| Sl. No. | Item Description |
| 1 | Demolition ofrein- forced cement concrete (RCC water tanks with platform ) as intop of roofs ,floors (other than ground floors ) beams,stair cases,landings,chajjas and similar suspended works etc, (rein forcement cut as required to facilitate demolition /dismental),including remval of debris complete all as specifed and directed by Engineer-in-Charge. |
| 2 | Dismantling of water tanks exc 500 but n exc1000 ltr capacity and removing to store complete all as specified and directed by Engineer-in-Charge. |
| 3 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layered 1000 ltrs capacity hoisted and fixed in positionincluding 25mm dia float ball brass valve and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified |
| 4 | Disconnecting existing tanks,of capacity 2000lits setting aside or lowering. Cleaning,and re-fixing in position with all fittings,etccomplete all as specified |
| 5 | Completely removal ofexisting water proofing treatment ofany descriptions and in any position (APP membrane, etc) and including demolition concrete paddingwithtop layer of plaster, and rougheningof concrete slab by picking, sweeping clean and washing down with water to remove dust etc and applying evenly cement slurry at the rate of 3kg / sqm over cleaned roof surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Material and labour for PCC 1:2:4 type BO (using 12.50mm graded stone aggregate) for roof,kerbs or mud stops,roundedor chamfered on eds etc including mixing of admixture fosroc SP 430 of M/S Fosroc chemical @ 250ml per 50kg of cement over existing roof and in padding concrete to maintain required slope complete all as specified and as directed by Engineer-in-Charge.Note:- WPC will be measured and paid separetly under respective item. |
| 7 | Supply only of admixture fosroc SP 430 ,Dr fixit Chemical all as specified and as directed by Engineer-in-Charge by the Engineer-in-Charge. |
| 8 | Material and labour for screed bed layer 10 mm thick in CM 1:4 onconcrete surfaces of roof, mixed with integral water proofing compound @ 3% by weight ofcement,finished even and smooth without using extra cementcomplete all asspecified and directed by Engineer-in-Charge. Note:- WPC will be measured and paid separetly under respective item. |
| 9 | Supplyliquidwater proofing compoundmake Fos roc or equivalent make |
| 10 | (i) Material and labour for cleaning the entire roof surface thoroughly to remove all loose particles,dust/dirt particles Apply a coat of oil based bituminous primer 200 gram / square metre on the prepared surface.(ii) Apply a coat of blown type bitumen grade 85/25 conforming to IS:702 heated to a working temperature of 180°C and applied @ 1.20 Kg per square metre of the surface area.(iii) Provide and laying 4mm thick APP modified torch applied water proofing membrane weighing not less than 4.00 Kg per square meter reinforced with non woven polyester matt, weighing not less than 160gm/sqm having softening point not less than 140°C, Longitudinal tensile strength not less than 650 N/5 CM, tear strength of 180N(Min), astatic puncture resistance of 180, keeping a minimum of 10 cm over laps and 15cm end lap.(iv) Apply a coat of blown type bitumen grade 85/25 conforming to IS:702 heated to a working temperature of 180° C and applied @ 1.20 Kg per square meter of the surface area.(v) Provide and laying. 4mm thick APP modified torch applied water proofing membrane weighing not less than 4.00 Kg per square meter reinforced with non woven polyester matt, weighing not less than 160gm/sqm having softening point not less than 140°C, Longitudinal tensile strength not less than 650 N/5 CM, tear strength of 180N(Min), astatic puncture resistance of 180, keeping a minimum of 10 cm over laps and 15cm end lap.(vi) Apply a coat of blown type bitumen grade 85/25 conforming to IS:702 heated to a working temperature of 180° C and applied @ 1.20 Kg per square meter of the surface area.(vii) Finishing surface with solar reflective bituminous aluminum paint @ 100 gm/Sqm complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Taking down 15mm dia bore GI steel tubing and connection including cleaning and making good dismantaled surface complete all as specified. |
| 12 | S&F CPVC pipes, SDR 11, 16mm outer dia conforming to IS-15778 with all brass fittings such as Tee, bends, elbows, unions sockets andetc to receive the fittings and fixed with solvent on walls/ceiling or laying in floors with concealedcomplete all as specified. |
| 13 | Cutting to brick wallschases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing , etc., and making good, cutting not exc 10 cm girth complete all as specified. |
| 14 | Taking down 25mm dia bore GI steel tubing and connection including cleaningand making good dismantaled surface complete all as specified. |
| 15 | S&F CPVC pipes, SDR 11, 25mm outer dia conforming to IS-15778 with all brass fittings such as Tee, bends, elbows, unions sockets andetc to receive the fittings and fixed with solvent on walls/ceiling or laying in floors with concealedcomplete all as specified. |
| 16 | S&Fin repair25 mm dia gate /sluce valave fixed to pipe complete all as specified and directed by Engineer-in-Charge. |
| 17 | Material and labour for repairing of soffits of slabs, chajja, facia and similar works by dismantling of loose/ disintegrated portion of RCC at any height (upto 10M) and in any sitution, including provn of support,formwork and welding of reinforcement and fixing in position and with provision of weld mesh, applying dubbing 1st coat of 20 to 25mm thick in CM 1:3 finished rough and finishing coat of 10mm thick in CM 1:3 finished even and smooth without using extra cementover and including cement slurry @ 3 kg/sqm, finished even and smooth to desired shapeand applyingtwo coats of weather proof exterior emulsion paint over a coat of arylic resistant primer to match with existing surfaces complete all as specified and directed by Engineer-in-Charge.(weld mesh measured and paid sepatrtely)Note:- (i) Unit rate of this item includes the cost of scaffolding, formwork etc. and nothing extra shall be paid on account of variation in height.(ii) For payment purpose, the area of finished plaster in 2nd coat shall be considered. |
| 18 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified. |
| 19 | Material and labour for providing 75mm thick plain cement concrete (1:3:6) type C-2 , using 20mm graded stone aggregate , laid in 1:20 slope in alternate bays as in plinth protection, surface finished even and smooth without using extra cement, complete all as specified. |
| 20 | Material and labour for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) for roof base of water tanks including mixing of admixture fosroc SP 430 of M/S Fosroc chemical @ 250ml per 50kg of cementcomplete all as specified and as directed by Engineer-in-Charge.Note:- WPC will be measured and paid separetly under respective item. |
| 21 | M&L for 25mm thickplain cement concrete 1:2:4 mix,type B1 (using 20 mm graded stone aggregates) as in floor correction layercomplete all as specified and as directed by Engineer-in-Charge. |
| 22 | M&Lfor non Skid ceramic coloured tiles 7 to 8 mm thick (desined pattren) (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick in CM (1:6)for laying floor tiles complete all as specified and as directed by Engineer-in-Charge. |
| 23 | M&L for vertified ceramic tiles9mmthickjoint free double charged(light shade of square/ rectangular) polished,area of each tilesnot exc 0.36 sqmin floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to matchand including 15mm thick screed bed in CM 1:6 laying floor finished complete all as specified and directed by Engineer-in-Charge. |
| 24 | All as per above item no-23 but as in skirting over and including 10 mm thick backing coat with cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 25 | Dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed by Engineer-in-Charge. |
| 26 | S&F glazed ceramic coloured tiles (300mmx 450mmx7-8 mm) in vertical surfacesjointed in neat cement slurry and pointed in white cement. Incl cutting the tiles to the required size whereven required incl mitring the corners etc over 10 mm thick backing coats of cement plaster in CM (1:4) complete all as specified and directed by Engineer-in-Charge. |
| 27 | Dismantling stone slabs and tiles of any descritpion or thickness in floors/skirting laid bedded in any mortar complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material and labour machine cut granite16-20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade laid over 15 mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge . |
| 29 | All as per item No 28 here-in-before but in verticle surface over 10 mm thick backing coat in CM 1:4 complete all as specified. |
| 30 | S&Fgreen marbleof 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills,Jambs, trade, riser, landingetc cooking platformslike in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble andincluding 15mmthick screedin CM 1:4 all as specified and directed by Engineer-in-Charge. |
| 31 | All as per item No 30 here-in-before but in verticle surface over 10 mm thick backing coat in CM 1:4 complete all as specified. |
| 32 | Rounding to edges of stone slabs one edge such as in steps & platform etc |
| 33 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water etc. |
| 34 | Material and labour for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surface of walls, finished fair and even without using extra cement complete all as specified . |
| 35 | M&L fornew plastered surface of wall,applying two coat of oil emulsion distember with preparation ofalkali resistanceprimer paintover two coats of white cement based wall care putty smooth finish etc of approved make & shadecomplete all as specified and as directed by Engineer-in-Charge. |
| 36 | Material and labour for rendering 15mm thick on other than fair faces of brick work or concretewall surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified. |
| 37 | M&L forpreparation of new plastered surface ofwalls,chajjas etcand applying two coats of Dr fixit rain coat Classic and a coat of primer complete all as specified and as directed by Engineer-in-Charge. |
| 38 | M&L for rendering 5 mm thick cement plaster in CM 1:3on ceiling or concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified. |
| 39 | M&L for preparation of new plastered surface of ceiling andapplyingthree coat of white wash complete all as specified and as directed by Engineer-in-Charge. |
| 40 | M&L for Preparation of old decorated surfaces of walls,Pillars, cornices etc by brooming down with steel wire brush, scraping down smoke shoot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on ceilingsetc complete all as specified and as directed by Engineer-in-Charge. |
| 41 | Material and labour forcomplete removal of existing treatment ofolddecoratedwall surface applying two coat of oil emulsion distember over alkali resistanceprimer paintover two coats of white cement based wall care putty smooth finish etc of approved make & shadecomplete all as specified and as directed by Engineer-in-Charge. |
| 42 | Complete removal of existing treatment of external wall surfaces including removing fungus ,algae dirt, oil, grease and loose particles by wire brush,cleaning, washing with water jet machine,and applying with Dr fixitcrack filler by proper grooving, andapply two coats of Dr fixit (one coat rain coat water proofing+one coat rain coat classic top coat) of approved shade by Engineer-in-chargeover a coat of primer .The drying time of two coats will be6 to 8 hrs ,including all necessary scoffolding etccomplete all as specified. |
| 43 | S&Fin repairStainless steel curtain rods 25mm bore SS -304 withornamental brackets, stops, complete all as specified and directed by Engineer-in-Charge. |
| 44 | S&F in repairstainles steel sink with drainage board , 1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers and wastes including bedding in cement morter to dwarf wall or including fixing CI cantilever bracket, connecting union to pipeetc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm etc complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F in repairsstain less steel Wall MountedKitchen Utensils Dish Rack Stand With Plate & Cutlery Stand of Size(10 x31x48 Inches) Dish Stand/Holderthe sample approved and as directed by Engineer-in-Charge. |
| 46 | Dismantling plain or corrugated steel sheeting, any gauge, and thickness including Nainital pattern and roof covering, complete all as specified. |
| 47 | S&F for Pre- Painted galvalume aluminiumzinc coating GI basedcorrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws,including taking down complete all as specified and directed by Engineer-in-Charge. |
| 48 | Cutting chases,for concealed/fixing galvalume sheet etc., and making good, cutting notexc 10 cm girth pinning in. making good to facing of stone concrete block or slab wallswhere required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels,chajjas etc.;complete all as specified. |
| 49 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 50 | S&Fframed,trussesfor sunshade /roof projection chajjas, purlins, rafter,rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W(Gde-E-250) including taking down all as specified and directed by Engineer-in-Charge |
| 51 | S&F framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified. |
| 52 | M&L for Preparation of newsteel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of anti corrosive paint (Epoxy) a coat epoxy primercomplete all as specified and directed by Engineer-in-Charge. |
| 53 | Taking down and refixing old existing iron grills of areaexc 1.50 sqm but not 4.0sqmwith the preparation of steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of anticorrosive paint (Epoxy paint) complete all as specified and directed by Engineer-in-Charge. Note :Anticorrosive paint on steel surface mesuared and paid to separately withrespective item. |
| 54 | M & L for Preparation of old painted steel surfaces of any description having width/girth exceeding 10cm and apply two coat of anticorrosive paint complete all as specified and as directed by Engineer-in-Charge. |
| 55 | Taking downchowkats of wooden/steel/aluminium/doors ,windows,ventilations complete with frames and shutters (without taking off the shutters and guard bars) of area not exc 1.5 sqmcomplete all as specified and directed by Engineer-in-Charge. |
| 56 | Taking downchowkatsof wooden/steel/aluminium/doors ,windows ,complete with frames and shutters (without taking off the shutters grills and guard bars) of area exc 1.5 sqm and not exc 4.00 sqmcomplete all as specified and directed by Engineer-in-Charge. |
| 57 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50mm x 100mm of requiredsize and approved coloured comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximumoxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawaltrength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia andlength complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid forseparately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. complete all as specified and as directed by Engineer-in-Charge . |
| 58 | S&FFactory made30 mm thick single extruded WPC (Wood Polymer Composite) both side laminated/ decorative of solid shuttercomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 59 | S&F Factory made single extruded WPC (Wood Polymer Composite)of required coloured solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximumoxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawaltrength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia andlength complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid forseparately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. complete all as specified and as directed by Engineer-in-Charge by engineer -in - charge. |
| 60 | S&F Providing 30mm thickfactory made wire mesh solid WPC door shutter both side decorative /laminated structure (as approved by Engineer-in-charge) consisting of Density 500 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19x6mm size steel screws etc. Complete as per direction of Engineer-in -charge, manufacturer\"s specification & drawings. |
| 61 | S&F Solid WPC frame (Single Rebated) of approved colour of size 50mm x 75mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheetmetal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be waterproof, termite proof, elegant and should have excellent screws holdingstrength to fix hinges and hold doors properly for a long life) complete all as specified |
| 62 | S&FFactory Made 24 mm thick 100% Solid WPC ( Wood polymer Composite ) LaminatedFlush door Shutter of required size and colour(one side decorativeother side plain )comprising of virgin PVCand Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) having good screw holding capacity Minimum Compissive of 50 N/mm2,of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant complete all as specified. |
| 63 | Cutting holes in brick walls exc. half brick but not exc. one brick in cement mortar or cement lime mortar and stone/concrete wallsfor inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required(depth of embedded portion of hold fastsor lugs measured from the face of the jamb in to the wall) complete all as specified. |
| 64 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work sliding arrament framefor doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/eoprene gasketetc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 65 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors,slidingwindows & ventilators including providing and fixing hinges/ pivots and making provision for fixing ofittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/, and in cludingas suitable hinzes stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 66 | S&F aluminiumpowder coated push button locking arrengements as per required sizes of aluminium sliding windows ,ventilation etc complete all as specified |
| 67 | S&F 4.80mm thickness Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each panecomplete all as specified and as directed by Engineer-in-Charge . |
| 68 | S&F in repair 4.00mm thicknessfrosterd Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each panecomplete all as specified and as directed by Engineer-in-Charge . |
| 69 | S &F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width ofaperture1.40mm and fixed with stainless steel wire stapleswith in aluminium windows, doors etc, complete all as specified and as directed by Engineer-in-Charge . |
| 70 | S&F 300 mm long stain less steelsliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed Complete all as specifiedand as directed by Engineer-in-Charge. |
| 71 | S & F 100 mm sizestain less steel Butt hinges,with mild steel hinge pin, bright polished and fixed, typeB-11 Complete all as specifiedand as directed by Engineer-in-Charge. |
| 72 | S&F 150 mm long stain less steelhandles, Complete all as specifiedand as directed by Engineer-in-Charge by Engineer-in-Charge. |
| 73 | S&F Stain less steel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed 200mm long. |
| 74 | S&F 150mm Floor door stopper of bassbody and tongue with hard drawn steel spring fixed in floor complete all as specified and directed by Engineer-in-Charge. |
| 75 | S&F PVC Pre - laminated factory made kitchen cabinet &cub board shutter with frameof 18 mm thick approved colour /shed quality and make made from PVC one side pre laminated sheet .The exposed edges shall be sealed with PVC edges beading of same shed and colour, the shuttershall be fire retradent having necessary screws & sliding chennals forholding capacity,Shutter shall be fixed to frame using approved hinges with necessary stain less steel screws, stainless steel handles not less than200mm longandincluding taking down kitchen cabinet/ cub bord shutters with frameof any description etccomplete all as specified andas directed by Engineer-in-Charge. |
| 76 | S&F 75 mm stainless steel butt hinges complete all as specified and as directed by Engineer-in-Charge |
| 77 | S&F 150 mm long Extruded brass handles, fabricated type polishedComplete all as specifiedand as directed by Engineer-in-Charge. |
| 78 | S&F Magnetic cather for cupboard fixed with fixing arrangement complete all as specified . |
| 79 | S&F in repair 20mm dia Stain less steel rod with bracketsfixing in cupboard complete all as specified. |
| 80 | Dismantiling and removing sunken slab filling of brick bats/cinder/light weight concrete including plastering on sunken floor/sides of floor slab/tiles of toilets in all the floors including all the water and sanitary fixtures and removing all rubbish/debris outside MoD land as per instruction complete all as specifiedand directed by Engineer-in-Charge. |
| 81 | Material and labour for the suken floor RCC slab including sides to the full extent of sunken portion in upper floor shall be prepared and plastered with 15 mm thick cement plaster in CM 1:3 with water proofing compound as per manufacturer\"sinstructions and finished even and smooth without using extra cement. When the plaster is cured and dried up, apply a uniform coat of blown grade bitumen 85/25 @ 1.2 kg/Sqm confirming to IS 702 over a coat of primer @ 0.70 Kg.Sqm over plastered surface complete all as specified and as directed by Engineer-in-Charge.Note :- Integral water proofing compound shall be measured and paid separately as \"Supply only\". |
| 82 | Water proofing treatment to Sunken floor slabe complete as specified bellow and as directed by Engineer-in-Charge.(a) Provide and lay 4mm thick APP modified torch applied prefabricated five layer water proofing membrane weight not less than 3.60 Kg/Sqm.(b) Apply a uniform coat of blown grade bitumen 85/25 @ 1.2 Kg/Sqm confirming to IS 702 of the surface area complete all as specified. |
| 83 | Material and labour for PCC lean concrete 1:5:10 type E2 laid in layers of not more than 100 mm thick tamping etc complete all as specified and directed by Engineer-in-Charge. |
| 84 | Material and labour for 40mm thick PCC 1:2:4 type B0 (12.5 mm graded )stone aggregate as padding concreteetc over lean concrete complete all as specified. |
| 85 | S&F in repairVitreous china wash down water closet (Padestal pattern) pan white including bolts and flush pipe, pedestal pan and trap including connections to drain (or outgoing pipe) and flushing pipe etc including seat cover closed type complete all as specified. |
| 86 | S&F in repair10 litre PVC valveless, duel function syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified. |
| 87 | S&F in repairVitreous china white flat back of size 450x300mm wash basins, vitreous china (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe including 32 mm dia CP waste fitting complete all as specified and directed by Engineer-in-Charge. |
| 88 | S&F in repairPVC connection low density polythene pipe 15mm dia, 450mm long, heavy duty with PTMT nuts complete all as specified. |
| 89 | S&F in repairs Bib taps, fancy type, chromium plated Quarter turnwith crutchsc-rewed down, screwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 90 | S&F in repair Pillar taps, fancy type, chromium plated, Quarter turns crewed down, high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 15 mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 91 | S&Fin repair brass chromium plated tubular towel rail 20mm dia \"D\" type 60 cm long between flanges complete all as specified and directed by Engineer-in-Charge. |
| 92 | S&F in repairs15mm borebrass CP Mixer Quarter turns for mixing hot and cold water screwed iron /PVC pipewith long screwed shanks and fly-nuts, complete all as specified and as directed by Engineer-in-Charge. |
| 93 | S&Fin repair15mmangle cock/stop cock cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 94 | S&F in repairstain less steel soap dishsize of approximate160x160x90mm fixed to plugs with chromium platedwith brass screws complete all as specified and directed by Engineer-in-Charge. |
| 95 | S&F in repairs health faucet ABC) mild steel chromium plated suitable for 15mmdia pipie with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified. |
| 96 | S&F in repairs 600 X 450mm bevelled edge mirror, 5mm thick selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs to wall with chromium plated brass screws and cup washers complete all as specified and as directed by Engineer-in-Charge. |
| 97 | S&F in repairs brass chromium plated shower rose with or without swivel joints 75mm size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-Charge. |
| 98 | S&FPVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4)including removing old trap complete all as specified and as directed by Engineer-in-Charge. |
| 99 | S&FPVC (SWR) gully trap , 125/110 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4)including removing old trap complete all as specified and as directed by Engineer-in-Charge. |
| 100 | S&F in repair 100mm stain less steel gratingscomplete all as specified. |
| 101 | S&F 110mm borefor PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls ,etc, including taking down existing pipe complete all as specified. |
| 102 | S&F in repairPVC (SWR) bends of 110mm bore with access door complete all as specified . |
| 103 | S&F in repairPVC (SWR) branch piece double Y equal or unequalof 110mm bore in radius complete all as specified . |
| 104 | S&F for PVC (SWR)75mmpipes, single socketed, in any length with rubber ring joints, laid in in walls , floors ,etc in cluding taking downexisting pipe complete all as specified. |
| 105 | S&F in repairPVC (SWR) bends of 75mm bore with access doorcomplete all as specified . |
| 106 | S&F in repairPVC (SWR) branch piece double Y equal or unequalof 75 mm bore in radius complete all as specified . |
| 107 | Excavation in trenches, n exc 1.50 mtr wide and n exc 1.50 mtr in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n exc 1.50 mtr in depth and getting out inhard densesoil complete all as specified. |
| 108 | Returning filling in hard dense soil,including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified. |
| 109 | Removing excavated material / soil exc 250 m but n. exc 500 m and depositing whereasdirected by Engineer-in-Charge. |
| 110 | Demolition of brick work/stone masonry built in cement mortar including all quoins arches, pillars all as directed by Engineer-in-Charge. |
| 111 | M&L for brickwork with subclass \"B\" bricks, straight or curved on plan exc 6m mean radius, built in cm 1:6complete all as specified. |
| 112 | Material and labour rendering 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces in septic tank and man hole external & internalfinishes the surfaces even and smooth without extra cement coat including using water proofing compound 2% by weight of cement etc complete all as specified & directed by Engineer-in-Charge. (Note :-Supply only water proofing compound will be measured and paid separately) |
| 113 | Material and labour for reinforced concrete pipes class NP-2 ,150 mm dia laid and jointed coplete with collars and including demolition and breaking up Existing SGSW/RCC/SWRpipes concrete bed including packing under and haunchingjointed in cement mortar and taking out of trenches if requiredetc,complete all as specifed and directed by Engineer-in-Charge. |
| 114 | Material and labour concrete bed to 150 mm dia pipes of cement mortar 1:3:6 type C-2 including packing under and haunching against the side of pipes after they are laid and tested complete all as specifed and directed by Engineer-in-Charge. |
| 115 | Providing and fixing pre-castreinforcedcement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs ,roof,floor slab, etcincluding framed work for man holes etc including weathering ,slightly rounded or chamfered angle and throating as directed by Engineer-in-Charge including necessary form work complete all as specifed and directed by Engineer-in-Charge. |
| 116 | Material and labour for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slabs, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to TMT bars complete all as specified. |
| 117 | Material and labourfor tmt bars 6- 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 118 | Taking down carefully unserviceable aluminium/copperpoint wiring (light, fan, socket or power)including unserviceablelight fittings, switch board complete,switch sockets, ceiling roses, pendants, regulators, sockets, etcandremoving materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge. |
| 119 | M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and includingproviding PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed by Engineer-in-Charge.(a) One light point or one fan pointor bell point controlled by one switch |
| 120 | All as per item No 2 here-in-befor One 3 pin socket outlet, 5 Amp independent |
| 121 | All as per item No 2 here-in-befor One 3 pin socket outlet, 5 Amp on the same board with other switches |
| 122 | All as per item No.2 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed by Engineer-in-Charge. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately). |
| 123 | S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 124 | S & F socket out let, 2 in 1, 3 pin,5 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 125 | S & F Switch socket combination, 2 in 1,5 Amps,flush type, 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 126 | S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-Charge. |
| 127 | S & F Ceiling rose, 3 way PVC insulated bodycomplete all as specified and directed by Engineer-in-Charge. |
| 128 | S&F Buzzer, Ding Dong AC, 230 Volts single pole. |
| 129 | S&Felectronics typefan regulator ,120 W complete all as specified and as directed by Engineer-in-Charge. |
| 130 | Supply and fixing Batten 1x18W(single side supply)for LED TUBE LIGHT pre -coated CRCAA sheett, end caps made up with engineering plasticall as specified and directed by Engineer-in-Charge. |
| 131 | Supply and fixing ROD 1x18W (single side supply)for LED TUBE LIGHT T8 tube with polycarbonate body all as specified and directed by Engineer-in-Charge. |
| 132 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 133 | S/F switch bell push, flush type 5 Amp. |
| 134 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) |
| 135 | Supply and fixing LED Building light/street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 136 | Supply & fixexhaust fans steel body AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed by Engineer-in-Charge.Note:- Cost of making hole for Exhaust fan of required size at site is deemed to be included in quoted rates.SKU Code-70003 Bajaj/Havells |
| 137 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20DP all as specified and directed by Engineer-in-Charge |
| 138 | M&L for earthing complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized iron strip 25 X 4 mmby means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition. |
| 139 | S&F MCB DB TPN 4 ways double door with 440 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed by Engineer-in-Charge Make:Havells QVE series or equivlent legerend/standard/indoasian |
| 140 | S&F MCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed by Engineer-in-Charge Make:Havells QVE series or equivlent legerend/standard/indoasian |
| 141 | S&F in repairs MCB SP 5 To 32 AMP,single pole 240 Volts 10KA \"\"C\"\"&\"\"B\"\" curve , as per site requirment,Complete all as specified and directed by Engineer-in-Charge. |
| 142 | S&F in repairs MCB SPN 32 AMP,240 Volts 10KA \"C\" curve , Complete all as specified and directed by Engineer-in-Charge. |
| 143 | Supply and fixing MCB TPN/FP40 To 100 AMP 415V 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning. |
| 144 | Taking down of Old MCB DB / control box any type any size including MCBs and separating the serviceable MCB DBs and MCBs for reuse at site |
| 145 | M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wiresize2x4.0 sq. mm +1 x4 sq. mm earth wire earth wireof FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:-Two run of 4 sqmm wire and Onerun of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 146 | Taking down electric meter of any type and any make single/three phase by dismantling of all electrical connection checked the meter, and Refixed same Nos of meter on wooden board in metal box of suitable size in same Nos of quarter after repair works completed. |
| 147 | Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc. complete all as specified and directed by Engineer-in-Charge. |
| 148 | S & F of PVC connections 15mm size with PTMT nuts of length 300mm complete all as specified and directed by Engineer-in-Charge. |
| 149 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings with outer diameter of 20mmin trenches complete all as specified. |
| 150 | S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail