| 1 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and within built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as directed by Engr-in-Charge |
| 2 | M&L for soft annealed copper tubing, confirming to relevant IS, 5/8\" and 3/8\" flare size or as required at sitefor connecting indoor and outdoor unit gas systemincluding suitable size 4 core 6 sqmm copper cable, PVC drain pipe and insulation with superlon insulation to copper tubing of required length complete all as directed by Engr-in-Charge. Note:- Both inlet and outlet copper tubing with insulation, copper cable and PVC drain pipe will be measurd as one RM. |
| 3 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, Make V-Guard VG500, complete all as directed by Engr-in-Charge |
| 4 | Supply and fix single pole and neutral enclosures with a two pin and earth plug and socket complete with one double pole MCB 20 A, 240 V complete all as directed by Engr-in-Charge |
| 5 | M&L sub main wiring concealed / surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run o f 4 Sqmm PVC insulated multi stranded copper conductor for earth continuityconductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbowscomplete all as directed by Engr-in-Charge.Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one unit length. |
| 6 | Supply and fixing load line distribution board TPN vertical, 4 way double door type,with IP 54 protection fixed on wall or semi flush with incoming MCCB 4 poles 125 Amps, 16 KA, busbars ,isolated neutral link bar , blanking plates, door earthingcomplete with all accessories complete all as directed by Engr-in-Charge. Note: Outgoing MCBs shall be measured and paid separately. |
| 7 | M&L sub main wiring concealed type/surface type with four runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 10 Sqmm, 1100 volts grade (FRLS) and one run o f 10 Sqmm PVC insulated multi stranded copper conductor for earth continuityconductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbowscomplete all as directed by Engr-in-Charge.Note :- Four runs of 10 Sqmm cable, one run of 10 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one unit length). |
| 8 | S&F MCB, SPN, 240 Volts, 5 to 32Amps. 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of single pole and neutral in the MCB DB complete all as specified and as directed |
| 9 | Demolition of cement concrete of any description in any position in sunken floor and roof slab padding & like etc including removal of debris outside the MD land and dumping ground will be sorted out by contractor at their own arrangement complete all as directed by Engr-in-Charge |
| 10 | M&L for provide padding of PCC 1:2:4 type B-0 of uniform thickness of 50mm in two layers of 25mm thickness with chicken wire mess 0.91 mm dia, laid between two layers and of 12x12mm aperture. Top surfaces of PCC padding shall be finished even and smooth without using extra cement but with false groove at 300x330 mm centre to centre, laid in slope. (Using water proofing compound of 3% by weight of cement), complete all as directed by Engr-in-ChargeNote:- WPC shall be measured and paid separately. |
| 11 | M & L for water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below including Removing of existing bituminous tarfelt including cement screed bed and clean the surface with wire brush and washing with water to achieve the original surface of slab including removing of bitumen primer applied on slab complete all as directed by Engr-in-Charge with and including the following provisions:-(a) Rendering 10mm thick cement plaster in CM (1:4) complete all as directed by Engr-in-Charge (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of ShaliTex primer (solvent based bituminous primer) conforms to IS: 3384-1986 coat of ShaliTex primer @ 0.3 Kg/Sqm shall be applied on the prepared and cleaned roof surface and parapet. Ensure not to apply when temperature is less than 5° C or during foggy period. Primer shall be allowed to dry for overnight.(c) Providing and laying APP (Atactic Polypropylene polymer) 3mm thick Super Thermolay Spun bonded non-woven polyester reinforced APP modified water proofing membrane, black finished reinforced with non-woven polyester matt weight not less than 3.5 Kg/Sqm |
| 12 | Ser. Item No. 11.00 Contd...manufactured by STP Ltd. The laying of membrane with a 75 mm longitudinal and 100mm transverse direction overlap shall be provided and laid using LPG torch and sealing all joints etc. (d) Finally applying a coat of Super Silver Shield confirmed to IS: solar reflective bituminous aluminium paint @ 0:15 Itr/Sqm on the top of membrane surfaces complete all as specified & as directed by Engr in Charge.(Make: STP Ltd or equivalent in Supremo/pidilite/fosroc)Note: i) Work shall be carried out by STP Ltd (OEM) / fosroc / Pidilite / Suprimo (OEM) respective applicator & work should be able to furnish stage wise on site technical reports from concerned company technologist during currency of work and entire completion of work.ii) Contractor shall submit 10 year OEM guarantee for water proof treatment. |
| 13 | Supplying, fixing, jointing and testing galvanised steel tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floor complete all as specified and as directed for the following sizes:-(a) 20 mm dia bore |
| 14 | (b). 25mm dia bore. |
| 15 | (c). 32mm dia bore. |
| 16 | M&L for cutting chases, pinning in, concrete block / brick / stone walling & making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing and making good, cutting exc. 20 cm girth, complete all as specified and directed. |
| 17 | Taking down cement plaster from old brick / stone masonry walls etc. including racking out joints, hacking for keys and scrubbing down with water complete all as specified and directed. |
| 18 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surface of any description exc. 10 cm width or girth, includingpreparation of new steel surfaces, complete all as specified and directed. |
| 19 | S&F PVC (SWR) pipes, single socketed, in any length, with rubber rings 110mm dia, laid in trenches / under floor/ fixed to walls including all fittings and fixtures, complete all as specified and directed. |
| 20 | S & F gun metal gate valves(Class I), with iron wheel head,screwed both ends for iron pipe, ISI marked, all as specified and directed for the following bore dia of pipe:-(a) 25mm bore. |
| 21 | (b) 32mm bore. |
| 22 | S&F in repairs 25mm bore ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed. |
| 23 | S&F in repairs 32mm bore ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed. |
| 24 | S&F 110 mm bore PVC (SWR) bends, any radius, complete all as specified and directed. |
| 25 | S&F PVC (SWR) branch piece, 110mm bore, single (Single Y) equal or unequal, with access door, complete all as specified & directed. |
| 26 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in roof kerbs or benching etc., rounded or chamfered on edges etc. to manhole including dismantling of old PCC, complete all as specified and directed. |
| 27 | Supply only water proofing compound, complete all as specified and directed. |
| 28 | M&L for cutting out cracks to V-section in existing roofs or terracing, cleaningout, wetting, grouting with cement and sand slurry 1:3, complete all as specified and as directed |
| 29 | Removing building materials etc. to a distance of n. exc. 500m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination, complete all as directed by Engr-in-Charge |
| 30 | Removing of existing water tank of capacity 500,1000 or 2000 Ltr setting aside (or lowering if required) for repair, cleaning etc and re-connecting & re-fixing in position after carrying out necessary roof treatment including necessary fittings and GI Pipes if required at site, complete all as directed by Engr-in-Charge.Note:- Necessary by pass arrangements for water supply has to be done by the contractor at his own cost till completion of roof work and nothing extra amount will be admissible on this account. |
| 31 | Supply and fix in replacement of 1000 litres capacity rotational moulded polyethylene water storage tanks (vertical cylindrical with closed top), double layered, ISI marked with existing inlet, outlets & provision of new washouts & vent pipe with and including all new tank nipples of suitable size, complete all as directed by Engr-in-Charge. |
| 32 | Supply and fix in replacement of 2000 litres capacity rotational moulded polyethylene water storage tanks (vertical cylindrical with closed top), double layered, ISI marked with existing inlet, outlets & provision of new washouts & vent pipe with and including all new tank nipples of suitable size, complete all as directed by Engr-in-Charge. |
| 33 | M&L for rendering 15 mm thick in cement sand mortar (1:4), on fair face of brick work or concrete surfaces or chajja, finished fair and even mixed with WPC as per manufacturer’s instruction complete all as specified and directed. Note:- WPC shall be measured and paid separately.(ii). Please note that height of building where plaster work has to be executed is including upto 12.00 m height. |
| 34 | Material & Labour for Preparation of new surfaces and applying Two or more coats of 100% Premium So acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as directed by Engr-in-Charge |
| 35 | M&L for Mild Steel framed work conforming to Fe-290 (Gde E-165), as in roof trusses (framed), trussed, purlins, crane gantries rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat section) including distance pieces, cleats etc, and welding or riveted complete all as specified and directed. |
| 36 | S&F roof sheeting pre-painted galvalume aluminium zinc coating 150 gms Gl based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to all, fixed with self-tapping screws including taking down old AC sheet complete all as specified and as directed. |