20mm graded agg as in plinth protection incl all necessary form work & finishing surface even & smooth using extra cement complete all as specified and as directed. |
| 19 | M&L for providing PCC 1:2:4 type B-0 as in roof kerbs or mud stops rouded or chamfered on edges, saucer drain (using 12.5mm graded stone aggregate) complete all as specifed and directed. |
| 20 | Taking down chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete. |
| 21 | All as per item no 20 here-in-before but exc 1.50 sqm but n.exc 4.00sqm each complete all as specified and directed. |
| 22 | Supply & fixingSteel windows with side hung shutters including box type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or weldedcomplete all as specified and directed. |
| 23 | All as per item No.22 herein before but without glazing bars complete all as specified. |
| 24 | S&F framed work such as grills,gratings, etc with ends of bars shouldered and / or riveted or forged into spikes; framed guard ; barred iron doors; ladders ; framed balusters; walk ways; railing and simillar work Con-forming to Fe 290 Gde E-165. |
| 25 | S&F Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete. |
| 26 | S&F mild steel wire cloth, 0.45 mm nominal dia of wire and average width of aperature 1.4 mm and fixed with alluminium staple and around all beading complete all as specified and as directed |
| 27 | M&L for PCC 1:3:6 type C-1(using 20mm graded stone agg) for bed block for fixing hold fast complete all as specified. |
| 28 | S&F plain framed solid, chowkhats and frames, wrought rebated on solid rounded or chamfered put together with glue pinned supplied and fixed 2nd class hard wood. |
| 29 | S&F35mm thick flush shutters, solid core construction, with block board core and plywood face panesls, commercial type on bothe sides complete all as specified and as directed. |
| 30 | M&L for 0.9mm thick decorative laminate type 1 of surface finish, colour and patters as approved, fixed with approved adhesive as per manufacturer\"s insturctions, complete all as specified. |
| 31 | S & F aluminium handle, cast type anodized 150mm size. |
| 32 | S & F 200 mm long aluminium anodized barrel tower bolts of extruded section lcomplete all as specified and as directed. |
| 33 | S&F butt hinges medium weight cold rolled mild steel of 100mm long complete all as specified and directed. |
| 34 | S&F Aluminium alloy, anodised, sliding door bolt with haps, staple (bolt type) and fixing clips with sheet, cast and extruded section and fixing bolt and sliding bolt of extuded sections or cast aluminium alloy and fixed 300 mm long complete. |
| 35 | Taking down cement plaster on brick or stone walls etc raking out joints hacking for key scrabbing down water etc complete. |
| 36 | M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete. |
| 37 | Material and labour for 15mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces using WPC where ever requiredas per manufacturerer\"s instructions and finishing the surface even and smooth (without using extra cement) etc.complete all as specified NOTE -WPC shall be measured and paid separetely. |
| 38 | Supply only WPC complete all as specified and directed. |
| 39 | M&L Preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over & including a coat of primer complete. |
| 40 | Material & Labour preparation of newly plastered surfaces of wall and applyinga layer of wall care putty 2mm thick (averaging) on wall surfaces including cornics etc for proper levelling of plaster and applying a two coats of exterior emulsion paintover a priming coat (as per manufacturers instruction) including all preparationcomplete all as specified and directed |
| 41 | M&L preparation wood Surfaces and applying two coats of synthetic enamel paint over a coat of pink primer on newly prepared wooden surfaces complete all as specified and directed. |
| 42 | M&L rubber moulded Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floor etc with greypigment cement and pigment. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match complete all as specified. |
| 43 | Taking down carefullyaluminium/copper wiring of any size (for light, fan, socket or power etc complete) including fixture and fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc and making good disturbed surfaces of wall, roof etc to match with existing surface. |
| 44 | Supply & Fixing point wiring for one light point/ fan (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS)PVC cable drawn into & including medium grade PVC conduit (not less than 20mmouter dia ) with all fittings and accessories fixed concealed(including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) andsunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washersincluding one continuous run of PVC insulated (green colour) 1.5 Sqmm multistrandedcopper conductor cable earth wire and connected to earth dolly complete all as specified and directed Note:- Wiring shall be done in colour coding as directed by Engineer in charge. |
| 45 | All as per item No.44 herein before but one socket outlet 5 Amps on the same board. |
| 46 | All as per item No.44 herein before butone 3 pin socket outlet 5 Amps independent. |
| 47 | All as per item No.44 above but with 2.5 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 5/15 Amps socket. |
| 48 | Suppy & Fixing switch piano flush type single pole, one way 5 Amp complete all as specified and directed. |
| 49 | Supply & Fixing switch piano, flush type single pole 15 Amp complete all as specified and directed. |
| 50 | Supply & Fixingsocket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed. |
| 51 | Supply & Fixing socket outlet 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed. |
| 52 | Supply & Fixing steped type electronic fan regulator flush type on the existing phenolic laminatedsheet etc. |
| 53 | S&F ceiling rose surface bakelite3 terminal with base plate. |
| 54 | Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit (ISI marked) Heavy grade, 20 mm dia (external) inclusive ofjunction/terminal boxes, all fittings and accessories fixed concealed with and including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DBincluding cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existingold sub main wiring complete all as specified.Note :1 The cost of earth wire is included in the quoated rates. 2.Two run of 4 sqmm, one run of 4 sqmm and one run of PVC conduit will be measured as one unit ie one running metre” |
| 55 | Supply and fixing LED lights fitting 1x 20W (warm/milky white as required on site), 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and life of tube light not less than 50,000 hours.completeall as specified and directed.. |
| 56 | Supply & Fixingsheet metal enclosure forSPN DBs (double door type) Single pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 57 | Supply & Fixingsheet metal enclosure forSPN DBs (double door type) Single pole and neutral 8 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 58 | Supply & Fixing 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed . |
| 59 | Supply & Fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed . |
| 60 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories (incl ceiling clamp/hook fixing in ceiling/roof with fashner/nut & bolts), 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)complete all as specified and directed by Engineer-in-Charge. |
| 61 | S & F LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size with complete all as specified and directed. |
| 62 | M&L for Earthingcomplete with galvanized sheet earthplate electrodes 60x60 cm x6.3 mm thick buried directly in ground (earth pit not less than 2. 25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm as earthing lead by means of bolts, nuts , check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and incl the earth test point of galvanized Iron/steel of size 75x75x 25mm,supplying and laying charcoal dust, common salt, PCC 1:2:4 typeB1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh,20 mm dia GI pipe light grade for wateringand connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed by Engr-in-Charge. |
| 63 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross section area 16 Sqmm 2core laid in trenches or passing through pipes/ducts and incl the disturbence surface of road making good with using PCC complete all as specified and directed. Including taking down old LT U/G Cable from trenches/protection pipe etc complete. |
| 64 | Excavation in trenches not exceeding 1.5 mtr wide, depth exceeding 1.5 mtr and getting out in hard/dense soil complete all as specified and directed by Engineer-in-charge |
| 65 | Returning, fillingincl spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed. |
| 66 | Removing excavated material (soil) not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above thestarting point complete all as specified and directed. |
| 67 | M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed.. Note :-Thickness of sand cushioning shall be measured after punning. |
| 68 | M&L for brick sub class \"B\" for protection of cable comlete all as specified and directed. |
| 69 | Supply and Fixing steel tube Light grade galvanised 50 mm bore with all fittings for protection of UG cable under road/culvert and fixing on wall with saddle, screw complete all as specified and directed. |
| 70 | S&F point wiring for one light point/ fan point controlled by one, one way switch with 1.5 sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into & including casing caping and accessories including sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth, etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed(Note:- wiring shall be done in colour coding as directed by Engineer in Charge) |
| 71 | All as per item No 70 herein before but one bell point controlled by one switch complete all as specified and directed. |
| 72 | All as per item No 70 herein before but one socket outlet 5 Amps on the same board complete all as specified and directed. |
| 73 | All as per item No 70 herein before but one socket outlet 5 Amps on independent board complete all as specified and directed. |
| 74 | All as per item No 70 herein before but wiring with 2.5 Sqmm copper wire (FRLS) PVC and 2.5 Sqmm earth wire for socket outlet 5 pin 15 amps on independent board complete all as specified and directed. |
| 75 | All as per item No 70 herein before but wiring with 4.0 Sqmm copper wire (FRLS) PVC and 4.0 Sqmm earth wire for socket outlet 5 pin 15 Amps on independent board complete all as specified and directed. |
| 76 | S&F Bell push, flush type, 5 Amp complete all as specified and directed. |
| 77 | S&F Bell AC 230 volts, 50Hz single pole complete all as specified and directed. |
| 78 | S&F sheet metal enclosure with socket plug top and MCBs Single pole and neutral enclosure 240 Volt with a two pin and earth plug and socket complete with on single pole MCB20 Amp complete inlcuding taking down unserviceable sheet metal enclosure of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed. |
| 79 | S&F sheet metal enclosure for DBs (double door type) single pole and neutral 12 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed including taking down unserviceable main switches MCB DB\"s of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed. |
| 80 | S&F sheet metal enclosure for DBs (double door type) Triple pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 415 volts fixed and concealed in wall including taking down unserviceable main switches MCB DB\"s of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed. |
| 81 | All as per item No. 80 herein before but 6 way complete all as specified and directed. |
| 82 | S&F Rigid non metallic PVC conduits external dia 20mm ISI marked exclusive of boxes (Junction/ terminal) but inclusive of all tee, bends, elbows, reducers, bell mount tube ends and fixing accessories such as couplers, lock, nuts, saddles, pipe hooks etc for existing point/ main/ sub-main wiring complete all as specified and directed. |
| 83 | S&F 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 32Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 84 | M&L for sub main wiring with 2 run of 2.5 sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in PVC casping caping (ISI marked) Heavy grade inclusive of junction/ terminal boxes, all fittings and accessories fixed and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified and directed.Note: 1. The cost of earth wire is included in the quoted rates.2. Three run of 2.5 Sqmm and one run of PVC conduit will be measured as one unit i.e. one running metre |
| 85 | All as per item No. 84 herein before but 2 x 4 Sqmm inclusive 4 Sqmm earth wire complete all as specified and directed. |
| 86 | All as per item No 84 herein before but 2 x 6 Sqmm inclusive 6 sqmm earth wire complete all as specified and directed. |
| 87 | S&F LED light fitting mirror type with high out put diffuser 2 Feet, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper cable of suitable size complete all as specified and directed. |
| 88 | S&F LED lights T-5 fitting 1 x 20W (warm/ milky white as required on site), 220V, AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose 1.5 RM and life of tube light not less than 50,000 hours complete all as specified and directed.Make Havells/ Phillips/ Bajaj/ C&SNote :- LED tube light shall be purchased to get minimum 2 years warranty of material from manufacturer. |
| 89 | M&L for taking down ceiling fans/ wall mounted fans of any size/ sweep after disconnecting the wire from existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray maching including filetr after cleaning dust, taking out burnt/ damaged winding, bushes & cleaning of stator and rotor incl etc. Rewinding with 26/27 SWG of enamelled copper winding wire replacement of bearing/ bushes, condencer 2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexible core twin core not less than 1.5 meter in length and make the fan operational with a guarantee period of one year after installing the repair fan complete all as specified and directed. |
| 90 | M&L panel box concealed in wall, double door type with die cast type made all of 18 gauge CRCA sheet of suitable size for fixing of KWH meters MCCB, MCB, Bus bars etc as per IE rules comprising of following and necessary wiring for MCBs, meters-05 Nos. with Locking arrangements and optical glass over the electronic meter complete all as specified and directed.(a)S&F MCCB 100 Amps 415 volt, TPN, 25KA-01 No(b)S&F MCB SPN 63 Amps - 5 Nos(c)Space and Mounting brackets for fixing of 5 Nos single phase KWH meters.(d)Fixing only the existing electronic meter as per existing Ser No. of Qtr. |
| 91 | M&L for earthing complete with galvanized sheet earth plate electrodes 600 x 600 x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 and including excavation and earth work, GI pipe light grade 15mm bore for protection of GI wire from earth electrode to and incl the earth test point of galvanized Iron/ Steel of size 75 x 75 x 25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia GI pipe light grade for watering and connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed by Engr-in-Charge. |
| 92 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross section area 35 Sqmm 3.5 core laid in trenches or passing through pipes/ ducts and incl the disturbance surface of road making good with using PCC complete all as specified and directed. Including taking down old LT U/G cable from trenches/ protection pipe etc complete all as specified and directed. |