Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-12-2025 | Tender Corrigendum | Other | 25-12-2025 |
| 2 | 12-12-2025 | BOQ Corrigendum | BOQ | 25-12-2025 |
| Sl. No. | Item Description |
| 1 | Taking down old unsv roof treatment including PCC padding if any, plastering, removing existing bitumen felt treatment including brushing, cleaning top surface of roof slab, brooming etc including disposing off debris from MoD land, complete all as specified and directed. |
| 2 | Rendering 15mm thick cement plaster with cement mortar(1:3) with water proofing compound onfair finishes of brick work or concrete surface of roof slab, to be finished even and smooth(without using extra cement ) all as specified and directed.( Water proof compound to be used shall be measured and paid separately.) |
| 3 | Supply only liquid water proofing admixture conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement) |
| 4 | Roof treatment :- Water proofing treatment to RCC roof slab including parapet as under :- (a) 1st Course: Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer.(b) 2nd Course : Applying evenly a tack coat of industrial bitumen grade 85/25 conforming to IS-702 at rate of 1.2 Kg/Sqm. (c) 3rd Course :APP (Atactic Polypropylene) modified polymeric membrane, 5 layered,3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints.(d) 4th Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions.(ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6).Note :(i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only. |
| 5 | PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as inroof kerb, padding , finished surface even and fair,complete all as specified and directed. |
| 6 | Framed mild steel work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410W Gde-E-250 complete all as specified and directed. |
| 7 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, culverts,etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and as directed . |
| 8 | Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and as directed. |
| 9 | Taking down cement plaster of any description on stone or brick walls etc. including racking out joints, hacking for key scrubbing down with water etc.complete all as specified. |
| 10 | Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement, complete all as specified and as directed. |
| 11 | Rendering 15mm thick on fair faces of brick work or cement concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed. |
| 12 | Rendering 15mm thick on other than fair faces of brick work or cement concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed. |
| 13 | Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of chalk whitening primer all as speicfied and directed. |
| 14 | Preparation of newly plastered surfaces of ceilingand applying three coat of white wash, complete all as specified and directed. |
| 15 | Preparation of old plastered surfaces of walls and applying two coat of oil bound distemper, complete all as speicfied and directed. |
| 16 | Preparation of old plastered surfaces of ceiling and applying two coat of white wash, complete all as specified. |
| 17 | Preparation of old painted surfaces with complete removal ofexisting treatment & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall complete all as specified and directed. |
| 18 | Preparation of newly plastered surfaces & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall, complete all as specified and directed.Note for item No-17 & 18:-(i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE/(ii) The work shall be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same. |
| 19 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed. |
| 20 | 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 15mm thick screed bed in cement and sand mortar 1:4 complete all as specified and as directed. Note:-(Size of Kota Stone slab shall be 52 cm x 52 cm). |
| 21 | -Ditto- All as per item No 20 here-in-before but in skirting/dado fixed over and including 10mm thick plaster in CM (1:4), complete all as specified and directed. |
| 22 | Non skid coloured ceramic tiles 7 to 8 mm thick(square / rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in CM (1:4) finished fair and even, complete all as specified and directed. |
| 23 | Providing cement concrete type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate), 50 mm thickas in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair ontop without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight), complete all as specified. |
| 24 | 25 mm thick PCC 1:2:4 type B-0, (using 12.5mm graded crushed stone aggregate) as in sub base / levelling courseincluding finishing surface of concrete topping even and rough , complete all as specified and as directed. |
| 25 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) n.exc 1.5 Sqm each, complete all as specified and directed. |
| 26 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each, complete all as specified and directed. |
| 27 | Factory made Pressed steel frames of size 105x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25 x 3mm thick flat iron projecting 10cm on either side & tarring back of chowkats and holdfasts, complete all as specified & directed. |
| 28 | Factory made Pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25X3mm thick flat iron projecting 10cm on either side & tarring back of chowkats and holdfasts, complete all as specified & directed. |
| 29 | PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) for hold fast blocks,back filling of chowkhats including necessary form work for rough finished surfaces etccomplete all as specified and as directed. |
| 30 | PCC 1:3:6 type C-1 (Using 20mm graded crushed stone aggregate) for hold fast blocks, including necessary form work for rough finished surfaces etccomplete all as specified and as directed. |
| 31 | 35 mm thick Flush shutters, solid core with particle board exterior grade as per IS-2202 of 199 (Part-I).Flush door shutter shall be internally lipped as per clause 8.52.2 of SSR-2009 Part-I complete all asspecified and directed. |
| 32 | 35mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc divided into square with sash bars, edges of framing plain, chamfered or rounded fitted with cut and metered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed. |
| 33 | 03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and directed. |
| 34 | Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed. |
| 35 | 150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed. |
| 36 | Aluminium handles cast type anodised of size 100mm long ISI marked with screws complete all as specified and as directed. |
| 37 | 300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and as directed. |
| 38 | Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length of cover plate 100mm , all as specified and directed. |
| 39 | Curtain rail ,20 mm dia Stainless steel ,chromium platedfixed with CP bracket, incl taking down of old curtain rods, complete all as specified and directed. |
| 40 | Steel windows/ventilator (Box type) factory made with double shutter with or without devetailed bar ( glass & gauged shutter) of size 79mmx39mm,16 gauge rectangular tubular frame withside hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh No 1/1 to 1/3 .Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid separately under respective item |
| 41 | Factory made box type steel ventilators top hung shutter shutters glass/glazed including guard bars ,hinges,steel handle,tower bolt and steel peg stay,complete with or without glazing bars ,devotiled or welded,including one coat of red oxide primer complete shown as drawing No (CEUZ/TD/1517/15 Sh No 1/3 to 3/3) |
| 42 | Preparation new steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed. |
| 43 | Broken stone boulder hardcore of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface, complete all as directed. |
| 44 | 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, finishing fair & even complete all as specified and directed. |
| 45 | Sand cushioning in flooring below interlocking tiles laid in layers 25mm thick complete all as specified and directed. |
| 46 | Machine pressed precast concrete interlocking paver block of any shape and size approved by Engineer-in-charge, 60mm thick,M-35 grade , in paths and hardstanding,with grey cement and coloured pigment, laid tightly overand joints filled with dry sand. (Colour and pattern as approved by GE) complete all as specified and directed. |
| 47 | PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles including necessary form work complete all as specified and directed. |
| 48 | Excavation in trenches, n.exc. 1.5m wide and n. exc 1.5m in depth, for foundation, etc and getting out in any type of soil, complete all as specified and directed. |
| 49 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed. |
| 50 | Removing surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 51 | Surface excavation n exc 30cm deep and averaging 15 cm any type of soil, complete all as specified and directed. |
| 52 | Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/ sqcm in field using 400 Kg of cement per cum, thickness of concrete 25 cm or less complete all as specified and directed. |
| 53 | Forming 12mm thick expansion joints filled with pre-formed bituminuous filler and top 30 mm primed and sealed with sealing compound grade A, complete all as specified and directed. |
| 54 | Forming contraction joints (dummy joints) 65mm deep and 10mm wide filled with sealing compound grade A, completeall as directed. |
| 55 | Dismantling timber scantling 40 sqcm and over in section, as in any position, complete all as specified and directed. |
| 56 | Dismantling of asbestos, cement (corrugated, semicorrugated, etc.) sheets in roof coverings , complele all as specified and directed. |
| 57 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) any thickness including cover fillets all as specified and directed. |
| 58 | Rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality \"A\" complete all as specified and as directed. |
| 59 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 60 | Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/ roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 61 | 4mm thick prelaminateddesigner ceiling board over & including GI snap grid frame work (Grid size 600x600mm) with powder coated GI angle of size 25x25x3mm fixed along wall perimeter, main runner \"T\"of size 25x40x3mm , secondary runner \"T\" of size 25x30x3mm suspended with 3mm GI wire @ 1200mm c/cof ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels, complete all as specified and as directed. |
| 62 | Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 in half brick thick, complete all as specified and directed. |
| 63 | 35mm thick, IInd class hard wood plain, framed, panelled factory made shutters (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified & as directed. |
| 64 | 300mm Mild steel ordinary rat tail helical door springs including roller and roller plate fixed, complete all as specified. |
| 65 | Mild steel cold rolled butt hinges 100 mm long complete all as specified. |
| 66 | Preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint ,complete all as specified and directed. |
| 67 | Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 68 | Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, Complete all as specified and directed. |
| 69 | Steel water tubing 15mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, complete all as specified. |
| 70 | Steel water tubing 20mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, complete all as specified. |
| 71 | Rotational moulded polyethylene 03 layer water storage tanks of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and as directed. |
| 72 | Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe20 mm dia (minimum weight 210 gms) complete all as specified. |
| 73 | Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 74 | Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed. |
| 75 | GI frame work 605 x 605mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centreintermediate channel 0.9mm thick having two equal flanges of 15mm each web of 45mm suspended from sofit at approx x 900mm c/c with GI cleat and steel expansion fasteners with and including celing section (n.exc 1.2m length) of 0.55mm thickness having kruled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 complete all as specified and directed. |
| 76 | Non asbestos E board classic ( Designer tiles) of 4mm thick of size 60X60cm boards laid on GI snap grid for ceiling complete all as specified and directed. |
| 77 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified anddirected. |
| 78 | Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCcasing capping 20 mm dia medium grade andincluding cutting, chasing work at any height and all accessories are surfaceinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 1.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:- (Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used of same make/brand onlyand shall be deemed in to included in quoted rate only.) |
| 79 | One light point/fan /bell pointcontrolled by one switch. |
| 80 | One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . |
| 81 | One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . |
| 82 | Materialand labour for point wiring complete with 2.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 2.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:-(a) One 6 Pin 6/16 Amps socket outlet point controlled by one 16 Amps switch on independent board (Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers and allto be used of same make/brand onlyand shall be deemed in to included in quoted rate only.) |
| 83 | Modular type switch 6 Amps, single pole, 1way,1 module, 240V, ISI Marked complete all as specified and directed. |
| 84 | Modular type switch 16 Amps, single pole, 1way,1 module, 240V, ISI Marked complete all as specified and directed. |
| 85 | Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked complete all as specified and directed. |
| 86 | Modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI MarkedComplete all as specified and directed . |
| 87 | Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 88 | Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed. |
| 89 | LED light fitting 1x20W, 4 feet, 220V, general purpose surface and wall mounted LED batten with aluminium housing integrated electronic driver LED fitting light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete as in repairs as approved by GE all as specified and directed. |
| 90 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 Vgeneral purpose surface and wall mounted LED batten with aluminium housing integrated electronic driver LED fitting including connecting up with three core flexible copper conductor cable of suitable size complete incl testing after fixing in repairs as approved by GE all as specified and directed. |
| 91 | 20 Watt LED batten/inverter capacity and polycarbonate channel, lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hours with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable fixed in repairs complete all as specified and directed . |
| 92 | LED bulb 12 watts, 240Volts,50Hzpin type andincluding removing old unserviceable itemcomplete all as specified and directed. |
| 93 | 25 Watt LED energy saving light fitting in replacement environment friendly long life LED streetlight made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 with GI bracket made of light grade GI pipe 40 mm dia of 1.2 mtr long bent to shape with 02 Nos of FI clamp 32 x 4mm with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and directed. |
| 94 | Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, blanking plates where required testing and commissioning in replacement, complete all as specified. |
| 95 | Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 12 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, blanking plates where required testing and commissioning in replacement, complete all as specified. |
| 96 | MCB single pole 6 to 32 amps 240 volts 10 KA \"C\" series fixed in repair, complete all as specified. |
| 97 | MCB single pole & neutral 40 to 63 amps 240 volts 10 KA \"C\" series fixed in repair, complete all as specified. |
| 98 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground leel, connecting to the Galvanised earthing lead strip 32x6mm size, by means of bolts, nuts, heck nuts and washers of galvanized iron andearth lead protected by provision of GI medium grade pipe 65mm bore incl provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs02 Nos and with 6mm dia MS bar handle made to shape GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 40mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs, all as per electrical plate No 5 of SSR-1991 Part I and connected to earth test point all as specified or indicated incl testing on completion. |
| 99 | Exhaust fansingle phase metal body, AC 230 Volt, 50 Hz, 900 RPMof size 300mm sweep with louvers shutter complete with all accessories including connecting up from ceiling rose and taking down existing one complete all as specified and directed. |
| 100 | Sub main wiring complete with 2 runs of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLS type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn throughrigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLStype as earth continuity conductor connected to common earth dollyincluding cutting and chiselling and making good the disturbed surfaces to match with existing surface complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 101 | Ceiling fans complete with blades, down rods, and accessories, 230 volt, 1200mm sweep, min air delivery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) including taking down old u/s ceiling fan complete all as specified and directed. Make:- Cat Part No Zinger of Make Havells or its Equivalent cat part of make as specified in list of make here- in after.Note : Old unsv ceiling fan shall be deposited to MES Store Yard. |
| 102 | Supply & fixing and in repair sheet metal enclosure double door 240 volts AC, VTPNdistribution board 4 wayfor flush mounting with 200amps copper busbar,neutral bar,earth barand MCB incomer of rating upto 125Amps and MCB SP/DPas outgoing and complete connecting cable linkswith top and bottom removable gland plate withIP 43 DBs protection and including M&L for MCCB 125Amp, TPN 16KA, 415 Volts as incomer and 06 Nos MCB, SP, 63 Amp, C Series as outgoing including making good the disturbed surfaces to match with existing surface and colour coatall as specified and as directed. |
| 103 | MCCB 04 pole 63 Amps, 16 KA, TP, 415 volts adjustable thermal magnetic setting type suitable for TPN vertical loadline DB fixed in replacement with neutral link including aluminium cable lugsall as specified and directed. |
| 104 | Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 35 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 105 | Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 25 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 106 | DWC HDPE tubing 50mm dia for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Note:- Rate for GI clamp with screws required for fixing of HDPE tubing in the wall/drainage shall be inclusive in quoted rate. |
| 107 | DWC HDPE tubing 40mm dia for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Make : SFMC, Prince, Supreme, Finolex.Note:- Rate for GI clamp with screws required for fixing of HDPE tubing in the wall/drainage shall be inclusive in quoted rate. |
| 108 | Precast factory made chequered designer tiles (Rectified interlocking tiles)300x300 mm glazed topmade in white cement and pigment base of thickness not less than19 mm indifferent colour and pattern (compressive strength not less than 250 Kg/SqCm) setand jointed in neat cement slurry(colour and pattern as per sample kept in GE office as approved by GE)including 15 mm thick screed bed in CM 1:4 all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail