Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Site Preparation |
| 2 | Earthwork in excavation by manual/ mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m andlift up to 1.5m, as directed by engineer-in-charge. (a) All kinds of soil |
| 3 | RETAINING WALL |
| 4 | Earthworkinexcavationbymanualmeansuptoadepthof 2mbelow the existingground level for foundation trenches of foundations,footingsofcolumn/ walls,retainingwalls,septic tanketc. including bailingoutwaterwhere necessaryand removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. (a) In ordinary rock (soft rock/ medium rock/ hard shale) |
| 5 | Plain cement concrete works in foundation bed for footing steps, walls, brick worksetc below plinth levelas directed and specified including dewatering if necessary,and curing complete (shuttering where necessary shall be measured and paid separately).(a)1 :3:6 (1Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 6 | Providingregularstone masonryinretainingwalls etc. with coursed, hammer dressedor blunt chiseldressedstones Of heavysectionnotlessthan 25x25x30cmwithproperkey stoneeachnotlessthan25x25x75cm long set in cement mortar 1 :6 (1cement: 6sand) including filling of trenches and providing ofweepholes at 1.20 to 1.50metres apart staggered. |
| 7 | Providing boulder or stone filling with boulders or stones 15cm size, 60cm widebehind the rctaining wall etc. complete as directed. |
| 8 | Cement plaster 1:3 (1cement: 3 coarse sand) finished with a floating coat Of neat cement(a)20 mm cement plaster |
| 9 | Providing and fixing Bamboo jaffri/ fencing consisting of superior quality 25mm dia. (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of hollock wood in scantling of section 50x25mm, fixed with nail and G.I wire on an existing support complete as per direction of Engineer-in-charge |
| 10 | Extra for carriage including loading and unloading and all charges complete beyond the initial lead of 5 Km.BOULDER: CONSIDER TOTAL LEAD =25 KM(i) Stone masonary |
| 11 | For 5-10 km (5km) |
| 12 | For 10-20 km (10km) |
| 13 | For 20 km (25-20=5km) |
| 14 | (ii) Stone Filling |
| 15 | For 5-10 km (5km) |
| 16 | For 10-20 km (10km) |
| 17 | For 20 km (25-20=5km) |
| 18 | (ii) ORDINARYSTONE AGGREGATE: CONSIDER TOTAL LEAD = 25 KM100mm PCC (1:3:6) |
| 19 | For 5-10 km (5km) |
| 20 | For 10-20 km (10km) |
| 21 | For 20 km (25-20=5km) |
| 22 | (iii) RIVER SAND: CONSIDER TOTAL LEAD = 65 KM100mm PCC (1:3:6) |
| 23 | For 5-10 km (5km) |
| 24 | For 10-20 km (10km) |
| 25 | For 20 km (65-20=45km) |
| 26 | OFFICE |
| 27 | Earthwork in excavation upto a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.(a) All kind of soil(Ordinary soil/hard soil/ dense soil) |
| 28 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level andin panel after preparing the subgrade as directedincluding all labour andmaterials andif necessary dewatering, complete.(b) Stone soling(i)l00 mm |
| 29 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(b) 1:3:6 (1 cement: 3 coarsesand: 6 graded stone aggregate 20mm nominal size) |
| 30 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand; 12 grade stone qaggregate 20mm nominal size ) up to plinth level with : (a) cement mortar 1:6 (1 cement: 6 coarse sand) |
| 31 | Supplying, fitting and fixing in position reinforcement bars upto 1st floor level, conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports,chairs, spacers etc. complete.(Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurements for the same is required) (c)Thermo-Mechanically Treated bars |
| 32 | Shuttering/Formwork Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by engineer in charge |
| 33 | Foundations, Footing, bases of columns, etc. for mass concrete (using steel) |
| 34 | Columns, Pillar, Piers, Abutment, Posts and Struts (using steel) |
| 35 | Lintel, Beam, Plinth beams, girder, bressumer and cantilever (using steel) |
| 36 | Providing and laying in position in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up plinth level: (b) M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 grade stone aggregate 20mm nominal size) |
| 37 | Reinforced cement concrete work in walls (any thickness) including attached pilaster, buttresses, fillets, columns, pillars, post and struts etc. above plinth level up to first floor level, excluding cost of centering and shuttering, finishing and reinforcement:(b) M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 grade stone aggregate 20mm nominal size) |
| 38 | Reinforced cement concrete work in beams, slab, roofs, having slope up to 15˚, landings, balconies, shelve, chejjas, lintel, bands, plain window sills, staircase and spiral stair case above plinth level up to first floor level, excluding cost of centering and shuttering, finishing and reinforcement:(b) M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 grade stone aggregate 20mm nominal size) |
| 39 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc in layer not exceeding 20cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50m and lift up to 1.5m.(a) with available excavated earth |
| 40 | Half brick masonry with common burnt clay (non modular) 1st class bricks in superstructure above plinth levelup to first floor level . (a) Cement mortar 1:3 (1 cement: 3 Coarse sand) |
| 41 | 15mm cement plaster on rough side of single or half brick wallfinished with floating coat of neat cement of mix: (b) 1:3 (1 cement: 3 fine sand) |
| 42 | Applying one coat of water thinnable cement primer of approved brand and manufacture on surfaces:Water thinnable cement primer. |
| 43 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: (a)New work (two or more coated over an under coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture) |
| 44 | Providing wood works in frames of doors, window, clerestory window and other frames, wrought frame and fixed in position with hold fast lugs or with dash fasteners of required diameter and length.(c) with first class local wood(ii)Champa/ Diengrai |
| 45 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory window, all complete with: (a) 4.0mm thick glass panes. |
| 46 | Providing and fixing panelling or glazing in panelled or panelled and slazed shutters for doors, windows and clerestory windows (area of opening for panel insert excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutter 25mm to 40mm thick: (c) With 1st class local wood(ii) Champa/ Diengrai |
| 47 | Providing and fixing IS:12817 marked Stainless steel butt hinges with stainless steel screws etc. complete (a) 125X65X1.9mm |
| 48 | Applying priming coat: (a) with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) with ready mixed alluminium primer of approved brand and manufacture on resinous wood and plywood |
| 49 | FinishingwithDeluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications, including scaffolding:(b)Painting wood work with delux multi surface Paint of required shade. Two or more coats applied @ 0.9. ltr/10sqm over an under coat of primer applied @ 0.75ltr/10 sqm of approved brand and manufacture. |
| 50 | Plain cement concrete floor base in prop1 :3:6 laidin alternate bays as specifiedwith coarse aggregate of size 13mm to 32 mm including dewatering if necessary, and curing etc. complete (c)100 mm thick in prop 1:3:6 |
| 51 | Making plinthprotection 50mm thick of cement concrete1:3:6 (1 cement:3coarse sand:6 gradedstoneaggregate20mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, includingnecessary excavation, levelling & dressing & finishing the top smooth. |
| 52 | Providingandlaying Vitrifiedtilesindifferent sizes(thickness to be specifiedby the manufacturer), withwater absorption lessthan0.08%and conformingtoIS:15622, of approved brand & manufacturer, in all colours and shade, inskirting, riser ofsteps, laid with cementbasedhighpolymermodified quick set tile adhesive (water based) conforming tolS:15477, in average 6 mm thickness, including grouting of joints (Payment for groiiting of joints to be made separately).(a) Normal Range |
| 53 | ProvidingpolishedVITRIFIEDwalltilesofapprovedquality, size,shapeandthicknessnotlessthan8mmonwallsand skirtingovercementmortarbed10mmthickinprop.1:3(1 cement:3coarsesand) includingcuttingwhere necessary finishedwithflushpointingwith adhesiveorwhitecement slurrymixedwithapprovedpigmenttomatchshadeoftiles complete at all levels as specified and directed.(a)Normal range |
| 54 | Providingand fixing M.S. grills of required patternin trames of windows, etc. with M.S. flats, square or round bars, etc. including priming coat with approvedsteel primer all complete. (b)Fixed to openings/ wooden frames with rawl plugs screws etc |
| 55 | Finishing with Deluxe Multi surface paint system for interiors and exteriors usingPrimer as per manufacturers specifications, including scaffolding:(c)Painting Steel work with Deluxe Multi Surface Paint to give an evenshade.Twoormorecoatapplied @ 0.90ltr/10 sqm over an under coat ofprimer applied @ 0.80ltr/10sqmof approved brand and manufacture. |
| 56 | Steel work in build up tubular (round, square or rectangular hollow tubes etc.) Trusses etc. including cutting, hoisting, fixing in position and applying a primer coat of approved steel primer, including welding and bolted with special shaped washer etc. complete. |
| 57 | Providing corrugated G.S or galvanised iron sheet roofing including vertical/Curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washes or with G.I limpets washers filled with white lead, including a coat of approved steel primer and two coats of approved paints on overlapping of sheets complete.(up to any pitch in horizontal/vertical or curved surfaces) excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required.(a)1.00 mm thick with zinc coating not less than 275gm/sqm |
| 58 | Providing ridges or hips of width 60 cm overall width plain G.S sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia G.I limpets and bitumen washer complete. (a)0.80 mm thick with zinc coating not less than 275gm/sqm |
| 59 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120gins/sqm (bothsideinclusive) as per ls:277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia.x 50mm long with 6 mm dia. bolts, other flange Of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts Of required size and other end Of angle hanger fixed with intermediate G.I.channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, Shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia.x230 mm longG.I.wire at every junction, including fixing perimeter channels0.5 mm thick 27 mm high having flanges Of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall partition with the help Of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing Of gypsum board to ceiling section and perimeter channel with the help Of dry wall screws Of size 3.5x25 mm at 230 mm a/c, including jointing and finishing to a flush finish Of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers coveringupto150 mm on both sides ol joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: (a) 12.5 mm thick tapered edge gypsum moisture resistant board |
| 60 | Extra for carriage including loading and unloading and all charges complete beyond the initial lead of 5 Km.A.BOULDER: CONSIDER TOTAL LEAD =25 KM(i) Stone soling |
| 61 | For 5-10 km (5km) |
| 62 | For 10-20 km (10km) |
| 63 | For 20 km (25-20=5km) |
| 64 | Stone masonary |
| 65 | For 5-10 km (5km) |
| 66 | For 10-20 km (10km) |
| 67 | For 20 km (25-20=5km) |
| 68 | (ii) ORDINARYSTONE AGGREGATE: CONSIDER TOTAL LEAD = 25 KMCC (1:3:6) |
| 69 | For 5-10 km (5km) |
| 70 | For 10-20 km (10km) |
| 71 | For 20 km (25-20=5km) |
| 72 | 100mm PCC Flooring |
| 73 | For 5-10 km (5km) |
| 74 | For 10-20 km (10km) |
| 75 | For 20 km (25-20=5km) |
| 76 | C.C 1:1:2RCC works |
| 77 | For 5-10 km (5km) |
| 78 | For 10-20 km (10km) |
| 79 | For 20 km (25-20=5km) |
| 80 | (iii) RIVER SAND: CONSIDER TOTAL LEAD = 65 KMC.C 1:3:6PCC |
| 81 | For 5-10 km (5km) |
| 82 | For 10-20 km (10km) |
| 83 | For 20 km (65-20=45km) |
| 84 | 100 mm PCC Flooring |
| 85 | For 5-10 km (5km) |
| 86 | For 10-20 km (10km) |
| 87 | For 20 km (65-20=45km) |
| 88 | C.C 1:1:2 RCC works |
| 89 | For 5-10 km (5km) |
| 90 | For 10-20 km (10km) |
| 91 | For 20 km (65-20=45km) |
| 92 | RESTAURANT |
| 93 | Earthwork in excavation upto a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.(a) All kind of soil(Ordinary soil/hard soil/dense soil) |
| 94 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level andin panel after preparing the subgrade as directedincluding all labour andmaterials andif necessary dewatering, complete. (b) Stone soling(i)l00 mm |
| 95 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(b) 1:3:6 (1 cement: 3 coarsesand: 6 graded stone aggregate 20mm nominal size) |
| 96 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand; 12 grade stone qaggregate 20mm nominal size ) up to plinth level with : (a) cement mortar 1:6 (1 cement: 6 coarse sand) |
| 97 | Supplying, fitting and fixing in position reinforcement bars upto 1st floor level, conforming to relevant I.S. Code forR.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports,chairs, spacers etc. complete.(Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurements for the same is required) (c)Thermo-Mechanically Treated bars |
| 98 | Shuttering/ Formwork Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by engineer in charge.Foundations, Footing, bases of columns, etc. for mass concrete (using steel) |
| 99 | Columns, Pillar, Piers, Abutment, Posts and Struts (using steel) |
| 100 | Lintel, Beam, Plinth beams, girder, bressumer and cantilever (using steel) |
| 101 | Slab, roofs, landings, balconies and access platform, shelves (using steel) |
| 102 | Weather shade, Chajjas, corbelsetc., includingedges(using timber) |
| 103 | Providing and laying in position in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up plinth level: (b) M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 grade stone aggregate 20mm nominal size) |
| 104 | Reinforced cement concrete work in walls (any thickness) including attached pilaster, buttresses, fillets, columns, pillars, post and struts etc. above plinth level up to first floor level, excluding cost of centering and shuttering, finishing and reinforcement: (b) M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 grade stone aggregate 20mm nominal size) |
| 105 | Reinforced cement concrete work in beams, slab, roofs, having slope up to 15˚, landings, balconies, shelve, chejjas, lintel, bands, plain window sills, staircase and spiral stair case above plinth level up to first floor level, excluding cost of centering and shuttering, finishing and reinforcement: (b) M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 grade stone aggregate 20mm nominal size) |
| 106 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc in layer not exceeding 20cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50m and lift up to 1.5m. (a) with available excavated earth |
| 107 | Half brick masonry with common burnt clay (non modular) 1st class bricks in superstructure above plinth levelup to first floor level . (a) Cement mortar 1:3 (1 cement: 3 Coarse sand) |
| 108 | 15mm cement plaster on rough side of single or half brick wallfinished with floating coat of neat cement of mix: (b) 1:3 (1 cement: 3 find sand) |
| 109 | Applying one coat of water thinnable cement primer of approved brand and manufacture on surfaces:Water thinnable cement primer. |
| 110 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: (a)New work (two or more coated over an under coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture) |
| 111 | Providing wood works in frames of doors, window, clerestory window and other frames, wrought frame and fixed in position with hold fast lugs or with dash fasteners of required diameter and length.(c) with first class local wood(ii) Champa/ Diengrai |
| 112 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory window, all complete with: (a) 4.0mm thick glass panes. |
| 113 | Providing and fixing panelling or glazing in panelled or panelled and slazed shutters for doors, windows and clerestory windows (area of opening for panel insert excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutter 25mm to 40mm thick:(c) With 1st class local wood (ii) Champa/ Diengrai |
| 114 | Providing and fixing IS:12817 marked Stainless steel butt hinges with stainless steel screws etc. complete (a) 125X64X1.9mm |
| 115 | Applying priming coat: (a) with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) with ready mixed alluminium primer of approved brand and manufacture on resinous wood and plywood |
| 116 | Finishing with Deluxe Multi surface paint system for interiors and exteriors usingPrimer as per manufacturers specifications, including scaffolding:(b)Painting wood work with delux multi surface Paint of required shade. Two or more coats applied @ 0.9. ltr/10sqm over an under coat of primer applied @ 0.75ltr/10sqm of approved brand and manufacture |
| 117 | Plain cement concrete floor base in prop1 :3:6 laidin alternate bays as specifiedwith coarse aggregate of size 13mm to 32 mm including dewatering if necessary, and curing etc. complete (c)100 mm thick in prop 1:3:6 |
| 118 | Making plinthprotection 50mm thick of cement concrete1:3:6 (1 cement:3coarse sand:6 gradedstoneaggregate20mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, includingnecessary excavation, levelling & dressing & finishing the top smooth |
| 119 | Providing and laying Vitrified tiles in different sizes (thickness tobespecifiedbythemanufacturer),withwaterabsorption lessthan0.08%andconformingtoIS:15622,ofapproved brand&manufacturer,inallcoloursandshade,inskirting, riserofsteps,laidwithcementbasedhighpolymermodified quick set tile adhesive (water based) conforming tols:15477, in average 6 mm thickness,including grouting of joints (Payment for groitting of joints to be made separately).(a)Normal range |
| 120 | ProvidingpolishedVITRIFIEDwalltilesofapprovedquality, size,shapeandthicknessnotlessthan8mmonwallsand skirtingovercementmortarbed10mmthickinprop.1:3(1 cement:3coarsesand) includingcuttingwhere necessary finishedwithflushpointingwith adhesiveorwhitecement slurrymixedwithapprovedpigmenttomatchshadeoftiles complete at all levels as specified and directed.(a)Normal range |
| 121 | Providingbamboomarulities,purlins,raftersincludingtying with cane sling/ Galvanised tying wire in thatch roofing complcte as directed.(a) With Bhaluka bamboo. |
| 122 | Providing thatch roofing with sun grass in layer of 75 mm thick with halfspilt bamboofilletandtyingwith galvanisedwire complete as directed.(b)150 mm thick. |
| 123 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed togcther at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements tor inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 - part 1 andM.S. top cover of required thickness tor rolling shiitters. (a) 80xl.25 mmM.S.laths with1.25 mm thick top cover |
| 124 | Providing and fixing ball bearing for rolling shutters |
| 125 | Providing and fixing Interlocking PVC Roofing Panell false ceiling at all height including providing and fixing of frame and panelling as per market rate. |
| 126 | Applying priming coat: (b) With ready mixed red oxide zinc chromate primer Of approved brand and manufacture on steel galvanised iron/ steel works |
| 127 | Finishing with Deluxe Multi surface paint system for interiors and exteriors usingPrimer as per manufacturers specifications, including scaffolding:(c)Painting Steel work with Deluxe Multi Surface Paint to give an evenshade.Twoormorecoatapplied @ 0.90ltr/10 sqm over an under coat ofprimer applied @ 0.80ltr/10sqmof approved brand and manufacture. |
| 128 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc,including cutting, hoisting, fixing inposition and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 129 | Extra for carriage including loading and unloading and all charges complete beyond the initial lead of 5 Km.BOULDER: CONSIDER TOTAL LEAD =25 KMStone soling |
| 130 | For 5-10 km (5km) |
| 131 | For 10-20 km (10km) |
| 132 | For 20 km (25-20=5km) |
| 133 | Stone masonary |
| 134 | For 5-10 km (5km) |
| 135 | For 10-20 km (10km) |
| 136 | For 20 km (25-20=5km) |
| 137 | ORDINARYSTONE AGGREGATE: CONSIDER TOTAL LEAD = 25 KMCC (1:3:6) |
| 138 | For 5-10 km (5km) |
| 139 | For 10-20 km (10km) |
| 140 | For 20 km (25-20=5km) |
| 141 | (iii) 100mm PCC Flooring |
| 142 | For 5-10 km (5km) |
| 143 | For 10-20 km (10km) |
| 144 | For 20 km (25-20=5km) |
| 145 | (iv) C.C 1:1:2RCC works |
| 146 | For 5-10 km (5km) |
| 147 | For 10-20 km (10km) |
| 148 | For 20 km (25-20=5km) |
| 149 | SAND: CONSIDER TOTAL LEAD = 65 KMC.C 1:3:6PCC |
| 150 | For 5-10 km (5km) |
| 151 | For 10-20 km (10km) |
| 152 | For 20 km (65-20=45km) |
| 153 | (i) 100 mm PCC Flooring |
| 154 | For 5-10 km (5km) |
| 155 | For 10-20 km (10km) |
| 156 | For 20 km (65-20=45km) |
| 157 | (ii)C.C 1:1:2RCC works |
| 158 | For 5-10 km (5km) |
| 159 | For 10-20 km (10km) |
| 160 | For 20 km (65-20=45km) |
| 161 | PCC PARKING, RAMP, EXTERIOR FLOOR FINISH& LANDSCAPING |
| 162 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level andin panel after preparing the subgrade as directedincludingalllabour andmaterials andif necessary dewatering, complete.(ii) 150mm |
| 163 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel) |
| 164 | Plain cement concrete floor base in prop 1 :3:6 laid in alternate bays as specifiedwith coarse aggregate of size 13mm to 32 mm including dewatering ifnecessary, and curing etc. complete.(c) 100 mm thick in prop 1:3:6 |
| 165 | Providing Vitrified Antiskid Tiles ofapproved quality size, shape not lessthan 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3(1cement:3coarsesand) complete at all level as specified and directed.(c)Deluxe range |
| 166 | 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:(b)1 :3 (1cement: 3 fine sand) |
| 167 | Providing, Supplying, fitting, fixing and laying of dressed stone block walling and tile slab (Cherra/ local stone block)laidon 25mmthick base in cementmortar 1:3 and jointed with grey cement slurry including clearing, rubbing etc. complete as directed. (a) Cherra stone block (300xl50xl00) |
| 168 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc in layer not exceeding 20cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50m and lift up to 1.5m. (a) with available excavated earth |
| 169 | Random rubble masonry with hard stone in superstructure above plinthlevelandup to tirst floor level, including levemng up with cement concrete 1 :6:12 (1cement: 6 coarse sand:12 graded stone aggregate 20 mm nominalsize)at window sill, ceiling level and the like.(a)Cement mortar 1 :6 (1cement: 6 coarse sand) |
| 170 | Extra for carriage including loading and unloading and all charges complete beyond the initial lead of 5 Km.Stone Soling |
| 171 | For 5-10 km (5km) |
| 172 | For 10-20 km (10km) |
| 173 | For 20 km (25-20=5km) |
| 174 | (i)ORDINARYSTONE AGGREGATE: CONSIDER TOTAL LEAD = 25 KM100mm PCC (1:3:6) |
| 175 | For 5-10 km (5km)= |
| 176 | For 10-20 km (10km) = |
| 177 | For 20 km (25-20=5km) = |
| 178 | (ii) RIVER SAND: CONSIDER TOTAL LEAD = 65 KM100mm PCC (1:3:6) |
| 179 | For 5-10 km (5km) |
| 180 | For 10-20 km (10km) |
| 181 | For 20 km (65-20=45km) |
| 182 | GLASS STEEL TRUSS ROOF ENTRANCE |
| 183 | Earthwork in excavation upto a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.(a) All kind of soil(Ordinary soil/hard soil/dense soil) |
| 184 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level andin panel after preparing the subgrade as directedincluding all labour andmaterials andif necessary dewatering, complete.(a) Stone soling (i)l00 mm |
| 185 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) 1:3:6 (1 cement: 3 coarsesand: 6 graded stone aggregate 20mm nominal size) |
| 186 | Steel work in build up tubular (round, square or rectangular hollow tubes etc.) Trusses etc. including cutting, hoisting, fixing in position and applying a primer coat of approved steel primer, including welding and bolted with special shaped washer etc. complete. |
| 187 | Providing and fixing of tampered glass roofing by market rate. |
| 188 | Providing bamboo maruli ties, purlins, rafters including tying with cane sling/ Galvanised tying wire in thatch roofing complcte as directed. With Bhaluka bamboo |
| 189 | 15mm cement plaster on rough side of single or half brick wallfinished with floating coat of neat cement of mix:(a) 1:3 (1 cement: 3 fine sand) |
| 190 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. (a) On steel work |
| 191 | SANITARY FITTINGS |
| 192 | Providing and fixing wash basin with C.I. brackets, 15 mm dia. CP Brass single hole basin mixer Of approved quality and make, including painting Of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 193 | Providing and fixing PTMT Bottle Trap for wash basin and sink. |
| 194 | Providing and fixing PTMT Waste Coupling for wash basin and sink, Of approved quality and colour. |
| 195 | Providing and fixing C.P. brass stop cock (concealed) Of standard design and Of approved make conforming to ls:8931 (a)15 mm nominal bore |
| 196 | Providing and fixing PTMT pillar cock of approved quality and colour (a)15 mm nominal bore, 107 mm long, weighing not less than 110 gms |
| 197 | Providing and fixing mirror superior glass (of approved quality)and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing.(b) Rectangular shape 453x357mm |
| 198 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms |
| 199 | Providing and fixing PTMT towel ring Tapezoidal shape 215mm long, 200 mm wide with minimilm distances of 37 mm from wall face with concealed fittings arrangemem Of approved quality and colour, weighing not less than 88 gms |
| 200 | Providing and fixing Toilet paper holder: C.P brass. |
| 201 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low levelwhite vitreous china flushing cistern & C.P, flush bend with fittings & C.I. brackets, 40 mm flush bend, overflowarrangement with specials Of standard make and mosquito proof coupling Of approved design complete, includingpainting Of fittings and brackets, cutting and making good the walls and floors wherever required:(a) W.C. pan with lsl marked white solid plastic seat and lid |
| 202 | Providing and fixing PVC low level flushingcistern with manually controlled device (hand lever) conforming to IS:7231, with all fittings and fixture complete.(a) 10 Litre capacity-white |
| 203 | Providing and fixing GI inlet connection for flush pipe connecting with WC pan |
| 204 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 205 | Supplying fitting and fixing vitreous chinadivision plate including fitting and fixingcompete as directed and specified.(a) Normal |
| 206 | Supplying fitting and fixing Health faucet with 1m long flexible tube with wall flange as directed and specified.(a)Normal |
| 207 | Providing and fixing PTMT grating of approved quality and colour.(i)100 mm nominal diameter |
| 208 | Multifloor trap |
| 209 | Providing and fixing Stainless Steel A ISI 804 (18/8) kitchen sink as per ls:13983 with C.I. brackets and stainless steelplug 40 mm, including painting Of fittings and brackets, cutting and making gcod the walls wherever required : (i) 610 x 460mm bowl depth 200 mm |
| 210 | Constructing soak pit 1.20xl.20xl.20 in filled with brickbats including S.W. drain pipe loo mm diameter and 1.20 in long complete as per standard design. |
| 211 | Providing and fixing M.S. grills Of required pattern in trames Of windows, etc. with M.S. flats, square or round bars, etc. including priming coat with approved steel primer all complete. (b) Fixed to opening/wooden frame with rwal plug screws etc |
| 212 | Vertical swing up Grab Bars |
| 213 | Vertical Grab bars of physically challenged toilet |
| 214 | L-Shaped Disable Grab bars left 90°angle |
| 215 | Providing Grease trap in Kitchen |
| 216 | INTERNAL WATER SUPPLY PIPE |
| 217 | Supplying, fitting and fixing PVC pipes/bends / Junctions etc.of Supreme/Prince or other ISI approved make, including joining ,fitting and fixing with clamps etc. as necessary complete at all levels including below G.L as directed and specified.PVC pipes of 6 Kg/cm2 as directed andspecified. |
| 218 | (a)110mm dia.(Soil pipe) |
| 219 | (b) 75mm dia (Waste pipe) |
| 220 | 87.5 degree PVC bend as directed and specified |
| 221 | (a) 110mm dia |
| 222 | (b) 75 mm dia. |
| 223 | 87.5 degree PVC bend with door as directed and specified. |
| 224 | (a) 110mm dia |
| 225 | 45degree PVC bend as directed and specified. (a)In exposed surfaces or in trenches. |
| 226 | (i) 110mm dia |
| 227 | (ii) 75 mm dia. |
| 228 | PVC single ‘Y’ as directed and specified. (a)In exposed surfaces or in trenches. |
| 229 | (i) 110mm dia |
| 230 | (ii) 75 mm dia. |
| 231 | PVC Plain single tee as directed and specified. |
| 232 | (a) 75 mm dia. |
| 233 | PVC reducer as directed and specified.(viii) 75mm x 63mm |
| 234 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge,. Concealed work, including cutting chases and making good the wall etc |
| 235 | (i) 40 mm nominal outer diameter pipes |
| 236 | (ii) 25 mm nominal outer diameter pipes |
| 237 | POLYETHYLENE WATER TANK (SINTEX) |
| 238 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ls:12701 marked, with cover and suitable locking arrangement and making necessaryholes for inlet, outlet and overflow pipes but without fittings and the base support.1000 Litre Capacity |
| 239 | STAGING FOR SINTEX |
| 240 | Half brick masonry with common burnt clay (non modular) lsd class bricks in superstructure above plinth level up to first floor level 1:4 |
| 241 | Filling sunken floor with broken brick bats/ stone aggregates and sand including compacting and supplying of materials complete as specified and directed for all levels. Brick bats |
| 242 | 65 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1 :2:4 (1cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 15 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix: 2 graded stoneaggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture\"s specifications. This includes cost of cement slurry, complete |
| 243 | EXTERNAL WATER SUPPLY |
| 244 | Providing and fixing chlorinated polyvjnyl chloride (CPVC)pipes, having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 in spacing. This includes jointing Of pipes & fittings with one step CPVC solvent cementand testing of joints complete as per direction of Engineer in Charge. |
| 245 | (i) 40 mm nominal outer diameter pipes |
| 246 | (ii) 32 mm nominal outer diameter pipes |
| 247 | SEPTIC TANK & FILTER BED FOR 20 USERS |
| 248 | Earthwork in excavation upto a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.(a) In Ordinary rock (soft rock/medium rock/hard shale) |
| 249 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level andin panel after preparing the subgrade as directedincluding all labour andmaterials andif necessary dewatering, complete. Stone soiling(i)l00 mm |
| 250 | Plain cement concrete works in foundation bed for footing steps, walls, brick worksetc below plinth levelas directed and specified including dewatering if necessary,and curing complete (shuttering where necessary shall be measured and paid separately).(b) 1:3:6 (1 cement: 3 coarsesand: 6 graded stone aggregate 20mm nominal size) |
| 251 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc in layer not exceeding 20cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50m and lift up to 1.5m. (a) with available excavated earth |
| 252 | Supplying, fitting and fixing in position reinforcement bars upto 1st floor level, conforming to relevant I.S. Code forR.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports,chairs, spacers etc. complete.(Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurements for the same is required) (b) High Yield Strength Deformed bars or Tors Bars |
| 253 | Shuttering/Formwork Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by engineer in chargeLintel, Beam, Plinth beams, girder, bressumer and cantilever (using steel) |
| 254 | (i) Slab, roofs, landings, balconies and access platform, shelves (using steel) |
| 255 | (ii) Columns, Pillar, Piers, Abutment, Posts and Struts (using steel) |
| 256 | Brick work with common burnt clay (non - modular) 1st class bricks in foundation and in plinth: |
| 257 | Providing and laying in position in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up plinth level: M20 r Prop 1:1 1/2:3(1 cement: 1 1/2 coarse sand: 3 - graded stone aggregates 20mm nominal size) |
| 258 | 15 mm cement plaster on rough side of single or half brick wall finished with floating coat of neat cement of mix:1:4 (1 cement :4 fine sand) |
| 259 | Cement concrete floor topping 1:3:6 (! - cement: 3 coarse sand: 6 stone aggregate) finished with a floating coat of Neat Cement, including cement slurry, complete (b) 20mm thick |
| 260 | Construction soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 261 | Extra for carriage including loading and unloading and all charges complete beyond the initial lead of 5K |
| 262 | (i) BOULDER:CONSIDER TOTAL LEAD = 25 KM |
| 263 | Stone Soling |
| 264 | For 5-10 km (5km) |
| 265 | For 10-20 km (10km) |
| 266 | For 20 km (25-20=5km) |
| 267 | (ii) Ordinary Stone Aggregate:CONSIDER TOTAL LEAD = 25 KM |
| 268 | C.C 1:3:6PCC |
| 269 | For 5-10 km (5km) |
| 270 | For 10-20 km (10km) |
| 271 | For 20 km (25-20=5km) |
| 272 | (iii) C.C 1:3:6RCC Works |
| 273 | For 5-10 km (5km) |
| 274 | For 10-20 km (10km) |
| 275 | For 20 km (25-20=5km) |
| 276 | (iv) Sand: CONSIDER TOTAL LEAD = 65 KM |
| 277 | C.C 1:3:6PCC |
| 278 | For 5-10 km (5km) |
| 279 | For 10-20 km (10km) |
| 280 | For 20 km (25-20=45km) |
| 281 | C.C 1:3:6RCC Works |
| 282 | For 5-10 km (5km) |
| 283 | For 10-20 km (10km) |
| 284 | For 20 km (25-20=45km) |
| 285 | INTERNAL ELECTRIFICATION |
| 286 | Concealed wiring in looping system with 2x1.5 mm² PVC insulated single core cable of 600V grade in heavy guage PVC pipe including occuping and fitting of elbows, bend, fees, junction boxes etc including required size of MS concealed boxes and front plate for housing of switches, sockets, fan regulator, bell push etc complete to light point. (a) Long point upto 10 mtrs |
| 287 | (b) Medium point upto 6 mtrs |
| 288 | (c) Short point upto 3 mtrs |
| 289 | Wiring as in item No.20 above to light plug point when fixed elsewhere with continous earth wire complete. |
| 290 | (a) Long point upto 10 mtrs |
| 291 | (b) Medium point upto 6 mtrs |
| 292 | Wiring as in item No.20 above to a Power Plug Point with 2x4 mm² including supplying and fitting of 15 Amp modular switch socket combined with continous earth wire to a Power Plug Point complete. |
| 293 | (a) Long point upto 10 mtrs |
| 294 | Wiring as in item No.20 above to a ceiling Fan/Exhaust fan point. |
| 295 | (a) Long point upto 10 mtrs |
| 296 | (b) Medium point upto 6 mtrs |
| 297 | Wiring as in item No.20 above to calling bell/bell indicator point. |
| 298 | (a) Long point upto 10 mtrs |
| 299 | Wiring as in item No.20 above for stair case/ Two way switch wiring. |
| 300 | (a) Long point upto 10 mtrs |
| 301 | Wiring as in item No.20 above for stair case/ Two way switch wiring. |
| 302 | (a) Long point upto 10 mtrs |
| 303 | Drawing of main and sub-main line wiring as in item No.20 above with VIR or PVC single core 250V Grade Cable. |
| 304 | (a) With 2x2.5 mm² copper wire |
| 305 | (b) With 2x4 mm² copper wire |
| 306 | Drawing of 3Phase Main Line 4 wire with DGSD approved VIR or PVC cable 660V grade in Heavy Guage 16SWG Rigid pipe Including with all necessary accessories. |
| 307 | (a) With 4x6 mm² conductor in MS Conduit. |
| 308 | Supplying, fittings & fixing complete Switch Fuse Unit(S.F.U) sheet Steel Re-wirable Main Switch with Pre-Fitted Fuse wire 50Hz. 240/415 V.(a) 3 Pole with Neutral (T.P.N) |
| 309 | (b) 100 Amp, 415 V Capacity. |
| 310 | Supplying & fixing of Load Kontaket Miniature Circuit Breakers DX3 MCBs for AC Application till 63A Single pole 240/410 V |
| 311 | (a) 0.5-6 Amp |
| 312 | (a) 6-32 Amp |
| 313 | (i) Triple Pole 415 V |
| 314 | (a) 6-32 Amp |
| 315 | Supplying, fitting & fixing of Distribution Board ETPN DB-VTPN for MCB, Isolator, RCCB and RCBO.A. IP 43- #1K 09 with metal door |
| 316 | (a) 4 Way 8+12 Module |
| 317 | (b) 6 Way 8+18 Module |
| 318 | Supplying, fitting & fixing complete brass bracket 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories.(a) Bulb |
| 319 | (i) 23 W |
| 320 | Supplying, fitting & fixing of LED PANEL LIGHTING surface or wall mounted with all necessary accessories.(a) 2x2 (595x595x65) mm LED luminaire |
| 321 | (i) 18W |
| 322 | (ii) 24W |
| 323 | (c) 2x2 (595x595x70) mm recess mounting luminaire suitable for ceiling. |
| 324 | (ii) 34W |
| 325 | Supplying , fixing, connecting, testing and commissioning of calling Bell/Bell indicator type suitable for 230V as well as battery operated with all necessary accessories. |
| 326 | (a) Dingdong Bell. |
| 327 | Supplying, fitting & fixing of exhaust fan double self lubricating type single phase 50Hz 250V AC operated complete with supporting frame, fan blades, nuts and bolts and other petty accessories as required.(a) Domestic Exhaust Fans |
| 328 | (iii) 250 mm |
| 329 | (v) Metal Exhaust Fan 300 mm |
| 330 | Supplying, fitting & fixing earthing with copper earth plate 600x600x6 mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe etc with charcoal, salts etc complete as required.(a) Copper earth plate electrode. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy