| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. 2.7.1 All kinds of soil : |
| 2 | Supplying and laying of stone soling hand packed tightly incl ramming watering and filling of interstices incl all carriage complete job |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including all carriages |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platforms. |
| 5 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50mm thick with 20 mm nominal size stone aggregate. |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size inlcuding all carriages |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) i/c Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level including all carriages for 30km |
| 9 | Providing and applying plaster of paris of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 10 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 11 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws First class kail wood 35mm |
| 12 | Providing and fixing of door/window fittingTower bolts 100 mm |
| 13 | Handles 125 mm |
| 14 | Dry random rubble masonry with hard stone in foundation and plinth:With bond stone. Quarry including all carriages |
| 15 | P/F of Ssanitary ItemWC Commode cistern |
| 16 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 17 | Basin Mixer |
| 18 | Wall Mixer |
| 19 | Soap Case |
| 20 | Towel Rod |
| 21 | Wash Basin with Pedestal in Water Pipe |
| 22 | PVC connection |
| 23 | Geyser 50 Litre |
| 24 | corner shelf |
| 25 | Health Faucet |
| 26 | Angle valve |
| 27 | PVC pipe 100 mm dia including all fixtures |
| 28 | GI pipe 20 mm |
| 29 | Looking Mirror |
| 30 | Towel Ring |
| 31 | Floor Trap |
| 32 | Door Tee (1oo mm) |
| 33 | Construction of Main hole as per directions of EIC |
| 34 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer |
| 35 | Electric partWiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK) excluding the cost of conduit. |
| 36 | Supply, Installation, Testing and Commissioning of 18W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro/Panasonic). |
| 37 | Supply, Installation, Testing and Commissioning of 50W (Havells/ PhillIps/Wipro skyline ) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w ,CRI>80 ,CCT>5000 ,Avg Life L70 50000 hours ,No haremful UV and IR radiators, Operating Temp -10 to 45C ,Surge Voltage Protection, IP66 Protection and impact resistance of IK07.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. |
| 38 | Supply, installation, testing and commissioning of 1200 mm (48”) BEE Star rated energy-efficient ceiling fan, complete with 3 Nos. aluminum blades, downrod, canopy, capacitor, safety pin, nuts, bolts and washers, suitable for 230 V, 50 Hz AC supply. The fan shall have air delivery not less than 220 m³/min, rated speed (RPM) between 340–380 (as per manufacturer’s specification), power consumption not exceeding 50 watts, service value ≥ 6.0, noise level ≤ 60 dB, insulation class ‘B’ and insulation resistance > 2 MΩ. Fan shall be of approved make such as Usha / Havells / Crompton / Orient or equivalent, including installation, online RPM verification, testing, commissioning and handing over to the Engineer-in-Charge, with minimum 2-year manufacturer warranty. |
| 39 | Supplying and fixing ISI-marked 6 A, 250 V modular step-type electronic fan regulator (2 Module), conforming to IS:3854 or latest IS standards, mounted on suitable modular plate with GI flush box, including wiring connections, testing and commissioning, of approved make such as Anchor Roma / Legrand / Schneider / Havells, complete as per direction of the Engineer-in-Charge. |
| 40 | Supply, Installation, Testing and Comm. Of 200/250mm sweep exhaust fan Shutter type of havell /Bajaj/ Crompton/equivalent make as directed by engineer incharge,Air Flow capacity >850cmph, 35-50Watts,Noise level 44db, 1200 rpm,water resistant, including making of space in wall/ window as per site requirement and necessary connections.The job includes replacement warranty of fixture if damaged/burn out what so ever reason for a period of two years reckoned from the date of sucessful commissioning / handing over of site to the intending department.(To be got approved before installation from EIC) |
| 41 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make). |
| 42 | Supplying and fixing of GI box along with modular base and cover plate for modular sockets, switches in recess etc as required6 module (200mm x 75mm) |
| 43 | Supplying and fixing of 5pin 5-10A socket and 5-10A switch on existing modular plate, incl connections etc as required. (Havells/SSK/Anchor/ABB/Schneider) |
| 44 | Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required.(Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) including the cost of conduit. |
| 45 | Wiring for 5-10A socket out lets for computer with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required including the cost of conduit. |
| 46 | Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent). |
| 47 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired. |
| 48 | Supply and fixing of 6 way (4+18), Double door surface/ recess mounting, Horizontal type,three pole and neutral, sheet steel, MCB distribution board ,415V, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB) |
| 49 | Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V,10 KA \"C\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCBdistribution board complete with necessary connections. |
| 50 | Supply, installation, testing and commissioning of 32-40A DP rating 240/415V,10 KA \"C\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 51 | Supply, installation, testing and commissioning of 63A DP rating 240/415V,10 KA \"C\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 52 | Main PanelDesign, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required. (As per approved design,size may vary as per site requirement) |
| 53 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.1. Normal INCOMING:a)125A DP MCB 10 KA Havells/Legrand/ Schinider/ABB/L&T sample to be approved before installation.. |
| 54 | b) 4 No. of Aluminium Bus Bar of 300 Amp. |
| 55 | c)Digital meters and phase indicators -1 set. |
| 56 | 3.INVERTER a) 32A DP MCB 10KA |
| 57 | b) 2 No. of Aluminium Bus Bar of 63 Amp. |
| 58 | c) Digital meter and phase indicators 01 set. |
| 59 | Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, including the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent).2x10 sq mm +1x6 sq mm Heating submain |
| 60 | 2x 6 sq mm + 1x 6 sq mm Inverter Lighting submain |
| 61 | 2x 4 sq mm + 1x 4 sq mm Lighting submain |
| 62 | 2x 2.5 sq mm + 1x 2.5 sq mm Lighting circuit |
| 63 | Supply, installation, testing and commissioning of 1600-2000 VA, 12 V, single-phase pure sine wave inverter with inbuilt charger and automatic changeover, conforming to IS 16242/IEC standards, including supply of 2 Nos. 12 V, 200 Ah tall tubular lead-acid batteries (IS 13369/IS 1651) mounted on PVC/FRP battery trolley, complete with interconnecting cables, terminals, DC fuse/isolator, AC wiring to DB, initial charging, commissioning, and all accessories, duly approved by Engineer-in-Charge. |
| 64 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.Complete Job. |
| 65 | Providing and laying earth connection from earth electrode with 8 mm dia copper wire in 15 mm dia G.l. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 66 | Supply, laying, connecting and commissioning of 35 sq mm 2 core XLPE/ PVCInsulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped. (Over head/ under ground). Please Enable Macros to View BoQ information |