| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris to outside the station where suitable for contractor complete all as specified and as directed. |
| 2 | Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for and disposal of debris to outside the station where suitable for contractor complete all as specified and directed. |
| 3 | M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 25mm thick cement concrete type B-1 1:2:4 (20mm graded stone aggregate) and over 15 mm thick screed bed or bedding layers in CM 1:6jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 4 | M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar (Kota Stone laid in staircase should be in single piece with rounding nosing) laid on vertical surface over and including 10 mm thick backing coat in CM 1:4 including rubbing and polishing complete all as specified and directed. |
| 5 | M&L for 75mm thick cement concrete type D-2 1:4:8 (40mm graded stone aggregate) sub base for kota stone, hard standing or paths including necessary formwork laid in panels complete all as specified and as directed. |
| 6 | M&L for 75mm thick cement concrete type B-1 1:2:4(20mm graded stone aggregate)for hard standingor path including necessary formwork complete all as specified and as directed. |
| 7 | M & L for treating the soil under plinth protection at the rate of 5 litres of emulsion per Sqm of surface area,(with 20% EC) complete all as specified and as directed. |
| 8 | M & L for ATT along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed. |
| 9 | Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and as directed. |
| 10 | M&L for 15mm thick cement plaster in 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement mixed with WPC @ of 3% of weight of cement complete all as specified and as directed.Note : WPC shall be measured and paid separately. |
| 11 | M & L for rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfacesfinished even and smooth without using extra cement complete all as specified and as directed.Note : WPC shall be measured and paid separately. |
| 12 | M&L for plastering 5mm thick, trowelled to even and smooth finish in cement mortar 1;2 in ceiling complete all as specified and as directed. |
| 13 | Supply only Integral Water Proofing Compound complete all as specified and as directed. |
| 14 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemperon wall over one coat of primer incl one layer of 3mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and as directed. |
| 15 | M & L for preparing new plastered or concrete surfaces of ceiling& applying 3 coats of white wash in celing complete all as specified and as directed. |
| 16 | M & L preparation of new plastered surfaces on walls and applying two coats of cement based paint over a coat of primer (alkali resistant priming paint) complete all as specified and directed. |
| 17 | M&L for preparation of new surfaces of steel of any description, n exc 10cm in width or girth, applying two coats of synthetic enamel paint over a coat of zinc chromium primercomplete all as specified and as directed. |
| 18 | Demolition of existing roof treatment (including PCC , plaster / brick tiles, mud etc) of any description and thickness upto roof slab on roof top including flashing and junction of parapet repair and disposal of debris to outside the station where suitable for contractor complete all as specified and as directed. |
| 19 | M&L for PCC 1:2:4type B-0 using 12.5 mm graded stone aggregate on RCC roof slabs to fill undulations to achieve uniform slope complete all as specified and as directed. |
| 20 | M&L for rendering over roof slab 10 mm thick in CM 1:4 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement and finished surfaces fair and even complete all as specified and as directed.Note : WPC shall be measured and paid separately. |
| 21 | M&L for APP based modified pre fabricated five layer, 3 mm thick and weighing not less than 3.5 Kg per Sqm water proofing membrane reinforced with non woven polyester mat 160 G Smith black finished over compatible primer conforming to IS-3488 @ 0.3 LT/Sqm, membrane laid by torch application side over lap of 75 mm and end overlap of 100 mm wide, joint/overlap sealed with torch applications for parapet etc the membrane taken up to 30 cm and then inserted inside the parapet after making necessary groove as required after necessary preparation of the surface comlete as per manufacturer\"s instruction complete all as specified and as directed. |
| 22 | M&L for applying two coat of aluminium paint over the roof ( APP membrane) complete all as specified and as directed. |
| 23 | M&L for mil steel Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc also fastening and fixing complete(Fe 410-w (gde-E-250)quality A) complete all as specified and as directed. |
| 24 | M&L for prepartion of new surface of steel work of any description not specifically mentioned otherwise over 10 cm width or girth & applying two coat of synthetic enamal paint over one coat of red oxide primer complete all as specified and as directed. |
| 25 | S&F Pre painted GalvaIume aluminium zinc coating GI based corrugated steel sheet0.50 mm thick of any colour as directed by Engr-in-Charge, having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws etc complete all as specified and directed. |
| 26 | M&L for factory made box type steel windows, 16 gauge steel section for frames & shutters,type using ERW hollow \"P\" section comprising double frame for glazed and gauged skelton shutters jointed internally with flat iron 40X4 mm complete including MS grill of 12 mm square bar, fixed horizontally @ 10 cm centre to centre, pintel hinges 75 mm long 12 mm dia, 100 mm long handle, 150 mm long tower bolts, lugs etc. with/ without cooler provision, complete all as specified and directed by Engineer-in-Charge. Note :- (i) Glazing and wire mesh shallbe measured and paid for separately in respective of item. |
| 27 | S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed in wooden/steel/Aluminium windows, or Stainless steel wire staples complete all as specified and as directed. |
| 28 | S&F sheet glass ordinary quality 3mm thick with oil putty or beads fixed with screws in sequence not exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 29 | M&L PCC1:2:4 type B-1 using 20 mm graded stone aggregate as in coping including weathering round or chamfered and necessary form work required complete all as specified and as directed. |
| 30 | S&F 1.25mm thick Steel rolling shutters, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manualtype incl taking down rolling shutters complete all as specified and as directed. |
| 31 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing),and rubbish off the premises complete all as specified and directed. |
| 32 | M&L for Glazed ceramic coloured tiles 300x450x 7mm thick on vertical surfaces of wall set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick rendering in CM (1:4) backing of wall tiles such as dado/skirting in vertical surface complete all as specified and as specified. |
| 33 | M&L for applying the polymer plaster to ceiling using anti rust removal for reinforcement; step by step complete all as specified and as directed.STEP 1-Removing the loose or damaged plaster till a sound surface is reachedSTEP 2-Applying a thin layer of plaster for joint compound to the area and press the fibre mesh tape into wet plaster starting from the centre and working outwards to remove any bubbles or gaps.STEP 3-Allow the first coat to dry then apply another coat of plaster over the mesh.Apply additional coat if needed and allowing each coat to dry before applying the next one. |
| 34 | M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed. |
| 35 | Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed . |
| 36 | M&L for Brickwork with subclass \"B\" bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed. |
| 37 | All as per item No 36 above but except bricks. |
| 38 | M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and as directed. |
| 39 | M&L for fully vitrified tiles light/dark shade 9-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors, shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles, over & including 15 mm thick bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and as directed. |
| 40 | M&L for PVC hollow panelling 5 to 8 mm thick on ceilling with necessary frame work inDesign POPUP pattern and any colour approved by engr-in-charge,inclusive of fixing on to ceiling incl moulding end caps fixed with PVC sleeves and screws as requiredat site complete all as specified and directed |
| 41 | M&L in repair for PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge,inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as requiredat site complete all as specified and directed |
| 42 | M&L for fixing GYM Rubberised tiles V-Groove Sizes : 600X600mm .Thickness 25mm.Weight perTile : ,25mm-6kg.Colors : Black, Grey, Green, Terracotta, Blue. Material Composition: SBR recycled Rubber crumb with polymerically bonded with Hot Molded Technology. Crumb Rubber Granules Range: 0.8mm to 2mm.Tensile Strength (Mpa) : 1.5 MPacomplete all as specified and directed |
| 43 | M&L for preparation of old/new treated plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt andallloose scales of existing treatment using sand paper andapplying two coats of weather proof exterior emulsion (water based)paint (in camouflage pattern) of dark colours/shade on walls (shade as approved by GE) over 1 coat of water based exterior primer incl one layer of 1mm thick plaster of paris putty to prepare the surface even and smooth for exterior/interior on wall/ceiling surfaces complete all as specified and directed |
| 44 | Taking Down carefully Copper/aluminium Point Wiring (light, fan,socket or Power) complete, including fixture and fittingssuch as switches, ceiling roses, pendents, regulators sockets etc, removing materials to store for keeping in safe custody or for taking credit as per condititions seperately and making good disturbed surfaces of walls, floors etc complete all as specified and directed |
| 45 | M&L for point wiring complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn throughand includingrigid non metallic PVC heavy duty concealed conduit(min 20 mm dia (external) medium grade but shall be increased as per actual site requirement in accordance with clause 19.12.5 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories likebends.tees, juction boxes etc fixed concealed in wall/ceiling or surface conduit on ceiling with provision of 2 mm thick pressed steel terminalboxes covered with 3 mm thick plastic laminatedwhite /coloured top cover for mounting switch,socket,fan regulator,industrial socket and all lamp fittings etc including 1.5 sq mm PVC insulated unsheathed copper conductor FRLS cable,1100 volt grade IS-694 marked as earth contuinity wire for one light/Fan point controlled by one,one way switch complete all as specified and directed |
| 46 | Allas per itemNo 45 above but on the same boardwith other switches with 1.5 sq mmPVC insulated copper conductor for continuous earthing complete. |
| 47 | Allas per itemN0 45 above but one three pin 5 Amps socket out let on independant board with1.5 sq mmPVC insulated copper conductor for continuous earthing complete. |
| 48 | Allas per item No 45 above but 15 Amps3 pinsocket outleton independent board with 2.5 sq mmPVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single corefor continuous earthing complete. |
| 49 | M&L in repairs, two single core PVC insulated cable with copper conductor multi stranded 4 Sqmm in and incl. duly drawn through and including concealed PVC conduit 25mmmedium grade ISI marked as sub main with continuous earth wire 4 Sqmm size and connecting to common earth dolly complete all as specified and directed.(Flexible Copper Wire Used In FRLS) Note : 03 run of 04 sqmm cable and one run of PVC conduit will be measured as one running meter for the purpose of measurement and payment. |
| 50 | M&L in repairs, two single core PVC insulated cable with copper conductor multi stranded 6 Sqmm in and incl. duly drawn through and including concealed PVC conduit 32mm medium grade ISI marked as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly complete all as specified and directed(Flexible Copper Wire Used In FRLS) Note : 03 run of 06 sqmm cable and one run of PVC conduit will be measured as one running meter for the purpose of measurement and payment. |
| 51 | S&F Piano switch, flush button single pole one way 6 Amp complete all as specified and directed |
| 52 | S&F bell push, flush type 5 Amps complete all as specified and directed |
| 53 | S&F socket outlet, flush type 2 in 1, 3 pin 6 Amp complete all as specified and directed |
| 54 | S&F socket outlet, flush type 2 in 1, 3 pin and 6/16 Amp complete all as specified and directed |
| 55 | S&F Piano switch, flush button single pole one way 16 Amp complete all as specified and directed |
| 56 | S&Fstepped type electronic fan regulator, flush type on the existing phenolic laminated sheet etc complete all as specified and directed |
| 57 | S&F as in repair distribution board iron clad, double door with IP-54, 1K-09 protection suitable for MCCB as incomer and MCB as outgoing 415 V, 3 Phase, 50Hz, 4 way, double door complete with appropriate size copper bus bar and neutral link, complete with one MCCB, 3 pole, 415 V 100 Amp, 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or complete all as specified and directedNote: Outgoing MCB will be paid seprately |
| 58 | S&Fin repairs,MCB SP 6-32 Amps,\"B\" series 240 Volts complete all as specified and directed |
| 59 | S & Fin repairs,MCB SPN 32 Amps,\"B\" series 240 Volts complete all as specified and directed |
| 60 | S&Fin repairs,ceiling rose surface backlight, 65 x 50 mm three terminals complete all as specified and directed |
| 61 | S & F in repairs Bell Multi Music type, 240 Volts complete all as specified and directed |
| 62 | Supply and fixing LED , Tube light fitting 20 W, 6500K Intenso AX LED batten aluminium profile self ballasted surface mounted LED Batten extruded aluminium body with PC diffuser in unic shape. >180º wide light distribution. soft glare free light complete accessories prewired and including provision of three core textile braided copper conductor flexible wire from ceiling rose to light fitting complete all as specified and directed |
| 63 | Taking down carefullyaluminum two core sub main wiring of sizes 6 Sqmm /4 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed |
| 64 | S&F in repair energy efficient LED building secruity lights 1x30W with lens, PDC aluminium body and toughened glass visor fitted in frame secondary optical lens for superior light distribution efficay >100 Lm/W, CCT 5700K, IP-65 complete with bracket/clamps, nut bolts and washers suitable for fitted in building complete all as specified and directed |
| 65 | S&F exhaust fan heavy duty metal body with louvers of size 300mm sweep, 1400 RPM and fixing arrangements complete all as specified and directed |
| 66 | Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed |
| 67 | Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cmapart complete all as specified and directed |
| 68 | Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed |
| 69 | Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed |
| 70 | Supply and Laying precast concrete cover class LV type 1 flat size 250mm x150mm x40mm laid in trenches for cable protection complete all as specified and directed |
| 71 | Supply, Laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed |
| 72 | M & L in repairs earthing complete with galvanised steel earth plate electode 600 x 600 x 6.0 mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to & including galvanised steel wire 4.0 mm diasize means of nuts and bolt check nuts and washers of galvanised rion sheet all as shown in electrical plate Nos 3 of SSR Part - I and connected to earthing test point complete including testing filling of adquate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil upto 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 50 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made out of8 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed |