| 1 | Dismantling, wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, includingcover fillets and Snap grid and hanger complete all as specified and directed |
| 2 | M&L for 6 mm thik Non asbestos fiber cement building boards fixed with screwed in celling flat or sloping including S&F anodised Aluminium snap grid fram work size of grid 605x605mm for false ceilling with hanger 6 mm dia GI (upto 1200 mm length), cleats made out to GI flat 40x3 mm Size 60mm long and expension hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed |
| 3 | Demolition of brick work in cement mortar including all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 4 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed |
| 5 | M&L forbrick work with sub class \"B\" bricks old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified and directed. |
| 6 | M & L Rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces to be finished even and fair without using extra cement complete all as specified and directed. |
| 7 | M & L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primercomplete all as specified and as directed. |
| 8 | M&L for Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 9 | M&L for preparation of new plastered surfaces and applying two coats of OBD over 1 mm thick wall care putty complete all as specified and directed. |
| 10 | Dismantling of Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 11 | S&F in repair Pre-paintedgalvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with selfm tapping screws complete all as specified and directed. |
| 12 | S&F in repair Pre-paintedgalvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall/ridges, fixed with self tapping screws as complete all as specified and directed. |
| 13 | Demolition of cement concrete in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified. |
| 14 | M & L 25 mm thk cement conc. Type B-0 1:2:4(12.5mm graded crushed stone aggregate) as in sub base to floor complete. |
| 15 | M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , laid over & including 15mm thick cement screed bed or bedding layer in CM 1:6, etc. complete all as specifiedand directed by Engr-in-Charge. |
| 16 | M&L Glazed ceramic tiles in vertical surface 350 x 250 mm x 7mm / 450 X 350 X 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed. |
| 17 | M&L for 10mm thick rendering/screeding on fair faces of brick / concrete surfaces in cement mortar 1:4 and finished even and fair for receiving tiles as in skirting/dado complete all as specified. |
| 18 | M&L 20 mm th Granite (of any type) work (table rubbed and polished) in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over 15 mm th screed in CM 1:6 complete all as specified and directed. |
| 19 | Taking down chowkats or frame with shutters ( without taking off shutter from frame ) n exc 1.50Sqm each complete all as specified and directed. |
| 20 | Taking down chowkats or frame with shutters ( without taking off shutter from frame )exc 1.50Sqm but n exc 4.0 sqm each complete all as specified and directed. |
| 21 | S&F Anodised aluminium frame power coated for doors, windows, ventilatorsr (minimum thickness of powder coating 50 micron)with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 22 | S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc powder coating of any colour (Thickness or powder coating not less than 50 micron). complete all as specified and directed by Engr in Charge. |
| 23 | S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed. |
| 24 | S&F 150 mm, long, Aluminium anodised, barrel tower bolt of extruded section and fixed. |
| 25 | S&F 150 mm long , extruded aluminium alloy handles fabricated type anodised and fixed. |
| 26 | S&F Aluminium anodised sliding door bolt 250 mm long plate type stove enamelled black with bright bolt not less than 12 mm dia with and incl a minimum of 6 bolt and nutfour on bolt plate and two on staple plate and fixed. |
| 27 | S&F Galvanized mild steel wire cloth of 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples or with wooden beads, screws and nuts botls etc. all as directed. |
| 28 | Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc.powder coating of any colour (Thickness or powder coating not less than 50 micron). complete all as specified and directed by Engr in Charge. |
| 29 | S&F in repair PVC connection 15mm size with PTMT Nut of length 450mm complete all as specified and directed. |
| 30 | S&F in repair vitreous china white wash basins, angle back type of size 400mmx400mm including brackets, cutting for and pinning the ends of brackets or erecting stands including 32mm bore dia waste coupling of PTMT ( Half or full threaded) ,(minimum weight 32 mm-45mm-60gms) with32 mm High density polyethylene pipes (HDPE) of pressure rating 6kgf/cm² fixed complete to walls in floors complete all as specified and directed. |
| 31 | S&F in repair600mmx450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 32 | S&F in repair 15mm Pillar taps, fany type cast copper alloy, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 33 | S&F in repair Bib tap(15 mm) standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms / 20mm125gms) complete all as specified and directed. |
| 34 | S & F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed. |
| 35 | S & F in repairs vitreous china squatting pan orissa pattern long pan size 580 mm x 440 mm white with spun pipe ‘P’ or ‘S’ trap including lead joint and CI spun branch piece , front or back inlet and foot rests excluding flushing cistern & flush pipe but incl. cement concrete bedding fixed complete all as specified and as directed. |
| 36 | Dismantling wrought iron / Mild Steel work of any description not otherwise provided for complete all as specified and directed. |
| 37 | M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe 410-W (Gde-E- 250) quality-A and painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication, complete all as specified and directed. |
| 38 | M & L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection finish without using extra cement complete all as specified and directed. |
| 39 | Taking up or down steel tubing and connections,15mm dia, including cleaning for refixing or removal to store Complete all as specified and directed. |
| 40 | S&F GI tubes medium grade with all fitting fixed to wall and ceilling or laid in floor of 15 mm bore of pipe complete all as specified and directed. |
| 41 | S&F in repair for framed workfor portions framed and hung as gates,including hinges,stops,hand-made sliding bolts etc. conforming to Fe.290.Gde-E-165 complete all as specified and directed |
| 42 | S&F in repair Expanded metal of weight less then 4.00 kg/Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed. |
| 43 | Dismantling of water tankscapacity exc 500 ltrs and n.exc 1000 ltrs and removing to store complete all as specified and directed. |
| 44 | S & F 1000 litre rotational moulded double layer polyethlene water storage tank ISI mark engraved white colour (cylindrical vertical with closed threaded top) and suitable size of MS tasla with locking system hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 45 | S&Fin repair 15 mm bore cast copper alloy CI concealed Stop cock fancy typescrewed down for iron pipe and fixed to 15mm bore pipe , complete all as specified and directed. |
| 46 | Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such asswitches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed. |
| 47 | Taking down copper/aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed |
| 48 | M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLSH) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLSH) multistrandedcopper conductor cable PVC insulated and unsheathed, drawn in & including concealedPVC rigid conduit medium grade with fittings (ISI marked) sunken pressed steelgalvanised terminal boxes with top cover ISI marked plastic laminated hylam sheetfor housing/ fixingswitches for one light / holder / fan / exhaust fan / bell point controlled by one switch complete all as specified and directed for the following-Note- (i)The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour. |
| 49 | All as per item No.48 here in before but for one 6 Amp socket point with switch on an independnet board with 2.5 sqmm (FRLSH) copper conductor cable complete all as specified and directed. |
| 50 | All as per item No.48 here in before but for one 6 Amp socket point with switch on same board complete all as specified and directed. |
| 51 | All as per item No.48 here in before but for one 16 Amp socket point with switch on independent board with 4.0 Sqmm (FRLSH) unsheather copper conductor single core multistranded complete all as specified and directed. |
| 52 | S&F Switch Piano flush type 6 Amp single pole one way complete all as specified and directed. |
| 53 | S&FSocket 2 in 1, 3 Pin 6 Amp complete all as specified and directed. |
| 54 | S&Fswitch socket combination 2 in 1flush type 16 Amp 3/5 Pin complete all as specified and directed. |
| 55 | Supply and fix electronic fan regulator 5 stepped type complete all as specified and directed |
| 56 | S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed. |
| 57 | M&L in replacement for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cableincluding PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm FRLSinsulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed.( Note :-Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper conductor shall be measured as one unit length.) |
| 58 | Supply and fixing in repairVTPN DB 12 way suitable for Mounting MCCB as Incomer of rating 100 Amp with suitablerated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed. |
| 59 | Supply and fixing in repair MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed. |
| 60 | S&F in repair of MCCB 100 Amp, 16KA,4 Poleincluding complete electricalconnection by appropriate size of aluminium lugs complete all as specified and directed |
| 61 | S&F in repair of MCB SPN 63 Amp 240 volt \"C\"curve 10 KA complete all as specifed and directed. |
| 62 | S&F in repair of MCB of MCB SP6 to 32 Amp 240 Volt \"C\" curve 10 KA complete all as specified and directed. |
| 63 | S&F in repair of LED lights fitting 4 feet, 20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 64 | S & F in repair building security LED Light 30 Watt made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-65 protection and impact resistance of IK 07 for building secuity purpose with bracket size made of GI pipe medicum grade 40 mm dia 1.5 mtr long bend to shape as required and fixing with two nos MS Clamp of size 40x6 mm for fixing of builiding security light fittingscompleted all as specified and directed. |
| 65 | S&F in repair of metal plug & socket DB with metal plug and MCBs double pole and neutral enclosere with a two pin earth plug and socket suitable for 20 Amp complete with one single pole MCB complete all as specified and directed. |
| 66 | Supply and Laying in replacement cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed. |
| 67 | S & F of 40 mm bore GI Tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS Clapms and nut and bolts/washer complete incl dismentling all as specified and directed. |
| 68 | M & L Sand cushioning for cables complete all as specified and directed . |
| 69 | M & L for old size brick well burnt, laid flat, for cable protection complete all as specified and directed. |
| 70 | Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any type of soil complete all as specified and directed. |
| 71 | Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed |
| 72 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed |
| 73 | Taking down and up of existing ceiling fan including accessories such as down rod, canopy and fan blade and refixing the same with flexible copper wire of size 23/0.0076 Sqmm upto 0.40 mtr with fan connector to ceiling rose complete all as specified and directed |
| 74 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown in electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed incl dismantling of exsisting earthing. (Note :-On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.) |