| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-12-2025 | corrigendum01 | Other | 10-01-2026 |
| Sl. No. | Item Description |
| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I(Ref pre-priced schedule attached separately) |
| 3 | Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately) |
| 4 | Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately) |
| 5 | Lump sum price worked out by the tenderer for ROAD, PATH, HARD STANDING AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately) |
| 6 | Lump sum price worked out by the tenderer for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately) |
| 7 | Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately) |
| 8 | Lump sum price worked out by the tenderer for FENCING, COMPOUND AND GATE as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately) |
| 9 | Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately) |
| 10 | Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately) |
| 11 | Lump sum price worked out by the tenderer for SUMMER COOLING APPLIANCES as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately) |
| 12 | Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately) |
| 13 | Schedule \"A\" Part-XII(FURNITURE) |
| 14 | Chair Verandah as per drawing No. FD-359 sheet No. 1/1 |
| 15 | Table clerks (steel) as per drawing No. FD-1004 sheet No. 1/1 |
| 16 | Table with drawer (900 mm X 600 mm X 760 mm) (steel) as per drawing No. FD-1008 sheet Nos 1/2 & 2/2 |
| 17 | Table (900 mm X 900 mm X 760 mm) (steel) as per drawing No. FD-1009 sheet No. 1/1 |
| 18 | Desk Stand Lecture (steel) as per drawing No. FD-1022 sheet No. 1/1 |
| 19 | Book case (steel) as per drawing No. FD-1028 sheet No. 1/1 |
| 20 | Locker (steel) as per drawing No. FD-1029 sheet Nos 1/2 & 2/2 |
| 21 | Almirah large steel as per drawing No. FD-1031 sheet No. 1/1 |
| 22 | Chair Writing as per drawing No. FD/E6/MAP/12 sheet No. 1/1 |
| 23 | Receptacle as per drawing No. FD/E6/MAP/13 sheet No. 1/1 |
| 24 | Dressing Table including Stool as per drawing No. FD/MAP/10 sheet Nos 1/2 & 2/2 |
| 25 | Durries of size 450 cm X 500 cm in approved shed, variety No. 5 as per IS 1450: 1991 |
| 26 | Coffeee Table as per Model No. Frappe Solidwood Coffee Table of Godrej Interior or equivalent of Geeken, Methodex as approved by the GE. |
| 27 | Counter-SDS as per drawing No. FD-159 sheet No. 1/1 |
| 28 | Chair easy per drawing No. FD-229 sheet No. 1/1 |
| 29 | Peg table (450 mm X 300 mm X 380 mm) as per drawing No. FD-277 sheet No. 1/1 |
| 30 | Teapoy as per drawing No. FD-278 sheet No. 1/1 |
| 31 | Teapoy Verandah as per drawing No. FD-383 sheet No. 1/1 |
| 32 | Table serving as per drawing No. FD-411 sheet No. 1/1 |
| 33 | Board notice (900 mm X 600 mm) as per drawing No. FD-1042 sheet No. 1/1 |
| 34 | Sofa set 5 seaters (3 + 1 + 1) as per drawing No. FD/MAP-II/02 sheet Nos 1/2 & 2/2 |
| 35 | Sofa set 4 seaters (2 + 1 + 1) as per drawing No. FD/MAP-II/02 Sheet Nos 1/2 & 2/2 |
| 36 | Table Centre as per drawing No. FD/MAP/08 sheet No. 1/1 |
| 37 | Schedule \"A\" Part-XIII(MISCELLANEOUS PARTS) |
| 38 | S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves, two ways in double control with wall flange, made of cast brass including knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 39 | M & L for construction of new valve pit/chamber of size 1050 mm (Length) X 1050 mm (Breadth) X 1050 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class \"B\" bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. |
| 40 | M & L for construction of new valve pit/chamber of size 600 mm (Length) X 600 mm (Breadth) X 600 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class \"B\" bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. |
| 41 | S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed. |
| 42 | Supplying, laying, connecting, jointing and testing in trenches 150 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K9 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed. |
| 43 | Supplying, laying, connecting, jointing and testing in trenches ductile iron fittings (special castings) (class K12 as per IS 9523: 2000) for ductile iron pressure pipe for water mains upto 250 mm nominal dia (spigot and socket and flange ends (for push on joints and flanged joints) with external coatings of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 9523: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 for push on joints and rubber gasket as per IS 638: 1979 for flanged joints complete all as specified and as directed. |
| 44 | M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 45 | M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 46 | M & L for point wiring for one 3 pin/ 5 pin/ 6 pin 5/15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 47 | M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 48 | M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 49 | S & F including testing LED batten light fitting 1 X 20 watt, 4 feet long with aluminium housing and polycarbonate diffuser complete with integrated LED driver suitable for fixation on wall/roof with robust body, corrosion resistant, flicker control, superior finish. The power factor should be more than 0.95, total harmonic distortion (THD) should be less than 20%, lumen efficacy should not be less than 100 lumens per watt, total input voltage range 140-280V AC, colour rendering Index should not be less than 80, corelated colour temperature should 5000⁰-6500⁰ Kelvin, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 50 | S & F including testing LED batten light fitting 1 X 10 watt, 2 feet long with aluminium housing and polycarbonate diffuser, 2 feet long complete with integrated LED driver suitable for fixation on wall/roof with robust body, corrosion resistant, flicker control, superior finish. The power factor should be more than 0.95, total harmonic distortion (THD) should be less than 20%, lumen efficacy should not be less than 100 lumens per watt, total input voltage range 140-280V AC, colour rendering Index should not be less than 80, corelated colour temperature should 5000⁰-6500⁰ Kelvin, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 51 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 52 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 53 | Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) |
| 54 | S & F blanking plate in DBs of MCB complete all as specified and as directed. |
| 55 | M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed. |
| 56 | M & L for cable route indicator made out of CI plate 100 dia, 8 mm thick, embossed with lettering \"MES LT Cable\", welded or bolted onto 35 mm X 35 mm X 6 mm angle iron, 500 mm long duly painted with anti-corrosive paint in brown colour & including necessary earthwork and excavation, embedded in PCC M15(Nominal Mix) using 20 nominal size graded crushed stone aggregate of size 400 mm X 400 mm X 300 mm complete all as specified and as directed. |
| 57 | S & F three core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed. |
| 58 | Supply and erect factory made 7 meter long hot dip galvanized (as per relevant IS with average coating thickness 65 micron) octagonal poles conform to IS-2062/ BSEN 10025 with 155 mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet along with foundation type base plate of size 250 mm X 250 mm X 16 mm, foundation bolt 4 Nos of M20 X 600 mm high \"J\" type EN8 grade, including 1 meter long hot dip galvanized single arm (swan neck) bracket made up of 40 NB dia GI pipe and including excavation, earth work, PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturer’s instructions including marking pole number in letters & figures of size not less than 10 cm height with red colour enamel paint complete all as specified and as directed. Note: - (i) Srl number will be issued by Engineer-in-Charge. |
| 59 | Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 4 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. |
| 60 | Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 5 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. |
| 61 | S & F road convex mirrors outdoor type made of one piece polycarbonate of size 800 mm, viewing angle 130⁰ including steel tube of nominal bore 80 mm and thickness of 4.0 mm as per IS 1161: 2014 and 1.5 metre length for mounting of mirror including painting on steel tube with synthetic enamel paint on red oxide zinc chrome primer in approved shade including embedding 300 mm below ground level including excavation and PCC M15(Nominal Mix) with using 20 mm graded stone aggregate in foundation of size 400 mm X 400 mm X 400 mm and making good surface complete all as specified and as directed. |
| 62 | S & F post delineators (road way indicators) 1000 mm high having 2 Nos of 100 mm dia and 150 mm high panel pasted with retro reflective Type IV high intensity prismatic grade sheeting in twin colours conforming to IRC 67- 2022 mounted on mild steel pipe of 65 mm dia duly powder coated with anti-corrosive paint and embedded 200 mm below ground level including excavation and PCC M15(Nominal Mix) with using 20 mm graded stone aggregate in foundation of size 250 mm X 250 mm X 250 mm and making good surface complete all as specified and as directed. |
| 63 | S & F evaporative air coolers (desert coolers) as per IS 3315: 2019, minimum air capacities 5000 cum per hour, sump tank capacity 100 litres, cooling efficiency not less than 65%, maximum power consumption 350 watts, plastic body, noise level not more than 65 dBA at 1 m distance including connecting up with three core flexible copper conductor cable of suitable size including numbering of coolers using two coats of synthetic enamel paint complete all as specified and as directed. |
| 64 | S & F telephone socket outlet including metal box complete all as specified and as directed. |
| 65 | S & F television antenna socket outlet including metal box complete all as specified and as directed. |
| 66 | S & F co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed. |
| 67 | Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner cooling type both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, ISEER 5, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 1.5 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class \"O\" Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8\" for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 year for compressor, 5 year for condenser and PCB card after Installation and commissioning of complete unit. |
| 68 | Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner cooling type both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, ISEER 5, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 2 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class \"O\" Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8\" for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 years for compressor, 5 years for condenser and PCB card after Installation and commissioning of complete unit. |
| 69 | S & F LED bulb, System Wattage: 9 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed. |
| 70 | Material and labour for construction and laying of kerb of size as directed directly on the road construction site with automatic kerb casting machine (kerb/divider making/laying machine), using M25 (Design Mix) grade cement concrete laid in position to the required line, level and curvature kerb stone cast continuous and making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) at a distance as directed, including making drainage opening wherever required, including necessary excavation/earth work and making good disturbed surface complete all as specified and as directed. |
| 71 | S & F factory made rubber coated cement concrete paver block 60 mm thick (M35 grade with minimum compressive strength of 35 N/mm2), manufactured using cement, graded coarse aggregate, , fine aggregates and synthetic rubber layer of 5mm thickness, of approved shape and size (typically 200 mm X 100 mm or equivalent) in approved colour with smooth antiskid finish having, water absorption not more than 6%, abrasion not more than 2% and high slip resistance and in accordance with the provision of IS 15658:2006, IS 10262: 2019, IS 456: 2000, IS 2308 (Pt-l to VIII) and IS 1199: 1959 and laid over 30 mm thick average sand bed , filling joints with fine sand, complete all as specified and directed. |
| 72 | Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz, 300 litres or next higher capacity with BEE approved, minimum 5 star rating single door, stabilizer free operation, Inverter Technology, R600a Refrigerant, tempered glass self, deodorizer and with fruit & vegetables drawer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer. |
| 73 | Supply and fixing factory made epoxy powder coated Distribution Board TPN 4 ways ( VTPN MCCB DB ) and space for MCCB 125 Amp as incomer, with metal door (IP54 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated neutral bar, insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts including taking down old unserviceable VTPN DB complete all as specified and as directed. Make: Legrand/Schneider or equivalent as approved by the GE.Note:- Rate of MCCB are excluding in the rate quoted for this item. |
| 74 | S & F factory made epoxy powder coated Distribution Board TPN 4 ways ( VTPN MCCB DB ) and including MCCB rated current(In): 100A, ultimate short circuit breaking capacity (Icu): 16 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, suitable for 415 V, 50 Hz AC supply as incomer, with metal door (IP54 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated neutral bar, insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts including taking down old unserviceable VTPN DB complete all as specified and as directed. |
| 75 | S & F cast iron/ ductile iron/ galvanised iron tapping saddles for tapping connection from main line of dia/ bore 100 mmm and branch line of dia/ bore of 20 mm to 25 mm including complete accessories and including necessary excavation & earth work in any type of soil complete all as specified & as directed. |
| 76 | Supply and fix LLDPE Anaerobic Underground Septic Tank of capacity 5000 litres, 2 Nos of chambers, made of rotation moulding application LLDPE materials having MFI ≥ 4.0, density ≥ 930 kg/m³, tensile stress at yield: ≥ 15 Mpa, tensile strain at yield: ≤ 25%, tensile strain at break: ≥ 80%, thickness of wall ≥ 7 mm including necessary inlet and outlet pipe of 2 metre length with submerged pipe tee, vent pipe of 2 metre length and 50 mm dia, designed to carry sewage and salvage water with up flow filter chamber, and other performance requirement and test certificates as per BMBA PC-4: 2011 including necessary excavation and earth works, footings of appropriate size and thickness in plain cement concrete works in cement concrete (M7.5) using 40 mm graded crushed stone aggregates complete all as specified and as directed. |
| 77 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 63 mm, minimum inside dia 47 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 78 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 90 mm, minimum inside dia 67 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 79 | Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 63 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: -(A) 160 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos(B) Wiring with single core PVC, copper power cable of suitable size(C) Incoming: (a) MCCB rated current (In): 100 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(D) Outgoing:(a) MCCB rated current (In): 40 A, Icu: 10 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, for 415 V, 50 Hz AC supply: -3 Nos(E) Accessories:(a) Digital voltmeter 0-500 V with selector switch – 1 No(b) Digital ammeter 0-100 Amps with CT and selector switch – 1 No(c) LED indicating lamps – 3 Nos(d) Danger Notice Plate for LT |
| 80 | Srl Item No 13.042 Continued......(F) 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 pole contactor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with 10 sqmm copper wiring, IP54 protection grade- 1 No(G) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail