| 1 | Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed. |
| 2 | S&F in renewal sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 3 | S&F in renewal sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 4 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 4 | Taking down unserviceable Sheet metal box & MCB DB TPN/VTPN with MCB\"s of any make/capacity, complete all as specified and directed. |
| 5 | S&F in renewal sheet metal enclosure double door for distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 100 Amp,4 pole & Including MCCB 100 amps 4 pole 16 KA complete. (when MCB\"s are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making goodthe distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 6 | S&F in renewal MCB DB, sheet metal enclosures double door TPN 4 way with bus bar 415 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed. |
| 7 | S&F in renewal MCB TPN 63 Amps, 415 volts \"C\" series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed. |
| 8 | Taking down unserviceable Sheet metal box,Single pole and neutral encloser with top & MCB DB SPN with MCB\"s of any make/capacity, complete, all as specified and directed. |
| 9 | S&F in renewal sheet metal box Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp complete all as specified and directed. |
| 10 | S&F in renewal MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed |
| 11 | S&F, MCB SPN 40 to 63 Amps, 240 volts \"C\" series 10 KA ,including connection with suitable size copper lugs complete all as specified and directed.. |
| 12 | S&F, MCB SP 6 to 32 Amps,240 volts,\"C\" series 10 KA including connection with suitable size copper lugs.complete all as specified and directed. |
| 13 | M&L in renewal lightening conductor assembly made out of GI pipe medium grade of size 40 mm bore along with welded flange, fixed on the RCC roof of the bldgs with drilling/making hole and provide fastners, rubber washer, to connect air termination & connector for earth strip duly fixed with necessary fastners, nuts bolts & washers in PCC 1:2:4 type B0 45cm x 45cm x45cm complete all as specified anddirected. |
| 14 | S&F in renewal air termination single pointed Aluminium rod 12 mm dia, 300 mm long for lightening conductor complete all as specified and directed. |
| 15 | S&F in renewal test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. Head screw for fixing in wall complete all as specified and directed. |
| 16 | S&F in renewal overlap jointing of addl requirements of Aluminium strips by making drilling holes 02 Nos with brass/GI nuts, bolts and lead washers complete as required as per materials complete all as specified and directed. |
| 17 | S&F in renewal porcelain insulator of required size not exceeding than 10 cm long with two nos hole each on both end for fixing properly with fastner, nuts & bolts on wall & roof of buildings for separated earthing stirp from building all as required at site complete all as specified and directed.Note : (i) Water leak protection has to be ensured, Pure Resin based Chemical anchoring system. |
| 18 | S&F in renewal GI pipe medium grade of size 40 mm bore for erection of lightening conductor complete as requiredcomplete all as specified and directed. |
| 19 | S&F in renewal Aluminium strip 25 x 3.15 mm with saddles and fixing screw etc. for roof conductors above ground & wall/batten or recessed or buried in ground complete all as specified and directed. |
| 20 | S&F in renewal Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised steel wire complete all as specified and directed. |
| 21 | S&F in renewal Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x 6 mm dia galvanised iron Strip complete all as specified and directed. |
| 22 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm or GI Strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4)type B-1 (using 20mm graded BTstone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in \"D\" shape 500 mm legth grouted in wall complete all as specified and directed. |
| 23 | Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed. |
| 24 | M&L, concealed point wiring with PVC insulated and unsheathedelectric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No)not less than 20 mm diawith all fitting and fixing accessories and1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes/modular flush boxfactory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint insidefor mounting switches. sockets etc NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface complete for the following:- |
| 25 | One tubelight point controlled by one switch. |
| 26 | One bulb point controlled by one switch. |
| 27 | One Ceiling fan point controlled by one switch. |
| 28 | One Exhaust fan point controlled by one switch. |
| 29 | One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch. |
| 30 | One 3 pin/5 pin switch socket outlet, 5 Amps on independent board. |
| 31 | One Bell/Buzzer point controlled by one way 5 Amp push button switch. |
| 32 | For one light pointcontrolled by 2- two way switch |
| 33 | Description all as per item No 24 here in before but point wiring with 2.5 sqmm FRLSH H confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface complete all as specified and directed. |
| 34 | S&F Modular switch 1 way 6A,1 module complete all as specified and directed. |
| 35 | S&F Socket, 6A - 2/3 pin combined 2 module,complete all as specified and directed. |
| 36 | S&F Modular switch 1 way 16A,1 module 15 Amp complete all as specified and directed. |
| 37 | S&F Socket 6A/16A - 6 pin combined 2 module complete all as specified and directed. |
| 38 | S&F modular bell push flush type, 5 Amps complete all as specified and directed. |
| 39 | S&F Modular switch 2 way 6A, 1 module complete all as specified and directed. |
| 40 | S&F modular Fan step regulator,100 to 120W - 2 module 240 volts, AC 50Hz complete all as specified and directed. |
| 41 | S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed. |
| 42 | S&FLamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings ISI Marked complete all as specified and directed. |
| 43 | S&FModular White cover plate with frame of 2/3/4 module size including fixing modular socket/socket etc complete all as specified and directed. |
| 44 | S&FModular White cover plate with frame of 6/8/12 module size including fixing modular socket/socket etc complete all as specified and directed. |
| 45 | S&F in renewal Decorative ultra slim LED Tubelight fitting of LEDwith extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500K to 4000k as per direction of engr-in-charge ,luminous efficiency 100 lm/wattfitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor forelectrical connection with white insulation tape from ceiling rose to connector of LED fitting including taking down of oldu/s light and testing on completion all as specified and directed. |
| 46 | S&F in renewal Rechargable emergency Invertor type LED Tubelight fitting of LEDwith Backup Time up to 4 hours,powerful 2600mAh Lithium Ion battery, extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500K to 4000k as per direction of engr-in-charge ,luminous efficiency 100 lm/wattfitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor forelectrical connection with white insulation tape from ceiling rose to connector of LED fitting including taking down of oldu/s light and testing on completion all as specified and directed. |
| 47 | S&F in renewal Ding Dong bell, AC, 230 Volts, single pole complete all as specified and directed. |
| 48 | S&F in renewal Switch Socket Combination, 2 in 1, 6 Pin, 6/16 ampscomplete all as specified and directed. |
| 49 | S&F in renewal Switch Socket Combination 6 amp,5 pincomplete all as specified and directed. |