| Sl. No. | Item Description |
| 1 | Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | Demolition oftiles of any description or thickness in floors, aprons etc laid, bedded and pointed in mortar complete all as specified and directed. |
| 3 | Dismantling timber scantlings unframed work 40 sqcm and over in section in any position complete all as specified and as directed. |
| 4 | M&L for second class hardwood as in scantlings clean sawn timberfixed withcomplete all as specified and as directed. |
| 5 | M&L for plain fillets, square, rectangular or triangular in section clean sawn, secured with nails made out of 2nd class hard wood exc 13and n.exc 25 sqcm complete all as specified and as directed. |
| 6 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillars ,etc complete all as specified and as directed. |
| 7 | M&L brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and as directed. |
| 8 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified with and including dismantling of old Plain or corrugated steel sheeting, any gauge, thickness, including Nainital orsimilarpattern roof coverings complete all as specified and as directed. |
| 9 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecified with and including dismantling of old Plain or corrugated steel sheeting, any gauge, thickness, including Nainital orsimilarpattern roof coverings complete all as specified and as directed. |
| 10 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 11 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecifiedcomplete all as specified and as directed. |
| 12 | M&L for 15mm thick plastering in CM (1:4) on one side of lathing in two separate layers without using extra cement but using water proofing compound @ 3% by wt of cement for finished even and smooth including demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing with and including GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and as directed. |
| 13 | M&L for rendering 12 mm thick in CM (1:6) on other side of lathing finished even and smooth without using extra cement complete all as specified and as directed. |
| 14 | S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengthsi.e. within 20mm of the length indicated) confirming Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. |
| 15 | S & F Plates (plain or chequered) channels,squarecutor notched (ordinaryand countersunk) forming holes, without any attachment conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. |
| 16 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm,in floors laid over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed. |
| 17 | All as per Item No 16.00 (here-in-before) but on vertical surfaces such as skirting , dado, risers to stepsover and including 10 mm thick backing coat in Cement Mortar 1:4. |
| 18 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm,in floors laid over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed. |
| 19 | M&L for Glazed ceramic coloured tiles in vertical surface 300 mm X 200 mm / 350 x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tileover and including baking coat of 10 mm thick in Cement Mortar (1:4),complete all as specified and as directed. |
| 20 | M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm,in floors laid over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed. |
| 21 | M & L for PCC 25 mm thick type B-0, (1:2:4) (using 12.5 mm graded stone aggregate)as in levelling course of floor complete all as specified and as directed. |
| 22 | M&L for 75 mm thick PCC (1:3:6) type C-2 , (using 40 mm graded stone aggregate) as in plinth protection laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide that area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and as directed. |
| 23 | S & F for4 mm thick of size 600x600mmHSPC (high pressure Steam Cured) non asbestos fibre cement reinforced multipurpose board, pre-painted self embossed, textured designer boardE-Board Classic fixed or laid/inserted to timber/ GI frame work with screws to be fixed in ceiling flat or sloping and Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre both ways, size of grid 605 x 605mm fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any sizeincluding dismantling of old unsv ceiling boards (fibre, pulp, insulation, etc.) any thickness including cover fillets of any description and at any location complete all as specified and as directed. |
| 24 | Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. |
| 25 | Taking down chowkhat or frames exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. |
| 26 | M&L for 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pined joints complete all as specified and directed. |
| 27 | S&F 35 mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 28 | M&L for 30mm thick factory made 2nd class hard woodGlazed and skeleton window and ventilator shutter, open rebated and prepared to receive glass, gauge etc. divided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified. |
| 29 | S&F in repairsgalvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed. |
| 30 | S&F anodised aluminium powder coatedsection as in aluminium frame for doors, windows, ventilators including shutters,with one or more rebates including joining cleat for fixing complete all as specified and as directed.Note:- Necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc are deemed to be included in quoted rates. |
| 31 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 32 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, as per specification complete all as specified and as directed. |
| 33 | S&F Factory made solid panel PVC doorshutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined to-gether with solvent cement as per specification complete all as specified and as directed. |
| 34 | S&F butt hinges medium grade cold rolled mild steel and fixed size of hinges 100 mm long size complete all as specified and as directed. |
| 35 | S&F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long complete all as specified and as directed. |
| 36 | S&F Aluminium handle cast type anodised 150 mm long complete all as specified and as directed. |
| 37 | S&F Aluminium alloy anodised sliding door bolt with hasp and staple (bolt type fixing clips of sheet cast or extruxded section(300 mm long) complete all as specified and as directed. |
| 38 | S&F in repair 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed. |
| 39 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and as directed. |
| 40 | M&L for Rendering 15 mm thick in CM (1:6) on fair face of brick-work or concrete surface to be finished even and smooth without using extra cement complete all as specified and as directed. |
| 41 | M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and directed. |
| 42 | M&L for applying two coats of oil bound distemper over a coat of primer over a coat of 2mm thick wall care putty(in two layers) on newly plastered surfaces of walls including preparation of newsurface complete all as specified and as directed. |
| 43 | M&L for preparation of new plastered surfaces and applying two coats ofcement base paint over a coat of primer of approved shade on walls complete all as specified and as directed. |
| 44 | M&Lforcomplete removal of existing treatement on old plastered surface of wall & applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed. |
| 45 | M&Lforcomplete removal of existing treatement on old plastered surface of wall & applying two coats of cement based paint over a coat of primer complete all as specified and as directed. |
| 46 | M&L for preparation of oldsurfaces of wood and wood based surfaces of any description over 10 cm width or girth not otherwise described andapplying one coat of synthetic enamel paint complete all as specified and as directed. |
| 47 | M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink wood primer complete all as specified and directed. |
| 48 | M&L for preparation of newsurfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying two coats of synthetic enamel paint over a coat of red oxide primer on new surfaces in any tint complete all as specified. |
| 49 | M&L for preparation of old surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying one coat of synthetic enamel paintin any tint complete all as specified. |
| 50 | S&F in repairs tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 15 mm bore complete all as specified and as directed. |
| 51 | All as per Serial Item No 50.00 (here-in-before) but fixing only complete all as specified and directed. |
| 52 | S&F in repairs tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 20 mm bore complete all as specified and as directed. |
| 53 | All as per Serial Item No 52.00 (here-in-before) but fixing only complete all as specified and directed. |
| 54 | S&F PVC valveless, syphonic action type, flushing cistern, low level,white, with inlet, ball valve, float and handle including brackets and flush pipe complete all as specified and as directed. |
| 55 | S&FVitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and including EWC Seat cover complete all as specified and as directed. |
| 56 | Supply only flush pipe of polyethylene of low or high density of PVC 32mm dia for low level cistern complete all as specified and as directed. |
| 57 | S&F in repairs CP Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and as directed. |
| 58 | S& Fcast iron P or S trap of 100mm diacomplete all as specified and as directed. |
| 59 | S&F in repairs forbib tap cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrulesuitable for 15 mm dia bore pipe and fixed as approved by complete all as specified and as directed. |
| 60 | S&F in repairs Stainless steel soap dish white of size 160 x 160 x 90 mm as approved fixed with brass screws or embedded in wall completeall as specified and as directed. |
| 61 | S&F in repairs 600mm long tubular tower rail brass chromium plated 20mm dia, D type ,fixed with two plugs (Gutties) of 2nd class hard wood embeded in cement mortor 1:3 with MS screws completeall as specified and as directed. |
| 62 | S& F in repairs600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers completeall as specified and as directed. |
| 63 | S&F in repairs CP toilet paper holdercompleteall as specified and as directed. |
| 64 | S&F in repairs corner glass shelf assembly 250mm radius made of 6mm thick craaylic glass, with CP railing, fixed with suitable rowal plug & screws complete all as specified and as directed. |
| 65 | S&F in repairs vitreous china wash basin, size 550 x 400mm white including brackets, and waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and as directed. |
| 66 | S & FPVC (SWR) Bend with any radius of 110 mm dia complete all as specified and as directed. |
| 67 | S & FPVC (SWR) Bend with access door any radious of 75 mm dia complete all as specified and as directed. |
| 68 | M&L for cement concrete type C-2 (1:2:4) (using 20 mm graded stone agg) as in surface channels and drains complete all as specified and as directed. |
| 69 | M&L for chequered cement concrete tiles of size not less than 300x300x25mm thick laid over and including 15mm thick screed bedfor laying floor finishes in cement mortar (1:6) etc, set, jointed and pointed in neat cement slurry with grey cement and pigments complete all as specified and directed. |
| 70 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms mouldscomplete all as specified and as directed. |
| 71 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to GDE Fe 410-W(Gde-E-250) quality-A complete all as specified and as directed. |
| 72 | M&L for vitreous china squatting pan, Orissa, pattern size 580 x 440 mm white with integral foot rests(excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage pipe etc complete including making good to floor complete all as per specified and as directed. |
| 73 | S&Fsteelworkintubulartrusses, post, purlinsincludingspecialshapedwasheretc.CompleteusingERWorinductionbuttweldedtubesconformingtoIS1161-1979gradest-240complete all as specified and as directed. |
| 74 | S&F in repairsfor Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and ringscomplete all as specified and as directed. |
| 75 | Surface excavation n.exc 15cm deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 76 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified ans as directed. |
| 77 | Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified ans as directed. |
| 78 | Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed. |
| 79 | M & L for RCC design mix(M-25) as in foundations, including rafts, footings, foundation beams, Plinth beams, bases for columns etc , basement slabs , under reamed piles and mass concrete design mix complete all as specified and as directed. |
| 80 | M & L for RCC design mix(M-25)as in columns, pillars, piers, posts and strutscomplete all as specified and as directed. |
| 81 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 82 | Use and waste of formwork to sides of pillars posts, struts, piers, columns and stanchions finished the suface rough. |
| 83 | M&L for brick work with sub class `B\" bricks(using old size burnt bricks) straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed. |
| 84 | M&L for Rendering 15 mm thik in CM (1:6) on other than fair face of brick-work or concrete surface to be finished even and smooth without using extra cement complete all as specified and as directed. |
| 85 | M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete workusing water proofing compound @ 3% by weight of cement , finished even and smooth without using extra cement complete all as specified and directed. Note:-WPC will be measured and paid separately. |
| 86 | Supply only integral water proofing compound etc complete all as specified and directed. |
| 87 | M&L for PCC (1:4:8) type D-2, 75 mm thick (using 40 mm graded stone aggregate) as in sub base of floor complete all as specified and as directed by the Engineer-in-Charge. |
| 88 | M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E 250) quality-A of size equal angle 40x40 mm of 5mm thk 3.4 kg /mtr complete all as specified and as directed |
| 89 | S&F framed work such as grills,grating, etc, with ends of bars shouldered and/or riveted or forged into spikes ;framed gurad bars ; barred iron doors, ladders, framed balusters, walk ways, railings frame work of water tanks and similar work conforming to Fe-290-0 or Fe-165 include riveting and welding as directed and fixing with screws ,bolts, complete all as specified and as directed. |
| 90 | S & F forNonasbestos fibre cement building boards4mm thickfixed with screws in ceiling over and including anodised aluminium snap grid frame work for false ceiling complete all as specified complet fixing arrangement complete all as specified and as directed. |
| 91 | M&L for Granite (of any type) tiles 18-20mm as in platform thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigmentto match the shade of granite stone including grinding and polishing with nosing laid over and including 10 mm screed bed in CM 1:4 complete all as specified and as directed. |
| 92 | S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty or in rubber beading with one way film in squareexc 0.5 sq. m in each pane complete all as specified and as directed. |
| 93 | Use and waste of formwork for lintel beam flat rough finished surface complete all as specified and as directed. |
| 94 | Use and waste of formwork to chajjas, troughts and similar items including edges complete all as specified and directed. |
| 95 | Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 96 | M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 97 | All as per Ser item No 96.00 (here-in-before) but 6mm to 8mm dia as in stirrups/binders. |
| 98 | M&L for RCC design mix M-25, as in beams, cantilvers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 99 | M&L for RCC design mix M-25, as in fins, chajja etc complete all as specified and as directed. |
| 100 | M&L for PCC (1:4:8) type D-2 (using 40mm graded stone agg) as in foundation, filling and mass concrete complete all as specified and directed. |
| 101 | M&L 40 mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded stone agg) as damp proof course to horizontal or vertical surfaces including necessary form works, applying evenly a coat of blown type bitumen at 1.50 kg per sqm and blinding with clean dry sand @ 0.05 cum per sqm including 150 micron thick polythene film laid on a coat of bitumen primer @ 0.30 to 0.50 kg per sqm complete all as specified and as directed. |
| 102 | M&L for hardcore (broken stone/boulders) of gauge exc 63mm but n.exc 100mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface etc complete all as specified & directed by Engr-in-Charge. |
| 103 | M&L forsand filling under floor or foundation including watering and ramming complete all as specified ans as directed. |
| 104 | M&L for PCC (1:4:8) type D-2, 75 mm thick (using 40 mm graded stone aggregate) as in sub base finished even and rough complete all as specified and as directed by the Engineer-in-Charge. |
| 105 | M&L 25 mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in subbase of flooring finished even and fair using extra cement complete all as specified and as directed. |
| 106 | S&F15 mm bore GI tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors complete all as specified and as directed. |
| 107 | S&F 20 mm bore GI tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors complete all as specified and as directed. |
| 108 | S&FHealth faucet of CP 15mm bore fancy type with suitable flexible pipe including CP nipple with socket complete all specified and as directed.Make:ESSCO cat No ALE-ESS-585 or equivalent in Hindware/Cera |
| 109 | M&L for cutting chases, pinning in, making good to facing where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth complete all as specified and directed. |
| 110 | S&F vitreous china wash basin, size 550 x 400mm white including brackets, and waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and as directed. |
| 111 | S&FVitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and including EWC Seat cover complete all as specified and as directed. |
| 112 | S & F in repairs vitreous china bowl urinal flat back size of 465x355x265 mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed. |
| 113 | S&F PVC valveless, syphonic action type, flushing cistern, low level,white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. |
| 114 | S&F15mm dia of pipe bib tap cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed as approved by complete all as specified and as directed. |
| 115 | S& F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 116 | S&F in repairs for 15mm dia of pipe angle stopvalves,fancy type and chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixedcomplete all as specified and as directed. |
| 117 | S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed |
| 118 | S & F Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated brackets guard and railing 60 cm long complete all as specified and as directed. |
| 119 | S&F towel rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (min wt - 170 gms) complete all as specified and as directed. |
| 120 | S&F110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/under floor complete all as specified and as directed. |
| 121 | S&F in repair 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/under floor complete all as specified and as directed. |
| 122 | M&L for Point wiring in repairs complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable1100 volts grade with multi-stranded copper conductors, drawn throughand including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc as required at site and 50 mm deep complete all as specified and as directed. |
| 123 | Onelight pointcontrolled by one, one way switch . |
| 124 | One Exh/Ceiling fan point controlled by one, one wayswitch. |
| 125 | One 3 pin socket outlet 5 Amps on the same board with other switches. |
| 126 | One 3 pin socket outlet 5 Amps on the Independent board. |
| 127 | All as per item No-122.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. |
| 128 | S&F Switch piano flush type single pole, one way 5Acomplete all as specified and as directed. |
| 129 | S&F Socket outlet, 2 in 1, 5 pin 5A flush type complete all as specified and as directed. |
| 130 | S&F Switch Socket combination, 2 in 1, 5 pin 6A flush type complete all as specified and as directed. |
| 131 | S&F Switch Socket combination, 2 in 1, 5 pin 6A/16A flush type complete all as specified and as directed. |
| 132 | S&F stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 133 | S&F ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and directed. |
| 134 | Material and labour for point wiring , concealed on wall or ceiling for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for earth continuitywire connected to common earth dolly drawn through and including PVC rigid conduit of adequate sizewith all accessories and the cables will terminate to modular GI box of suitable size and thickness includingModular typeBase / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc.complete all as specified and as directed. (Note: (i) Red, Yellow and Blue coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) payment for cutting chases shall deemed to be included in the quoted rate.) |
| 135 | Onelight/Exhaust pointcontrolled by one, one way switch . |
| 136 | One 3 pin socket outlet 5 Amps on the Independent board. |
| 137 | All as per item No- 130.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. |
| 138 | S&F Modular Switch 1 way 6A,1 module complete all as specified and as directed. |
| 139 | S&F Modular Socket ,6A/2/3 pin combined 2 module complete all as specified and as directed. |
| 140 | S&F modular switch 1 way 16A, 1 module complete all as specified and as directed. |
| 141 | S&F Modular Socket ,6A/16A-2/3 pin combined 2 module complete all as specified and as directed. |
| 142 | M&L for sub main wiring with two runs of4 Sq mm and one run of 4 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping including taking down old unsv one complete all as specified and as directed. NOTE:- two runs of 4 Sq mm + one run of 4sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length . |
| 143 | S&F in repairs LED Light fitting 1 x 20 watt (4 Ft), Wall/ Surface mounted, intergrated type with all accessories internally prewired and incl connecting up with, including two Nos PVC blocks and connecting upwith flexible copper cable of size 0.75 Sq mm 3 core and flexible pipe from ceiling rose to the light fittingcomplete all as specified and as directed. |
| 144 | All as per item No 137.00 above but10 wattLED, 2\" batten, Wall mountedwith polycarbonate housing/ batten. |
| 145 | S&F and testing in repairs/replacement of LED Bldg Security light fitting of capacity 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 1.2 mtr GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling of holes as reqd and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to the light fitting and all as specified and directed by Engr-in-Charge. |
| 146 | S&F in repairs/replacement for Decorative wall mounted light fitting made up of polycarbonate including 9 watt LED lamp with B-22 base complete all as specified and as directed. |
| 147 | S&F in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling and connecting up with driver, three core flexible copper conductor of suitable size complete all as specified and as directed. |
| 148 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 149 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed. |
| 150 | S&F in repairs MCB Distribution board double door type SPN 12 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacitycomplete all as specified and as directed. |
| 151 | S&F in repairs MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. |
| 152 | S&F in repairs MCB Distribution board double door type SPN 4 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. |
| 153 | S&F in repairs MCB SPN 32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB \"C\" seriescomplete all as specified and as directed. |
| 154 | S&F in repairs MCB SP 5-40 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB \"C\" seriescomplete all as specified and as directed. |
| 155 | Taking down carefully exisiting water heater storage 25 Ltrs Capacity, PVC connection GI Tubes, Bip taps, and stop valve safecustody and refixing, testing after compltion of the work complete all as specified and as directed. Note : All fansterns Nut and Bolts deemed to be included in quoted rate. |
| 156 | M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 2 core including taking down/up old unsv one complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. |
| 157 | M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 10 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.Make : Richa/Finolex/Polycab |
| 158 | M&L for spread fine river sand in trenches complete all as specified and as directed. NOTE: Punned down thickness shall only be measured and paid. |
| 159 | M&L for laying brick sub class \"B\" old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed |
| 160 | Material & labour for cutting/ digging of existing Hard surface of cement concrete/Bituminous road of size not less than 45 cm in width and 20 cm deep for laying of LT cable& making good to the disturbed surfaces by providing PCC or same material after laying of pipe line and returning filling of soil complete all as specified and as directed. |
| 161 | Supply & laying tubes \" light grade\" galvanised, with all fittings, fixed complete to walls, poles, ceilings for protection of cables of size 40 mm dia bore including taking out unsv GI tubing complete all as specified and as directed. |
| 162 | M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. NOTE:- (i)The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 chamber, CI frame with CI coverfunnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 441 of MES SSRPart-II. (ii)Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail