| 1 | Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | M&L for second class hardwood as in scantlings clean sawn timberfixed including dismantling old timber scantlings 40 sqcm and over in section, in unframed work any position complete all as specified and as directed. |
| 3 | All as per Ser item No 2.00 (here-in-before) but except timber complete all as specified and directed. |
| 4 | Dismantling of chicken wire lathing complete all as specified and as directed. |
| 5 | M&L for 15mm thick plastering in CM (1:4) on one side of lathing in two separate layers without using extra cement but using water proofing compound @ 3% by wt of cement for finished even and smooth including demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing with and including provn of GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and as directed.Note:-WPC will be measured and paid separately. |
| 6 | M&L for rendering 12 mm thick in CM (1:6) on other side of lathing finished even and smooth without using extra cement complete all as specified and as directed. |
| 7 | Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. |
| 8 | S&F 0.8mm thick Plain, black mild steel sheeting in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) complete all as specified and as directed. |
| 9 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifiedwith complete all as specified and as directed. |
| 10 | S&FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifiedwith and including dismantling of old plain/corrugated Asbestos cement sheet complete all as specified and as directed. |
| 11 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecifiedwith and including dismantling of old plain/corrugated Asbestos cement sheet complete all as specified and as directed. |
| 12 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecifiedcomplete all as specified and as directed. |
| 13 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to GDE Fe 410-W(Gde-E-250) quality-A including dismantling of old unsv steel from its position complete all as specified and as directed. |
| 14 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to GDE Fe 410-W(Gde-E-250) quality-A complete all as specified and as directed. |
| 15 | S & F Plates (plain or chequered) channels,squarecutor notched (ordinaryand countersunk) forming holes, without any attachment conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. |
| 16 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete ncluding dismantling of old unsv steel from its position complete all as specified and as directed. |
| 17 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete complete all as specified and as directed. |
| 18 | M&L for 30mm thick 2nd class hard woodGlazed and skelton window and ventilator shutter, open rebated and prepared to receive glass, gauge etc. divided into squares with plain chamfered or rounded, mitred and rebated without sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified. |
| 19 | S&F butt hinges medium grade cold rolled mild steel and fixed size of hinges 75 mm long size complete all as specified and as directed. |
| 20 | S&F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long complete all as specified and as directed. |
| 21 | S&F Aluminium handle cast type anodised 125 mm long complete all as specified and as directed. |
| 22 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and as directed. |
| 23 | M & L for RCC design mix(M-25) as in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 24 | M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 25 | M&L for mild steel TMT bars 6 to 8mm dia and over cut to length, bent to shape required, including cranking, bendingand binding with and including mild steel wire (annealed) not less than 0.9mm dia (annealed) for stirrups/binders complete all as specified and as directed |
| 26 | Use and waste of formwork to chajjas, troughs and similar items including edges complete all as specified and directed. |
| 27 | Roughening surface of old concretefloor by picking, sweeping clean and washing down with water to removedust, etc complete all as specified and as directed. |
| 28 | M&L 25 mm thick PCC (1:2:4) type B-0 (using 10mm graded stone aggregate) as in subbase of flooring finished even and fair using extra cement complete all as specified and as directed. |
| 29 | M&L for PCC (1:4:8) type D-2, 100 mm thick (using 40 mm graded stone aggregate) as in sub base of floor complete all as specified and as directed by the Engineer-in-Charge. |
| 30 | M&L for mirror polished machine cut kota stone slab flooring 20-25 mmlaid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, laid over and including 20 mm thick screed bed in cement mortar (1:4) including dismantling old one from its position complete all as specified and as directed |
| 31 | M&L for 75 mm thick PCC (1:3:6) type C-2 , (using 40 mm graded stone aggregate) in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and as directed. |
| 32 | M&L for plain fillets, square, rectangular or triangular in section clean sawn, secured with nails made out of 2nd class hard wood exc 13and n.exc 25 sqcm complete all as specified and as directed. |
| 33 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed. |
| 34 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed. |
| 35 | M&L for brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan exceeding 6 m mean radius, built in Cement Mortar (1:6) complete all as specified and as directed. |
| 36 | M&L for brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and as directed. |
| 37 | M&L for Rendering 15 mm thick in CM (1:6) on fair face of brick-work or concrete surface to be finished even and smooth without using extra cement complete all as specified and as directed. |
| 38 | M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and directed. |
| 39 | M&L for preparation of new plasteredsurfaces of walls and applying three coat white wash completeall as specified and directed. |
| 40 | M&L for one coat of white wash on old decorated wall surfaces including removing of grass, creepes, vegitation growth etc complete all as specified and as directed. |
| 41 | M&L for preparation of new plastered surfaces and applying two coats ofcement base paint over a coat of primer of approved shade on walls complete all as specified and as directed. |
| 42 | M&Lforcomplete removal of existing treatement on old plastered surface of wall & applying two coats of cement based paint over a coat of primer complete all as specified and as directed. |
| 43 | M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink wood primer complete all as specified and directed. |
| 44 | M&L for preparation of oldsurfaces of wood and wood based surfaces of any description over 10 cm width or girth not otherwise described andapplying one coat of synthetic enamel paint complete all as specified and as directed. |
| 45 | M&L for preparation of newsurfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying two coats of synthetic enamel paint over a coat of red oxide primer on new surfaces in any tint complete all as specified. |
| 46 | M&L for preparation of old surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying one coat of synthetic enamel paintin any tint complete all as specified. |
| 47 | Surface excavation n.exc 15cm deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 48 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified ans as directed. |
| 49 | M&L for PCC (1:4:8) type D-2 (using 40mm graded stone agg) as in foundation, filling and mass concrete complete all as specified and directed. |
| 50 | M & L for RCC design mix(M-25) as in foundations, including rafts, footings, foundation beams, Plinth beams, bases for columns etc , basement slabs , under reamed piles and mass concrete design mix complete all as specified and as directed. |
| 51 | M & L for RCC design mix(M-25)as in columns, pillars, piers, posts and strutscomplete all as specified and as directed. |
| 52 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 53 | Use and waste of formwork to sides of pillars posts, struts, piers, columns and stanchions finished the suface rough. |
| 54 | M & L for RCC design mix(M-25) as in as in beams, cantilvers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 55 | S&F 1mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed. |
| 56 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed. |
| 57 | M&L for hardcore (broken stone/boulders) of gauge exc 63mm but n.exc 100mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface etc complete all as specified & directed by Engr-in-Charge. |
| 58 | M&L forsand filling under floor or foundation including watering and ramming complete all as specified ans as directed. |
| 59 | M&L for PCC (1:4:8) type D-2, 75 mm thick (using 40 mm graded stone aggregate) as in sub base finished even and rough complete all as specified and as directed by the Engineer-in-Charge. |
| 60 | Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified ans as directed. |
| 61 | Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed. |
| 62 | S&F bands, straps or stays , plain angle cleats or flat irons cleats or securing purlins to wooden trusses or rafters, knee pieces and similar small articales etc conformings to Fe-290 Grade E-165 complete all as specified and directed by Engr-in-charge. |
| 63 | M&L for Rendering 10mm thick cement plaster in CM (1:6) on fair faces of brick work/concrete surfacesfinished even and smoth without using extra cement complete all as specified and directed. |
| 64 | M&L for applying two coats of oil bound distemper over a coat of primer over a coat of 2mm thick wall care putty(in two layers) on new plastered surfaces of walls including preparation of newsurface complete all as specified and as directed. |
| 65 | M & L for RCC design mix(M-25) as in chajjas complete all as specified and as directed. |
| 66 | Use and waste of formwork to sides and soffits of floors or roof beams, beams haunchings, girders,bressummers lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams complete all as specified and directed. |
| 67 | Supply only integral water proofing compound etc complete all as specified and directed. |
| 68 | M&L for rendering 5 mm thick cement plaster in CM (1:3) on ceiling finished even and fair complete all as specified. |
| 69 | M&L for applying two coats of oil bound distemper over a coat of primer on new plastered surfaces of walls including preparation of newsurface complete all as specified and as directed. |
| 70 | M&L for cement concrete type C-2 (1:2:4) (using 20 mm graded stone agg) as in surface channels and drains complete all as specified and as directed. |
| 71 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms mouldscomplete all as specified and as directed. |
| 72 | M&L for Point wiring in repairs complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable1100 volts grade with multi-stranded copper conductors, drawn throughand including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. as required at site complete all as specified and as directed. |
| 73 | Onelight/Fan point controlled by one, one way switch . |
| 74 | One 3 pin socket outlet 5 Amps on the same board with other switches. |
| 75 | One 3 pin socket outlet 5 Amps on the switch socket combination. |
| 76 | All as per item No- 72.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. |
| 77 | M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable1100 volts grade with multi-stranded copper conductors, drawn throughand including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. as required at site complete all as specified and as directed. |
| 78 | Onelight/Fan point controlled by one, one way switch . |
| 79 | One 3 pin socket outlet 5 Amps on the same board with other switches. |
| 80 | One 3 pin socket outlet 5 Amps on the switch socket combination. |
| 81 | All as per item No- 74.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. |
| 82 | Material and labour for (concelaed Type) point wiring including necessary chases cutting of wall for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) PVC sheathed multistranded copper conductor cable 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessoriesand sunk GI box for mounting of fittings like switch, socket and fan regulator etc and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge |
| 83 | Onelight pointcontrolled by one, one way switch . |
| 84 | One 3 pin socket outlet 5 Amps on the Independent board. |
| 85 | S&F Switch piano flush type single pole, one way 5A complete all as specified and as directed. |
| 86 | S&F Socket outlet, 2 in 1, 3 pin 5A flush type complete all as specified and as directed. |
| 87 | S&F Switch socket combination 2 in 1, 5Aflush type complete all as specified and as directed. |
| 88 | S&F Switch socket combination 2 in 1, 5A/16A, 5 in 1 flush type complete all as specified and as directed. |
| 89 | S&F stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 90 | S&F in repair ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and as directed. |
| 91 | M&L for sub main wiring with two runs of4 Sq mm and one run of 4 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping including including taking down old unsv one complete all as specified and as directed. NOTE:- two runs of 4 Sq mm + one run of 4 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length |
| 92 | S&Fin repairs LED Light fitting 1 x 20 watt (4 Ft), basic all purpose surface and wall mounted LED battern with polycarbonate housing & intergrated electric driver with all accessoriesincl connecting up with and incl twin/ three core twisted flexible copper conductor cable of suitable size in and incl flexible hose from ceiling rose to fitting complete all as specified and as directed. |
| 93 | Supply , fixing and testing in repairs/replacement of LED Bldg Security light fitting of capacity 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with and including 1.2 mtr GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling of holes as reqd and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to the light fitting complete all as specified and as directed. |
| 94 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling and connecting up with driver, three core flexible copper conductor of suitable size complete all as specified and as directed. |
| 95 | S&F MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, withneutral link & earth bar etc. and fixing MCBs of various rating capacity MCB DBs complete all as specified and as directed. |
| 96 | S&F MCB Distribution board double door type SPN 4 way, sheet steel, powder painted, withneutral link & earth bar etc. and fixing MCBs of various rating capacity MCB DBs complete all as specified and as directed. |
| 97 | S&F in repairs MCB SPN 40 to 63 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DB complete all as specified and as directed |
| 98 | S&F in repairs MCB SPN 32 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DBi complete all as specified and as directed |
| 99 | S&F in repairs MCB SP 6 to 32 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DB complete all as specified and as directed |
| 100 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 101 | M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. |
| 102 | M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 2 core including taking up/down old unsv one complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. |
| 103 | M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.Make : Richa/Finolex/Polycab |
| 104 | M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: Punned down thickness shall only be measured and paid. |
| 105 | M&L for laying brick sub class \"B\" old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed |
| 106 | Supply & laying tubes \"light grade\" galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 32 mm dia bore including taking out unsv GI tubing complete all as specified and as directed. |
| 107 | Supply & laying tubes \" Light grade\" galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore complete all as specified and as directed. Make : Tata/Jindal/Prakash |
| 108 | M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. NOTE:- (i)The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 chamber, CI cover 10 m thick, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSRPart-II. (ii)Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. |