| Sl. No. | Item Description |
| 1 | NOTES :The bidders/contractorsare advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | Taking down cement plaster in any descriptionon brick or stone wall etc incl racking outjoints.hacking for key scrubbing down with water etc complete all as specified and directed. |
| 3 | Material, labour forrendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface on external surfaces in CM (1:4) & water proofing compound mixed with second layer @ 250 ml/Bag or as per manufaturer instructionfinished fair and even. complete all as specified and directed.Note -W.P.C. shall be measured and paid separetly. |
| 4 | Supply only integral water proofing compound all as specified and as directed. |
| 5 | Material, labour for15 mm thick rendering in CM (1:6) on other than fair face of brick or concrete surfaces on internal surfaces finishing even and smooth without using extra cement complete all as specified and directed. |
| 6 | Material, labour forrendering 10 mm thick in CM 1:3 on ceilings finished even and smooth without using extra cement (up to ceiling height of 6 to 7m )incl necessary arrangements for execution of the work all as specified and directed. |
| 7 | Demolitionof brick work or stone/boulder masonarybuilt in cement mortor incl all quions arches pillars etc complete all as specified and directed. |
| 8 | Material, labour forbrick work with fly ash bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 9 | Material, labour forbrick work with fly ash bricks, (with Old Size Bricks),straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 10 | Material, labour for15mm thick cement plaster in cement mortar 1:4 on bricks or concrete surface and finished even and smooth without using extra cement including necessary scaffolding work complete all as specified and directed by Engr -in-Charge. |
| 11 | Material, labour forforming jambs etc openings etc including cutting toothing and properly bonding into old work also facing, jointing and pointing to match existing work built in cm 1:6 complete all as directed by Engr-in-charge. |
| 12 | Material, labour for making good under cill or over arches, lintels including all pinning in with cement mortar 1:4 complete all as directed. |
| 13 | Demolition of reinforced cement concrete of any description for Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended slabs complete all as specified and directed. |
| 14 | Material, labour for formwork Use and waste to sides and soffits and suspended slabs n. exc. 200 mm thick and similar works fair finished surfaces of concrete complete all as specified and directed. |
| 15 | Material, labour forRCC M-20(Nominal Mix) 20 mm graded as in chajja supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like all as specified and directed. |
| 16 | Supply and fixing of mild steel TMT bar (Fe-500) 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 17 | Supply and fixing of mild steel TMT bar (Fe-500) 6 to 8 mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 18 | Material and labour for completeremoval of existing finishing of internal wall surface of building/structure by mechanical appliance and preparation ofold surfaces and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litreof required colour shade and as per manufacturer’s specification over a coat of primer over a coat of primer over a coat of 2.0 mm thick cement base wall putty complete all as specified and directed. |
| 19 | Material and labour for Preparation of new plaster wall surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litreof required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 2.0 mm thick cement base wall putty complete all as specified and directed. |
| 20 | Material and labour for completeremoval of existing finishing of internal ceiling surface of building/structure by mechanical appliance and preparation ofold surfaces and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litreof required colour shade and as per manufacturer’s specification over a coat of primer over a coat of primer over a coat of 2.0 mm thick cement base wall putty complete all as specified and directed. |
| 21 | Material and labour for Preparation of new plaster ceiling surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litreof required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 2.0 mm thick cement base wall putty complete all as specified and directed. |
| 22 | Material and labour for applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed. |
| 23 | Material and labour for applying one coats of synthetic enamel paint on old painted surface wooden surfaces of any description over 10 cm width or girth complete all as specified and directed. |
| 24 | Material and labour for applying two coats of synthetic enamel paint on new steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete all as specified and directed. |
| 25 | Material and labour for applying one coats of synthetic enamel paint on old steel serface of any description over 10 cm width or girth complete all as specified and directed. |
| 26 | Material and labour for completeremoval of existing treatment of external wall surface of building/structure by mechanical appliance and preparation ofold surfaces applying two coats of acrylic exteriorweather resistant paint(weather proof paint @ 1.67 ltr/10 sqmper two coats ) of required colour shade and as per manufacturer’s specification over a coat of acrylic exterior primer((@ 2.20 kg/10 sqm) over a coat of 1.0 mm thick cement base wall putty complete all as specified and directed. |
| 27 | Material and labour for preparation of new surfaces and applying two coats of acrylic exteriorweather resistant paint(weather proof paint @ 1.67 ltr/10 sqmper two coats ) of required colour shade and as per manufacturer’s specification over a coat of acrylic exterior primer((@ 2.20 kg/10 sqm) over a coat of 1.0 mm thick cement base wall putty complete all as specified and directed. |
| 28 | Demolition of cement concrete (un-reinforced) not exc 15cm thick inground floor and paving (below or above ground level) completeall as specified and directed. |
| 29 | Material, labour forPCC M-10(Nominal Mix) using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 30 | Material, labour forPCC M-7.5 (Nominal Mix) using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 31 | Dismantling Structuralsteel wok incl grills ,gates, stair case etc but excluding framed truss in any postion complete all as specified and directed. |
| 32 | Supply and fixing of mild steel in framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed by Engineer-in-Charge. |
| 33 | Material, labour formild steel rolled sections as in main and cross beams,angle, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors etc conforming to grade Fe-410- W (Gde- E- 250) quality- A made to required shape and size, welded at joints complete all as specified and directed |
| 34 | Fixing only old Joist, channel angle of beams etccutting with suitable size complete all as specified and directed. |
| 35 | Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials. |
| 36 | Supply and fixing ofpre-paintedgalvatume aluminium zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 37 | Supply and fixing of steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 gradeYst-240 including necessary form work complete all as specified and directed. |
| 38 | Cutting holes in brick walls in cement mortar for inserting holdfast or pipes and making gooddismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick, etc complete all as specified and directed. |
| 39 | Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 110mm bore as directed |
| 40 | Supply and fixing of 100 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floor complete all as specified and directed |
| 41 | Supply and fixing of in repair 100 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints fixed on wall complete all as specified and directed |
| 42 | Supply and fixing of in repair 100mm CIbends any radius complete all as specified and directed |
| 43 | Supply and fixing of in repair 100mm CI\"T\"any radius complete all as specified and directed |
| 44 | Supply and fixing of in repair 100 mm bore Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 45 | Supply and fixing of in repair 100 mm bore Cast iron nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 46 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. |
| 47 | Material & Labour of vitrified ceramic tiles,double charged, light coloured shade, 10 mm thick of square/rectangular area of each tileexceeding 0.42 Sqm and not exceeding 1.00 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over 15mm thick screed bedlayer in CM (1:4)complete all as specified and as directed. |
| 48 | All as per item No __here-in-before but to vertical surfaces such as skirting over and including 10mm thick rendering in CM (1:3) complete |
| 49 | Material & Labour Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tileexceeding 0.06 Sqm and not exceeding 0.11 Sqm , in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bedlayer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0kg of cement per Sqm complete all as specified and as directed. |
| 50 | Material & Labour Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tileexceeding 0.18 Sqm and not exceeding 0.38 Sqm , in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bedlayer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0kg of cement per Sqm complete all as specified and as directed. |
| 51 | Supply and fix non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.18 sqm but n exc 0.38 sqm in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and incl 10 mm rendering in CM 1:3 complete all as directed. |
| 52 | Material, labour for glazed ceramic colour tiles size 600/450 mm x 300 mm x 6 to 7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cementincluding 10 mm thick plastering incement mortar 1:4 completeall as specified and directed. to match completeall as specified and directed. |
| 53 | Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation oards/slabs/blankets, any thickness, including cover filletsall as specified |
| 54 | Supply and fixing ofPVC solid wall lining consisting of 5 mm thick plain colourPVC sheet used inclusive of solven tcementand fixing atsite on PVC frame as per manufacturer’s specification and instruction) directed by the Engineer-in-Charge. |
| 55 | Supply and fixing ofPVC fillets of width 35 mm, made of 5 mm thick PVC sheet, for wall paneling inclusive of fixing as in grid / frame on wall at a distance .6m horizontal & vertical for wall lining/paneling as per specification of manufacturer and as directed by the Engineer-in-Charge. |
| 56 | Supply and fixing of 12 mm thick gypsum board false ceiling including 0.55 mm thick GI perimeter channel, GI channel tray frame work having one flange of 20mm and another flange of 30mmwith web of 27mm, fixed to surrounding wall using nylon sleeves and screws @ 450mm centre to centre / GI intermediate channel of size 45mm x 0.90mm thick with two flange of 15mm each suspended from the soffit of roof slab/ truss @1220mm c/c with MS angle of suitable size fixed to soffit of ceiling with GI cleat and expansion fasteners with and including ceiling section ( not exc 1.2 metre length ) of 0.55 mm thickness having kurled web of 50 mm and flange of 25 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel @ 457 mm centre to centre with necessary nuts and bolts and gypsum board scrrewed to ceiling section with stainless steel screws @ 230mm c/c including applying two coats of Oil bounf distemper over a coat of primer to exposed surfaces complete all as specified and directed. |
| 57 | Supply and fixing of mineral fibre acoustical Suspended Ceiling System with Dune Bevelled Tegular Edge Tiles of 16mm thickness andSuprafine 15mm face exposed grid. The tiles shall have sand texture visual with acoustical punchers, Humidity Resistance (RH) of 99%, NRC 0.5 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 33db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84 with 16mm bevelled Tegular edge and 8mm drop in module completeall as specified andas directed. size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 40%. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly roduct. SUSPENSION: The tile shall be laid onSuprafine 38 with 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit usingsuspension system (specifications above) at 1200mm maximum. The First/Lastsuspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall.Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module completeall as specified andas directed.. Cut cross tees longer than 600mm require independent support. 600 x 600mm module completeall as specified andas directed. to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to bewall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as perrecommended procedure. SUSPENSION SYSTEM accessories supplied byconsisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners). |
| 58 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, dry bedded completeall as specified and directed. |
| 59 | Material and labourMachine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match shade of slab iuncl rubbing and polishing over 15mm thick screed bedlayer in CM (1:6) complete all as specified and as directed. |
| 60 | Taking down chowkhats or frames not exc 1.5 sqm each (without taking off shutter from the frame) complete all as specified and directed. |
| 61 | Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutter from the frame) complete all as specified and directed. |
| 62 | Supply and fixing of Powder coated aluminium (minimum thickness of powder coating 50 micron) Aluminium door frame and operable shutter, windows and partitions and ventalators with one or more rebates including jointing cleat for fixing etc , complete all as specified and as directed. |
| 63 | Supply and fixing of Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 64 | Supply and fixing of PVC solid factory made door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tubecomplete all as specified and directed. |
| 65 | Supply and fixing of factory made solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MSframe shall be covered with heat moulded plain colourPVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as shown in SSR Part – II 2004 and as directed. |
| 66 | Supply and fixing offactory made uPVC white colour fixed window made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose. Area exceeding 1.00 sqm but not exceeding 2.00 sqm.all as direcred, |
| 67 | Supply and fixing offactory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be mad all as specified and directed. |
| 68 | Supply and fixing offactory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extrudedprofiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account |
| 69 | Supplying and installing rectangular uPVC louver windows with fixed and exhaust made out of lead free green profiles having a worldwide presence with a GREENLINE mark with frame dimension of 58mm x 36mm for windows with aluminium powder coated framework and glass blades for louvers with corners fusion welded, fully reinforced with Galvanized steel of 1.2mm . The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised local fabrication partner . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside and Outside of Dowcorning / GE or equivalent. Scaffolding if required will be charged at actuals. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 |
| 70 | Supplying and installing curved/arch uPVC- Fixed windows made out of lead free green profiles having a worldwide presence with a GREENLINE mark with frame dimension of 58mm x 52mm x 33mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2mm . The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised local fabrication partner . The windowsmust be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside and Outside of Dowcorning / GE or equivalent. Scaffolding if required will be charged at actuals. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-201 |
| 71 | Supply and fixing of stainless steelbutt hinges,100 mm long complete all as specified and directed. |
| 72 | Supply and fixing of aluminium handles 150 mm long cast type, anodised completeall as specified and directed. |
| 73 | Supply and fixing of aluminium anodised barrel tower bolts 150 mm long of extruded section and fixed completeall as specified and directed. |
| 74 | Supply and fixing ofstainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm complete all as specified and directed. |
| 75 | Supply & Fixing in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm complete all as specified and directed. |
| 76 | Supply and fixing of 5.0 mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes all as specified and directed. |
| 77 | Supply and fixing of 10.0 mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes all as specified and directed. |
| 78 | Supply and fixing of4.8 mm thick Frosted plain glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified and directed. |
| 79 | Supply and fixing of in repair chromium plated Hand shower (health faucet), brass body with 1.2 metre long flexible tube in chrome finish with wall hook complete all as specified and directed.Make Cat no ALD-573 of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 80 | Supply and fixvitreous china wash basin, white, counter top, size 530 x 420 x140 mm rectangular shape excluding taps, waste, chain and plug and porcelain stopper complete all as specified and directed .Make Cat no JDS-WHM-25907N of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 81 | Supply and fixing of chromium plated Bottel trape 32 mm with 250 mm & 190 mm long wall connection pipe &wall flange in chrome finish complete all as specified and directed.Make Cat no ALD-769L25x190 of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 82 | Supply and fixing of in repair Chromium plated brassAngular stop cock, fancy type,concealed type with wall flange fixed to 15 mm bore of Iron pipe complete all as specified and directed.Make Cat no KUP-35053PM of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 83 | Supply and fixing ofin repair 15mm bore chromium plated two way bib cock with flange, fancy type complete all as specified and as directed.Make Cat no ARI-39041 of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 84 | Supply and fixing of Chromium plated brass Towel ring (premium quality) complete all as specified and directed. Make Cat no ACN-1121BN of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 85 | Supply and fixing of in repair 15mm dia fancy type chromium plated Single lever Tall boy with 150 mm extention body fixed spout without popup waste system with 600 mm long for iron pipe incl taking down old all as directted by Engr-in-Charge. Make Cat no FLR-5005NB of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 86 | Supply and fixing oftoilet paper holder, surface type with flap incl taking down existing holder complete all as specified and directed. Make Cat no CAN-1153N of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 87 | Supply and fixing ofVitreous china , single piece -WC with PP soft close seat cover, hinges, floor mounted water saving dual flushing EWC and white colour with concealed S-trap or P-Trap, white, 690 x 370x 710 mm, including connection to drain (or outgoing pipe) etc all as specified and as directed. Make Cat noSLS-WHT-6851S220PP of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 88 | Supply and fixing of in repair Chromium plated brassAuto closing concealed Urinal flush valvewith wall flange fancy type fixed to 15 mm bore of Iron pipe complete all as specified and directed.Make Cat no PRS-073 of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 89 | Supply and fixing of Vitreous china urinal with sensotronic sensor flushing valve fully automatic for urinal of size 385x326x635 mm with installation box with control cock (battery operaated with all accessoriescomplete all as specified and as directed.Make Cat no URS-WHT-13255 of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 90 | Supply and fixing of Urinal Partitionsfrosted curvede shape glass wall size 900x450x8-10 mm thick Siutable for Urinalfinish complete all as specified and directed.Make Cat no 1810-UC of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 91 | Supply and fixing of corner glass shelf 200 mm with brass brackets, as in repair complete all as specified and directed. Make Cat no BEA-44 of Jaquar equivalent model of Kohler/Grohe/ROCA as approved by GE. |
| 92 | Supply and fixing of in repair 6mm thick bevelled edge mirror of size as required fixed on 6mm thick acrylic PVC sheet complete all as directed by the Engr-in-Charge . |
| 93 | Material, labour for cutting chases for concealed water tubing, pinning in, making good of facings where required and pointing in cement mortar 1:3to ends or edges etc, cutting not exceeding 10 cm width or girth, complete. |
| 94 | Supplying, hoisted and fixed in position of rotational moulded polyethylene water storage tanks in double layers and cylindrical vertical type with manhole lids(closed top) of 2000 litres capacity with ISI marked and all as specified in IS 12701and including PVC float valve 20mm bore weight not less than 210gmsand taking down existing water tank complete all as specified and directed . |
| 95 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning and removing all scales, dirt etc. from the tank and from mouths of circulating pipes etc., exceeding 250 litres but not exceeding 500 litres capacitycomplete all as specifiedandas directed. |
| 96 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning and removing all scales, dirt etc. from the tank and from mouths of circulating pipes etc., exceeding 500 litres but not exceeding 1000 litres capacitycomplete all as specifiedandas directed. |
| 97 | Supply and fixing of 15mm bore galvanised steel tubes, medium grade with all fitting and fixed to walls, ceiling, floors and including taking up old GI pipe complete all as specified and as directed. |
| 98 | Supply and fixing of 20mm bore galvanised steel tubes, medium grade with all fitting and fixed to walls, ceiling, floors and including taking up old GI pipe complete all as specified and as directed. |
| 99 | Supply and fixing of 25mm bore galvanised steel tubes, medium grade with all fitting and fixed to walls, ceiling, floors and including taking up old GI pipe complete all as specified and as directed. |
| 100 | Taking down/removing of existing water proofing treatment on roof surfaces and wall surfaces complete, including screed bed, racking out joints, hacking for key scrubbing down with water etc including dismantling of lightening strip and refixing the same in position, and removing rubbish out from MD land, all as directed. (Note :- Dismantling and refixing of the lightening strip is deemed to include in the rate quoted if any). |
| 101 | Material and labour for Plain Cement Concrete M-15(Nominal Mix) using 20 mm graded stone aggregate in roof kerbs or mud stops, benching,rounded or chamfered on edges including preparation of old roof surface with brushing and applied neat cement slurry with 3.0 Kg of cement per Square Metre existing surface complete all as specified and as directed |
| 102 | Material and labour for rendering 15 mm(Avg) thick in Cement Mortar 1:3finished even and smooth witht using extra cementafterpreparation of old roof surface with brushing with water proofing treatment complete all as specified and as directed . Note:- Water proofing compound shall be measure and paidseparatel |
| 103 | Supplying and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt laying over a coat of bituminous primer @ 0.40 Ltr / Sqm and two coats of Bitumen based UV reflective paint with aluminium finish over APP membrane. The membrane shall be laid using butane torch and sealing all joints etc all as specified in Para 11.44.5 of SSR Part Icomplete all as specified and as directed. |
| 104 | Material and labour for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3all completecomplete all as specified and directed. |
| 105 | Material, labour forbituminous gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces, all as specified and directed. |
| 106 | Subtotal of Sch A part-I |
| 107 | SCHEDULE \"A\" PART - II FOR E/M PORTION (Sl No __ to ____) |
| 108 | Taking down copper/ aluminium point wiring (light, fan, buzzer, socketor power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc. |
| 109 | Material and labour forpoint wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for one light/fan point controlled by one switch completeall as specified andas directed.Note:-Flush steel terminal box, inner plate and front plates shall be measured and paid seperately. |
| 110 | Material and labour forPoint wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for modular one socket outlet 5 pin 6 amps on independent board completeall as specified andas directed. |
| 111 | Material and labour forPoint wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSH copper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly for one 5 amps socket outlet on same board with other switchcompleteall as specified andas directed. |
| 112 | Materials and Labour for Point wiring with 2.50 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 2.50 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for modular one socket outlet 5 pin 16 amps on independent board completeall as specified andas directed. |
| 113 | Materials and Labour for Point wiring with 4.00 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 4.00 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for modular one socket outlet 5 pin 16 amps on independent board completeall as specified andas directed.NOTES FOR ITEM NO_____ to ______- (i) Flush steel terminal box, inner plate and front plates shall be measured and paid seperately. (ii) Cutting chases and making good in walls shall be deemed to be included in the unit rate. |
| 114 | Supply and fixing of Modular Switch 1 way 6 A, 1 module completeall as specified andas directed. |
| 115 | Supply and fixing of Modular Switch 1 way 16 A, 1 module completeall as specified andas directed. |
| 116 | Supply and fixing of Modular Socket 6 A, 2/3 pin combined 2 module completeall as specified andas directed. |
| 117 | Supply and fixing of Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module completeall as specified andas directed. |
| 118 | Supply and fixing of Modular Bell push 6A, 1 module completeall as specified andas directed. |
| 119 | Supply and fixing of Modular type White cover plate with frame 1 module completeall as specified andas directed. |
| 120 | Supply and fixing of Modular type White cover plate with frame 2 module completeall as specified andas directed. |
| 121 | Supply and fixing of Modular type White cover plate with frame 3 module completeall as specified andas directed. |
| 122 | Supply and fixing of Modular type White cover plate with frame 4 module completeall as specified andas directed. |
| 123 | Supply and fixing of Modular type White cover plate with frame 6 module completeall as specified andas directed. |
| 124 | Supply and fixing of Modular type White cover plate with frame 8 module completeall as specified andas directed. |
| 125 | Supply and fixing of Modular type White cover plate with frame 12 module completeall as specified andas directed. |
| 126 | Supply and fixing of Modular type Metal Flush box 1/2 module completeall as specified andas directed. |
| 127 | Supply and fixing of Modular type Metal Flush box 3 module completeall as specified andas directed. |
| 128 | Supply and fixing of Modular type Metal Flush box 4 module completeall as specified andas directed. |
| 129 | Supply and fixing of Modular type Metal Flush box 6 module completeall as specified andas directed. |
| 130 | Supply and fixing of Modular type Metal Flush box 8 module completeall as specified andas directed. |
| 131 | Supply and fixing of Modular type Metal Flush box 12 module completeall as specified andas directed. |
| 132 | Supply and fixing of Ceiling rose, 3 terminal PVC insulated body |
| 133 | Supply and fixing of LED surface/ceiling mounting(suspended fromceiling) box type light fitting20Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover& highpower LED’s as light sourcewith 120Lumen perwatt (Minimum) andincluding all other standard accessories as per manufacture instructions ,internally pre-wired including connecting upthree core1.00sq. mm copper conductor flexible wire/cable complete all as specified. |
| 134 | Supply and fixing of in repairLED Ceiling light fitting 35/36 Wrecess / Surface typy as in repair, minimum colour temperature 6500K, with suitable driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specifide and directed. |
| 135 | Supply and fixing of Sheet metal enclosure verticaly distribution board TPN 415 Volt 4 way ,double door type andprovision for 4 pole MCCBcomplete with 200 Amps rated verticalinsulated busbar complete all as specified and as directed. |
| 136 | Supply and fixing of Sheet metal enclosure for MCB DB double door 415V Triple pole & Neutral 4 way with common bus bar. Make: Legrand or equivalent of L&T/Havells |
| 137 | Supply and fixingofsheet metal enclosure for MCBs to be used singal pole & nutral double door 8 Way 200 Amps rated busbarand including fixed with 25mm x 6 mm mild steel clamp of suitable length complete all as specified and as directed. |
| 138 | Supply and fixing of MCB \"C\" series single pole 5 to 32 Amps, breaking capacity 10KA. |
| 139 | Supply and fixing of MCB \"C\" curve single pole neutral , 40 to 63 Amps with breaking capacity 10kA, |
| 140 | Supply only MCB, \"C\" series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. |
| 141 | Supply and fixing MCCB 100 amps, 4 pole, breaking capacity 16 KA suitable for operation of 415 volts AC 50 HZ with fixed type allas specified in SSR Part -I including making necessary electric connections complete all as specified and directed . |
| 142 | Cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth |
| 143 | Supply and fixingof sub main wiring with four single core 10.0sqmm (nominal area) PVC insulated copper conductorFRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping andaccessoriesaccessoriesincluding two single core 10.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed.NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length. |
| 144 | Supply and fixingof sub main wiring with two single core 6.0sqmm (nominal area) PVC insulated copper conductorFRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping andaccessoriesaccessoriesincluding one single core 6.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed.NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length. |
| 145 | Supply and fixingof sub main wiring with two single core 4.0sqmm (nominal area) PVC insulated copper conductorFRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping andaccessoriesaccessoriesincluding one single core 4.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed.NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length. |
| 146 | Excavation in trenches not exc 1.5 mtr width and not exce 1.5 mtr in depth in soft/loose soil and getting complete all as specified and as directed. |
| 147 | Removal of excavated material to a disance n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 148 | Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed. |
| 149 | Material, labour forsand cushioning /sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. |
| 150 | Material, labour forbricks with sub class \"B\" locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed. |
| 151 | Material, labour forGalvanised Steel Tubing Pipe 100 mm bore (dia), light grade with Bends, laid in Trenches or under Roads/ Flooring/ Culverts etc., complete all as specified and as directed. |
| 152 | Material and labour for PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate complete all as specified and directed. |
| 153 | Material and labourforlaying ofLT XLPE insulatedarmoured heavy duty cable 1100 voltgrade ISI markedwith alumimium conductor multi strandcrosssectional area 35 Sqmm x 3 ½Corecomplete all as specified and as directed. |
| 154 | Material and labourforlaying ofLT XLPE insulatedarmoured heavy duty cable 1100 voltgrade ISI markedwith alumimium conductor multi strandcrosssectional area 50 Sqmm x 3 ½Corecomplete all as specified and as directed. |
| 155 | Material and labourforlaying ofLT XLPE insulatedarmoured heavy duty cable 1100 voltgrade ISI markedwith alumimium conductor multi strandcrosssectional area 240 Sqmm x 3 ½Corecomplete all as specified and as directed. |
| 156 | Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.00 Meter wide and not exc. 1.00 Meter in depth and getting out, complete all as specified and as directed. |
| 157 | Supply, design, install, connection, test and commission factory made powder coated (CPRI approved), cubical type, indoor vermin, dustproof LT distribution panel made out of 2mm thick CRCA steel sheet of suitable sizeand angle 40 mm x 40 mm x 5mm front and rear opening cubical shutters with locking arrangements, duly tested and powder coat painted with and including suitable size copper pre-wired connection andall as per SSR Part-I clause no 19.100 and complete all as specified and following accessories and componentsas shown in drawing.A) INCOMING:-(i)MCCB design with Microprocessor Release of capacity 400A, 4P, 36 KA- 01 Nos + Both End Spreader Link (Incoming)- 01 No,(ii) On load change over switch 4 pole 400 Amp 415 Volts - 01 No(ii)4 strip copper bus bar of rating 1.5 times current carrying capacity of incoming switch gear or not less than 600 Amp whichever higher(iii)Digital Ammeter, 0-400 Amps,with 3 Nos CT and 4 Position selector switch-1 Set , (iv)Digital Voltmeter 0-500 Volts with 4 Position selector switch - 1 set ,(v) LED Type indicator lamp R-Y-B(1 Set), (B) OUTGOING (i) MCCB 200 amps, 4 pole, breaking capacity 36 KA suitable for operation of 415 volts AC 50 HZ- 01 No,(ii)MCCB 100 A, 4 Pole, 415 Volts, 16 KA - 01 No(iii) MCCB 63 A, 4 Pole, 415 Volts, 16 KA - 01 No(iv) Space for one MCCB(v)MCB SP 6 Amps, 10 KA - 3 Nos. Current Transformer Ratio 600/5A - 03 NosNote:-(i) All incoming and outgoing cables, duly thimbled along with suitable size of brass cable glands, to be connected with accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.(iii) Earthingas perSSR 19472 and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade , charcoal dust and salt etc and connected to earthing test point including taking up of old UNSV earthing complete all as specified and directed by Engr-in-Charge. |
| 158 | Material & Labour for PCC 1:3:6 type C2 using 40mm graded aggregate as in plinth course, string course etc complete including slightly rounded or chamefered for Galvanised steel tubing post for air termination rod including form work etc complete all as specified and directed. |
| 159 | Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 25x4mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit inPCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer and including taking down existing one complete all as specified and directed . |
| 160 | Supply and fixing ofGalvanised iron strip 25 x 4mm for connection of earthing with LT Panel board burried in ground complete all as directed. |
| 161 | Supply & fix single pointed air termination Aluminium rod, 12 mm dia, 300 mm long. |
| 162 | Material and labour for Earth continuity conductor or main earthing lead, aluminium strip, 25 x 3.15 mm size, fixed to wall with epoxy earthing strip insulator of size 25mm x3 mmfixing on wall for earthing continuity conductoror buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed. |
| 163 | Test point terminal box of size 200 x 100 x 100 mm made out of 2 mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15 mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosphorus Bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws, etc complete all as specified and directed. |
| 164 | Material and labour for Earth continuity conductor or main earthing lead, GI strip, 32x6 mm size, fixed to wall with epoxy earthing strip insulator of size 25mm x3 mmfixing on wall for earthing continuity conductoror buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed. |
| 165 | Supply & Installation and testing on commissioning of Advance conductive compound based chemical compound technology with upgraded high tensile low carbon steel rod as per UL 467 and as per BS 7430 with copper Coating 250 microns. Earthing system confirming to IS:3034. The ROD should 17.2 mm & 3 Meter length with rod to tape clamp, CR 125 (type A) additional protection of the terminal. Chemical compound should be The highly Conductive Compound as per BSEN 50164-7with 25kg each bag & resistivity should be 0.05 ohm meter. The job includes digging the pit and refilling the same by fursecem Back Fill Compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having mixed with 3:1 cement , a conductive concrete is formed. The earth pit should provided with a light weight inspection pit cover PT -205 for protection and safe guard of terminals. In areas where soil condition is bad Good earth is to be arranged to fill the excavated pits by mixing fursecem a convenient and permanent solution by adding with 3:1 ratio chemical compound with the earth electrode is the main component of the earthing system which is in direct contact with the ground and thus provides a mean of releasing or collecting earth leakage currents. The material should have good electrical conductivity and anti corrosion property in wide range of soil conditions. Make : ABB FurseCEM as per RB 336. Each earth pit should contain:- 1.) 1 no. copper bonded high tensile low carbon steel, 17. 2 mm dia , 3 meter length. 2.) Rod to tape clamp (type A). 3.) 25kg chemical compound as per BSEN 50164-7 4.) Light weight inspection pit cover with 5000kg weight load capacity Complete all as specified and directed by Engr-in-charge. |
| 166 | Note: Schedule of credit (SCHEDULE OF CREDIT)amount of Rs ₹54,676.00 shall be deducted from the total quoted amount of BOQ. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail