| 1 | 16-12-2025 | Corrigendum1 | BOQ | 01-01-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling/Taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and leveled as directed by Engr-in -charge. |
| 2 | Material and labour for rendering 10mm thick on concrete surface ,in cement mortar 1:4,mixed with liquid water proofing compound, finished even and smooth without using extra cement complete all as specified and as directed(for over roof slabs) (Note :- Water proofing compound shall be measured and paid separately) |
| 3 | Material and labour forproviding and applying Fiber reinforced elastomeric liquid applied water proofing membrane, formulated with PU hybrid polymers and reinforcing acrylics fibers and can bear upto 10 bar hydrostatic pressure by using Asian paintssmart care damp prrof ultra or equivalent having SUN REFLECTING INDEX (SRI) of 106.59 on top of concrete roof in three coats @10 L/10sqm. One coat of self priming of elastomeric water proofing liquids (dilution with water in the ratio of 3:1 ) and second coat of undiluted elastomeric water proofing liquid, followed by third final coat ofundiluted elastomeric water proofing liquid ( dry film thickness of complete application/system not less than 200 microns) with water proofing warranty of 10 years. Prior to all this activity surface preparation to be done by removing dust, algae, fungus, oil, grease etc and crack filling by Smart care textured crack filler wherever required. On tile mosaic surface use Smartcare terrace tile primer for better adhesion. The item rate is inclusive of all material with wastage, labours, tools, tackles, consumables, scaffoldings etc |
| 4 | Providing and applying Fiber reinforced elastomeric liquid applied water proofing membrane, formulated with PU hybrid polymers and reinforcing acrylics fibers and can bear up to 10 bar hydrostatic pressure by using Asian paints smart care damp proof ultra or equivalent having SUN REFLECTING INDEX (SRI) of 106.59 on top of concrete roof in three coats @10 L/10sqm. One coat of self priming of elastomeric water proofing liquids (dilution with water in the ratio of 3:1 ) and second coat of undiluted elastomeric water proofing liquid, followed by third final coat ofundiluted elastomeric water proofing liquid ( dry film thickness of complete application/system not less than 200 microns) with water proofing warranty of 10 years. Prior to all this activity surface preparation to be done by removing dust, algae, fungus, oil, grease etc and crack filling by Smart care textured crack filler wherever required. On tile mosaic surface use Smart care terrace tile primer for better adhesion. The item rate is inclusive of all material with wastage, labors, tools, tackles, consumables, scaffoldings etc. |
| 5 | Demolition of concrete(reinforced)of any description and in any position not otherwise specifically provided for |
| 6 | Demolition ofroofs, floors(other than ground floors) beams, staircase ,landing , chajjas and similar suspended work |
| 7 | Demolition of precast block masonry built in cement mortar including all quoins, arches, pillars etc but including ashlars facings, dressed stone work including removal of rubbish complete. |
| 8 | Material and labour for Pre-cast cement concrete block masonry of 1:3:6 type C-1 with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete all as specified and as directed |
| 9 | Material and labour for 10mm thick plaster in CM (1:4)finished to even & smooth w/o using extra cement complete all as specified and as directed |
| 10 | Material and labour for RCC Type B1 1:2:4 (using 20mm graded stone aggregate) as in slab supported on walls, beams, columns in floors, deck slabs and in shelves etc complete all as specified and as directed |
| 11 | Material and labour for RCC nominal mix in Type B1 1:2:4 (using 20mm graded stone aggregate) as in slab supported on walls, beams andcolumns in floors, roofs, landing , balconies, canopies, deck slabs and in shelves etc complete all as specified and as directed |
| 12 | Demolition of stone slab and tiles of any description or thickness in floors, aprons etc (laid, bedded and pointed in any mortar) all as specified. |
| 13 | Material and labour for 18-20mm thick granite work (table rubbed and polished) (colour as approved by GE) in steps, jambs, pillars, window cills, cooking platforms and like in CM(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including screed bed or bedding layerof CM 1:4, 20mm thickcomplete all as specified and as directed |
| 14 | Material and labour for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surface of concrete flat complete all as specified and as directed |
| 15 | Material and labour for Precast cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and jointed in cement mortar 1:6 complete all as specified and as directed |
| 16 | Material and labour for Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding |
| 17 | Material and labour for machine cut Kota stone slab 20-25 mm as in window cills, flooring etc laid over cement screed bed jointed with grey cement slurry mixed with pigment to match the shade the slab including rubbing and polishing complete all as specified and as directed. |
| 18 | Material and labour for machine cut Kota stone slab 20-25 mm as inin riser of steps, skirting, dado and pillar etc laid over cement screed bed jointed with grey cement slurry mixed with pigment to match the shade the slab including rubbing and polishing complete all as specified and as directed. |
| 19 | Demolition of concrete in ground floor and paving n.exc 15 cm thickness (below or above ground) |
| 20 | Material and labour for 75 mm thick PCC 1:3:6 type C-2 as in sub base Floor Paving Plinth Protection finished even and fair complete all as specified |
| 21 | Material and labour for Cement concrete C2 1:3:6 ,40mm graded aggregate in surface channels and drains complete all as specified |
| 22 | Material and labour for PCC 1:2:4 type B0 using 20 mm graded aggregate ,25mm thick as in leveling sub base and all as specified and directed. |
| 23 | Taking down cement plastering of any description on brick or stone wall etcincluding rakingout joints hacking for key scrubbing down with water etc and removal of debris and depositing where directed. |
| 24 | Providing 10mm thick plaster in CM (1:6)finished to even & smooth w/o using extra cement. |
| 25 | Providing 05 mm thick plaster in CM (1:3)finished to even & smooth w/o using extra cement on ceiling. |
| 26 | Material and labour for Providing and applying 15mm CM (1:4) thick ready mix external sand faced cement plaster with neat cement rendering at all locations in two coats of masonry (except stone masonry) and concrete surfaces including providing water proofing compound to the first coat of plaster as per manufacturers specification, including racking out joints, hacking of concrete surface, finishing, curing, and necessary scaffolding etc complete. |
| 27 | Material and labour for Preparation of new surface of wall by scrapping / rubbing, applying two coats of Advanced Anti-algal Weather Proof 100% Acrylic smooth emulsion with silicon additives, over a coat of fibre reinforced elastomeric liquid water proofing membrane. complete as per Manufacturer specifications |
| 28 | Material and labour for taking down loose and damage concrete cement plaster from soffits of ceiling, floor/ slab, vertical surfaces of columns, beams, slabs etc examine concrete by tapping with light hammer and marking of the loose concrete areas of structural elements in straight line geometrical forms, grooving the edges same with grinder up to 5-10mm depth without damaging existing rebars, carefully removing carbonated concrete around the rebars up to 10mm depth by low impact high frequency hammer/ chipper without damaging the sound concrete including exposing and removing rust from reinforcement by rubbing with wire brush and plenty of water so as to remove the loose particles, dust, laitance etc and removal of debris to a distance n.exc 50m and deposited where directed all as specified and as directed. |
| 29 | Material and labour for Preparation of surface by application of rust remover as exposed reinforcement using rust remover of approved make apply passivator coatusing zinc primer/ anti corrosive paint of approved make on reinforcement bar andproviding and applying jacketing around columns/beams with micro concrete including all lifts, shuttering, drilling holes and fixing shear anchor all as specified and as directed.(i) Reinforcement shall be measured and paid separately(ii) Rates including jacketing, formwork, scaffolding and all structural repairing procedure and micro concrete |
| 30 | Material and labour for Injecting low viscosity high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including mixing of materials, mixing of material components (part a & b) in the required quantities as per manufacturer\"s instruction by weigh batching.Grouting maintain the pressure at exit (0.5 to 1.0 kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements @ 100ml per nozzle.Repeat the process for all the nozzles, (Beam and columns) all as specified and as directed. |
| 31 | Material and labour for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes in structural members at the intervals of 500 center to center in staggered manner or as directed by Engr-in-charge in RCC structural element.Work shall be carried out as under:-(i) Cleaning of holes.Clean the holes by air blower prior to fixing nozzles.(ii)Fixing of nozzles.Insert 12mm dia, Rohibb Teflon nozzles in cleaned holes.External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing.Cure the system for min 12 hrs(iii)Cutting of nozzles.Cut the nozzles by chisel after completion of grouting without damaging structural elements. |
| 32 | Material and labour for preparation of surface by application of rust remover on exposed reinforcement usingrust remover of approved make, apply passivator coat using zinc primer /anti corrosive paint of approved make on reinforcement Bars.Apply bond coat using \"Epoxy bonding agent\" on entire surface, when bond coat becomes tacky apply repair mortar (using universal polymerized repair mortars single pack like Pagel U40 or Micro concrete) in layers of 15mm and subsequently built up the required thickness (45mm) in subsequent layers of 15mm and finishing the final layer even and smooth as per manufacturers instruction and as directed. Note: Application to be done by authorised applicators only. RATE of shuttering and formwork is included |
| 33 | Supply only welded steel wire fabric weight n exc 4 kg per sqm all as specified and as directed. |
| 34 | Material and labour for preparation of new CEILING surfaceand applying two coat of oil bond distemperover a coat of alkali resistant primer and preparation of the surfaces complete all as specified and directed |
| 35 | Complete removal of existence treatment of oldwall andapplying a layer of 3mm thickwall care putty in two coat on wall and applying two coat of oil bond distemperover a coat of alkali resistant primer complete all as specified and directed |
| 36 | Complete removal of existence treatment of ceiling andapplying two coat of oil bond distemper over a coat of alkali resistant primer complete all as specified and directed |
| 37 | Preparing newly plastered surfaces of wall and applying two coats of Oil bound distemperover a coat of alkali resistant primer over 3mm thick wall care putty complete all as specified and directed |
| 38 | Supply liquid water proofing compound |
| 39 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises. |
| 40 | Rendering 10mm thick cm 1:4 on fair faces of stone masonry wall surfaces, finished even and fair to receive glazed tiles complete all as specified and directed |
| 41 | Material and labour for 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor tiles complete all as specified and directed |
| 42 | Supply and fix glazed ceramic tiles 450 x 300 x 7mm thick coloured on vertical surfaces such as dado skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed |
| 43 | Supply and fix Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed |
| 44 | Supply and fix Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed |
| 45 | Supply and fix Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n exc 0.38 sqm, in vertical surfaces of skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed |
| 46 | Taking down chowkat/frame with shuttersexc 1.5 Sqm but n exc 4 Sqm each with shutters (without taking off shutters from the frame) |
| 47 | Material and labour for 2nd class hard wood for Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed |
| 48 | Taking down chowkat/frame with shuttersnexc 1.5 Sqm with shutters (without taking off shutters from the frame) |
| 49 | Taking down shutters exe 1 sqm but nexc 2 Sqm with shutters (without taking off shutters from the frame) |
| 50 | Cutting holes in brick walls built in cement mortar for inserting hold fast etc depth of embedded portion of hold fasts exc half brick but n exc one brick thick wall and making good to the dismantled portion in cement mortar 1:3 and providing cement concrete 1:2:4 type B1 for concreting of hold fasts. |
| 51 | Supply and fix Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkat of size 65x 125 mm comprising of virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directedNote: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. SS dash fastener of size 10mm dia and 150mm length at 500 center to center spacing with minimum 3 no in one vertical face.Gap between frame and wall to be filled with silicon sealant |
| 52 | All as per item No. 51 but 30mm thickwire gauzed i.e. panel will be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly complete all as specified and directed |
| 53 | Material and labour for 2nd class hardwood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. complete all as specified and directed |
| 54 | Supply and fix35mm thick (Factory made) 2nd class hardwoodplain framed, paneled shutter (two or three panel) with lock rail and panel of 9 mm BWP commercial ply or 12mm veneered particle board with commercial veneering onboth faces. The size of rail and stileas per IS 1003 (Part -I) kilnseasoned and chemically pressure treated. complete all as specified and directed |
| 55 | Supply and fix Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge)minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flam of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed(Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 56 | Supply and fix mild steel works as in bands, straps, clamps hold fasts and similar small articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed. |
| 57 | Material and labour for providing plain cement concrete 1:2:4, type B-1 (using20 mm graded stone aggregate) as in bed blocks for hold fasts, roof kerbs or mud stops, rounded or chamfered on edgesetc, including weathering, slightly rounded or chamfered angles and throatingcomplete all as specified and directed |
| 58 | Material and labour for preparation of new surface of wood or wood based material over 10 mm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified. |
| 59 | Material and labour for preparation of old surface of wood or wood based material over 10 mm width or girth and applying one coats of synthetic enamel paintcomplete all as specified. |
| 60 | Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm prelaminated PVC sheet reinforced with MS square tube, fixed in position as directed. |
| 61 | Supply and fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with prelaminated colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelaminated sheet PVC sheets for top rail, lock rain & bottom rail paneling of plain gap insert for top rail & bottom rail paneling of prelaminated PVC sheet 10mm to be fitted in the MS frame sledded/sealed to the stiles & rails (stiles and rails feathered at edge) with suitable PVC sheet beading and jointed together with solvent cement supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed |
| 62 | Supply and fix aluminium anodisedbarrel tower bolts of extruded section 150 mm long complete all as specified and directed |
| 63 | Supply and fix Aluminium alloy anodised sliding door bolt 300 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy. |
| 64 | Supply and fix stainless steel Butt hinge 100mm size. |
| 65 | Supply and fix extruded anodised aluminium alloy, fabricated type handle, 150mm long |
| 66 | Supply and fixfloor door stopper of aluminium alloy body with rubber shoe 75mm long .. |
| 67 | Supply and fix Aluminium alloy wire cloth 0.45mm nominal dia of wire and avg width of aperture 1.4mm cut to size and fixed to doors/window shutters and fixed with aluminium wire staples as ordered. |
| 68 | Supply and fix in repair Aluminium alloy wire cloth 0.45mm nominal dia of wire and avg width of aperture 1.4mm cut to size and fixed to doors/window shutters and fixed with aluminium wire staples as ordered. |
| 69 | Supply and fix mild steel works as in bands, straps, clamps hold fasts and similar small articles conforming to Fe 410-0 or Fe 310-0 |
| 70 | Supply and fix Vitreous china water closet European type with water closet and including fixing in repair with P trap all complete as specified. |
| 71 | Supply and fixplastic water closet seat cover for EWC, white closed pattern with flat bottom,and cover and mild steel chromium plated or aluminised hinging device |
| 72 | Supply and fix health faucet(ABS body)mild steel CP suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connection and fixedin position complete in all respect |
| 73 | Supply and fix PVC low/high level flushing cistern, 10 Ltrs capacity including float valve, chain, PVC flush pipe. |
| 74 | Supply and fix grating doom 125mm dia with waste holes of PTMT( Min wt 40 gms). |
| 75 | Supply and fix PVC connections, 450mm long with brass CP/PTMT nuts suitable for connecting 15mm bore pipes, superior quality fixed in repairs. |
| 76 | Taking up or down steel water tubing 15mm bore and connections |
| 77 | Taking up or down steel water tubing 20mm bore pipe and connections . |
| 78 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10cm girth in stone concrete block or slab walls complete all as specified and directed. |
| 79 | Supplying & laying CPVC water tubing outer dia 20mm, SDR-11 grade with all fittings and fixed complete to walls and ceiling or laid in floors. |
| 80 | Supplying & laying CPVC water tubing outer 25mm bore pipe SDR-11 grade with all fittings and fixed complete to walls and ceiling or laid in floors.. |
| 81 | Treating and finishing the sunken portion of WC area n exc 1.2 Sqm each by providing 10mm thick rendering in cm 1:3 with and including water proofing compound andelastomeric membrane and applying two coats of bitumen, providing necessary connection items suitable for WC, providing lime concrete and 1mm thick multiples plastifelt over 20mm thick plain cement concrete 1:2:4 type B0 using 12.5 mm graded brick bat including demolition of old treatment and removal of debris complete all as specified and directed |
| 82 | All as per itemNo. 81 above but for bath/lobby with out any PVC connection Supply and fixating, area exc 1.2 Sqm and n. exc 2 Sqm each. |
| 83 | Material and labour for in repairs for 18 mm thick single side prelaminatedwooden grain and other side plainsolid PVC sheet suitably fixedin shelves, partition and shelves of built in cupboard almirahs book cases, toilet, boxes , racks, pelmet and similar work including all hardware fittingsall as specified and as directed. |
| 84 | Material and labour for in repairsfor 18 mm thick both side plainsolid PVC sheet suitably fixedin shelves, partition and shelves of built in cupboard almirahs book cases, toilet, boxes , racks, pelmet and similar work including all hardware fittings in repairs all as specified and as directed. |
| 85 | Supply and fix solid PVC frame (single rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffener and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note:- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) in repairs |
| 86 | Supply and fix Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed |
| 87 | Material and labour for preparation of new steel surfacesof any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enameled paint over one coat of red oxide Zinc chromeprimer complete all as specified and directed |
| 88 | Material and labour for preparation of OLD steel surfacesof any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enameled paint over one coat of red oxide Zinc chromeprimer complete all as specified. |
| 89 | Supply and fix Pre-painted galvalume( hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon, AZ 150 gm/sqm both side) , Zincalume (steel) based corrugated sheet 0.50mm thick ,of an approved colour, having tensile strength of 550 Mpa,and finished with resin coat on both surfacesas in roof covering/ cladding to wall, including flashings , ridges, valley etc fixed with self tapping screws complete all as specified. |
| 90 | Supply and fixin repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of approved colour hoisted and fixed in position of 500 ltr capacity. |
| 91 | Supply and fix in repair 20mm dia brass ball valvehigh pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed as directed Engr- in -Charge. |
| 92 | Supply and fixin repair 20mm bore brass Unionto connect iron to polyethylene tank complete fixed as directed by Engr- in -Charge |
| 93 | Taking down existing aluminium window shutters with frame nexc 2Sqm each and refixing in same after necessary repairs , cutting for refixing including cleats handles etc excluding wire mesh/glass pane |
| 94 | Supply and fixingPowder coated (minimum thickness of powder coated 50 micron)Aluminium anodised frame for door, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete architectural drawings and the directions of Engineer -in-charge.Note: (a) Item shall be paid as per D1 actweight of aluminium section.b) The rate shall be inclusive of the locking arrangement including required builder hardware complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area. |
| 95 | Supply and fixingPowder coated Aluminium (minimum thickness of powder coating 50 micron) for shutters (opening/sliding) for doors, windows and ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (fittings shall be paid for separately) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved making conforming to IS 733 and IS 1285, fixing with dash fasteners of required dis and size, including necessary filling up the gaps at junctions i.e.. at top , bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, CP brass/ stainlesssteel screwall complete as per architectural drawings and the directions of Engineer -in-charge.Note:a) Glazing shall be measured separately.b) Item shall be paid as per D1 act weight of aluminium section.c) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc., as required which shall not be measured for arriving the weight.d) The rate shall be inclusive of the locking arrangement including required builder hardware complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area. |
| 96 | Supply and fix powder coated aluminium grill of make DG 104 (10mm thick) with DL 102 frame. |
| 97 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones. |
| 98 | Supply and fix sheet glass ordinary quality, 4mm thick and glazing with rubber or aluminum beads in squares n exc 0.5 sqm each. |
| 99 | All as per item No. 98 above but with pin headed/figured glass n exc 0.5 sqm each pan.. |
| 100 | Taking down door shuttersnexc 2Sqm each and refixing in same after necessary repairs including cleats handles etc |
| 101 | Supply and fix powder coated fancy type curtain rails 20mm dia including bracket fixed in repairs. |
| 102 | Taking down PVC (SWR) pipes 32/ 75/110 mm bore from walls. |
| 103 | Material and labour for UPVC pipe, 75mm bore, single socketed, in any length with rubber ring joints, fixed to walls |
| 104 | Supply and fix UPVC (SWR) 110mm bore \"-ditto- as above. |
| 105 | Supply and fix UPVC (SWR) bends 75mm bore any radius dismantling pieces or tapers |
| 106 | All as in item No.105 above but 110mm bore |
| 107 | Supply and fix in repairs 15mm bore Bib tapCast copper alloy with crunch or butterfly handleCP screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed |
| 108 | Supply and fix in repairs 15mm borestop valve/concealed valveCast copper alloyCP screwed down high pressure with crunch or butterfly handlescrewed shanks and fly nuts screwed for iron pipe and fixedcomplete all as specified and directed. |
| 109 | Supply and fix CP shower roses 100mm size, with or without swivel joint including fixing to steel pipe, fixed in repairs complete all as specified and directed. |
| 110 | Supply and fix in repair vitreous china WHB, white, flat back, size 550mm x 400mm excluding taps, waste chain, and plug and porcelain stopper but including brackets |
| 111 | Supply and fix pillar taps 15mm dia Cast copper alloy with capstan heads CP screwed down high pressure with or without lettered HOT or COLD with long screwed shanks and fly nuts screwed for iron pipe and fixed |
| 112 | Material and labour for waste fitting (PTMT) for glazed ware sinks, basins etc half or full threaded with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed for 32mm bore |
| 113 | Supply and fix floor traps PVC(SWR) 75mm dia with grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) |
| 114 | Supply and fix LDPE pipes of pressure rating 6kg/cm2 fixed in floors or walls 32mm dia including breaking the existing pipe complete all as specified. |
| 115 | Supply and fix PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed. |
| 116 | Supply and fix in repair towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and plastic cleats. |
| 117 | Supply and fix in repair kitchen sinks with drainage boards made of stainless steel 1mm thick with plugs, washers & wastes, including in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes over all size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed. |
| 118 | Supply and fix Mild steel, plain, black sheet 1mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required |
| 119 | Dismantling structural steel work including doors, gates etc |
| 120 | Dismantling plain or corrugated sheeting, any guage , thickness, including Naintal or similar pattern roof coverings |
| 121 | Taking down unserviceable aluminium point wiring (light, fan, socket or power ) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials for taking credit (credit for above items should be made as per conditions separately)and making good the disturbed complete all as specified and directed . |
| 122 | Taking down unserviceablesubmain wiring Aluminium/ copper of any size/core/type including earth continuity conductor on teak wood or conduit and removing the materials/debris from site and making good the disturbed surfaces of wall etc to match with the original existing finish all as directed. |
| 123 | Taking down unserviceable existing TPN DB/ LT Panel / Meter Box withMCCBof any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed. |
| 124 | Taking down unserviceable existingDB SPN 8/10/12 way of any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed. |
| 125 | M/L Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC concealed conduit wiring (medium grade)fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor as earth conductor and connected to earth dolly, including concealedModular metal flush boxes of suitable size for mountingof modular switches, sockets, regulators etc with frame, cover plate sheet white modular cover of adequate size for housing switches, sockets, fan regulator etc concealed on wallcomplete all as specified and directed. |
| 126 | a)One light pointcontrolled by one switch |
| 127 | b)One fan/ exhaust fan point controlled by one switch and regulator |
| 128 | c) One 3 pin socket, 5 Amps on the same board, with cables 1.5 sq. mm size |
| 129 | d) One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size |
| 130 | e) One light pointcontrolled by two 2-way switches, with cables 1.5 sqmm. |
| 131 | f) One call bell controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm |
| 132 | M/L for point wiring complete with FRLS 1100 Volts grade, two runs of PVC insulated unsheathed multistranded 2.5 sqmm coppercable including rigid PVC concealed conduit wiring (medium grade) with one run of 2.5 sqmm PVC insulated and unsheathed multistranded copper conductor cable as earth continuity wire connected to common earth dolly, including concealed modular metal flush boxes of suitable size for mountingof modular switches, sockets, regulators etc with frame, cover plate sheet white modular cover of adequate size for housing switches, sockets, fan regulator etc concealed on wallcomplete all as specified and directed. |
| 133 | Material and labour for Switch modular type single pole 6/5 Amps one way all as specified and directed. |
| 134 | Material and labour for switch modular SP two way 230 V complete all as specified and directed by Engineer in charge. |
| 135 | Material and labour for modular Switch socket combination 2 in 1, 5A 3 Pin and 5A 2 pin combined flush type, 230 V ,complete all as specified and directed by Engineer in charge. |
| 136 | Material and labour for modular Switch socket combination 2 in 1, 3 pin, 5A /15A combined, 230 V ,complete all as specified and directed by Engineer in charge. |
| 137 | Supply and fix Bell push 6 Amp, modular type,230 volts, 50 HZ ,AC supply, all as specified and directed. |
| 138 | Supply and fix Ding dongBell, AC, 230 volts, single pole 50 HZ AC supply all as specified and directed. |
| 139 | Supply and fix ceiling rose three terminal 230 volt 50 HZ AC supply all as specified and directed. |
| 140 | Material and labour for submain wiring complete with 1100volt grade PVC insulated unsheathed multistranded cable with 1100volt grade PVC insulated unsheathed multistranded 02 run of 06 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC Conduit in Ivory/Grey/white colour medium grade etc fixed on wall/ceiling including provision of 01 run of 4.0 sqmm PVC unsheathed copper conductor and Connected to earth dollycomplete all as specified and as directed. Note :- 02 run of 06 sqmm and 01 run of 4.0 sqm including 01 run of PVC CONDUIT will be measured as one length. complete all as specified and directed. |
| 141 | Supply and fixMCB DB, single pole and neutral with suitablerated busbar double door, 12 way 230 volt 50 HZ AC Supply complete all as specified and directed. |
| 142 | Supply and fix MCB SP 06 to 32 Amp 230 volts,50Hz,BreakingCapacity 10 KA complete all as specified and directed |
| 143 | Material and labour forfor RCCBDouble pole, 30mA 25 Amps 230V 50Hz ACcomplete all as specified and as directed. |
| 144 | Supply, install, testing and commissioning offactory made LT panel wall mounted made out of CRCA sheet of 2 mm thick indoor type double door compartmentalized constructiontotally enclosed weather, dust and vermin proof with front opening hinged door locking arrangement 415 volt 3 phase4 wires AC 50 Hz having aluminium busbarfor phases and the neutral insulated with PVC sleeves,suitable chamber for fixing single phase electric meter -5 Nos complete, and epoxy powdercoat of spray paint over a coat of red oxideprimercomplete all as specified and directed. Meter box/panel shall be fitted semi concealed on wall. |
| 145 | INCOMING (Including) |
| 146 | (a) MCCB 415 volts 4 pole 36 KA breaking capacity fixed magnetic setting type of 100 Amps - 01 No |
| 147 | (b) R -Y-B phase LED indicating lamps - 03 Nos |
| 148 | (c)100 Amp TPN main aluminium busbar |
| 149 | OUTGOING (Including) |
| 150 | (a) MCB SP & N 32 Amps breaking capacity 10 KA \"C\" Curve - 05 Nos |
| 151 | (b)Space for mounting single phase energy meter - 05 Nos |
| 152 | (c)Copper flexible wires of 6 Sqmm sizefor all feeders/meter connection. |
| 153 | Supply and fix Integrated inverter LED battern T5tube light fitting type 1x 20 wattindoor type complete with lithium ion battery with charging time 8 to10 hours and backup time up to 4 hours includingall accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directedMake: Havells Cat part No:- LHEXACP7FN1W020 or equivalent inBajaj/Wipro/Philips |
| 154 | Supply and fixinverter LED light fitting mirror type with high out put diffuser 2 feet , 10 watt 220 v AC with driver holder and LED lamp including withlithium ion battery with charging time 8 to10 hours and backup time up to 3 hours with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed |
| 155 | Supply and fixdeluxe stepped type electronic fan regulator modular type, 2 modularcomplete all as specified and as directed, |
| 156 | Supply and fix lamp holder, PVC/polycarbonate type with back plate suitable for batten fitting complete all as specified. |
| 157 | Material and labour for Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate not less than 1.5 mtr below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, includingnecessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of requiredlength for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion. Note :- If the desired earthing result not achieved the earthing will be redone by the contractor without any extra cost. |
| 158 | Supply and fix inverter LED bulb of 9 Watt . Make :- Havells Cat part NO:- LHLDEGEDML80009 , lumen output 900 Lumen , 6500 K base cap B22. or equivalent inBajaj/Wipro/Philips |
| 159 | Material and labour for rewinding unserviceable ceiling/exhaust fan by opening the body cover of c/fan, exhaust fan, any type , any make and cutting the existing winding without damaging the stator removing the coil insulation and rewinding with new wire of suitable gauge with correct number of turns of auxiliary and main winding , varnishing and baking complete and soldering new lead of copper wire three core cables of size 23/0.0076 testing, refixing and commissioning complete including transportation from area of AGE E/M II to workshop and back to Area of AGE E/M II complete all as specified and directed for the following sizes . |
| 160 | a) Ceiling FanNote: Minor Spare parts will be included in the quoted rate |
| 161 | b) Exhaust Fan Note: Minor Spare parts will be included in the quoted rate |
| 162 | Taking down and dismantling of ceiling fan of any make and sweep 1200 mmfrom its installed location servicing the fan by cleaning ,greasing,oiling,painting with One coat of existing colour including replacement of worm out nut bolts with rubber reel , split pins, quarter pin, push bearing, ball bearing, Fan blade, Fan motorand check nutsand installing back to its original position, rate includes Rate include anchor fastener bolt complete all as specified and directed.Note:- painting, nut bolts with rubber reel, split pins/quarter pin, push bearing, ball bearing, shall be measured and paid separately |
| 163 | Supply and fix in repairsrubber reel with MS nut Bolt, split/quarter pin for hanging ceiling fan suitable for C/fan complete all as specified and directed . |
| 164 | Supply and fix in repairs ball bearing suitable for size of Ceiling fan any type and any make complete all as specified and directed . |
| 165 | Supply and fix in repairs capacitor of capacity 2.5mfd, 230 V for ceiling fan including removing old one complete all as specified and directed . |
| 166 | Material and labour for Painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filter, one coat after cleaning all dust etc. |
| 167 | S &F in repairs plastic canopy top and bottom with tighten screw suitable for ceiling fan of any sweep/type. |
| 168 | Supply and fix down rodmade of MS pipe medium grade 15mm dia of 300/600mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to of down rodwith two coat of synthetic enamel paintover one coat of red oxide primer. |
| 169 | Taking down and dismantling of Exhaust fan of any make and sweep up to 300 mm from its installed location servicing the exhaust fan by cleaning ,greasing,oiling,painting with one coat of existing colour, ball bearing, anchor fastener bolt, rewindingand installing back to its original position, Rate include anchor fastener bolt and check nuts, complete all as specified and directed.Note:- painting, ball bearing, rewinding, anchor fastener bolt shall be measured and paid separately |
| 170 | Supply and fix in repairs ball bearing suitable any make and sweep up to 300 mm exhaust fan any type and any make complete all as specified and directed . |
| 171 | Material and labour for Painting of exhaust fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filter, two coat after cleaning all dust etc. |
| 172 | Supply and fixheavy duty metal frame of 300 mm sweep exhaust fanall as specified. |
| 173 | Supply and fix in repairs capacitor 230 V for Exhaust fan including removing old one complete all as specified and directed . |
| 174 | Supply and fix in repairs anchor fastener bolt suitable any make and sweep up to 100 mm for Exhaust fan or Geyser complete all as specified and directed. |
| 175 | Removing inlet and outlet water connection , taking down existing Geysers storage type10/15/25/50 Ltr capacity and then checking of thermostat , heating element, 15 Amp Plug Top and socket, PVC connection pipe hot and cold, NRV and safety devices inner control valves, cables etc including cleaning of inner storage tank complete and fixing back testing complete all as directed.Note :- unserviceable items to be replaced shall be measured and paid separately. |
| 176 | Supply and fix in repairsthermostat BI- metal thermal relay suitable for 10/15/25 Ltrs geyser |
| 177 | Supply and fix in repairs indicator lamp for geysers (Set of 2) |
| 178 | Supply and fix in repairs heating element threaded/ push type1500 watts / 2000 watts for 10/15/25 Ltr geysers of any make |
| 179 | Supply and fix in repairs PVCconnection heavy duty 15mm size with PTMT nut of length 450 mm for hot /cold water connection |
| 180 | Supply and fix in repairs PVC three core cable 2.5 sqmm sheathed cable copper conductor |
| 181 | Supply and fix in repairs 15 Amps plug Top for geysers complete all as specified and directed . |
| 182 | Supply and fix repair suitable non return valve for any type of Geyser |
| 183 | Supply and fix in repairMultiple safety Device for any type Geyser |
| 184 | Spray painting of geysers of 10/15/25 Ltrs capacity with two coats of enamel paint over a coat of red oxide primer after removing the existing painting and cleaning the surface etc including removing from the position and re-fixing the same in original position etc complete all as specified and as directed. |
| 185 | Supply and fix in repairs for louvers of any make up to 300 mm exhaust fan, at any Bldg and at any Floor ccomplete all as specified and directed . |
| 186 | Material and labour for green marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, window, cills and like in CM (1:4) incl painting in whitecement (1:2) using marble dust with admixture of pigment to match with green marble incl 15mm thick cement screed 1:6. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail