| 1 | Excavation in trenches n exc 1.5 m wide and n.exc 1.5 m in depth for foundation of pole/stay and laying of UG cable/GI pipe etc and getting out in any type of soil complete all as specified and directed. |
| 2 | M&L returning, filling and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified anddirected. |
| 3 | Removing excavated material nexc 50m and depositing where directed at a level nexc 1.5mtr above the starting point complete all as specified anddirected. |
| 4 | Surface excavation not exc 30cm deep and averaging 15cm deep and gettingout in any type of soil complete all as specified anddirected. |
| 5 | M&L Cement concrete M-7.5 (Nominal mix),type D-2, 1:4:8, (using 40 mm graded crushed stone aggregates) in foundation filling and mass concrete, post holes, sub base of floor etc complete all as specified and directed. |
| 6 | M&LReinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases of columns etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 7 | M&LReinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in slabs, supported on walls, beam and columns in floors and in shelves and the like complete all as specified and directed. |
| 8 | M&LReinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 9 | M&LReinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in beams, chajja, cantilevers, bressummers, lintels over 1.5 mtr span complete all as specified and directed. |
| 10 | M&LReinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in chajja, etc complete all as specified and directed. |
| 11 | Steel Formworkto sides of concrete foundations,footings, bases of columns, raft and raft beams, sides and sofits of foundation and plinth beams and similar works; vertical or to batter for rough finished flat surfaces complete all as specified and directed. |
| 12 | Steel Form work to sides and soffits of floor/roof beam for rough finished flat surfaces of concrete complete all as specified and directed. |
| 13 | Steel Form work to sides of pillars, posts, struts, piers, columns and stanchionsfor rough finished flat surfaces of concrete complete all as specified and directed |
| 14 | Steel Form work to soffits of suspended slabs such as roof slabs, floor slabs etc not exceeding 200mm thick complete all as specified and directed. |
| 15 | Steel Formwork to chullah hoods, chajjas, troughs and similar items including edges finished as fair finish surfacecomplete all as specified and directed. |
| 16 | Steel form work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roof and not exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc.10cm but n.exc. 20cm wide for fair finished surfaces of concrete, complete all as specified and directed. |
| 17 | M&L TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally forhooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 18 | All as per item Nohere-in-before but 8mm dia and over upto and including 10mm diaas in stirrups, spacers, binders complete all as specified and directed. |
| 19 | M&L for Pressed steel cup board frameof MS sheet 1.25 mm thick size of frame 60 x 40 mm with rebateincluding necessary lugs,hinges,lock strike plate etc including PCC 1:2:4 as in filling to back of frame including Complete all as specified and directed. |
| 20 | S&F for 18-20mm thickPVC100% termite/water proof, fire retrandent eco friendly weight not lessthan 8 kg/sqm PVCsoild board one side decorative choice laminate and other side balancing white as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work etccomplete all as specified andas directed. |
| 21 | S & F hasp & staple safety type aluminium anodised with mild steel hinges Spin including bolt to hinges plate fixed with screws of 75 mm in length complete all as specified and directed. |
| 22 | S&F in repair 30/40 mm flaps width continuous (paino) hingesmild steel brass bright finished or electrogalvanised complete all as specified and directed. |
| 23 | M&L forsteel fancy handle 150 mm size for kitchen cabnet complete all as specified and as per sample kept in GE office. Make:-Hettich,Godrej, Harrison. |
| 24 | S&F in repair for Magnetic catcher for cupbord complete all as specified and directd. Make:-Hettich,Godrej, Harrison . |
| 25 | Providing & fixing Windows/ ventilators fabricated from roll framed sections made of galvanized steel colour coated/ powder coated (Base steel as per IS 513 “D” quality galvanized as per IS 277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.60mm incl painting, with Frame section 72mm x 55mm, Mullion section 72mm x 50mm, Shutter Frame 47mm x 20mm, incl 5mm plain/figured float glass and wire mesh,handle, lock and other accessories with powder coated guard bars Grill of size 10mm sq. MS Bars and 6mm x 12mmMS flat fixed using fasteners etc complete all as specified and as directed. Make:ECO – 4000 Series Windows (Double Rebate) NCL Windoors, Tata, JSW or its equivalent. |
| 26 | Materialand labour for plain cement concretetypeB-1 1:2:4 (20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles andthroating, complete all as specified and directed. |
| 27 | M&L for roof treatment with the following specification - applying oil bound bitumen primer @ 0.20 Kg/sqm and providing 3mm thick APP modified water proofing membrane weighing not less than 3 Kg/sqm reinforced with non-woven polyester matt weighing not less than 160 gm/sqm, The overlap shall be minimum 100mm on transverse direction and 100 mm on longitudinal direction and sealing overlap by torch application and bonded and applying a coat of blown grade hot bitumen 85/25 over and below the membrane @ 1.20 Kg/sqm in drying over the membrane finished with solar reflective bituminous aluminium paint/ primer @ 0.10 Kg/sqm over RCC roof slab/ parapet after cleaning the surfaces by removing dust, dirt etc. as per manufacturer’s instructions including 20 mm thick screed in CM 1:4 with WPCand all as specified and as directed.NOTE :- The work shall be executed at site by the authorised applicator of APP and as approved by the GE. |
| 28 | M&L for Writing letters or figures (Block, Roman. Italic or Indian) n.exc 30cm high of any description n.exc 0.2 Sqm with paint as per direction of Engr-in-chargeSuch as NP-02,P-101,T-104 complete all as specified anddirected. |
| 29 | M&L for 50 mm thick PCC type B-1, 1:2:4 (20mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 30 | Spreading and levelling of earth in layers n exc. 25 cm thick and well ramming including watering the samecomplete all as specified and directed. |
| 31 | M&L for 100 mm thick PCC type C-2, 1:3:6 (40mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 32 | M&L machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS-15658-2006 of 80 mm thickness, M-40 grade with grey cement and pigment over and including 50mm thick layer of sand filling complete all as specified and directed. |
| 33 | M&L Hardcore of broken stone or bouldersof gauge n. exc. 63mm, deposited spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surfacecomplete all as specified and directed. |
| 34 | M&L 16 to 18mm thick Granite (of any type)work (table rubbed and polished) in steps ( tread/ riser) in single piece , jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over 15 mm thick CM 1:4 complete all as specified anddirected . |
| 35 | M&L Epoxy Polyurethane Coating (EPU) Supplying and applying ESD Ployurethane Flooring System as per the following Specification:- (a) Surface preparation: preparing the existing surface of floor by using proper scarification eqpt and cleaning by wire brushing & blow etc, to remove all dirt, dust, oil etc to expose clean sound base concrete. Cost shall include any imperfections in the concrete shall be treated with suitable repair system as per manufacturer specification. Note:-(b) Primer: Supply and application of moisture insenstive solvent free epoxy bonding primer over the prepared surface (Floor/coving) in a thin continuous film and work the Primer into the surface using a stiff brush or roller. Apply second priming coat on identified light colored dry patches over first coat. (c) Base Coat/Scratch Coat : Supply and application of 1mm thick base layer with cementitious Polyurethane of self smoothing self levelling epoxy underlay spread evenly to maintain the thickness using a serrated trowel followed by spike roller, rolled over the levelled underlay to remove any entrapped air all as per manufacturer instructions and as specified. (d) Anti Static grid : Supply and fix copper earth strip of size 25mm wide and 80 micron thick, fixed over the floor area along the perimeter and internally with a grid size of min 3mx 3m and max 5m between strips. The Surface shall be treated with aqueous anti static epoxy system, conductive under coat spread as specified and as manufacturer\"s instructions. The conductivity of the under coat shall be 2 x10^3 ohms - 4x 10^3 ohms. The entire system to be connected to earth pit AND testing complete. (e) Epoxy Polyurethane Coating (EPU): Providing 3 mm thick epoxy polyurethene ESD flooring, having 28 days compressive strenght as per ASTM C 109 45MPa, Flexural strenght will be 12 MPa as per BS 6319-3, Tensile strength will be 4MPa as per BS 6319-7, having surface of earth resistance < 1 x 160 Ohms. The fire resistivity of the material has to be of class 2 as per BS 476-7. |
| 36 | (d) Anti Static grid : Supply and fix copper earth strip of size 25mm wide and 80 micron thick, fixed over the floor area along the perimeter and internally with a grid size of min 3mx 3m and max 5m between strips. The Surface shall be treated with aqueous anti static epoxy system, conductive under coat spread as specified and as manufacturer\"s instructions. The conductivity of the under coat shall be 2 x10^3 ohms - 4x 10^3 ohms. The entire system to be connected to earth pit AND testing complete. (e) Epoxy Polyurethane Coating (EPU): Providing 3 mm thick epoxy polyurethene ESD flooring, having 28 days compressive strenght as per ASTM C 109 45MPa, Flexural strenght will be 12 MPa as per BS 6319-3, Tensile strength will be 4MPa as per BS 6319-7, having surface of earth resistance < 1 x 160 Ohms. The fire resistivity of the material has to be of class 2 as per BS 476-7. (f) Any crack/damaged surface of concrete shall be repair by chemical as per manufacture instruction before laying PU. |
| 37 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4. Complete all as specified and directed. |
| 38 | M&L Brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:6 incl complete all as specified and directed |
| 39 | M&L Brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4complete all as specified and directed |
| 40 | M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or conrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed |
| 41 | M&L for Rendering 5mm thick in cement mortar 1:3 on ceiling fair faces of brick work or conrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed |
| 42 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or conrete surfaces finishing the surface even and smooth without using extra cement mixed with liquid water proofing compound @ 3% of cement weightcomplete all as specified and directed. (WPC shall be measured and paid seperately as supplied only). |
| 43 | M&L 75 mm thick PCC, type C-2, 1:3:6, (using 40mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without nusing extra cement complete all as specified and directed |
| 44 | M&L forpreperation of plastered surfaceand applying three coats of white wash on wallcomplete all as specified and directed |
| 45 | M&L forpreperation of plastered surfaceand applying three coats of white wash on ceilingcomplete all as specified and directed |
| 46 | Preparation of new plastered surfaces of walls, chajjas, fascia, face of columns, beams etc. andapplyingtwo coat of weather proof exterior emulsion paint (APEX) of Alkali & fungal resistance, dirt resistance qualities in same shade and color as approved over a coat of primer using smart periodical techniques etc (up to 2nd storey with necessary scaffolding) complete all as specified and directed. |
| 47 | M & L for5 mm thick tinted glass Panes of any colour including with rubber gasket and beading /Glazing clip size complete all as specified and directed |
| 48 | Supply only liquid Water Proofing Compound. complete all as specified and directed |
| 49 | M&L Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat forfixing etc complete all asspecified anddirected |
| 50 | M&L for sliding anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed. |
| 51 | S&F for Brass Mortice4-lever lock for Aluminium doors with fittings, concelead type, size 100 mm including complete accessories complete all as specified and directed. |
| 52 | Supply and layingfor XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade,of size 35 Sqmm, 3.50 corecomplete all as specified and directed. Note : Earth work including excavation, returning filling, removing, sand cushioning, GI pipe,brick covering for mechanical protection of cable etc will be measured and paid for separately under respective items of schedule. |
| 53 | Supply & laying of approved quality sand under cable upto 15cm before laying the cable and 8cm over the cable after laying, punned down to overall thickness of 18cm in trenches for cable cushioning complete all as specified and directed.(Punned thickness shall be measured) |
| 54 | Material and labourforwell burnt, old size Sub Class\"B\"brickcovering protectionto the eletric cablelaiddry flat transversallyalongthe lengthof cable with widthequal to lengthof brickcomplete all as specified and directed. |
| 55 | Point wiring with 1.5 Sqmm FRLS, PVC insulated andunsheathed multi stranded flexible copper conductor cable inand incl rigid PVC conduitconcealed medium grade with pressed mild steel terminal boxes(sheet not less than 1.6 mm thick) duly painted with a coat of red oxide primerwith suitable thickness plastic laminated sheet cover 3mm thickofadequate size for one light or one fancontrolledby one switch incl 1.5 Sqmm FRLS, PVC insulated andunsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed. Note: a) Rate for cutting chases for conduits and sinking for boxes and making good to wall, floors deemed to be included in each point etc (b) On RCC roof ceiling PVC conduit shall be provided on surfaces for any necessary point with proper fixing clips and no extra cost shall be paid for the job etccomplete all as per specified and directed. (c) colour coding is to be maintained. (Ph-Red, N-Block, Half-yellow, Earth-Green). |
| 56 | All as per item No 83 but for one 3 pin 5 Amp socket outlet on independent board complete all as per specified and directed. |
| 57 | All as per item No 83 but for one 3 pin 5 Amp socket outlet on same board complete all as per specified and directed. |
| 58 | Point wiring with 2.5 sqmm FRLS, PVC insulated andunsheathed multi strandedflexible copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with sunk cast iron/pressed steel terminal boxes(sheet not less than 1.6mm thick) of adequate size with suitable thickness plastic laminated sheet cover 3mm thick for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm FRLS, PVC insulated and unsheathed copper conductor cable(multistranded)as earth wire to common earth dolly, complete all as per specified and directed. |
| 59 | S & F for switch piano flush type one way 5 amps SP complete all as specified and directed. Make: Havells (REO) or technocommerically equivalent make ofcona/SSK. |
| 60 | S & F for switch piano flush type one way 15 amps SP complete all as specified and directed. Make: Havells (REO) or technocommerically equivalent make ofcona/SSK. |
| 61 | S & F socket outlet3 pin 5 amps flush type complete all as specified and directed. Make: Havells (REO) or technocommerically equivalent make of cona /SSK. |
| 62 | Supplying &Fixing socket out let, 6 pin, 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts, complete all as specified and directed Make: Havells (REO) or technocommerically equivalent make of cona /SSK. |
| 63 | S&F ceiling rose surface 65x50mm three terminal with bakelite back plate complete all as specified and directed. |
| 64 | S&F fan regulator electronic flush type stepped (rotary type) with 5 steps speed control complete all as specified and directed. |
| 65 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose of make : Philips, cat part No :BN170C LED20S-6500 PSU L120/Havells, Cat part no: LUMILINEPLUSNEOBS20WLED865SPCSSIND/ Crompton, cat part no : CCS-100-20-65-HL2-DP-NWH/ Orient, cat part no :LBLN-20-C-SQ-AL complete all as specified and directed. |
| 66 | Supply and fix smart inverter type, air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rating on an AC indicates, highly energy-efficient230 Volt complete fix on wall including copper tube, electric wire as requireddrainout pipe complete all as specified and directed . Make: Voltas/carrier/\"O\" general |
| 67 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed . |
| 68 | S&F double door4 way VTPN DBs are fitted with Bus Bars, Neutral Links, Blanking Plates with MCCB four pole, 100 Amp, 25 KA, 415 Volt supply having protection IP 43, G frame fitting on wall with anchor fastner and doing all electrical connection complete all as specified and directed. Make : L&T /C&S/Schenider/Legrand. |
| 69 | S&F MCB SP 6-32 Amps with 10KA breaking capacity of \"B\" series in distribution board complete all as per specified and directed. |
| 70 | Supply and fixing 415V 10KA \"B\" curve miniature circuit breaker (MCB) TPN 40 to 100 Amp current carrying capacity in the DB complete with connection testing and commissioning complete all as per specified and directed. |
| 71 | S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB complete all asspecified and directed. |
| 72 | S&Fsub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area4.0 Sqmm drawing into and including PVC non metallic rigid conduit of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 4.0 Sqmm as a earth continuity conductor(green colour) in and including in non metallic rigid PVC conduit, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as per specified and directed. Note :- (i)Rates are deemed to be included chases of conduit and sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii)Two run of4.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 4.0 sqmm copper conductor cable (FRLS)as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit. |
| 73 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanizediron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thickRCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced withsuitable handle and angle iron frameand necessary excavation and earth work in any type of soil etc. complete all asspecifiedand as directed includingtesting on completion. (Note: The rate quoted include cost of min 7.5 metre earthling wire .) |