| 1 | GROUND FLOOR |
| 2 | Earth work in excavation of foundation in hard soil or gravelly soil with all lead & lift including dressing & levelling the bed of the foundation to the required width & depth & stacking the excavated materials away from the working areas etc.complete as per the direction of the Engineer-in-Charge. |
| 3 | Providing and filling clean dry sand of approved quality from approved quarry in foundation and plinth in 9\" thick layer well watered and rammed incl. cost,conveyance, royalties and taxes of all materials etc.complete as per the direction of the Engineer-in-Charge. |
| 4 | Cement concrete M15 Grade with crushed granite coarse aggregarate 40mm down graded of approved quality mixed by concrete mixer and placing manually, compacting with vibrators including cost of all materials, labour charges with transportion of materials and placement within initial lead of 50m and initial lift of 1.50m for mixed concrete complete as directed by Engineer-in-charge. |
| 5 | R.C.C. work of M-20 grade with 20mm and down grade crushed granite coarse aggregarate 20mm down graded of approved quality mixed by concrete mixer and placing manually, compacting with vibrators including form work, centering and shuttering with cost of all materials, labour charges with transportion of materials and placement within initial lead of 50m and initial lift of 1.50m for mixed concrete complete as directed by Engineer-in-charge. |
| 6 | Column Raft foundation |
| 7 | Plinth Band |
| 8 | Column and Beam |
| 9 | Lintel Band |
| 10 | Staircase |
| 11 | Roof slab, Landing |
| 12 | Chajjas |
| 13 | Cutting, straightening, coiled or bent up T. S. rod for R.C.C. work incl. bending, binding & tying the grills and placing in proper position with cost, conveyance,taxes of binding wire 18 to 20 gauge and T.S. rod, cost of all labour & T&P etc complete as per the direction of the Engineer-in-Charge. |
| 14 | Fly Ash Brick masonry in C.M. (1:6) using Fly Ash Brick of size 23cmx1cmx 8cm of crushing strength not less than 75kg/cm2 with dimentional tolerance plus minus 2% after immersing the bricks for six hours befour use incl.lowering, placing in position, watering and curing and cost, conveyance, royalties and taxes of all materials, cost of labour & T&P etc. complete as per the direction of the Engineer-in-Charge. (In foundation and plinth) |
| 15 | Fly Ash Brick masonry in Superstructure in C.M. (1:6) using Fly Ash Brick of size 23cmx11cmx 8cm of crushing strength not less than 75kg/cm2 with dimentional tolerance plus minus 2% after immersing the bricks for six hours befour use incl.lowering, placing in position, watering and curing and cost, conveyance, royalties and taxes of all materials, cost of labour & T&P etc. complete as per the direction of the Engineer-in-Charge. |
| 16 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chipswith cost, conveyance, royalty & taxes of all materials, cost of labour and T&p etc. all complete as per the direction of the Engineer-in-charge. |
| 17 | Supplying, fitting and fixing of M.S. doors, windows and iron grill made out of (45x45x6)mm size angular frame with square bar M.S. flat for grills, 1.0mm CR Sheet with locking arrangement of approved design including all cost, conveyance, taxes etc. complete and as per direction of the Engineer-in-Charge. |
| 18 | Labour for fixing and fitting as M.S. doors, windows and ventilators in proper position and making necessary repair to damage surface including cost, conveyance, royalty, taxes of all materials with all labour etc. complete and as per direction of the Engineer-in-Charge. |
| 19 | 12mm thick cement plaster (1:6) for brick work after racking out joints incl.watering, curing etc. complete with cost, conveyance, royalties & taxes of all materials, labour and T&P etc complete as per the direction of Engineer-in-Charge. |
| 20 | 6mm thick cement plaster (1:4) to RCC surfaces finished smooth including close deep chiping and slury treatment including watering, curing etc. complete with cost, conveyance, royalties & taxes of all materials, labour and T&P etc complete as per the direction of the Engineer-in-Charge. |
| 21 | 16mm thick cement plaster (1:6) for brick or stone masonry work after racking out joints incl.watering, curing etc. complete with cost, conveyance, royalties & taxes of all materials, labour and T&P etc complete as per the direction of Engineer-in-Charge. |
| 22 | Providing and fixing vetrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost, carriage, royality,taxes of all materials with all labour and T&P required etc. complete and as per direction of the Engineer-in-Charge. |
| 23 | Providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost, carriage, royality,taxes of all materials with all labour and T&P required etc. complete and as per direction of the Engineer-in-Charge. |
| 24 | Providing and fixing ceramic tiles in walls on 12mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including cost, carriage, royality,taxes of all materials with all labour and T&P required etc. complete and as per direction of the Engineer-in-Charge. |
| 25 | Providing and fixing Granite Tiles of minimum 10mm thick, above 0.10 sqm & up to 0.40sqm in floors, treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost, carriage, royality,taxes of all materials with all labour and T&P required etc. complete and as per direction of the Engineer-in-Charge. |
| 26 | Providing fitting and fixing of false ceilling with 12.5 mm thick gypsum board of size 6\"x 4\" fitted with Aluminium anodised T Section No. 3215 with 2\"-0\" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2\"-0\"x2\"-0\" suspended from ceiling etc complete as per specification and direction of department. |
| 27 | Finishing wall surface of wall with Acrylic wall putty (water based) of approved make and finished smooth and even surface incuding cost, carriage etc. all complete as per direction of the the Engineer-in-charge. |
| 28 | Supplying, fitting, fixing fully glazed aluminium framed openable windows using 15 micron enodized OEL aluminium section 2082 as out section, 9139 as million section, 4124 as shutter section frame with tapered clip of section 4125, aluminium angle, rubbers bending, friction stay and handle etc. with with 5mm black glass. |
| 29 | Supplying, fitting, fixing of Aluminium door with OEL onodized Al. door section 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member and 12mm thick pre-laminated board fixed on door frame by means of tapered clip No. 4660 and the frame to be completed by means of jointing angle No. 1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc. complete. |
| 30 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railing in all floors using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2 mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete in all respect. |
| 31 | Painting two coats with approved paint to doors and windows over a coat of primer incl. cost of all material,T&P and labour etc complete.( for Iron work) as per direction of the Engineer-In-charge. |
| 32 | Wall painting two coats with plastic emulsion paint of approved shade to give an even shade over a coat of primer to give an even shade with approved paint inlcuding cost, conveyance, royalty, taxes of all materials with all labour, T&P required etc. complete as per the direction of the Engineer-In-charge. |
| 33 | Finishing walls with weather coat painting two coats of approved shade over a coat of primer to give an even shade with approved paint inlcuding cost, conveyance, royalty, taxes of all materials with all labour, T&P required etc. complete as per the direction of the Engineer-In-charge. |
| 34 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, complete as per manufacturer’s specification and direction of Engineer- in-Charge. |
| 35 | Providing and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-incharge. |
| 36 | Providing and fixing ISI marked 32mm thick flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both face of shutters of approved design including cost of all door fittings and fixtures etc. complete as per direction of Engineer-incharge. |
| 37 | Providing and fixing skirting with 25 mm thick Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete as per direction of Engineer-in-charge. |
| 38 | FIRST FLOOR |
| 39 | R.C.C. work of M-20 grade with 20mm and down grade crushed granite coarse aggregarate 20mm down graded of approved quality mixed by concrete mixer and placing manually, compacting with vibrators including form work, centering and shuttering with cost of all materials, labour charges with transportion of materials and placement within initial lead of 50m and initial lift of 1.50m for mixed concrete complete as directed by Engineer-in-charge. |
| 40 | Column and Beam |
| 41 | Lintel Band |
| 42 | Staircase |
| 43 | Roof slab, Landing |
| 44 | Chajjas |
| 45 | Cutting, straightening, coiled or bent up T. S. rod for R.C.C. work incl. bending, binding & tying the grills and placing in proper position with cost, conveyance,taxes of binding wire 18 to 20 gauge and T.S. rod, cost of all labour & T&P etc complete as per the direction of the Engineer-in-Charge. |
| 46 | Fly Ash Brick masonry in Superstructure in C.M. (1:6) using Fly Ash Brick of size 23cmx11cmx 8cm of crushing strength not less than 75kg/cm2 with dimentional tolerance plus minus 2% after immersing the bricks for six hours befour use incl.lowering, placing in position, watering and curing and cost, conveyance, royalties and taxes of all materials, cost of labour & T&P etc. complete as per the direction of the Engineer-in-Charge. |
| 47 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chipswith cost, conveyance, royalty & taxes of all materials, cost of labour and T&p etc. all complete as per the direction of the Engineer-in-charge. |
| 48 | Supplying, fitting and fixing of M.S. doors, windows and iron grill made out of (45x45x6)mm size angular frame with square bar M.S. flat for grills, 1.0mm CR Sheet with locking arrangement of approved design including all cost, conveyance, taxes etc. complete and as per direction of the Engineer-in-Charge. |
| 49 | Labour for fixing and fitting as M.S. doors, windows and ventilators in proper position and making necessary repair to damage surface including cost, conveyance, royalty, taxes of all materials with all labour etc. complete and as per direction of the Engineer-in-Charge. |
| 50 | 12mm thick cement plaster (1:6) for brick work after racking out joints incl.watering, curing etc. complete with cost, conveyance, royalties & taxes of all materials, labour and T&P etc complete as per the direction of Engineer-in-Charge. |
| 51 | 6mm thick cement plaster (1:4) to RCC surfaces finished smooth including close deep chiping and slury treatment including watering, curing etc. complete with cost, conveyance, royalties & taxes of all materials, labour and T&P etc complete as per the direction of the Engineer-in-Charge. |
| 52 | 16mm thick cement plaster (1:6) for brick or stone masonry work after racking out joints incl.watering, curing etc. complete with cost, conveyance, royalties & taxes of all materials, labour and T&P etc complete as per the direction of Engineer-in-Charge. |
| 53 | Providing and fixing vetrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost, carriage, royality,taxes of all materials with all labour and T&P required etc. complete and as per direction of the Engineer-in-Charge. |
| 54 | Providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost, carriage, royality,taxes of all materials with all labour and T&P required etc. complete and as per direction of the Engineer-in-Charge. |
| 55 | Providing and fixing ceramic tiles in walls on 12mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including cost, carriage, royality,taxes of all materials with all labour and T&P required etc. complete and as per direction of the Engineer-in-Charge. |
| 56 | Providing and fixing Granite Tiles of minimum 10mm thick, above 0.10 sqm & up to 0.40sqm in floors, treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost, carriage, royality,taxes of all materials with all labour and T&P required etc. complete and as per direction of the Engineer-in-Charge. |
| 57 | Providing fitting and fixing of false ceilling with 12.5 mm thick gypsum board of size 6\"x 4\" fitted with Aluminium anodised T Section No. 3215 with 2\"-0\" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2\"-0\"x2\"-0\" suspended from ceiling etc complete as per specification and direction of department. |
| 58 | Finishing wall surface of wall with Acrylic wall putty (water based) of approved make and finished smooth and even surface incuding cost, carriage etc. all complete as per direction of the the Engineer-in-charge. |
| 59 | Supplying, fitting, fixing fully glazed aluminium framed openable windows using 15 micron enodized OEL aluminium section 2082 as out section, 9139 as million section, 4124 as shutter section frame with tapered clip of section 4125, aluminium angle, rubbers bending, friction stay and handle etc. with with 5mm black glass. |
| 60 | Supplying, fitting, fixing of Aluminium door with OEL onodized Al. door section 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member and 12mm thick pre-laminated board fixed on door frame by means of tapered clip No. 4660 and the frame to be completed by means of jointing angle No. 1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc. complete. |
| 61 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railing in all floors using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2 mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete in all respect. |
| 62 | Painting two coats with approved paint to doors and windows over a coat of primer incl. cost of all material,T&P and labour etc complete.( for Iron work) as per direction of the Engineer-In-charge. |
| 63 | Wall painting two coats with plastic emulsion paint of approved shade to give an even shade over a coat of primer to give an even shade with approved paint inlcuding cost, conveyance, royalty, taxes of all materials with all labour, T&P required etc. complete as per the direction of the Engineer-In-charge. |
| 64 | Finishing walls with weather coat painting two coats of approved shade over a coat of primer to give an even shade with approved paint inlcuding cost, conveyance, royalty, taxes of all materials with all labour, T&P required etc. complete as per the direction of the Engineer-In-charge. |
| 65 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, complete as per manufacturer’s specification and direction of Engineer- in-Charge. |
| 66 | Providing and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-incharge. |
| 67 | Providing and fixing ISI marked 32mm thick flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both face of shutters of approved design including cost of all door fittings and fixtures etc. complete as per direction of Engineer-incharge. |
| 68 | Providing and fixing skirting with 25 mm thick Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete as per direction of Engineer-in-charge. |
| 69 | SECOND FLOOR |
| 70 | R.C.C. work of M-20 grade with 20mm and down grade crushed granite coarse aggregarate 20mm down graded of approved quality mixed by concrete mixer and placing manually, compacting with vibrators including form work, centering and shuttering with cost of all materials, labour charges with transportion of materials and placement within initial lead of 50m and initial lift of 1.50m for mixed concrete complete as directed by Engineer-in-charge. |
| 71 | Column and Beam |
| 72 | Lintel Band |
| 73 | Roof slab, Landing |
| 74 | Chajjas |
| 75 | Cutting, straightening, coiled or bent up T. S. rod for R.C.C. work incl. bending, binding & tying the grills and placing in proper position with cost, conveyance,taxes of binding wire 18 to 20 gauge and T.S. rod, cost of all labour & T&P etc complete as per the direction of the Engineer-in-Charge. |
| 76 | Fly Ash Brick masonry in Superstructure in C.M. (1:6) using Fly Ash Brick of size 23cmx11cmx 8cm of crushing strength not less than 75kg/cm2 with dimentional tolerance plus minus 2% after immersing the bricks for six hours befour use incl.lowering, placing in position, watering and curing and cost, conveyance, royalties and taxes of all materials, cost of labour & T&P etc. complete as per the direction of the Engineer-in-Charge. |
| 77 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chipswith cost, conveyance, royalty & taxes of all materials, cost of labour and T&p etc. all complete as per the direction of the Engineer-in-charge. |
| 78 | Supplying, fitting and fixing of M.S. doors, windows and iron grill made out of (45x45x6)mm size angular frame with square bar M.S. flat for grills, 1.0mm CR Sheet with locking arrangement of approved design including all cost, conveyance, taxes etc. complete and as per direction of the Engineer-in-Charge. |
| 79 | Labour for fixing and fitting as M.S. doors, windows and ventilators in proper position and making necessary repair to damage surface including cost, conveyance, royalty, taxes of all materials with all labour etc. complete and as per direction of the Engineer-in-Charge. |
| 80 | 12mm thick cement plaster (1:6) for brick work after racking out joints incl.watering, curing etc. complete with cost, conveyance, royalties & taxes of all materials, labour and T&P etc complete as per the direction of Engineer-in-Charge. |
| 81 | 6mm thick cement plaster (1:4) to RCC surfaces finished smooth including close deep chiping and slury treatment including watering, curing etc. complete with cost, conveyance, royalties & taxes of all materials, labour and T&P etc complete as per the direction of the Engineer-in-Charge. |
| 82 | 16mm thick cement plaster (1:6) for brick or stone masonry work after racking out joints incl.watering, curing etc. complete with cost, conveyance, royalties & taxes of all materials, labour and T&P etc complete as per the direction of Engineer-in-Charge. |
| 83 | Finishing wall surface of wall with Acrylic wall putty (water based) of approved make and finished smooth and even surface incuding cost, carriage etc. all complete as per direction of the the Engineer-in-charge. |
| 84 | Supplying, fitting, fixing fully glazed aluminium framed openable windows using 15 micron enodized OEL aluminium section 2082 as out section, 9139 as million section, 4124 as shutter section frame with tapered clip of section 4125, aluminium angle, rubbers bending, friction stay and handle etc. with with 5mm black glass. |
| 85 | Painting two coats with approved paint to doors and windows over a coat of primer incl. cost of all material,T&P and labour etc complete.( for Iron work) as per direction of the Engineer-In-charge. |
| 86 | Wall painting two coats with plastic emulsion paint of approved shade to give an even shade over a coat of primer to give an even shade with approved paint inlcuding cost, conveyance, royalty, taxes of all materials with all labour, T&P required etc. complete as per the direction of the Engineer-In-charge. |
| 87 | Finishing walls with weather coat painting two coats of approved shade over a coat of primer to give an even shade with approved paint inlcuding cost, conveyance, royalty, taxes of all materials with all labour, T&P required etc. complete as per the direction of the Engineer-In-charge. |
| 88 | SEPTIC TANK |
| 89 | Earth work in excavation of foundation in hard soil or gravelly soil with all lead & lift including dressing & levelling the bed of the foundation to the required width & depth & stacking the excavated materials away from the working areas etc.complete as per the direction of the Engineer-in-Charge. |
| 90 | Providing and filling clean dry sand of approved quality from approved quarry in foundation and plinth in 9\" thick layer well watered and rammed incl. cost,conveyance, royalties and taxes of all materials etc.complete as per the direction of the Engineer-in-Charge. |
| 91 | Cement concrete M15 Grade with crushed granite coarse aggregarate 40mm down graded of approved quality mixed by concrete mixer and placing manually, compacting with vibrators including cost of all materials, labour charges with transportion of materials and placement within initial lead of 50m and initial lift of 1.50m for mixed concrete complete as directed by Engineer-in-charge. |
| 92 | R.C.C. work of M-20 grade with 20mm and down grade crushed granite coarse aggregarate 20mm down graded of approved quality mixed by concrete mixer and placing manually, compacting with vibrators including form work, centering and shuttering with cost of all materials, labour charges with transportion of materials and placement within initial lead of 50m and initial lift of 1.50m for mixed concrete complete as directed by Engineer-in-charge. |
| 93 | Roof slab, Landing |
| 94 | Cutting, straightening, coiled or bent up T. S. rod for R.C.C. work incl. bending, binding & tying the grills and placing in proper position with cost, conveyance,taxes of binding wire 18 to 20 gauge and T.S. rod, cost of all labour & T&P etc complete as per the direction of the Engineer-in-Charge. |
| 95 | Fly Ash Brick masonry in C.M. (1:6) using Fly Ash Brick of size 23cmx1cmx 8cm of crushing strength not less than 75kg/cm2 with dimentional tolerance plus minus 2% after immersing the bricks for six hours befour use incl.lowering, placing in position, watering and curing and cost, conveyance, royalties and taxes of all materials, cost of labour & T&P etc. complete as per the direction of the Engineer-in-Charge. (In foundation and plinth) |
| 96 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chipswith cost, conveyance, royalty & taxes of all materials, cost of labour and T&p etc. all complete as per the direction of the Engineer-in-charge. |
| 97 | Honey comb masonry with 23cm ×11cm ×8cm size fly ash bricks having crushing strength not less than 75kg/cm² in cement mortrar (1:4) and plastered with 16mm, thick cement mortar (1:6) including weather coat 2 coats including lowering, placing in position, watering and curing and cost, conveyance, royalties and taxes of all materials, cost of labour & T&P etc. complete as per the direction of Engineer-in charge |
| 98 | 12mm thick cement plaster (1:4) for brick work after racking out joints incl.watering, curing etc. complete with cost, conveyance, royalties & taxes of all materials, labour and T&P etc complete and as per direction of the Engineer-in-Charge. |
| 99 | Granite Metal back filling 4.5cm size in soak pit including cost conveyance of all materials etc complete with cost, conveyance, royalty & taxes of all materials, cost of labour and T&P etc. all complete and as per direction of the Engineer-in-Charge. |
| 100 | Finishing walls with weather coat painting two coats of approved shade over a coat of primer to give an even shade with approved paint inlcuding cost, conveyance, royalty, taxes of all materials with all labour, T&P required etc. complete as per the direction of the Engineer-In-charge. |
| 101 | Supplying and laying in trenches 110mm dia rigid unplasticised PVC pipes conforming to IS 4985-2000 and Specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by non heat application method including testing as per specification etc all complete & as per the specification & direction of the Engineer-in-Charge. |
| 102 | Internal Electrical Installation & PH Works Please Enable Macros to View BoQ information |