Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in Soft/loose soil all as specified & directed. |
| 2 | Excavation in trenchesnot exc 1.5m wide and notexc 1.5m in depth; for foundation, etc. or for shafts, well, cesspits, manholes, peir holes, etc. not exc 10 Sqm on plan and getting out in soft/loose soil all as specified & directed. |
| 3 | M & Lfor Plain Cement Concrete(1:4:8)typeD-2using 40mm graded stone aggregatevas in foundation filling and mass concrete all as specified & directed. |
| 4 | M&L forHardcoreof broken stone or boulders of gauge not exc 63mm, deposited spread and levelled in layers not exc 15cmthick, watered and rammed to a true surface all as specified & directed. |
| 5 | M&L for Pre-cast cement concrete(1:3:6)type C-1using 20mm graded stone aggregate as in solidblock masonryexceeding10 cm in width and setting in cementmortar (1:6)complete all as specified and directed. |
| 6 | M&L for PCC(1:4:8)type D-2using40 mm graded stone aggregateas in75 mm thick sub base to floor complete all as specified and directed. |
| 7 | M&L forRendering 15 mm thickcement mortar(1:4) on block masonry or brick masonary surface of wallsfinished even and smoothwithout using extra cement all as specified and directed. |
| 8 | M&L forRendering 15 mm thickcement mortar(1:6) on block masonry or brick masonry surface of wallsfinished even and smooth without using extra cement all as specified and directed. |
| 9 | M & L fornon skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over & includingscreed bed 15mm thickcement mortar (1:6) all as specified and directed. |
| 10 | M & L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm / 450X 350X 7mm to 8mmthick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including backing coat 10 mm thickcement mortar (1:4) all as specified and directed. |
| 11 | M & L for Damp proof course to horizontal or vertical surface including necessary form work, 40mm thick PCC(1:2:4)type B-0using 12.5 mm graded stone aggregate all as specified & directed. |
| 12 | Supply onlywater proofing compound (solid), ISI marked all as specified & directed. |
| 13 | M&L for PCC (1:3:6)type C-2Using 40 mm graded crushed stone aggregateas in 75mm thickplinth protection/Sub base flooring, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed. |
| 14 | S&FSolid PVCdoor frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification complete all as specified and directed. |
| 15 | S&F Factory made solid panel PVC doorshutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame complete all as specified and directed. |
| 16 | S&FButt hinges 100mm size, stainless steel made,complete all as specified and directed. |
| 17 | S&FAluminium anodized barrel tower bolts 150mm long,extruded section complete all as specified and directed. |
| 18 | S&FAluminium handles 150mm size, cast type anodized, complete all as specified and directed. |
| 19 | S&F steel window or ventilators fixed type with glazing bars complete all as specified and directed. |
| 20 | S&F in repairsRotational moulded polyethene water storage tanks1000 litre capacity, triple layered,(cylindrical verticalwith closed top) hoisted and fixed in position all as specified in SSR part-IincludingPTMT Ball Valve 25mm dia,PTMT Union 25mm dia , Gun metal gate valves 25mm dia, complete all as directed. |
| 21 | S&F CPVC Pipe20mm outer dia (ISI Marked) SDR II & plain CPVC SDR II fittings fixed on wall, celing or floors complete ass as specified & directed. |
| 22 | S&FCPVC Pipe25m outer dia (ISI Marked) SDR II & plain CPVC SDR II fittings fixed on wall, celing or floors complete all as specified & directed. |
| 23 | S&F Vitreous China Wash hand basin, white flat back of size550x400 mm includingC I bracketsetc including following items complete all as specified & directed :-(i)Pillar Tapcast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts,screwed for iron pipe 15 mm dia bore.(ii)waste coupling brass chromium plated32 mm dia |
| 24 | S&FWater closet vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including connection to trap and flushing pipe, anti-syphonage pipe etc. complete all as specified & directed |
| 25 | S&FVitreous China bowl urinal flat back of size465 x 355 x 265 mm minimum, white colour, with grating and union for discharge pipe complete all as specified & directed |
| 26 | S&F PVC Low level flushing cistern 10 ltr capacity white, with inlet, ball valve, float and handle, brackets including 32mm dia PVC flush pipe, fixing in position with PVC connection pipe of 15mm dia600mm long etc complete all as specified & directed |
| 27 | S&F bevelled edge mirror of selected quality glass 5mm thick of size 600mm x 450mm, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 28 | S&FBib taps fancy type cast copper alloychromium plated with crutch or butterfly handle screwed down, screwed for iron pipe 15mm or for union complete all as specified and directed. |
| 29 | S&FStop Valves / Angle CockChromium plated cast copper alloy, fancytype screwed down high pressure with crutch or butterfly handles screwed both ends for pipes 15mm dia Bore all as specified and directed. |
| 30 | S&F Tubular towel rail ‘D’ type60cm long between flanges, 20mm dia brass chromiun plated complete all asspecified and directed. |
| 31 | S&FSoap dish of size 150mm, brass CPfixed to wall with chromium plated brass screws complete all asspecified and directed. |
| 32 | M&L for preparation of newly plastered wallsurfaces and applyingtwo coats ofcement base paintover a coat of alkali resistant primercomplete all asspecified and directed. |
| 33 | M&L for Preparation of newly plastered wall surface and applying three coats of white washetc complete all asspecified and directed. |
| 34 | M&L for PVC (SWR) floor trap 75mm dia outlet,plain with steel grating including jointing with solvent cement etc complete, fixed in repair complete all asspecified and directed |
| 35 | S&FPVC (SWR) pipes 110mm dia bore single socketed in any length with rubber ringjoints fixed to walls etc complete complete all asspecified and directed |
| 36 | S&FPVC (SWR) pipes 75mm dia single socketed in any length with rubber joints fixed to walls etc complete complete all asspecified and directed |
| 37 | S&F PVC (SWR) bends 110mm dia any radiuswith access doorcomplete all asspecified and directed |
| 38 | S&F PVC (SWR) bends 75 mm dia any radius with access door complete all asspecified and directed |
| 39 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, lintels shelves including suports etc fair finished flat surfaces complete all asspecified and directed |
| 40 | M&L forReinforced cement concrete (1:2:4)type B-1 using 20 mm graded stone aggregateasin beams, cantilevers, lintels over 1.5m span. Complete all as specified and directed. |
| 41 | M&LforPre-cast Reinforced Cement Concrete (1:2:4)type B-1 using 20 mm graded crushed stone aggregate as incover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:4) complete all as specified & directed. |
| 42 | M & L formild steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for (Columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips all as specified & directed. |
| 43 | M & L forTMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending etc all as specified & directed. |
| 44 | Excavation in post holes each not exc. 0.50Cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50m and making good surfaceall as specified & directed. |
| 45 | M & L forPlain Cement Concrete (1:3:6)type C-2 using 40mm graded stone aggregate as in foundationfilling & mass concretecomplete all as directed. |
| 46 | S&FRolled mild steel as inRooftrusses (framed), trussed,purlins, crane gantries, rails andfastenings and heavy bracketframing (Beam, tee, angle, channelor flat sections) includingdistance pieces, cleats etc.), conforming to Fe 410 -W (GdeE- 250) quality-A, complete all as specified and directed. |
| 47 | S&F Mild steel framed work such asgrills, gratings, etc. withendsof bars shoulders and/or riveted, or forged into spikes, framed guard bars, barrediron doors, ladders, framedbalusters, walk ways, railings, frame workofwater tanks and similar workconforming to Fe-290, Gde-E-165, complete all as specified and directed. |
| 48 | M&L forPreparation of new steel or iron surfaces of any description over 10cm in width or girth not otherwise described and applying two coats ofsynthetic enamel paint over a coat of red oxide primerall as specified and directed. |
| 49 | S&FPre-painted galvalume aluminium zinc coating ( 150 AZ ) GI based corrugated steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. |
| 50 | S&FPre-painted galvalume aluminium zinc coating (150 AZ ) GI based plain sheet steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, eaves board fixed with self tapping screws as specified. |
| 51 | M&L for PCC(1:2:4)type B-1 using 20mm graded stone aggregateas in coping, benching includingnecessary form work complete all as specified and as directed. |
| 52 | Returningfilling in, includingspreading levelling watering and well ramming in layers notexc 25cm thick in soft/loose soil complete all as specified and directed. |
| 53 | Removing excavated soil not exceeding 50m and depositing where directed at a lavel not exceeding 1.5m above the starting point, complete all as specified and directed. |
| 54 | Dismantling Asbestos Cement Corrugated or Semicorrugatedin Roof covering all as specified and directed. |
| 55 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed. |
| 56 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubbing down with water, etc.all as specified and directed. |
| 57 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removingrubbish of the premises all as specified and directed. |
| 58 | Taking down chowkat or frames with shutter (without taking off shutters from the frame) area exc 1.5 sqm but n.exc 4 Sqm including making good to match with adjoining surfaces all as specified and directed. |
| 59 | Taking down chowkat or frames with shutter (without taking off shutters from the frame) area not exc 1.5 sqm including making good to match with adjoining surfaces all as specified and directed. |
| 60 | M & L for pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc.complete all as specified & directed. |
| 61 | M & L for Pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified & directed. |
| 62 | M & L for PCC(1:2:4)type B-0 using 12.50mm graded aggregate as in filling in chowkats including necessary formwork etc., complete all as specified & directed. |
| 63 | S&FSecond class hard wood glazed and skeleton shutters35mm thick, open rebated & prepared to receive wire gauge (without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitread beads for securing glass etc, sizes of members of shutters as specified in SSR Pt-I, section 8, clause 8.24- (a), supplied and fitted to chowkats complete all as specified & directed. |
| 64 | S&FFlush door shutters 30 mm thick, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified & directed. |
| 65 | S&F Powder coated aluminium sliding window,three track,frame & shutter withtwo glazed shutter andone gauzed shutter with the following specificationscomplete all as specified & directed. :-(i) Aluminium frame section 116x36.50x1.80mm.(ii) Aluminium shutter glazed/skeleton section 50x20x1.50mm thick.(iii) Aluminium grill of mesh size 50mmx50mm and 4 to 5mm thick bars.(iv) Hold fast in walls includingPCC (1:3:6) type C-1 block and making goog distributed surfaces.(v) 4mm thick glass orinary quality and fixed with rubber gasket for with glazed shutter etc.(vi) Stainless steelwire mesh 0.36mm nominal dia avg aperature 1.14mm and fixed with rubber gasket for without glazed shutter etc.(vii) Aluminium disc /bow hanle and locking system complete. |
| 66 | S&FPowder coated aluminium Ventilator,partially fixed glazing and Partially louvered glazing with the following details all as specified & directed :-(i) Aluminium frame section 45x25x1.80mm.(ii)Hold fast in walls inPCC (1:3:6) type C-1 making goog distributed surfaces complete in originally shape.(v) 4mm thick frosted glass orinary quality (partially fixed glazing and Partially louvered glazing) and fixed with rubber gasket for with glazed shutter etc. |
| 67 | S&FStailess steel wire cloth, 0.36 mm nominaldia of wire and average width of aperture 1.4 mm and fixed with aluminium wire staples with wodden beading on wooden shutter or with screws to steel / aluminium shutter all as specified & directed |
| 68 | S&F second class hardwood Small fittings suchas brackets of any type, latch and hinge blocks,shaped door and window stops and the like, including all necessary\" labours;articles not exc 200 cu. cm each all as specified & directed |
| 69 | S&FSliding door bolts 300mm long, aluminium alloyanodized,with hasp & staple (bolt type) and and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified & directed |
| 70 | S&FRat tail rod pattern spring 300mm MS ordinary includingroller and rollerplatecomplete all as specified & directed. |
| 71 | M&L Preparation of new wood or wood based surface over 10cm width or girth.and applying two coats of synthetic enamel paint over a coat of pink primercomplete all as specified & directed. |
| 72 | M&L forpreparation of old steel surfaces of any description over 10cm in width or girth not otherwise described and applying one coatof Synthetic enamel paint complete all as specified and directed. |
| 73 | Dismantling of wall and ceiling board fibre pulp, insulation etc or insulation boards/ clabs blankets any thickness incl cover fillets all as specified and directed. |
| 74 | M&L for rendering 15 mm thick cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement includingmixing with water proofing compoundall as specified and directed. (Note : water proofing shall be measured & paid separately). |
| 75 | Demolition of cement concrete (unreinforced)in ground floor and paving etc n.exc 15cm thick above or below ground level including terrazzo finish wherever existing complete all as specified |
| 76 | M&L for PlainCement concrete (1:2:4)type B-0 using 12.50mm graded stone aggregate for 25mm thick sub base for floor tiles all as specified and directed. |
| 77 | M&L forSadarhalli stone slab 18-20mm thick as in flooring, steps, jambs, pillars, window- cills, steps/stairs, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade over &includingscreed bed 15 mm thick cement mortar (1:4) includingrounding to edges complete all as specified and directed. |
| 78 | M&L forSadarhalli stone slab 18-20mm thick for skirting, riser, dado and like jointing in cm (1:3) cluding pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade over & includingbacking coat 10 mm thick cement mortar (1:3) all as specified and directed. |
| 79 | S & F in repairs for Non Asbestos fibre cement building boards 4 mm thick of size 600x600mm fixed on GI/Aluminium frame work( White colour) including False ceiling Aluminium snap grid of size 600x600mmduly suspended with 6 mm dia G Ihangers (upto1200mm length) adjusting level fixed to roof slab or purlins by means of ceiling cleats made out of G I flat 40x3mm size 60mm long and expansion holdfasteners 12.5mm dia 40mm long complete all as specified & directed. |
| 80 | All as per item No. 80 herein before but except non Asbestos fibre cement building boards |
| 81 | M&L forPreparation of newly plastered wall surfacesand finishing as per following specifications all as specified & directed :- (i) Applying 1mm thickwall care putty and finished to smooth surfaces(ii) Applying onecoat of alkali resitant primer(iii) Applying two coats ofAcrylic emulsion distemper |
| 82 | M&L forcomplete removal of existing treatment of old treated surfaces of wall and finishing as per following specifications all as specified & directed :- (i) Applying 1mm thickwall care putty and finished to smooth surfaces(ii) Applying onecoat of alkali resitant primer(iii) Applying two coats ofAcrylic emulsion distemper |
| 83 | M&L for preparation of Old treated wallsurfaces and applying two coats ofcement base paintcomplete all asspecified and directed. |
| 84 | M&L for 20mm thick Granite slab 20mm thickas inwork (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15 mm thick screed bed in CM 1:6 and Rounding to edges complete all as specified & directed. |
| 85 | Demolition of brick work or PCC solid block masonary or stone/boulder masonry built in cement mortar complete all as specified & directed. |
| 86 | Dismantling boarding of any description, fixed in any position with nails complete all as specified and directed. |
| 87 | S&FMedium DensityFibre Board 19mm thick, both side finished as in wardrobe, compartments & Drawersetc allas specified and as directed. |
| 88 | S&F Continuous (piano) hinges, mild steel bright finish or electrogalvanised complete all as specified and directed. |
| 89 | S&FAluminium anodized handles of extruded section 125mm long complete all as specified and directed. |
| 90 | Dismantling unframed timber scantling 40 sq cm and over in section in any position complete all as specified and directed. |
| 91 | M&L forSecond class hard wood, clean sawn in as in scantling framed and fixed to walls with screws etc complete all as specified and directed.. |
| 92 | M&L for Preparing wood and wood based materials surfaces, new or old, of any descriptionand girth, not otherwisedescribed and treated with cresote oil paint complete all as specified and directed. |
| 93 | M&L for Chequred cement concrete tiles of size 20 cm x 20 cm x 25 mm thick set and jointed in neat cement slurry and pointed with grey cement and no pigmentsover & including 20 mm thick screed bed in CM 1:6 all as specified & directed. |
| 94 | M&L forRendering 5mm thickcement mortar(1:3)on fair faces of concrete surface of ceiling/Chajjahs finished even and smoothwithout using extra cementall as specified & directed. |
| 95 | M & L forNon skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over & including 15 mm thick screed bed in cement mortar(1:6)all as specified & directed. |
| 96 | M & L forNon skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over & including 10 mm thick backing coat in cement mortar (1:4) all as specified & directed. |
| 97 | Taking up or down steel tubing and connections 15mm bore all as specified & directed. |
| 98 | Taking up or down steel tubing and connections 20mm bore all as specified & directed. |
| 99 | S&F in repairsVitreous china wash down water closet pan ( pedestral Pattern) white, including connection to drain & or out going pipeand to flushing pipe, anti syphonage pipe, with following fittingcomplete all as specified & directed :-(i) Plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device |
| 100 | S&F in repairs Stop Valves / Angle Cock fancy type Chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends for pipes 15mm dia complete all as specified & directed. |
| 101 | S&F in repairstubular towel rail, 20mm dia ‘D’ type, 60cm long between flanges, brass chromiun plated complete all as specified & directed. |
| 102 | S&F in repairs Hand Shower (Health Faucet) 1 Meter Long, brass chromium plated, flexible Tube & Hook complete all as specified & directed. |
| 103 | M&L forPreparation of newly plastered Ceilingsurfaceand applying three coats of white wash complete all as specified & directed. |
| 104 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 105 | S & F Sheet glass 4 mm thick,ordinary quality and glazing with oil putty / timber beads in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 106 | M&L for Preparation ofold decorated ceiling surface and applying two coat of white wash etc complete all as specified and as directed. |
| 107 | S&FPVC(SWR)vent cowl for PVC pipe110mm dia bore all as specified and as directed. |
| 108 | S&FPVC(SWR)vent cowl for PVC pipe75mm dia bore all as specified and as directed. |
| 109 | Demolition ofcement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for roof /chajja padding including removal of debris outside MD land all as specified and as directed. |
| 110 | M&L for PCC(1:2:4)typeB-0 using 12.5mm grades stone aggregate as in Padding/levelling courseover roof / chajja finished even and smooth without using extra cementall as specified and as directed. |
| 111 | M&L for Rendering 10mm thick cement mortar (1:3) on brick work or concrete surface finished even and smooth without using extra cement including mixing WPCall as specified and as directed.(Note :WPC will be measured and paid seprately). |
| 112 | M & L forwater proofing treatmennt over RCC roof slab all as per following specification complete all as specified and directed:-(i)Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth (ii) Applying compatible primer/bonding bitumen @ 0.40 Litre/Sq m (iii) Applying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.80kg/Sq m reinforced with non woven polyster/HMHDPE matt black finished overand torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer\"s instructions (iv) Applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sq m |
| 113 | S & FSheet glass shelf assembly consisting of 5.5mm thick shee glass shelf 12 cm wide with chromiumplated brass bracketguard and railing60 cm long all as specified and directed. |
| 114 | S&FFloor door stopper of aluminium alloy body and tongue, anodised , with hard drawnsteel spring, overall length of cover plate is 140mm complete all as specified and directed. |
| 115 | M&L forVitrified Ceramic tiles, double charge 10mm thick (square / rectangular) polished, area of each tiles exceeding 0.36 Sqm in floor etc, set and jointed in neat cement sluryy and pointed in coloured cement to match as in floor over & including20mm thick screed bed in CM (1:6) all as specified and directed. |
| 116 | M&L forVitrified Ceramic tiles, double charge 10mm thick (square/rectangular) polished area of each tiles exceeding 0.36 Sqm as in Vertical Surface/Dado/Skirting etc set and jointed in neat cement slury and pointed in coloured cement to match over & including 10mm thick backing Coat in CM (1:4) all as specified and directed.. |
| 117 | S&F in RepairsAluminium anodised Powder coated Curtain Rod 20mm dia 1.6mm thick wall of approved quality all as specified & directed. |
| 118 | S&F in repairs decorative type curtain rod brackets suitable for aluminium curtain rod with side domes all as specified & directed. |
| 119 | S&F in repairs Stainless SteelKitchen Sink with drain board of overall size 915mm x 460mm and bowl size 410mm x 355mm x 165mm depth made of 1mm thick stainless steel sheet ( conforming to AISI -304 grade) with CP waste coupling including ball and chain 300mm long with brass cap rubber plug, 32mm bore PVC waste pipe (heavy duty ) 90 cm long, and bedded in cement mortar and fixed on CP cantilever brackets, complete as directed. |
| 120 | S&F in RepairSink Cock Wall Mounted with flange, brass chromium plated, fixed to 15 mm dia bore all as specified & directed.(Make:- Prayag Cat No 8316 or equivalent make specified in P S herein after) |
| 121 | S&F in repairs Stainless steel plate rack of size 900mm x 900mm x 250mm, made with 0.63mm thick sheetincludingfixed with rawl plug and screws on walls all as specified & directed. |
| 122 | S&F Wall mixer for mixing hot and cold water, brass chromium plated,screwed down with provision of over head shower and cock for iron pipe 15mm bore and fixed complete all as specified & directed. |
| 123 | S&F in repairs Two wayBib taps Quarter turn, brass chromium plated smooth finishfancy typewith crutch or butterfly handle screwed down, screwed for iron pipe 15mm or for union complete all as specified & directed. |
| 124 | S&F in repairsShower rose,brass chromium plated, 95mm dia fixing to steel pipe 15mm diaor union complete all as specified & directed. (Make: Cera Cat No-F7020304 or Equivalent make specified in P S herein after) |
| 125 | S&F in repairs toilet paper holder, brass chromium plated, complete all as specified & directed.( Make: Prayag, Cat No-BA-58 or Equivalent make specified in P S herein after) |
| 126 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete. |
| 127 | M & L for Concealed Point wiring with PVC insulated and unsheathed FRLSsingle core multistranded copper conductorcable 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn throughand including Concealed PVC rigid non metalicconduitin brick / stone wall conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thicklaminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulatedunsheathed copper cable as earth continuity conductor to common earth and connecting to earth dolly all as specified & directed for following:- |
| 128 | One lightpoint / ceiling Fan / Exhaust fan controlled by one 5 Amps switch one way |
| 129 | One 3 pin socket point 5 Amp on independent board |
| 130 | One 3 pin socket point 5 Amp on same board with other switches. |
| 131 | All as per serial item No.128 hereinbefore but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour all as specified & directed |
| 132 | Note for Item No 128 & 129 :-(i) The earth wire for the points in the same circuit can be looped from point to point.(ii) Earth wire shall be taken inside the conduit.(iii)Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket board to be included in point wiring. (iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls included in point wiring. |
| 133 | Supply and fix Switch piano, flush button single pole, 5 Amps one way all as specified & directed |
| 134 | Supply and fix Switch sokcet combination, flush type 5 Amps 2/3 pin muliti purpose all as specified & directed |
| 135 | Supply and fix Switch socket combination, flush type 6/16 Amps, 3/3 pin universal type multipurpose all as specified & directed |
| 136 | Supply and fix electronicFan regulator,step & socket type230 voltsuitable for 1200/1400mm sweep ceiling fan all as specified & directed |
| 137 | Supply and fix Ceiling rose,surface bakelite 65x50mm,three terminals includingPVCblocks all as specified & directed |
| 138 | S&F in replacement LED tube light fitting 10 watts capacity 6000K, 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed |
| 139 | S&F in replacement LED tube light fitting 20 watts capacity6000K, 230 volts, withaluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed. |
| 140 | S&F in repair Bldg security light light fittings 1x 35 Watt LED with New generation energy saving and environmental friendly long life LEDmade up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP66 protection and impact resistance of IK 08 with all accessories and including connection up with twine core twisted flexible copper conductor cable 1.5 M longall as specified and directed. |
| 141 | S&F in repair security light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size32mm X 5 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete including taking down unserviceable one all as specified and directed. |
| 142 | Supply and fix in repair Sheet metal enclosure (ISI marked) distribution board VTPN, 415 volts, 4 way, Vertical type, double door, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified & directed. |
| 143 | Supply and fix in repairs Sheet metal enclosure (ISI marked) distribution board, SPN 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB, 240 volts,fixed flush in wall surface, and tested on completion complete all as specified & directed. |
| 144 | Supply and fix in repair Sheet metal enclosure (ISI marked) distribution board SPN, 230 volts, 4 way horizontal type, double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified & directed. |
| 145 | Supply and fix MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity complete all as specified & directed. |
| 146 | Supply and fixMCB single pole & neutral 40 Amps 240 volts, C series,10 kA rupturing capacity complete all as specified & directed. |
| 147 | Supply and fixMCCB Triple pole & neutral 100 Amps 415 volts, C series,16 kA rupturing capacity providing in DB complete all as specified. |
| 148 | Supply and fix in replacement Sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note : Three run of 4sqmm altogether measured as one unit) |
| 149 | Supply and fix in replacement Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed.(Note : Three run of 6sqmm altogether measured as one unit) |
| 150 | M&L for taking down and dismantling of ceiling fan 1200mm/1400mm sweep 230 VoltAC of any make or model by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition with & including replacing the bearing withsimilar type of exisitng, worn out screws of the cover, split pin, twin core flexible copper wire of size 23/0.0076, locking nuts & machine screws with spring washer for ceiling fan blades, oiling and greasing etc,re-winding if necessary,finallypainting the ceiling fan with one coat of spray painting with white DUCO Paint & lettering & Numbering the same as per existing , re-assembling & testing for smooth functioningthe fan complete all as directed.(Note : Rewinding will be measured & paid seperately) |
| 151 | M&L for rewinding of ceiling fan of size 1200mm/1400mm sweep, 230 volt, 50cycles, AC by removing of burnt winding from stator and rewinding the same with super enamelled copper winding wire of same gauge, same weight & turns including varnishing of winding, drying & re-assembling, testing for smooth functioning etccomplete all as directed. |
| 152 | Taking down any type and size of Exhaust fan in any description, repair for smooth functioning, rewinding if necessary, re-assemblying, re-fixing making necessary connections & testing on completion and making good distrubed surfaces of wall, floors, etc complete all as directed.(Note : Rewinding will be measured & paid seperately) |
| 153 | M&L forRewinding of Exhaust fan with appropriate size of copper enamelled wire including varnishing, heating with proper insulation complete and testing all as specified and directed . |
| 154 | Supply & fixingExhaust fan of 300 mm sweep heavy duty, double ball bearing, 1400 RPM, metalbody , suitable for SP 230 volt, 50 Hz AC supply complete with louver shutter including fixing / grouting of frame in any type of masonry wallby corecutting using core cutting machine& connecting with & including 3 Nos 1.5 sqmm single core, PVC insulated but unsheathed FRLS 1100 volts grade cable with multi-stranded copper conductor from ceiling rose to fanfinally making good the disturbued surface ofwalls both internal& externaltoits originalspecifications complete all as directed. (Note: Quoted rate isdeemed tobe inclusive ofcore cutting towallincluding finishing the wall surface toits originalspecifications) |
| 155 | Supply and laying ofXLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Size of 35 sqmm x 3.5 core complete all as specified & directed. |
| 156 | Supply and laying of cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Size of 10 sqmm x 4 core complete all as specified & directed. |
| 157 | Supply and laying of cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Size of 25 sqmm x 4 core complete all as specified & directed. |
| 158 | Supply and lay common burnt bricks size 230 x 115 x 75 mm,bricks of sub class B,laid at right angle on the cable complete in trenches for cable protection complete all as specified and directed. |
| 159 | Supply and spreading clean dry river sand in trenches for cushioning of UG cables all as per Para 19.75 of SSR Part-I complete all as specified and directed. |
| 160 | Supply and fixing GI tubing light grade 40 mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wallcomplete including taking out if requiredall as specified and directed . |
| 161 | Supply and fixing Post top lantern LED20 watt capacity ,warm white 230 volt AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion complete with driver and lamp includingpole box complete all as specified and directed. |
| 162 | M&L forPVC insulated 2 x1.5sqmm + 1x 1.5 sqmm earth wire single core copper conductor for connection ofpost top lantern to Pole Box with PVC conduit complete all as specified and directed. |
| 163 | S & F Pole box made of high quality thermoplastic polysterene dust & jet water proof, chemical, acid corrision, impact, insulated & shock proof including terminals 4Nos andincluding fixing arrangement on pole any typecomplete all as specified and as directed. |
| 164 | Supply and fix in repair Rigid Non-metallic PVC conduit pipe exclusive of junction boxes but inclusive of all Tees,bends elbows,reducers, bell mouth tubeend and fixing acessories such as couplers, lock nuts,saddles pipe hooks etc and fixing to poles etc of size 20 mm dia. etc all as specified & directed. |
| 165 | M&L for Earthing with galvanised steel earth plate electrode 60cm x 60cm x 6mm thickburied directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 6mm dia by means ofof nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified & directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail