| 1 | Civil WorkDemolishing brickwork manually/ by mechanical meansincluding stacking of serviceable materials and disposal of unserviceable materials within 50m lead in cement mortar. |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 3 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. 12 mm average thickness. |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | Dismantling tile work of thickness 10mm to 25mm in floors/walls and roofs laid in cement mortar including stacking material as directed. |
| 6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes |
| 7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia Pipes |
| 8 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass swan neck pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass swan neck pillar tap |
| 9 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 10 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 11 | Dismantling MS rolling shutter, doors, windows and clerestory windows (steel or wood) shutter including chowkhats, guide rail architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres |
| 12 | Providing and fixing aluminium work for fixed portion withAnodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately). For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 13 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 14 | Removing white or colour wash, distemper, texture and acrylic paint by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 17 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. |
| 18 | Wall panelling / partition with Melamine faced 3 layered flat pressed wood particle board of approved make and brand as per direction of Engineer-in Charge of requisite grade bonded with phenol formaldehyde synthetic resin conforming to IS:848-1974(excluding the cost of supporting frame work and teak wood battens / lipping)In Ground Floor Plain : Conforming to IS: 3087 - 1985 Plain : Exterior grade. 9 mm thick |
| 19 | Electrical WorkWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit/casing, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required: Group C |
| 20 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 21 | Wiring for circuit / sub main wiring alongwith earthwire with the following sizes of FRLS PVC insulated, copper conductor, single core cable in surface / recessed medium class PVC conduit/casing as required. |
| 22 | 2 x 1.5 sq. mm.+ 1x 1.5 sq. mm earth wire |
| 23 | 2 x 2.5 sq. mm.+ 1x 2.5 sq. mm earth wire |
| 24 | 4 x 6 sq. mm.+ 2x 6 sq. mm earth wire |
| 25 | Installation of exhaust fan with making suitable size opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 26 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 27 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 28 | Supply of240V, 50HZ, 300 mm sweep, 900 rpm heavy duty Exhaust Fan, (Make- orient, Heavy Duty exhaust/equivalent). |
| 29 | Supply and fixing of 400 mm sweep, 230 Volt, white Aerodynamic blade and Hi-torque motor gives hi-air thrust wall mounted fan with Oscillation and speed control by pull cord system, connection, testing and commissioning etc. as required. (Wall 44 White of Orient or equivalent.) |
| 30 | SupplyingandfixingPressure die cast housing LED bulkhead with IP66 protection and IK09 impact resistance suitable for surface and wall mounting applications. light fittings complete with connection, testing and commissioning etc. asrequired. (WT202W LED10S CW PSU S3 PC of Philips or equivalent.) |
| 31 | SupplyandFixingofmountingrailforTLEDlamp luminarie, along with LED Lamp 20 W, Clamp,nut boltsand allaccessoriesfor fixing wallmounting,connection,testing, commissioningetcasrequired TMC502 2xT- LED 22W and Essential LED Tube 1200mm 20W865 T8 IND Iof Philips or equivalent.) |
| 32 | Supply and fixing of 1200 mm sweep, 230 Volt, 50 Hz, Brown colour, full copper motor and aluminium blades Ceiling mounted fan with suitable suspension rod, nut-bolt, connection with wire, testing and commissioning etc. as required. (RAPID AIR of Orient or equivalent). The job inclusive of dismentling of old ceiling. |