|
| 1 | B/R Portion |
| 2 | Bringing approved earth (soft/loose soil ) from out side of defence land (any distance ) and depositedfor embankment / filling of craters / low lying area and includingspreadingin layers n. exc. 30 cm thick,levelled & including ramming withmechanical roller including wateringcomplete all as specified.NOTE:-(i) Earth shall be free from foreign materials i.e grass, roots etc.(ii) To arrive finished quantity for payment purpose consolidation thickness shall be measured.(iii) The specified proctor density under optimum moisture condition shall be obtained and 5% deduction for bulkage shall be made.(iv) The consolidation shall be done by heavy mechanical machinery and number of passes shall be determine at site as per direction of Engineer-In-Charge.(v) Cost of earth and removal to any lead shall be deemed to be included in the quoted rates. |
| 3 | PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in filling & mass concrete, sub base, complete all as specified. |
| 4 | Reinforced cement concrete, type B-1,(1:2:4), (nominal mix) using 20 mm graded stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in kitchen shelves and the like complete all as specified. |
| 5 | Grouting 25mm thick under stanchion bases or grillages etc including any temporary shuttering to edges with cement mortar 1:2 completed. |
| 6 | Cutting holes into or through RCC/brick walls built in cement mortar exceeding half brick thick but not exc one brick thickfor inserting angle/tee/pipe/ hold fast or similar purposes etc. and making good in cement mortar 1:3 or cement concrete 1:2:4, Type B-1 as required complete all as specified. |
| 7 | Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified. |
| 8 | Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with fair finished surfaces of concrete, complete all as specified. |
| 9 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete, all as specified. |
| 10 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and wood grain colour PVC sheet for top rail, lock rail and bottom rail, panelling of wood grain colour PVC sheet to be fitted in the MS frame welded / sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part II, complete all all as specified. |
| 11 | Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, thickness 30 mm,etc complete all all as specified. |
| 12 | Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforcedwith mild steel square tube, suppling & fixing in opening, complete all as specified. |
| 13 | 2nd Class hardwoodof size 105 mm x 60 mm made wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints supplied and fixedcomplete all as specified |
| 14 | Stainless steel 100mm long butt hinges with stainless steel screws, ISI marked complete all as specified. |
| 15 | Aluminium anodised barrel tower bolt of extruded section 150mm long, ISI marked, complete all as specified. |
| 16 | Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extrudedsections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 250 mm long,complete all as specified. |
| 17 | Aluminium handle, 125 mm long, curve shape with stainless steel screws, complete all as specified. |
| 18 | Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tacks or steel wire staples all as specified. |
| 19 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 20 | Mild steel bands, straps, supports, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; chains; hand made sliding bolts; clamps; hold fasts; wall ties;plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles confirming to Fe-290-Gde E-165, complete all as specified. |
| 21 | Roof sheets stays, window guard bars, plainlet in and fixed independently in wooden frame L or T section support for shelves etc, and similar articles conforming to Fe-290 Gde E-165 including dismantling existing iron complete all as specified. |
| 22 | Powder coated aluminium frame for doors, windows, ventilators, fixed glazing with one or more rebates including joining cleat for fixing, fixed to opening with suitable size steel screws and rawl plugs etc., (aluminium section not less than 2 mm) complete all as specified. |
| 23 | Powder coated aluminium window and ventilator shutters fixed type without sash bar including anodised alumnium glazing snap beadingrubber neoprene packing including joining cleats &screws etc as per manufacturers instructions, complete all as specified.NOTES:(a) Each shutter shall have2 Nos. 125 mm long almn handles and 02 No. 75 mm size stainless steel/almn butt hinges & one no. almn hook & eye.(b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ.(c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron. |
| 24 | Figured glass, 4 mm thick, ordinary quality duly sticked with solar control reflective type film, having thickness not less than 25 micron and fixed air tight with neoprene packing & almn glazing clips, for aluminium sections, complete all as specified. |
| 25 | 75 mm thick, cement concrete type C-2, 1:3:6 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified. |
| 26 | Granite jet black shade, 18-20 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished,bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified. |
| 27 | Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified. |
| 28 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., and brushing a coat of cement slurry with 3 kg of cement per Sq.m, complete all as specified. |
| 29 | Glazed ceramic coloured tiles 7-8 mm thick,area of each tile exc. 0.13 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified |
| 30 | Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified. |
| 31 | Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.18 Sq.m but n. exc. 0.38 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified |
| 32 | Factory made PCC colured chequered tiles, ISI(IS:13801) marked, 22-25 mm thick, of size 300 mm x 300 mm, in floors, over & including 15 mm thick cement mortar (1:4) screed, set and jointed with grey cement slurry complete, all as specified. |
| 33 | Rendering 5 mm thickon fair faces of concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), complete all as specified. |
| 34 | Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6),complete all as specified. |
| 35 | Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified. |
| 36 | Supply only water proofing compound, ISI marked, complete all as specified. |
| 37 | Setting coat 3mm thick of cement plaster 1:2 trowelled to even and smooth finish complete all as specifed. |
| 38 | Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in 3mm thick& smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemperover and including a coat of acrylic emulsion primer. |
| 39 | Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in 3mm thick& smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemperover and including a coat of acrylic emulsion primer. |
| 40 | Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats& smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed). (b) Two coats of exterior acrylic emulsion over and including a coat ofwater based exterior primer. |
| 41 | Complete removal of existing treatment of any description, including prepration of wall surfaces of any description and applying Two coats of exterior acrylic emulsion over and including a coat ofwater based exterior primer complete all as specified. |
| 42 | Two coats of white wash on old ceiling surfaces, including preparation of surfaces, complete all as specified. |
| 43 | Three coats of white washing on new undecorated ceiling surfaces, including preparation of surfaces, complete all as specified. |
| 44 | Preparation of old painted wood and wood basedsurfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified. |
| 45 | Two coatsof synthetic enamel paint over & including a coat of pink primer overwood and wood (new) basedsurfaces of any description not other wise described over 10cm width or girth including preparation of surfaces complete all as specified. |
| 46 | Two coats of synthetic enamel paint over & including a coat of red oxide primer oversteel & iron (new) surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified. |
| 47 | Polypropylene random copolymer (16 mm dia,3 layer ) concealed pipes SDR 7.4 (PN16) UV stablized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random fitting fixed complete to wall, ceiling or in floor etc. |
| 48 | Unplasticised PVC pipes of pressure rating 10kgf/cm2 fixed complete to wall, ceiling or in floor etc complete all as specified of following size: - |
| 49 | 20 mm dia |
| 50 | 25 mm dia |
| 51 | Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, including taking down existing tube complete all as specified of size: - |
| 52 | 15 mm bore |
| 53 | 20 mm bore |
| 54 | 25 mm bore |
| 55 | Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPLACEMENT,complete. MAKE: Prayag Cat No.9318-N or equivalent make mentioned in Appendix \"B\". |
| 56 | Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPLACEMENT,complete. MAKE: Prayag Cat No.6509 or equivalent make mentioned in Appendix \"B\" |
| 57 | Pillar tap, cast copper alloychromium plated fancy type, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPLACEMENT,complete. MAKE: Prayag Cat No.6502 or equivalent make mentioned in Appendix \"B\" |
| 58 | Gun metal ball valves, high pressure, with metal rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, IN REPAIRS, suitable for 20 mm bore GI pipe, complete all as specified.complete all as specified. |
| 59 | Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, ISI marked, white, with integral foot rests (excluding flushing cistern and flush pipe), 110x125 size uPVC \"P\" trap & necessary joints, lime concrete, IN REPAIRS, complete all as specified. |
| 60 | Vitreous China wash down water closet pan (pedestal pattern), white ISI marked, with & including stainless steel body Jet spray (L-bend) with 1.50 metre long braded tube tube, soft close ISI marked PVC seat & cover, IN REPAIR, complete all as specified |
| 61 | Vitreous China wash basin, white, flat back, size 550 x 400 mm, ISI marked,including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe, IN REPLACEMENT, complete all as specified. complete all as specified. |
| 62 | PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories,IN REPLACEMENT, complete. |
| 63 | Looking mirror 600 x 450 mm, selected quality glass 5.5 mm thick, mounted on PVC ply not less than 6 mm thick, and provision of PVC frame alround fixed with chromium plated brass screws and rawl plugs, complete |
| 64 | Health faust with 1 metre SS tube & hook complete. MAKE: PRAYAG Cat No. BEA-97 or equivalent make mentioned in Appendix \"B\". |
| 65 | Brass chromium plated towel rail600 mm long, fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS,complete.MAKE: PRAYAG Cat No. CPA-10 or equivalent make mentioned in Appndix \"B\". |
| 66 | PVC connections 15 mm size of length 450 mm with PTMT nuts,complete all as specified. |
| 67 | uPVC pipes,type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors / fixed to wallas SWR pipes, IN REPLACEMENT, complete all as specified of size: - |
| 68 | 75 mm external dia pipe |
| 69 | 110 mm external dia pipe |
| 70 | uPVC/PVC bend any radius, complete all as specified. suitable for uPVC soil waste discharge pipes,of size: |
| 71 | 75 mm external dia pipe |
| 72 | 110 mm external dia pipe |
| 73 | uPVC/PVC junction single (Single T) equal or unequal 75mm external dia complete |
| 74 | uPVC/PVC junction single (Single T) equal or unequal 110mm external dia complete |
| 75 | uPVC/PVC vent cowl 75-110 mm external dia, complete all as specified. |
| 76 | 110mm dia uPVC / PVC \"P\" trap complete all as specified. |
| 77 | 75mm dia uPVC / PVCfloor trapincluding jointing with solvent and embedding in cement concrete type B-1 (1:2:4) complete all as specified. |
| 78 | E/M Portion |
| 79 | Point wiring with multi-stranded copper conductor, single core, FRLSH PVCinsulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ socketscomprising the following: - |
| 80 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 81 | One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified. |
| 82 | One socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable &1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 83 | One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 84 | NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule \"A\". (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4). |
| 85 | Switch piano flush button single pole one way, 6 Amp complete all as specified. |
| 86 | Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified. |
| 87 | Switch Socket combo of capacity 15/16 Amp, complete all as specified and directed. |
| 88 | Fan regulator (electronic) suitable for 48”/56” sweep fan, step sockettype, single phase,complete all as specified. |
| 89 | Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified. |
| 90 | Surface mounted environment friendly LED 20 Wbatten with polycarbonate housing & integrated electronic driver, lumen output should not be less than 90 lumens per watt including making connections up with three core flexible copper conductor cable, IN REPLACEMENT, complete all as specified. |
| 91 | Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, IN REPLACEMENT,complete all as specified comprising the following: |
| 92 | SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type. |
| 93 | TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type |
| 94 | MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, \"C\" curve type of rating 63 Amp,complete all as specified. |
| 95 | MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, \"C\" curve type of rating6 to 32 Amp,complete all as specified. |
| 96 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified. |
| 97 | Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, with and including rigid non metallic PVC medium duty concealed conduit not less than 25mm dia complete all as specified for the following: - NOTES: (i)For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as \"1 RUNNING METRE\" |
| 98 | 2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable |
| 99 | 2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable |
| 100 | Ceiling fan complete with blades, down rods, stepped type electronic regulator and accessories, 230 volt, 1200mm sweep with service value 6.00 BEE with brushless direct current motor (BLDC) including PVC insulated and overall sheathed flexible 3 core 1.5 Sq.mm copper conductor cable complete all as specified |
| 101 | Hi wall split units indoor / outdoor complete with cordless remote control unit invertar type and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating cooling & heating function and EER 3.2 of capacity 1.5 Tonand mounting accessories kit with stand complete all as specified. |
| 102 | Water cooler electric driven (single phase) having approx storage capacity of 80 ltr and nominal cooling capacity of 40 ltr per hour complete all as directed. |
| 103 | Refrigerator , electric driven (single phase ) capacity more than 300 ltrs upto 365 ltrs BEE5 star rated complete all as directed. |
| 104 | Desert cooler electric driven (single phase), having nominal air flow capacity of 5000 cum per hour (or nearest size ) plastic /pvc body complete all as directed. |
| 105 | 25 Litre , 4-Stage RO Purification forEffective removal of impurities such as dissolved salts, chemicals, and microbes to ensure safe, great-tasting drinking water with Stainless Steel Tank ofrust-resistant tank keeps stored water safe and free from contamination, making it ideal for use all as specified and as directed by Engg in charge. |
| 106 | Earthing to panel with galvanised steel plate electrode 600 mm x 600 mm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal groung level) with top edge of earth lead wire 4.0 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES Schedule pt-I 2009, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mmbore GI light grade pipe for watering and including funnel, wire mesh, RCC cover, reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, using round bar, PGI funnel with wire mess & frame, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I.IN REPLACEMENT, complete all as specified. Note:- (i)PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(iii) Earth resstance shall be less than 3 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt. |
| 107 | Demolition and Dismantling Work |
| 108 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified. |
| 109 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sq.m but not exceeding 4.00 Sq.m each and removing from site all as specified. |
| 110 | Taking down cement plaster of any description on brick walls or concrete surfaces etcincluding raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 111 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 112 | Demolition brickwork or stone / boulder masonrybuilt in cement mortar including all quoins, arches, pillars etc complete all as specified. |
| 113 | Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified |
| 114 | Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided all as specified. |
| 115 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. |
| 116 | Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. |
| 117 | Note : Amount ofcredit for retrieved materials is mentionedin Sch of credit of tender documents in pdf form which will be deducted while acceptance of tender offline. |