| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 250 meters lead. |
| 2 | Dismantling steel work (MS Channels, angles, tees and flat etc.) in single sections including dismembering and stacking within 250 meters lead |
| 3 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 250 meters lead of: G.S. Sheet |
| 4 | Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 250 meters lead as per direction of Engineer-in-charge. |
| 5 | P/L 15 mm cement plaster of 1:4 (1 cement: 4 coarse sand) on brick work as per direction of Engineer-in-charge |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 7 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering: 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering 1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources |
| 9 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specification. |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete: Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and including two coats of synthetic enamel paint all complete. |
| 12 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and including two coats of synthetic enamel paint all complete. |
| 13 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, and including two coats of synthetic enamel paint and including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes |
| 14 | Providing corrugated G.S. sheet roofing (0.63 mm thick with zinc coating not less than 275 gm/m²) with polyurethane foam (PUF) insulated sandwich panels, including vertical/curved surfaces, fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping sheets complete (up to any pitch in horizontal/vertical/curved surfaces), excluding cost of purlins, rafters and trusses, and including cutting to size and shape wherever required. |
| 15 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make, Anodized aluminum (anodized transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge: |
| 16 | Filling the gap, Upto 5mm depth and 5 mm width, in between aluminum frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete: |
| 17 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. : Three track three panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window up to 1.75 sqm) |
| 18 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). |
| 19 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. |
| 20 | Providing and fixing aluminum handles of size 125mm, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS: 1868) |
| 21 | Providing and fixing aluminum hanging floor door stopper (twin rubber), ISI marked, anodized (anodic coating not less than grade AC 10 as per IS: 1868) |
| 22 | Providing and fixing bright finished 100 mm mortice lock with 6 levers of approved quality for doors, with necessary screws etc complete as per direction of Engineer- in-charge. |
| 23 | P/A EPU patching compound (Cipycrete of Cipy Polymers or equivalent of Asian, Sika, Fosroc) for floor repair / crack after removing loose patches/glass strip of floor (which are not repairable by simple mortar / putty) before P/A epoxy coating wherever directed. |
| 24 | Providing and laying Epoxy floor coating to flooring and skirting surface as per described method and specification including cleaning, priming, and coating in two layers with reputed brands (Chemisol, Fosroc, MRF, etc.) complete in all respects as per Engineer-in-Charge. |
| 25 | Providing and Fixing 15 mm thick densified tegular edged ecofriendly light weight gypsum coated false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanizing@ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm center to center, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main ’T’ at 600 mm center to center to form a grid of1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size (24x24X3000 mm made of 0.40 mm thick (minimum)sheet with the help of Rawl plugs at 450 mm center to center with 25mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm Dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanized steel level clips of size 85 x 30 x 0.8 mm, spaced at1200 mm center to center along main ‘T’, bottom exposed with 24mm of all T sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note: - Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50(Minimum), light reflection > 85%, non- combustible as per B.S.476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 26 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 27 | Providing and applying white cement-based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 28 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 29 | Applying priming coats with water thin able cement primer on wall surface having VOC content less than 50 grams/litre of approved brand and manufacture, having low VOC content. |
| 30 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC content less than 50 grams/liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work |
| 32 | Providing, fabricating, supplying installing and fixing in position Aluminum Composite Panel Cladding, of 4mm thick aluminum composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminum sheets (each 0.5mm thick). The aluminum composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumi Flon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. with open grooves for linear as well as curvilinear portions of the pipe racks, of approx. 4 meter heights. Base frame work for ACP cladding is payable under the relevant MS items.The Contractor shall provide curtain wall with aluminum composite panel cladding, having all the performance characteristics all complete, as per the drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 33 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in paneling fixed in aluminium doors/windows/partition frames with C.P. brass / stainless steel screws etc., complete as per drawings. |
| 34 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, walls (any thickness) Columns, piers, abutments, pillars, posts and struts etc. |
| 35 | Providing and fixing bright /matt finished Stainless Steel handles 100mm of approved quality & make with necessary screws etc. all complete. |
| 36 | Providing and fixing magnetic catcher, triple strip vertical type of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete |
| 37 | Providing and fixing aluminium tower bolts 200x10, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. |
| 38 | Providing and fixing bright finished 100 mm mortice lock with 6 levers of approved quality for doors, with necessary screws etc complete as per direction of Engineer- in-charge. |
| 39 | P/F 75mm UPVC waste pipe supply including all fitting. This includes jointing of pipe & fittings/fixture with one step PVC solvent cement as per direction of Engineer-in-Charge. |
| 40 | Credit for taking away old dismantled damaged MS doors /cupboard shutter, MS section, GS roofing sheet including other electrical, water supply material from dismantling shall be property of contractor; after dismantling weight to be measured before removing from the site in the presence of IUAC engineer /in charge or his authorized representative shall be taken for credit all complete. |
| 41 | Providing and fixing glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both sides, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 42 | Welding by gas or electric plant including transportation of plant at site etc. complete as per direction of Engineer-in-Charge. |
| 43 | Providing structural design of MS Staircase and trusses as per provisions of IS codes and preparing shop drawings & structural analysis for fabrication after approval from IUAC for this work, after conducting a site visit and collecting all necessary site inputs. The design and drawings shall include all relevant structural details, welding joint details, execution-related specifications, and the structural stability statement. The design must ensure safety, stability, and full adherence to accepted professional engineering practices.Note: The entire exercise shall be treated as one job on a lump-sum basis, irrespective of the number of revisions, remarks, corrections, or modifications required during the design and approval process. No additional claim on account of re-measurement or extra payment shall be entertained on any grounds. |
| 44 | Supply and fixing of 4 Way (4+12) Vertical TPN, 415V, 3 phase AC, surface mounted, double door MCB distribution board made out pf MS powder coated sheet inclusive of TPN insulated bus bar of 160 Amp capacity of make: Havells, ABB, Siemens, L&T, Legrand etc. as required. |
| 45 | Supply and fixing in existing VTPN MCB distribution board following single phase and three phase \"C\" Curve MCB having breaking capacity of 10 kA of make: Havells, ABB, Siemens, L&T, Legrand etc. as required for above DB: 4 Pole, 63 Amp C Curve MCB |
| 46 | Supply and fixing in existing VTPN MCB distribution board following single phase and three phase \"C\" Curve MCB having breaking capacity of 10 kA of make: Havells, ABB, Siemens, L&T, Legrand etc. as required for above DB: 1 Pole, 10 Amp C Curve MCB |
| 47 | Supply and fixing in existing VTPN MCB distribution board following single phase and three phase \"C\" Curve MCB having breaking capacity of 10 kA of make: Havells, ABB, Siemens, L&T, Legrand etc. as required for above DB: 1 Pole, 25 Amp C Curve MCB |
| 48 | Supply and fixing in existing VTPN MCB distribution board following single phase and three phase \"C\" Curve MCB having breaking capacity of 10 kA of make: Havells, ABB, Siemens, L&T, Legrand etc. as required for above DB: 1 Pole, 15 Amp C Curve MCB |
| 49 | Supply and fixing on wall FRLS PVC casing caping of size 50x50 mm with readymade bends and Tee as required for laying electrical power wiring of make: L&T, Legrand, AKG. |
| 50 | Supply & fixing on wall of 2x5/15A modular sockets with 2x5/15A switches including suitable MS box, modular plated, covers switches and sockets including internal wiring etc as required. |
| 51 | Supplying, installation, testing and commissioning 595*595 mm (N.S)LED panel light having greater than 4000 lumen, temperature > 6000 k, efficacy>110 lumens/watt suitable for 2\"x2\" cut out complete with all accessories and driver etc., i/c connection with 1.5sqmm PVC insulated copper conductor wire connector and suitably installed with the help of suspension wire/chain wherever required of make\": Phillips, Havells, Crompton, Bajaj complete as reqr. : Group C |
| 52 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as reqr.: 2*1.5 sqmm+1*1.5 sq mm earth wire |
| 53 | Supplying and fixing 25mm steel conduit along with the accessories in surface/recessed including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required |
| 54 | Wiring for power wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/recessed steel conduit, casing caping as reqr. 2*4 sq mm + 1*4 sq mm FRLS copper wire |
| 55 | Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.: 3 Module (100mmX75mm) |
| 56 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.: 5/6A Switch |
| 57 | GST |