| 1 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete, of any description complete all as specified and directed. |
| 3 | Material and labour brick work with sub class \"B\"brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including all quoins, arches, pillars etc complete all as specified and directed. |
| 4 | Material and labour rendering 15mm thick on cement mortar 1:4 mixed with water proofing compound on fair/ unfair faces of brick/ concrete surfaces finished even and smooth without using extra cement with and including chicken wire mesh complete all as specified and directed.Note: WPC will be measured and paid separately under respective item of this schedule. |
| 5 | Supply only liquid water proofing compound (Dr Fixit or equivalent) @ 0.20 ml per bags of cement complete all as specified and directed. |
| 6 | Material and labour for applying exterior grade wall care putty 3 mm thick to (in two layers of 1.5 mm thick each) including rubbing surface of first layer to make the surface smooth including preparation of newly plastered surfaces complete all as specified and directed. |
| 7 | Material and labour for complete removal of existing treatment and applying two coats of exterior weather proof 100% anti fungal acrylic smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 6 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower including preparation of surfaces complete all as specified and directed. |
| 8 | Material and labour double charged vitrified ceramic coloured tiles 9-10 mm thick (square/rectangular) polished,area of each tiles exceeding 0.42 sqm and not exceeding 0.72 Sqm , in floor/wall etc. set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 including dismantling old tiles complete all as specified and directed. |
| 9 | Description all as per item No 8 here in above but as in skirting and over and including 10 mm thick rendering in cement mortar 1:4,complete all as specified and directed. |
| 10 | Providing and fixing in positon POP false ceiling flat/curved over GI metal frame work of applied quality and wiremesh as per description. The main GI frame (50x25mmx 24 gauge) shall be at 600mmx600mm c/c and intermediate frame (266mmx19mm x 24 Gauge) Shall be at 375mm C/C. The main GI member to be hanged with help of GI angle of 25mmx25x24 gauge and additional MS flats 25x3mm (Red oxide painted) and SS dash fasteners including all necessary work required expandal metal mesh (0.75Kg/Sqm) shall be firmly stretched and screwed to the intermediate frame with GI washer and average 20 mm plaster of paris to be applied on in two layers, Necessary provisoion & Making shall be made for cut outs for air conditions supply return air grills slits light fittings smoke detector and music speaker etc by providing 6 mm bwr ply templates. The job shall include making steps,ceiling vertical surfaces, cove in curvature & strainght pelment facia, recess for light, curved ceiling grooves etc as per detail in description including taking down old existing existing ceiling. The job shall also include hardwood frame required for fixing AC grill all as specified and directed. |
| 11 | Supply and fix in repair of decorative wall panelling with base frame of 50x25mm aluminium frame 600x600mmx16 gaugec/c fixed on wall with L-cleat and bothway screw etc. 12 mm ply on base frame with 4 mm decorative veneerof applied shed and melamine polish on veneer incl taking down old existingpanelling complete all as specified and directed |
| 12 | Excavating in trenches in any type of soil , n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out complete all as specified and directed. |
| 13 | Material and labour for cement concrete in 1;4:8 type D-2 (40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 14 | Material and labour for RCC M-25 Design mix{ using 20 mm graded stone aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc and mass concrete complete all as specified and directed. |
| 15 | Material and labour for RCC M-25 Design mix { using 20 mm graded stone aggregate) in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 16 | Material and labour for RCC M-25 Design mix { using 20 mm graded stone aggregate) in beams,cantilevers,wall bends, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 17 | Material and labour for RCC M-25 Design Mix (Using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 18 | Supply and fix mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (TMT) complete all as specified and directed. |
| 19 | Material and labour for TMT bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed. |
| 20 | Material and labour for use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 21 | Material and labour for use & waste of formwork to sides of pillers, posts, struts, piers, columns and stanchions etc for fair finished surfaces of concrete complete all as specified and directed. |
| 22 | Material and labour for use and waste for Formwork to sides and soffits of floor or roof beams, wall bend beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed. |
| 23 | Material and labour for use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. |
| 24 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 25 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting pointcomplete all as specified and directed. |
| 26 | Material and labour for aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter andone noswire gauged shutter sliding type, with aluminum sections as per Series-A(15mm) 3 track of Jindal section numbers for sliding windows,and glazed with tinted glass coloured glass 4mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum tower bolt 150mm long etc incl taking down old existing window complete all as specified and directed. Shutter Top & bottom size : 37.50x15x1.60mmShutter inner lock size 37.50x15x1.60 mm Shutter side (Handle) size 37.50x15x1.36mmChowkhat bottom size : 50.30x26x1.20mmChowkhat top & sides size:50.30x26x1.00mm |
| 27 | Supply and fixing of aluminum alloy powder coated door made out of hollow extruded aluminum section as mentioned below. Each door having 02 Nos Disc or D type handle, 02 Nos aluminum tower bolt 200 mm size, one brass mortice lock of six lever with key in duplicate regulated by double action hydraulic floor spring heavy duty (Make:- Sandhu/Ritz) shutter to be partly glaze with 5mm thick tined coloured glass in upper pannel and partly pannelled with 12mm thick both side laminated particle board in lower pannel fixed with glazing clip, rubber beading/gasket, anodised aluminum beading screw incl taking down old exisitng window complete all as specified and directed at site. Chowkhat Frame:- 101.60x44.45x1.60mmShutter verticle style :- 85x44.45x1.56mm Shutter middle Rail :- 83.50x44.45x1.54mmShutter Top Rail and bottom Rail :- 114.30x44.45x1.55mm |
| 28 | Supply and fixing in repair of SS grade 204 drapery rod 20mm diaincluding decorative brackets, decorative finals at both ends & curtain rings 8 Nos (Minimum) complete all as specified and directed. |
| 29 | Material and labour for concealed point wiring using approved colour coding as per IS, with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in non rigid PVC concealed conduit not less than 25mm diawith all fitting and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including Modular metal flush boxes 1.6 mm thick, upto 60 mm deep of required size factory made for mounting modular switch, regulators etc with inner /outer cover and frame(white) ISI marked, fixed with brass screwsincluding taking down unsv point wiringof any sizefor the following type . Note: (i)The quoted rates shall be deemed to be inclusive formaking good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. (ii) Point wiring & earth wire shall be connected to each & every sunken box. |
| 30 | One light point,controlled by one way switch, complete all as specified and directed. |
| 31 | One fan point, controlled by one way switch through regulator, complete all as specified and directed. |
| 32 | One three pin 5 Amp socket on same board with other switches, complete all as specified and directed. |
| 33 | One three pin 5 Amp socket on independent board, complete all as specified and directed. |
| 34 | Description all as per item No 29 here in before but point wiring with 4 sqmm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 4sqmm PVC insulated multi strand copper conductor cable as continous earth wire, complete all as specified and directed. |
| 35 | Supply and fixing of modular switch single pole one way, one module, 230 Volts 6 Amp complete all as specified and directed. |
| 36 | Supply and fixing of modular socket 6 Amps, 2/3 pin combined, two module, 230 Volts complete all as specified and directed. |
| 37 | Supply and fixing of modular switch single pole one way, one module, 230 Volts 16 Amp complete all as specified and directed. |
| 38 | Supply and fixing of modular socket 16 Amps, 2/3 pin combined, two module, 230 Volts complete all as specified and directed. |
| 39 | Supply and fixing of modular ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified and directed. |
| 40 | Supply and fixing of energy efficient LED tube light fittings 20 Watts, 230 volts with efficiency of not less than 100 lumens per watt, PC extruded body with PC diffuser including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 41 | Supply and fixing of round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and directed. |
| 42 | Supply and fixing of ceiling fans complete with blades, down rods, electronic regulator (min 100w), fan hook split type fabricated out of 12mm dia steel bar of length 30 cm duly painted with rod oxide old black paintand all accessories required to connection, 230 V, 1320 mm sweep, five star rated with brushless direct current motor (BLDC) all as specified and directed. Note : Old fan should be deposited to MES store |
| 43 | Supply and fixing of ceiling fans complete with blades, down rods, electronic regulator (min 100w), fan hook split type fabricated out of 12mm dia steel bar of length 30 cm duly painted with rod oxide old black paintand all accessories required to connection, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note : Old fan should be deposited to MES store. |
| 44 | Supply and fixing of sub main wiringwithPVC insulated unsheathed FRLSH cable 1100 Volt grade,with multi stranded copper conductor drawing in and including rigid PVC conduit in concealed / surface as required at site including one runPVC insulated unsheathedcable with multi stranded copper conductor colour code as a earth continuity and connected upto DBcomplete all as specified and directed including taking down old unsv submain wiring of following sizes .Note:(i)Tworun of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface withusing PVC rawl plugs etc.(iii) Phasecolour code must be follow i.ePhase( Red) and Neutral ( Black) In colour and for three Phase RYB For phase and black for neutral. |
| 45 | 2 x 6 Sqmm+ 1 x 6 sqmm, complete all as specified and directed. |
| 46 | 2 x 4Sqmm + 1 x 4 sqmm, complete all as specified and directed. |
| 47 | Supply, install,test and commisssioning reversible type (Hot and cool) split air conditioningunit, 1.5 Ton ,3 star, eco friendly refrigerant complete with drive motor, air cooled copper condenser with all accessories varied speed and dual rotary compressor, including fixing the out door units with mounting bracket , made Up of heavy duty GI steel, wall mounted type, Powder coatedincl nuts & bolt etcas per manufacture recomendation and fixing of room unit on wall , providing and making interconnection, including refregerent piping with nitryle rubber insulation and control cable from indoor to out door, first charging of refrigerent gas including cordless remote, complete all as specified and directed. |
| 48 | Supply and fixing of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stailized at 230V with accuracy of + 2.5% and of capacity 03KVA,complete all as specified and directed. |
| 49 | Supply and fixing of distribution boards epoxy powder coated TP & N (VTPN MCCB DB), 4 way, double door, fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall with suitable capacityfully insulated copper Bus Bar for each phaseand 02 neutralshrouded bar, 2 earth bar and cable tie for cable managementwith reversible door for IP-43 protection, 415 voltwith and including FP MCCB 100 Amps 25KA as incomer andcombination of SP/TP MCBs as outgoings and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing MCCB DB etc complete all as specified and directed. |
| 50 | Supply and fixing in replacement of MCB single pole240 volt, 10 KA, 6-32 Amp, \"B\" series confirming to IS including connection with suitable size copper lugs complete all as specified and directed. |
| 51 | Supply and fixing in replacement of MCB SPN 240 Volt 10 KA 40- 63 Amp \"B\" series conforming to ISincluding connection with suitable size copper lugs complete all as specified and directed. |
| 52 | Supply and fixing in replacementof distribution box MCB Protected socket with Plastic enclosure (Surface mounitng ) 20 AMP MCB Combo box DP including plug top including connection with suitable size copper lugs complete all as specified and directed. |
| 53 | Supply and fixing of distribution board SPN 8 Way with 100 amps, double door, IP 43 protection, for mounting MCBs isolator, ELCBs etc factory made, IS: 13032 marked with valid CM/L Nofabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossyfinished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing MCCB DB etc complete all as specified and directed. |
| 54 | Material and labour for laying, jointing and testing of undergroundXLPE insulated & PVC sheathed, armoured heavy duty multistranded electric cable with aluminium conductor, 1100 volts grade of size 25 Sqmm 4 core laid in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc and connecting with new aluminium lugs complete all as specified and directed.Notes:(a)Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately.(b)Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.(c)Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor. |
| 55 | Material and labour for sand cushioning for covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed. |
| 56 | Material & labour for sub class B bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as specified and directed. |
| 57 | Supply and laying of GI tubing medium grade (SI marked with all fittings and accessories for protection of cables on ploe/ wall or under road crossings including clamps, nuts, bolts etc of size 40 mm complete all as specified and directed. |
| 58 | Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with a 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00mm dia by means of bolts, nuts, Check nuts and washers of galvanised iron and thimbles and other end of the earth wire all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connecting to earthing test point & to main switch board andtesting on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board and protected by galvanized iron pipe medium 15 mm bore, and water pipe 20 mm bore GIlight grade with funnel and wire mesh, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4)type B-1 (using 20mm graded crushedstone aggregate) 75mm thick cover,reinforced with 8mm dia deformed or TMT bars 100mm C/Cboth way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed.NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item.(ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted.(iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost. |
| 59 | NOTE:- Amount of credit ofRs. 36937.00for retrieved materials is mentioned in Schedule of Credit Page No 23 of tender documents in pdf form which will be deducted offline while acceptance of tender. |