| Sl. No. | Item Description |
| 1 | Taking down existing old treatment incl padding water proofing plaster of any descriptionany type, roof tiles cement mortar screed bed and removing existing bitumen felt treatment incl brushing, brooming, cleaning top surfaces of roof slab to receive plaster etc incl disposing off debris from MoD land complete all as specified and directed. |
| 2 | Rendering 15mm thick cement plaster with cement mortar(1:3) with water proofing compound onfair finishes of brick work or concrete surface of roof slab, to be finished even and smooth(without using extra lime or cement ) all as specified and directed.( Water proof compound shall be measured and paid separately) |
| 3 | Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course: Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course :APP (Atactic Polypropylene) modified polymeric membrane, 5 layered,3 mm thick weight not less than 4.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @200ml/bag of cement and curved before laying of membarance.(c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions.(ii) Covered fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6).Note : (i) Roof treatment work shall be carried out through approved manufacturers only. |
| 4 | (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions.(ii) Covered fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6).Note : (i) Roof treatment work shall be carried out through approved manufacturers only. |
| 5 | Preparation of new or previously untreated surface of concrete or surfaces of any description and applying two coats of aluminium paint over roof surfaces over 10cm width or girth not otherwise described, all as specified and directed. |
| 6 | Dismantling of wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets GI framework complete all as specified and directed. |
| 7 | False ceiling grid galvanzed steel tee/ angle (Powder coated ) of grid size 600x600mmcomprising of main and secondry tee ( weight not less than 240gm /RM) and wall perimeter angle (weight of section not less than 217gm/RM) all around of walls suspended with 4mm GI wire @ 1200mm c/c of ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels insert of any type including 4mm thickdesigner ceiling boards size 595x595mm fixed in position all as directed. |
| 8 | Dismantling plain corrugated steel sheet of any gauge and thickness in roof coverings complete. |
| 9 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 10 | Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge of roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 11 | Dismantling timber scantlings (framed work) 40 Sqcm and over in section, in any position complete all as specified and as directed. |
| 12 | Dismantling timber scantlings (framed work) under 40 Sqcm in any position complete all as specified and as directed. |
| 13 | Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and as directed |
| 14 | Rolled mildsteel structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified. |
| 15 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc. |
| 16 | Walling of random rubble uncoursed, well bonded, bedded and solidly hearted built in CM 1:4 complete all as specified. |
| 17 | Ditto all asper item no 15 above but except stone set in CM 1:4 complete all specified and as directed |
| 18 | Taking down cement plaster of any description including raking outjoints, hacking for key, scrubbing down with water etccomplete all as specified and directed. |
| 19 | Rendering 15mm thick cement plaster with cement mortar(1:4) on fair faces of brickwork or concrete surfacesand finished even and smooth without using extra cement using water proofing compound.(WPC shall be measured and paid seperately) complete all as specified and directed. |
| 20 | Rendering 10mm thick cement plaster with cement mortar (1:6) on fair faces of brickwork or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed. |
| 21 | Rendering 05 mm thick in cement and sand mortar 1:3 on concrete roof surfaces including finishing the surface even and and smooth without extra cement ,complete all as specified and as directed. |
| 22 | GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste in repairs in patches n exc 5 sq. m each, including taking down old and jointing new to old as required all as spd and directed. |
| 23 | Applying 2mm thick wall care putty over newly plastered / old plastered surfaces of wall, complete all as specified and as directed. |
| 24 | Supply only Integral waterproofing compound. |
| 25 | Complete removal of existing treatment on walls all as specified and directed. |
| 26 | Preparation of newly plastered surfaces of walls andapplying two coats of oil bound distemper over a coat of chalk whitening primer complete all as specified and as directed. |
| 27 | Preparation of old plastered surfaces on wall and applying two coats of oil bound distemper completeall as specified and directed. |
| 28 | Preparatrion of newplastered and unplastered surfaces of walls and applying two coat of cement based paint over alkali resistant priming paint all as speicfied and directed. |
| 29 | Complete removal of existing treatment incl washing, rubbing down and stopping of old painted surfaces and applying two coats of cement base paint to walls complete all as specified and as directed. |
| 30 | Preparation of newly plastered surfaces of ceiling andapplying two coats of oil bound distemper over a coat of chalk whitening primer complete all as specified and as directed. |
| 31 | Preparation of old plastered surfaces on ceiling and applying two coats of oil bound distemper completeall as specified and directed. |
| 32 | Repair to balcony/Facia/Roof projections and soffit of chajjas etc by taking down old rendering and hacking clearly the edges and corners smooth rounded for new plastered area exceeding 30sqm in width or girth & providing 15 to 20mm thick plastering to match with the existing thickness in CM 1:3andincluding formwork up to height 7.0 mtr above ground level of bldg including two coats of Apex/cement based paint over one coat of primer complete all as specified. |
| 33 | Demolition of cement concrete(unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or aboveground level) complete all as specified and as directed. |
| 34 | 25 mm thick PCC 1:2:4 type B-1, (Using 20 mm graded crushed stone aggregate) as in chajja/balcony/landing work/kitchen etc of concrete topping even and rough as in levelling cousre complete all as specified. |
| 35 | Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for rough finished surfaces of concrete, complete all as specified and as directed. |
| 36 | 25 mm thick PCC 1:2:4 type B-1, (Using 20 mm graded crushed stone aggregate) as in flooring/padding, levelling,lintel beams,plinth beams cousre etc & finishing concrete topping even and rough,complete all as specified. |
| 37 | Formwork to sides and soffits/faccia of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including sup- ports, overhangs, etc. complete all as specified and directed. |
| 38 | TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and as directed. |
| 39 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises,complete all as specified. |
| 40 | PCC 1:2:4 type B-0, (using 12.5mm graded crushed stoneaggregate) 25mm thick as in subbase of floors complete all as specified and directed |
| 41 | 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 20mm thick screed bed in cement and sand mortar 1:4complete all as specified and as directed. Note:-(Size of Kota Stone slab shall not be less than 52 cm x 52 cm). |
| 42 | Machine cut kota stone slab flooring 20-25 mm thickas in riser of steps, skirting, dado and pillar, jointed and pointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete laid over & including 10 mm thick in CM 1:3 screedfor laying Kota Stone, complete all as specified and as directed. |
| 43 | 20 mm thick makrana white marble (table rubbed and polished ) as in border/cooking platform etc, bedded and jointed over15 mm thick screed in cement mortar 1:4including pointing in white cement 1:2 using marble dust including cutting and polishing complete all as specified and as directed. |
| 44 | Nonskid coloured ceramic tiles 7mm to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfacesincl 15mm thick screed bed/bedding layers in cement and sand mortar 1:4 all as specified and directed. |
| 45 | Glazed ceramic coloured tiles 300x450x7mm thick on vertical surfaces such as skirting, dados and rises to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10mm thick rendering in CM 1:4 finished even and fair to receive tiles, complete all as specified and directed. |
| 46 | Taking down chowkats or framesexceeding 1.5 Sqm and n.exc 4.00 sqm each with shutters (without taking off shutters from the frames) all as specified and directed. |
| 47 | Taking down chowkats or framesnot exceeding 1.5 Sqmwith shutters (without taking off shutters from the frames) all as specified and directed. |
| 48 | Pressed steel frames for doors with one or more rebates of size 125x60mm including necessary fixing lugs, hinges, lock strike plates complete, providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed. |
| 49 | Solid PVC (Door/almirah/cupboard) frames of size 50 x 47mm made out of 5mm dia plain colour PVC Sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing all as specified. |
| 50 | Factory made solid panel PVC door incl Almirah / Kitchen Cupboard / (wooden texture) shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colourPVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings.For payment purpose external area shall be measured . |
| 51 | Steel windows/ventilator (Box type) factory made with or without devetailed bar ( glass & glazed shutter) of size 79mmx39mm,16 gauge rectangular tubular frame withside hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh No 1/1 to 1/3 .Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid separately under respective item |
| 52 | Steel Windows/ventilator (Box type) factory made without glazing bars shuttersonlycomplete all as specified& as shown on drg No CEUZ/TD/1269/2008 Sh No 1/1/ to 1/3. |
| 53 | 35mm thick Flush shutters, solid core with particle board exterior grade as per IS-2202 of 1999 (Part-I).Flush door shutter shall be internally lipped as per clause 8.25.1 and 8.25.2 of SSR-2009 Part-I complete all asspecified and directed. |
| 54 | Glazed and skeleton shutters 35 mm thick second class hard wood, opened rebated and prepared to receive wire mesh etc, edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing witre mesh etc. Size of members of shutters as specified in SSR Part-I, Sec-8, clause 8.24(a), complete all asspecified and directed. |
| 55 | 300mm Mild steel ordinary rat tail rod pattern springs including roller and roller plate fixed, complete all as specified. |
| 56 | 100 mmbutt hinges, medium weight cold rolled mild steel, complete all asspecified. |
| 57 | Aluminium handle cast type anodised of size 150mm ;long ISI marked complete extruded |
| 58 | Aluminium anodised barrel tower bolt 150mm extruded section ISI marked complete. |
| 59 | 300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and as directed. |
| 60 | Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified. |
| 61 | Glazing with sheet glass 4mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed. |
| 62 | Figured glass sheet, 4.00mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed. |
| 63 | Floor door stopper 150mm overall length of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed at bottom rail of door all as specified and directed. |
| 64 | Curtain rail ,20 mm dia Stainless steel ,chromium platedfixed with CP bracket, incl taking down of old curtain rods, complete all as specified. |
| 65 | Preparation new steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed. |
| 66 | Preparation of old steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with one coat of synthetic enamel paint all as specified and directed. |
| 67 | Preparation of new untreated wood and wood based surfaces of any description over 10cm in width or girth not otherwise described and painting with two coats of synthetic enamel paint over a coat of pink primer,complete all as specified. |
| 68 | Providing cement concrete type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate), 50 mm thickas in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection. |
| 69 | Bituminous mastic filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight), complete all as specified and as directed. |
| 70 | Plain Cement Concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified and directed |
| 71 | Mild steel Framed work such as Water tank stand,Cooler stand(Incl fasteners for cooler stand) etc.with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290.Gde-E-165 |
| 72 | Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) 03 layered hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and as directed. |
| 73 | Taking up or down 20mm dia steel water tubiing and connections all as specified. |
| 74 | Taking up or down 15mm dia steel water tubiing and connections all as specified. |
| 75 | Mild steel galvanized steel tubing 20mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floorscomplete all as specified and directed. |
| 76 | Mild steel galvanized steel tubing 15mm bore medium grade with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 77 | 15 mm bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairscomplete all as specified and directed. |
| 78 | 20 mm bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairscomplete all as specified and directed. |
| 79 | Supply and fix in repair only ball valve high pressure PTMT with epoxy coated aluminium rod& high density plastic ball 20mm dia bore. |
| 80 | Vitreous china wash down water closet pan (pedestal pattern), (size 570mmx460mmx380mm), white (excluding fixing bolts, flushing cistern and flush pipe) with \"P\" or \"S\" trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. Complete fixed in repairs complete all as specified and directed. |
| 81 | Plastic water closet seat cover, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, including taking down of existing seat cover all as specified and directed. |
| 82 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.2 meter long flexible spirochrome flex tube and ABS wall hook including making connections and fixed in repair in position complete in all respect as specified.Make-Jaquar Cat part no. ALD-573 or its equivalent cat part of make specified in list make, as approved by GE. |
| 83 | Toilet paper holder with flap recessed type stainless steel Complete all as specified and directed.Make-Jaquar cat part no. AQN-7753 or its equivalent cat part of make specified in list make, as approved by GE. |
| 84 | PVC valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs complete all as specified and as directed. |
| 85 | Vitreous china wall hung wash basin with fixing accessories, white, flat back, size 550mm x 440mm x 185mm full pedestal including 15mm bore CP Central hole Basin Mixer with Popup waste system with 450mm long braided hoses for mixing hot and cold water screwed down for iron pipe including 32mm dia waste coupling,waste pipe, cutting for and pinning in ends of brackets or erecting standporcelain stopper a pair of CI brackets fixed in repair complete all as specified and directed by Engineer in charge.Make-Jaquar Queens prime cat part no.QQP7169BPM or its equivalent cat part of make specified in list make, as approved by GE. |
| 86 | Vitreous china wash basin, white, flat back, size 550x400mm including waste fitting chromium plated brass, pillar tap, chromium plated steel chain and rubber plug, porcelain stopper, a pair of CI brackets, waste pipe etc., fixed in repairs complete all as specified and as directed.Cat Part No-10086 of Hindware for Wash basin or its equivalent cat part of make specified in list make as approved by GE. |
| 87 | Vitreous China urinal with CP spreader Chrome finish hole and fixing accessories Half stall type (back or corner wall type)(size 355mm x 340mm x535mm) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; including PVC Connection,waste pipe and coupling. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) fixed in repairs including Urinal partion White colour 310x700 mm of marble complete all as specified and as directed andapproved by GE. |
| 88 | Supply & fixing in repair Chromium plate Stainless Steel towel rail 60cm long including brackets, complete all as specified and directed. |
| 89 | Towel ring of brass chromium plated fixed with and including chromium plated brass screws and wooden/plastic cleats etc fixed in repair, complete all as specified. |
| 90 | PVC connection 15mm size of length 600mm, with PTMT nuts supplied and fixed in repairs complete all as specified and as directed |
| 91 | CP angle valve/concealed stop cock of cast copper alloy (ISI Marked) chromium plated fancy type scrwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore incl add if fixed in repairs complete all as specified and directed. |
| 92 | 15mm bore brass CP wall mixer with provision for overhead shower arrangement with 115mm long bend pipe on upper side for mixing hot and cold water supply screwed down with connecting legs CP extension nipple & wall flange connector for hand shower arrangement with connecting Legs, wall Flanges & wall bracket for hand shower for mixing hot or cold water, screwed for iron pipe and fixed in repairs, complete all as specified and directed. |
| 93 | Bib taps (Long body) for 15mm bore dia of pipe, fancy type chromium platedwith crutch or butterfly handle, screwed down for iron pipe or for brass ferrule and fixed in repairs complete all as specified and directed.Cat Part No-CON-107KN of Jaquar or its equivalent cat part of make specified in list make, as approved by GE. |
| 94 | Brass chromium plated shower roses 125mm with or without swivel joints, including fixing to steel pipe or union fixed in repairs all as specified and directed. |
| 95 | CP grating with or without hole100 mm dia fixed in repairs all as specified and as directed. |
| 96 | Stainless steel Soap dish, any type, fixed with plugs chromium plated brass screws fixed in repairs complete all as specified and as directed.Cat part No-AQN-7733 of Jaquar or its equivalent cat part of make specified in list make, as approved by GE. |
| 97 | 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC Sheet 0r 6mm thick commercial plywood fixed to wdn plugs with CP Brass screws and cup washers fixed in repairs, completeall as specified and as directed. |
| 98 | Glass shelf assembly fixed in repair all as specified and as directed. |
| 99 | Stainless steel peg set of six hooks with base plate and fixed to wall/door and including rawal plug and stainless steel screws all as specified and directed |
| 100 | Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern ), includding all fittings, heads , shoes bends , swan-necks etc . complete all as specified. |
| 101 | 110mm bore PVC SWR Type-B ( pressure not less than 6 kg /cm2) pipes single socket in any length with rubber ring joints fixed to wall etc., complete all as specified and directed. |
| 102 | 75mm bore PVC SWR Type-B ( pressure not less than 6 kg /cm2) pipes single socket in any length with rubber ring joints fixed to wall etc., complete all as specified and directed. |
| 103 | PVC (SWR) bends any radius 110mm dia with oval access doors fixed in repairs complete all as specified and directed. |
| 104 | PVC (SWR) bends any radius 75mm dia with oval access doors fixed in repairs complete all as specified and directed. |
| 105 | PVC SWR 110mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed. |
| 106 | PVC SWR 75mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed. |
| 107 | PVC (SWR)110 mmjunction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch with oval access door fixed in repairs all as specified and as directed. |
| 108 | PVC junction, double (double Y), equal or unequal, ordinary or inverted with spigot or socket branch of 75mm bore with access door, complete all asspecified and directed. |
| 109 | PVC cowls 110mm fixed in repairs complete all as specified and directed. |
| 110 | PVC cowls 75mm fixed in repairs complete all as specified and directed. |
| 111 | PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 112 | Providing 75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggragate )as in plinth protection all as specified. |
| 113 | Chequered cement concrete tiles 30cmx30cmx25mm thick laid & jointed with grey cement and pointed in neat cement slurry in floors 20 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes all as specified and directed. |
| 114 | Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 115 | Machine pressed concrete interlocking paver block any shape, size and colour confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment over sand cushion complete all as specified and directed.Note:- Sand cushioning shall be measured & paid seperately. |
| 116 | PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate), in roof kerbs or mud stops, filling in electric pole installation, protection for interlocking paver blocks,rounded or chamfered angles and edges, including necessary form work complete all as specified and directed. |
| 117 | Excavation in trenches not exceeding1.5 m wideand not exceeding 1.5 m deep for laying cable including gettingout in any type of soil complete all as specified and directed. |
| 118 | PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified. |
| 119 | Demolition and breaking up drain pipe 150mm dia (salt glazed ware, AC, PVC or reinforcement concrete) set in cement mortar/concrete complete all as specified. |
| 120 | Concrete bed in PCC 1:3:6 type-C-2 (using 40mm graded crushed stone aggregate) to drain pipe 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 121 | RCC classNP3 150mm dia drain pipes laid in trenches and jointed with & including coller complete all as specified and directed. |
| 122 | Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified. |
| 123 | PCC 1:2:4, B-1 (20mm graded crushed stone aggregate) as in copings, hold fasts, plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified. |
| 124 | Rendering 15mm thick cement plaster with cement mortar(1:4) on fair faces of brick work or concrete surfacesand finished the surface even and smooth without using extra cement, complete all as specified. |
| 125 | Mild steel works of flat iron, square bar, round bars etc. as in framed work such as grills, guard bars, gratings etc incl bending, cutting and welding as necessary ofconfirming to Gde Fe 310-0 fixed in repairs completeall as specified. |
| 126 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed. |
| 127 | Removing surplus soilto distance not exceeding50 m and depositing where directed at a level notexceeding 1.5 m above the starting pointcomplete all asspecifiedand directed . |
| 128 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 150mm, complete all as specified & directed. |
| 129 | PCC 1:3:6 type-C-1 (using 20mm graded crushed stone aggregate) as in surface channeland drains complete all as specified and as directed |
| 130 | PCC 1:2:4 type B0 using (12.5 mm graded crushed stone aggregate )as in parapet, coping etc including necessary form work all as specified and directed |
| 131 | Extra for forming fair finished to drain channel not exc 30 cm inner girth in cement concrete using extra cement complete all as specified and directed. |
| 132 | Ditto all as per srl item 132here-in-before but for each 25 mm in girth or part there of over or under 30 cm all as specified and directed. |
| 133 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified anddirected. |
| 134 | Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCcasing and copping of suitable size andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 1.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:-(Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washersshall be deemed in to included in quoted rate only.) |
| 135 | one light point/fan point controlled by one switch |
| 136 | One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . |
| 137 | One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . |
| 138 | Materialand labour for point wiring complete with 2.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCcasing and copping of suitable sizeandincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 2.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:- |
| 139 | Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers shall be deemed in to included in quoted rate only. |
| 140 | Ditto asin srlitem no 134 but one 15 amp power socket outlet point controlled by one 16 amp witch on independent board |
| 141 | Modular type switch 6 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and approved. |
| 142 | Modular type switch 16 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and approved. |
| 143 | Modular type socket shuttered type 6 Amps- 2/3 Pin combined 2 module,240V,ACISI Marked Complete all as specified and directed. |
| 144 | Modular type socket 6 A/16 Amps -2/3 Pin combined shuttered socket 2 module 240V ACISI MarkedComplete all as specified and directed Make Crabtree, Havellsor equivalent of makes as specified in the list of makes |
| 145 | Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 146 | Fan regulator modular type electronic compatible with BLDC fan, stepped type 100 Watts, 2 module 240Volts, AC ISI marked complete all as specified and directed. |
| 147 | LED light fitting 1x20W, 220V, Integrated surface mounted box type with aluminium housing integral electronic driver LED fitting light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete as in repairs as approved by GE all as specified and directed. |
| 148 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V Integrated surface mounted box type with aluminium housing integral electronic driver LED fitting including connecting up with three core flexible copper conductor cable of suitable size complete incl testing after fixing in repairs as approved by GE all as specified and directed. |
| 149 | LED light fitting 1x10W, 220V, Bulk head luminaries including LED driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 150 | Supply & fixing and in repair sheet metal enclosure acrylic door 240 volts AC,SPNdistribution board8 wayfor flush mounting with 200 amps copper busbar,neutral bar,earth barand MCB incomer of rating upto 200Amps ,MCB SPN/DP,and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate withIP 36 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coatall as specified and as directed. |
| 151 | Supply & fixing and in repair sheet metal enclosure acrylic door 240 volts AC,SPNdistribution board6 wayfor flush mounting with 100amps copper busbar and including making good the disturbed surfaces to match with existing surface and colour coatall as specified and as directed. |
| 152 | MCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed. |
| 153 | MCB single pole & neutral 40 to 63 amps 240 volts 10 KA \"C\" series fixed in repair, complete all as specified. |
| 154 | Ceiling fans complete with blades, down rods, and accessories, 230 volt, 1200mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) including taking down old unsv fan, complete all as specified and directed. Make:- Cat Part No Zinger of Make Havells or its Equivalent cat part of make-BAJAJ,CROMPTON GREAVES, GEC, KHAITAN,ORIENT as approved by GE.[Note: Old U/s ceiling fans shall be deposited into the MES store yard] |
| 155 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground leel, connecting to the Galvanised earthing lead strip 32x6mm size, by means of bolts, nuts, heck nuts and washers of galvanized iron andearth lead protected by provision of GI medium grade pipe 65mm bore incl provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape GI medium grade 40mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 17mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs, all as per electrical plate No 5 of SSR-1991 Part I and connected to earth test point all as specified or indicated incl testing on completion. |
| 156 | Supply and fixing in replacementelectric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed. Make Godrej/Havells(Monza EC),or equivalentNote:-NOTE: Old Unserviceable geysers shall be deposited to MES store yard. |
| 157 | S&F in repair GI water tubing in replacement 40mm bore \"medium grade\", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed. |
| 158 | S&F in repair GI water tubing in replacement25mm bore \"medium grade\", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed. |
| 159 | S&F in repair GI water tubing in replacement20 mm bore \"medium grade\", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed. |
| 160 | Cutting & screwing of pipe line of 80mm dia for branch connection alongwith insertion of suitable elbow/union/nipple 40mm dia and connecting material such as joints, nuts, bolts etc complete all as specified and as directed. |
| 161 | 25 mm bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairscomplete all as specified and directed. |
| 162 | 40 mm bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairscomplete all as specified and directed. |
| 163 | Construction of brick masonary valve pit of size 90cm x 90cm x 90cm (Internal dimensions of chamber from top of PCC to bottom of cover) including excavation in any type of soil returning, filling around foundation and removal of surplus soil to a distance not exceeding 50m PCC 1:4:8 type D-2 in foundation brick work in cement mortar 1:6, 10mm thick plaster in cement mortar 1:4 to internal surface covered pit with MS sheet cover 3.15 mm thick with locking arrangement, handle fixing arrangement fixed on 40mm PCC 1:2:4 type B-1 coping and painting with oil paint two coat over a coat of red oxide primer complete all as specified and directed. |
| 164 | Supply laying & testing ofXLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade of size 16 Sqmm nominal cross section x 2 core, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointingwith suitable size aluminium lugs complete all as specified. |
| 165 | Supply laying & testing ofXLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade of size 10 Sqmm nominal cross section x 2 core, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointingwith suitable size aluminium lugs complete all as specified. |
| 166 | Sand cushioning to under ground cable, 8 cms thick before laying the cable and 15 cms thick after laying and stretching the cable in trenches including hand punning and consolidating, punned to 18cm thickness, complete all as specified and directed. Note : For payment purpose, only punned thickness shall be measured. |
| 167 | Supply Installlaion and testing of silent Diesel engine driven generating set of capacity58.5 KVA,liquid cooled, as per latestCPCB Norms Developing 74 BHP @1500 rpm engine directly coupled with 58.5 KVA alternator rated at 415 volts , 3 phase 4 wire, 50 HZ and 0.8 pf both mounted and aligned on common base frame complete with inbuilt MS fuel tank ,residential exhaust silencer,AVM pad fitted on base frame ,01 nos battery of suitablecapacity for 12 volts operating system and integrated operating panel with feature of autostart and stop with sound proof canopy all housed in acoustic enclosure and standard AMF control pannel with control wiring as per company design complete and PCC Foundation of suitable size as per site requirment designed by the manufacturer all as Specified and directed including the following: |
| 168 | PRIME MOVER.Vertical diesel engine of suitable capacity having suitable BHP water cooled, closed circuit as per BS-649 or IS-10002The DG set shall be capable of running 24 hrs continouslywith 10% overloading for one hour in every 12 hours as per BS-5514/BS-649. Engine shall be equipped with all standard fitting as per manufacture\"srecomendations and mounted on common base frame with following fittings. |
| 169 | RPM cum hour meter |
| 170 | Battery charging ammeter |
| 171 | Ignition key and starting with push button switch. |
| 172 | Lubrication oil pressure gauge. |
| 173 | Electronic Governor controlling. |
| 174 | Oil temp. gauge |
| 175 | Safety control (Trip) for the following:- |
| 176 | Low lubricating oil pressure Over speed. |
| 177 | Lub oil coolant heater to avoid freezing |
| 178 | 24 volts starting equipment compresing of all followings:- |
| 179 | 02 No 12 volts 180 AH battery. |
| 180 | Make:Exide /Standard/Amaron |
| 181 | Battery charging alternator with inbuilt regulator |
| 182 | Starter motor of suitable capacity . |
| 183 | Battery leads (copper cable) of suitable size with terminal. |
| 184 | Make of engine: Kirloskar/ Cummins/ crompton Greaves Ltd.,Mahindra & Mahindra |
| 185 | ALTERNATOR:- Alternator rating58.5 KVA, 3 phase, 50 cycles 415 Volt, 4 wire supply at0.8 power factor running @1500 RPM, self excited self regulated, mountedon a strong fabricated steel frame, suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be conforming to BS-2613 or IS-4722. |
| 186 | Make: Kirloskar/ Crompton Greaves/Stamford/ Cumins |
| 187 | CONTROL AMF PANEL:- Alternator control panel floor mounted cubical type with internal copper wiring for 58.5 KVA alternator, 415 volts, 3 phase 4 wire, 50 cycles fabricated outof 1.6mm thick MS Steel, painted externally with two coats of synthetic enamel paintover one coat of primer including following accessories:- |
| 188 | suitable scale flush mounted AC voltmeter with selector switch 0-500 volts : 1 set |
| 189 | Suitable scale flush mounted ammeter wioth selector switch and CT\"sof suitable range : 1 set |
| 190 | frequency meter: 01 No |
| 191 | KWH meter: 01 No |
| 192 | MCCB Suitable range- 01 No. (forincoming) as recommmended by manufacturer |
| 193 | Set of aluminum bus bar of suitable capacity. |
| 194 | OTHER FITTINGS :- |
| 195 | Fuel Tank :MS fuel tank of suitable capacity as per manufacture\"s instructions capable to store fuelfor 12 hours running of DG set including oil level indicating guage, drain & air vent plug etc. |
| 196 | Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed. |
| 197 | Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 70 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 198 | Earthing complete with galvanised steel earth plate elcrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground) with top edge of plate not less than 1.5m below normal ground level connecting to the GI earthing strip 25x4 mm by means of bolts, nuts check nuts and washers of galvanised iron and GI Strip 25x4 mm protected by provision of GI Light grade pipe of 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregrate with 40mm thick cover of RCC (1:2:4) raniforced with XPM (weight not less than 4Kg/sqm) and frame of angle iron 25x25x6mm with lugs 02 nos and 6mm dia MS bars handle made to shape, GI Light grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge for earth plate incl common salt and charcoal filling, test point made out of 75x50x6mm phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50m all as per electrical plate no 3 of SSR 1991 Pt-I and connecting to earh test point incl testing on completion. |
| 199 | Note:-The required resistance of Earthing shall be less than 2 ohm, If not fouund to the required resisstance, the contractor has to re earthingfor required resistance andthe cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance. |
| 200 | On load change over switch, 4 pole, capacity 200 Amp with SS enclosure complete including fixing in replacement on wall, open execution type with necessary fixing arrangement complete all as specified and directed. |