| 1 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 2 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 3 | S&F 2nd class HW boarding 20mm thick fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and as directed. |
| 4 | M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with nails as in ceiling,including dismantling wall and ceilling boards of any description including cover filletscomplete all as specified and directed. |
| 5 | M&L for Anodised aluminium snap grid frame work for false ceiling complete all as specified and as directed. |
| 6 | M&L for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. |
| 7 | Demolition of Precast cement concrete block walling in any position, complete all as specified and directed. |
| 8 | M&L Precast PCC (1:3:6) type C1 (using 20mm graded agg) solid block masonry exc 10cm in width or girth and setting CM (1:6) complete all as specified and directed. |
| 9 | Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed. |
| 10 | M&L for rendering10 mm thick onconcrete surface in cement mortar (1:6)as backingcoatand 5 mm th in CM 1:4 using finishing the surface even and smoothwithout using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction completeall as specified and as directed on External surface. Note:- WPC will be measured & Paid separately |
| 11 | M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and as directed. |
| 12 | Supply only for water proofing compound. |
| 13 | M&L for complete removal of existing treatment from external surface of wall and applying two coats of weather proof paint (Exterior grade) over a coat of alkali resistant primer,complete all as specified and directed |
| 14 | M&L for preparation of new plaster external surface of wall and applying two coats of weather proof paint (Exterior grade) over a coat of alkali resistant primer,complete all as specified and directed. |
| 15 | Complete removal existing treatment and applying two coats of White wash complete all as specified and as directed. |
| 16 | Complete removal existing treatment and applying1mm thick ofBirla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and as directed. |
| 17 | M & L for preparation of new plastered/concrete surfaces of walls and applying three coats of White washcomplete all as specified. |
| 18 | M & L for preparation of new plastered/concrete surfaces of walls, providing 1 mm thick ofBirla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified. |
| 19 | M&L for preparation of old paintedwooden surfaces of any description over 10 cm width or girth and applyingone coat of synthetic enamel paint complete all as specified and directed. |
| 20 | M&L for preparation of old painted of steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of Synthetic enamel paint complete all as specified. |
| 21 | Demolition of plain cement concrete (unreinforced) in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 22 | M&L for Hard core, broken stone /bouldersto gauge n exc 63 mm size , deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 23 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in plinth protection/pathincl finishing even & smooth with using extra cement in, complete all as specified and directed. |
| 24 | M&L for PCC 1:3:6 type C2 (using 20mm graded aggregate) as in surface channels and drainscomplete all as specified and as directed. |
| 25 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc |
| 26 | M&L for 25mm thick PCC 1:2:4 type B-0 (12.5 mm graded aggregate) as in levelling course of tile flooring etc complete all as specified and as directed. |
| 27 | Demolition ofstone slabs and granitelaid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc all as specified and directed. |
| 28 | M& L for Machine cut kota stone slabflooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 20 mm thick screed bed in CM 1:3 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed. |
| 29 | M& L for Kota stone slab 20-25 mm thickin riser of steps, skirting, dado and pillar laid over cement screed and jointed with and including 10 mm thick baking course in CM 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed. |
| 30 | M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set jointed andpointed in neat cement slurry in floor with grey cement and pigment over and including 15mm thick screed bed in cement mortar 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed. |
| 31 | M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls set in cement mortar 1:6 complete. |
| 32 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including bending, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 33 | S&F PVC gutter , Half Round, 180mm size complete all as specified and directed. |
| 34 | S&F Joint Bracket (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed. |
| 35 | S&F Support Bracket, 180mm for PVC pipes (half round) complete all as specified and directed. |
| 36 | S&F Running Outlet (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed. |
| 37 | S&F Stop End Outlet (with 1 clamp), 180mm for PVC pipes (half round) complete all as specified and directed. |
| 38 | S&F PVC Reducer, 180mmx110mm complete all as specified and directed. |
| 39 | S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 40 | S&F in repairs PVC (SWR) bend with access door of110mm bore complete all as specified. |
| 41 | Taking down chowkhats or frame with shutter without taking off shutter from the frame exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed. |
| 42 | Taking down chowkhats or frame with shutter without taking off shutter from the frame not exc 1.50 sqm & removing from site complete all as specified and directed. |
| 43 | Resecuring or easing & adjusting without taking down the shutter of any description exc 1 Sqm and n.exc 2 Sqm in same opening complete all as specified and directed. |
| 44 | S&F MS flat iron such as small articles for hold fast and similar work all as specified and as directed by Engineer-In-Charge. |
| 45 | Supply and fixing 2nd class HW 35mm thickGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares(without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. |
| 46 | Supply and fixing2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats. |
| 47 | S&F powder coated (min powder coating 50 micron) anodised aluminium frame for doors, windows , ventilators plain or sliding type with one or more rebates including joining cleat for fixing etc complete all as specified and as directed |
| 48 | S&F powder coated(powder coating min 50 micron)anodised window and ventilator shutters side hung/sliding type without sash , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no ) complete as specified |
| 49 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 50 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 51 | Supply and fixing 100mm size butt hinges cold rolled medium weight, ISI marked complete all as specified and directed. |
| 52 | Supply and fixing200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed. |
| 53 | Supply and fixing 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed. |
| 54 | Supply and fixing 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a min of siz bolt & nuts four on bolt & two on staple,ISI marked, complete all as specified and directed. |
| 55 | S & F 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor |
| 56 | S & F 300mm long mildsteelordinary rat tailrod pattern springs including roller and roller plate complete all a specified. |
| 57 | S & FGalvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staplescomlete all as specified and as directed. |
| 58 | M&L for 4.80 mm thick sheet glass quality and glazing fixed to aluminium frame exc 0.50 sqm complete all as specified and as directed. |
| 59 | Forming jambs, etc.to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete |
| 60 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and dircted. |
| 61 | S&F for MS frame work such as grills grating etc, with ends of bar shouldered and or riveled, or forged into spickes framed quared bars and similar work all as specified and directed conforming to Fe-290, GdeE-165. |
| 62 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in charge |
| 63 | M&L forBoulder pitching, laid dry, hand packed tightly grouted with in cement mortar (1:6) complete all as specified and as directed. |
| 64 | M&L forPCC (1:3:6) type D-2(using 40mm graded crushed stoneaggregate)in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) as directed complete all as specified and as directed. |
| 65 | Removing excavated materials (soil) n.exc. 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as direted. |
| 66 | E/M PortionTaking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified. |
| 67 | Material and labour forPoint wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked,including 20 mm casing capingPVCon wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild galvanised sunken box/metal flush box made out of 1.6 mm thick galvanised sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally includingaccessories including making goodthe disturbed surfaces as per existingfor one light point controlled by one switch complete all asspecified anddirected by Engr-in-charge. |
| 68 | All as per item No. 69 above but One 3 pin 5 Amps socket out let points on independent board |
| 69 | All as per item No. 69 above but5 Amp socket on same boardwith other switches. |
| 70 | Material and labour point wiring for power point controlled by one, one wayswitch using2.5 sqmm nominal cross sectional areamultistrandedcopper conductor ,PVC insulated unsheathedFRLSH cables in and including 20 mm width or higher size PVC casing caping and fittings of medium grade fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSHPVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed. |
| 71 | Supply and fixing submain wiring for DBs/ Power Point,two single core ,6 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including suitable sizePVC casing caping (ISI marked) including 6 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified. |
| 72 | Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified. |
| 73 | Supply and fix switch socket combination 2 in 1 multipurpose5 pin , (6 Amps ) flush typecontrolled by one switch complete all as specified. |
| 74 | Supply and fix switch socket combination5 in 1 , 6 pin , (5/16 Amps ) flush typecontrolled by one switch complete all as specified. |
| 75 | Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contactcomplete all as directed. |
| 76 | Supply and fixMCB SP,6 to 32 Amps, \"C\" series 10kA, 240 Voltsand to be housed in DBs including necessary connection complete all as specified and directed. |
| 77 | Supply and fix MCB SPN 40 - 63 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessary connectionall as specified and directed. |
| 78 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed. |
| 79 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in hard/dense soil complete all as specified and as directed. |
| 80 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. |
| 81 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. |
| 82 | Supply and fixing/laying40mm bore, steel tubings,galvanised, light grade with all fitting laid across road , in trenches or across PCC drain oralong electric pole or floor/wall etcfor protection of cable complete all as specified and as directed. |
| 83 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed. Note :- Only punned down sand shall be measured. |
| 84 | M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete. |
| 85 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core Iincluding laying in trench or fixed on wall through clamps complete all as specified and as directed by Engr-in-Charge. |
| 86 | Material and labour in repair for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI \"lightgrade\" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe \"light grade\" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. |