| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sqm each including making good the disturbed portion of wall with new or old brick lintels cills etc including brick work of jambs and cill in CM 1:4 complete all as specified and directed |
| 2 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm each not exc 4.00 sqm each including making good the disturbed portion of wall with new or old brick lintels cills etc including brick work of jambs and cill in CM 1:4 complete all as specified and directed |
| 3 | S&F factory made Steel Window 1.25mm thick Box Type (primer coated) ERW hollow P section of size 60mm x 25mm. 1.25mm thick sheet single rebated comprises glazed Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick incl cutting holes and making good dismantled portion with using PCC 1:2:4 type B-1 using 20mm graded stone aggregate four nos for each window including following fitting welded to frame shutter:- (a) Mild Steel Hold Fast, 150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 Noper leaf (e)Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf as per TD No.LZ/C-TD/130 complete all as specified and directed. Note: Glass pan and painting shall be measured and paid separately under appropriate item. |
| 4 | S&F factory made Steel Window 1.25mm thick Box Type (primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises gauged Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thickincluding cutting holes and making good dismantled portion with using PCC 1:3:6 type C-1 using 20mm graded stone aggregatefour nos for each window including following fitting welded to frame shutter: (a) Mild Steel Hold Fast 150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mmx20mmx63mm welded to hinges – 01 Noper leaf (e)Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (f) Grills made out of MS Square bar 12mm welded to GI frame and 100 mm spacing of guard bar as per TD No.-LZ/C-TD/130 complete all as specified and directed. Note: Wire mesh and painting shall be measured and paid separately under appropriate item |
| 5 | Ditto all as above but in Steel ventilators, fixed type, complete with glazing bars/gauzed portion dovetailed or weldedetc complete all as specified and directed. |
| 6 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed |
| 7 | S & FStainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed |
| 8 | M&L Preparing new surface of steel and applying two coats of synthetic enamel paint, complete all as specified and as directed. |
| 9 | Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing downwith water complete all as specified and directed |
| 10 | M & L 10 to 12 mm thickready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering ( as per manufacturer instruction ) over interior surface of walls and applying two coats of Oil Bound Distemper over 1mm thick wall care putty complete all as specified and directedNote - Coverage for smart care ready mix plaster will be 24-28 kg/sqm) |
| 11 | M & L 10 to 12 mm thick samrt care ready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering ( as per manufacturer instruction ) over exterior surface of walls and applying two coats of cement based paint over alkali resistant primer complete all as specified and directedNote - Coverage for smart care ready mix plaster will be 24-28 kg/sqm) |
| 12 | M & L Brick work with sub class \"B\" bricks, straight or curved on plan exc 6m mean radius built in cm (1:6) complete including demolition of brickwork complete all as specified and directed |
| 13 | Ditto- all as per above but except Bricks including demolition of brickwork etc complete all as specified and directed. |
| 14 | Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving n.exc 15cm thickness (below or above ground level) etc complete all as specified and directed. |
| 15 | M & L 75 mm thick PCC 1:3:6 type C-2 using 40mm graded aggregateds as in plinth protection, sub base of floors incl joint filling with bitumen and coarse sand mixture 1:3 by weight at the joints complete all as specified and directed. |
| 16 | M & L for vitrified ceramic light shade tiles 8-10mm thick polished area of each tile not exc.0 .36 sqm in floor and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade complete laid over 15mm thick screed bed in mortar CM (1:6) including dismantling of tiles in any position including cement mortar bedding complete all as specified and directed |
| 17 | M&L for 25mm thick Cement concrete type B-1, 1:2:4 (12.50mm graded aggregate) as in base of flooring complete all as specified and directed |
| 18 | M & L Non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exc 0.18 sqm but not exc 0.38 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 including dismantling of tiles in any position including cement mortar bedding complete all as specified and directed |
| 19 | M & L forGlazed ceramic tiles in vertical surface 450 x 300 x 7mm thick coloured tiles, set and jointed in neat cement slurry and pointed in white or colour cement to match, over and inlcuding 10 mm thick rendering on fair faces of brickwork or concrete surface ofvertical in CM (1:4) including dismantling of tiles in any position including cement mortar bedding complete all as specified and directed |
| 20 | Taking down roof trusses, coupled rafters or trussed beams above 4 mtr & upto 8 mtr clear span complete all as specified and directed |
| 21 | Dismantling timber scantlings in framed work 40 sq. cm and over in section, in any position complete all as specified and directed |
| 22 | S&F in Roof trusses (framed) of grade Fe 410 - W (Gde E- 250) quality A (Beam, tee, angle, channel, hollow or flat sections) including distance pieces, cleats etc complete all as specified and directed |
| 23 | S&F Rolled sections of grade Fe 410 - W (Gde E- 250) quality A as in main and cross beams, hip and jack rafters, purlins fixed with angle cleats or other connecting plates complete all as specified and directed |
| 24 | S&F Plates (plain or chequered) of grade Fe 410 - W (Gde E- 250) quality A channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed |
| 25 | Dismantaling of asbestos cement (Corrugated, semi corrugated) sheetiting in roof covering complete all as specified and directed |
| 26 | S & F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering fixed with self tapping screws complete all as specified and directed |
| 27 | S & F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering, ridge, valley gutter etc fixed with self tapping screws as specified and directed. |
| 28 | S&F Framed work of grade Fe 410 - W (Gde E- 250) quality A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings including mild steel hinges, hand made mild steel sliding door bolt, mild steel handles and all necessary fittings (exclusive of steel sheeting or other covering) and hanging; also fastening and fixing complete all as specified and directed |
| 29 | Dismantling timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed |
| 30 | Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates of grade Fe-410-W (Gde E-250), etc complete all as specified and directed. |
| 31 | Mild steel in flat, round or square bars, in available lengths of grade Fe 410 - W (Gde E- 250) quality A as in wind ties, framing, cladding, doors etc complete all as specified and directed |
| 32 | S&F Expanded metal of weight n exc 4kg/Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all specified and directed |
| 33 | S&F 1.00mm thick mild steel plain black sheet in covering to door shutters cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc. with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed |
| 34 | M&L Preparing new surfaces of steel and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed. |
| 35 | Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets |
| 36 | S&F False Ceiling Horizontal level regular edge grid 600 x600 mm frame work using hot dip sections and fixing tiles vinyl laminated MPL gypsum panels size 595x595x6mm thick after lamination, suspended the grid with grid hangers to Roof Truss / RCC Slab all as per manufactured instructioncomplete all as specified and directed. |
| 37 | Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such asswitches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified. |
| 38 | Taking down copper / aluminium sub main wiring and making good distrubed surfaces to match with the existing surface roof / wall / floor complete all as specified and directed. |
| 39 | Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area)single core FRLS PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunkenterminal box (Min 60mm deep, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLS PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)complete all as specified and as directed. Note- Switch, socket, Regulator& paid separately. |
| 40 | All as per item 39 here in before but for One 5 pin 5 Amp socket point with switch on an independent board with 2.5 Sqmm (FRLSH) copper conductor cable complete all as specified and directed. |
| 41 | All as per item 39 here in before but for One 5 pin 5 Amp socket point with switch on same board complete all as specified and directed. |
| 42 | All as per item 39 here in before but for one 15 Amp 5/6 Pin switch socket combination independent with4.0 Sqmm (FRLSH) unsheathed copper conductor single core multistranded complete all as specified and directed. |
| 43 | S&F Switch Piano flush type 5 Amp single pole one way complete all as specified and directed. |
| 44 | S&F socket outlet 2 in 1, 3 pin, 6A complete all as specified and directed. |
| 45 | S&F switch combination 2 in 1 flush type 16 Amp 5 pin complete all as specified and directed. |
| 46 | Supply and fix electronic fan regulator 5 stepped type complete all as specified and directed |
| 47 | S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed. |
| 48 | M&L for sub main wiring with two single core 6 Sqmm (FRLS) copper conductor PVC insulated and unsheathed cableincluding PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm (FRLS) insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. (Note :- Two runs of 6 sqmm FRLS and one run of 6 sqmm (FRLS) copper conductor shall be measured as one unit length.) |
| 49 | S&F in replacement of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp vertical distribution board 12 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including fixing MCCB & MCB connection with aluminium thimbles as required complete all as specified and directed. |
| 50 | S&F in replacement of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection as required complete all as specified and directed. |
| 51 | S&F of MCCB 100 Amp, 16KA,4 Poleincluding complete electricalconnection by appropriate size of aluminium lugs complete all as specified and directed |
| 52 | S&F of MCB SPN 63 Amp 240 volt \"C\"curve 10 KA complete all as specifed and directed. |
| 53 | S&F of MCB SP 10 to 32 Amp 240 Volt \"C\" curve 10 KA complete all as specified and directed. |
| 54 | Supply and fixing LED lights fitting 4 Ft, 20W, 220V, AC, batten type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 55 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 56 | S & F building security LED Light 30 Watt sensor based made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-65 protection and impact resistance of IK 07 for building secuity purpose with bracket size made of GI pipe medicum grade 25 mm dia 1.2 mtr long bend to shape as required and fixing with two nos MS Clamp of size 25x6 mm for fixing of builiding security light fittings completed all as specified and directed. |
| 57 | S&F in replacement of metal plug & socket DB with MCBs single pole with a two pin earth plug and socket suitable for 20 Amp complete with one single pole MCB complete all as specified and directed. |
| 58 | Taking down and Up of ceiling fan including accessories such as down rod (upto 600mm length), canopy and fan blade and refixing the same with flexible copper wire of size 23/0.0076 Sqmm upto 0.40 mtr with fan connector to ceiling rose complete all as specified and directed. |
| 59 | M & L for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly into ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to GIearth wire of size 4 mm dia by means ofbolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electricl plate No.3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable earthing (above GL only) complete all as directed including dismantling of existing earthing.Note:- On testing after completion if desired earth resistence is not obtained the earthing will be redone at no extra cost. |