| Sl. No. | Item Description |
| 1 | Dismanting asbests cement ( corrugated, semi-currugated etc.) sheets in roof covering complete all as specified and directed. |
| 2 | Dismanting single layer mangalore pattern or similar tiles in roofing complete all as specified and directed. |
| 3 | S & F prepainted galvalume aluminium zink coating GI based corrugated steel sheeting 0.5mm thick of any colour having tensile stength of 550 MPAasin roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 4 | S&F pre painted gal valume aluminium zink coating GI based plain steel sheeting 0.5mm thick of any colour haing tensile strenghth of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 5 | Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed. |
| 6 | Dismantlingframed wooden purlin/Rafterwork of any descriptionsectional area n exc 40 Sqcm not other wise provided for complete all as specified and directed. |
| 7 | S & F roof trusses (framed) trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc confirming to grade Fe-410 W E250 quality A complete all as specified and directed. |
| 8 | Fixing only roof trusses (framed) trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc confirming to grade Fe-410 W E250 quality A complete all as specified and directed. |
| 9 | M & L for providing cement concrete type B-1 1:2:4 (20mm graded crushed stone aggregate) as in roof curves or muds, stops, rounded or chamfered on edges complete all as specified and as directed. |
| 10 | M&L for preparation of old steel surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 11 | M&L for preparatioin of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of Red oxide primer complete all as specified and directed. |
| 12 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etccomplete all as specified and directed. |
| 13 | M & L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built cement mortar 1:6 complete all as specified and directed. |
| 14 | Taking down plastering on brick walls etc including racking out joints, hacking for key, scrabing down with water etc.complete all as specified and directed. |
| 15 | M & L for 15 mm thick (inner 10mm layer 1:6 and outer 5mm layer 1:4) rendering in Cement Mortar on fair faces of Brick works or Concrete surfaces and finishing even and fair without using extra cement and using water proofing compound @ 3% of weight of cement fot top 5mm layer complete all as specified and directed incl scaffolding if necessary and including Taking down plastering on brick walls etc including racking out joints, hacking for key, scrabing down with water etc.complete all as specified and directed.Note: WPC will be measured and paid separately under the relevant item. |
| 16 | M & L for 15 mm thick rendering in Cement Mortar 1:6 on fair faces of Brick works or Concrete surfaces and finishing even and fair without using extra cement. complete all as specified and directed. |
| 17 | M&L for preparation of new wall surfaces of wall and applying two coats of exterior emultion weather proof paint over a coat of cement primer complete all as specified and directed. Note: Weather proof paint shall be done by Roller only. |
| 18 | M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer and complete all as specified and directed. |
| 19 | M&L Complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of primer and a coat of putty complete all as specified and directed. |
| 20 | Material and labour for complete removal of existing treatment, preparation of surfaces and applying two coats of exterior emultion weather proof paint over a coat of primer complete all as specified and as directed.Note: weather proof paint shall be done by Roller only. |
| 21 | Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets complete all as specified and directed. |
| 22 | M&L for providing false ceiling with anodised aluminium snap grid frame work for false ceiling with size of grid 605 x 605mm with aluminium main tee, cross tee size 25x25x1.6 mmand aluminium wall angle size 25x25x1.8 mmfixed to wall hanging from soffits\trusses\bracking using adjustable supportinghanger compressing of GI wire 4mm thick with locking clip.complete all as sepcified and directed |
| 23 | M&L for Providing and fixing Non asbestos designer E-Board 4mm thick in ceiling fixed to snap gridas per manufacturers instructions complete all as sepcified and directed |
| 24 | Taking down chowkat with frame (without taking off shutter from the frame) n exc 1.50 Sqm each complete all as specified & directed. |
| 25 | Taking down chowkat with frame (without taking off shutter from the frame) exc 1.50 Sqm each complete all as specified & directed. |
| 26 | S&F of factory made solid PVC moulded shutter with 28 to 30mm thick(stiles)with 2,4 or 6 raised panel design with 2mm thick moulded PVCprelam sheet on the front face and 2mm thick plain colour PVC sheet on back face with particle board core complete all as specified and directed. |
| 27 | S&F of solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing complete all as specified and directed. |
| 28 | S&F of Butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed 100mm type C-21 complete all as specified and directed. |
| 29 | S&F of aluminium anodised barrel tower bolts of extruded section and fixed 150mm complete all as specified and directed. |
| 30 | M&L for plain cement concrete type C-1 1:3:6 (using 20mm graded crushed stone aggregate) for setting hold fasts, steel windows complete all as specified and directed. |
| 31 | M & L for 2nd classhard wood Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 32 | S&F for 35mm thick factory made plain framed paneled shutter of 2nd class HW (any Number of panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm th venered particle board with veneering on both face kiln seasoned & chemically treated complete all as specified & directed. |
| 33 | S & F 35mm thick 2nd class hard wood glazed skeleton door shutters open rebated and prepared to receive glass, gauze, etc (without sah bars) and divided into square with plain, rounded, chamfered, mitred complete all as specified & directed. |
| 34 | Supply & Fixing Windows/Ventilators fabricated from roll framed sections made of galvanized steel colour coated/ powder coated (Base steel as per IS 513 “D” quality galvanized as per IS 277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.58mm.Paint Specifications:Coated sections should be with Primer coat of Epoxy Primer of 5-7 microns thick, finish painted with Polyester paint of 12-16 microns thick or Powder Coated with pure Polyester up to 50-60 microns thick.Dimensions of Sections:Sections for Frame should be of 72mm x 55mm, Section for Mullion should be of 72mm x 50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixed Glass Bead should be of 12mm x 12mm, and Section for Fly Mesh should be of 40mm x 20mm.Fixing Details: Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter.Accessories:Each Glazed Shutter and Mesh shutter should be provided with SS Pivot Hinges – 1 set, Seccolor Handle & Seccolor Stay.Window Frame should be fixed to brick/ concrete masonry by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frameGlass: Glass shutter & Fixed Glass portions should be provided with a glass of 4MM Plain Float Glass.Mesh: Mesh Shutter should be provided with a Stainless SteelFly mesh of 304 grades. Grill:Windows should be provided with Grill made of 10mm sq. MS Bars welded to at 150mm center-to-center, 5mm x 10mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws. complete all as specified and directed.Make: Elixir/ NCL |
| 35 | S & F 125mm butt hinges medium weight cold rolled mild steel complete all as specified & directed. |
| 36 | S & F Aluminium handle 150mm fabricated type complete all as specified & directed. |
| 37 | S & FAluminium anodised barrel tower bolts 200mmof extrded section complete all as specified & directed. |
| 38 | S & F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 39 | S&F 300 mm long helical door springs including roller plate complete all as specified & directed. |
| 40 | S& F 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed. |
| 41 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and avg width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed. |
| 42 | M & L for preparation of new wooden surface and applying two coat of synthetic enamel paint over one coat of pink primer over 10cm width or girth complete all as specified and directed. |
| 43 | Demolition of cement concrete(unreinforced) in ground floors and pavingnexc 15 cm thickness (below and above ground level) complete all as specified & directed. |
| 44 | M & Lfor 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stoneaggregate) as in plinth protection finished even and smooth without using extra cement. complete all as specified and directed. |
| 45 | S&F 25mm Stainless steel curtain rods incl required nos ofbrackets complete all as sepcified and directed |
| 46 | Demolition of stone slabs of any description or thickness in floors, aprons, etc laid, bedded and pointed in any mortar as sepcified and directed |
| 47 | M&L for cement concrete 75mm thick type D-2, 1:4:8 (using 40mm graded crushed stone aggregates) as in sub base complete all as specified and directed. |
| 48 | M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors surface set and jointed in neat cement slurry and pointed with whiteor colour cement to matchover and including 15mm thick screed bed in cement mortar 1:6 complete all as specified & directed. |
| 49 | M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in skirting/dado surface set and jointed in neat cement slurry and pointed with whiteor colour cement to matchover and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 50 | Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified & directed. |
| 51 | M&L for glazed ceramic coloured tiles of size 300x450x7mm thick in vertical surfaces of wall set and jointed in neat cement slurry and pointed in coloured cement to match over 10mm thick rendering in CM 1:6 complete all as specified and directed. |
| 52 | M&L Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rounding of edges, rubbing and polishing complete all as specified and directed. |
| 53 | S&F Vertical looking mirror (Bio- Med INC postural training mirror) of size 48cm x 120cm to fixed in verandah of barracks including necessary bolts and fittings complete all as specified and directed. |
| 54 | S&F 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 55 | S&F 25 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed |
| 56 | M & L for PVC (SWR) floor trap, plain with grating including jointing with solvent cement diameter of outlet in 75mm complete all as specified and directed. |
| 57 | S&F for 15 mmBib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 58 | S&F for Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 59 | Supply and fix PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and32mm PVC flush pipe. complete all as specified and directed. |
| 60 | Supply and fix PVC connection 15mm size with PTMT nuts of length 450mm. complete all as specified and directed. |
| 61 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches/wall or in floors 110mm bore complete all as specified and directed. |
| 62 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore complete all as specified and directed. |
| 63 | S&F PVC (SWR) bends any radius 110mmbore complete all as specified and directed. |
| 64 | S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed. |
| 65 | S&F PVC (SWR) bends any radius 75mmbore with access doors complete all as specified and directed. |
| 66 | S&F in repairWHB vitreous china (flat back or angle back type ) any size ,including cutting for pinning in ends size 550x400 mm including brackets ,out let pipe ,coupling ,connection pipe 450mm and CP piller taps complete all as specified and directed. |
| 67 | S&F Towel Ring of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats ( Min wt 90 gms) complete all as specified and directed. |
| 68 | S&F 600mmx450mm belvelled edge looking mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood with pvc / alluminium frame and fixed to wooden plugs with chromum plated brass screws cup washers. complete all as specified and directed. |
| 69 | S & F Vitreous China Urinal, Half stall type, white complete including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with 60 mm long brass screws, pointing around urinal back in cement, including all fittings cistern, brackets, flush pipe, spreader, push tap, waste coupling, grating, etc Complete set incl all fitting & fixtures complete all as specified and directed. |
| 70 | S & FVitreous china Squatting panOrissa pattern of size 580mx440mm wite with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding complete all as specified and directed. |
| 71 | S&F rotational moulded polyethylene water storage tanks 500 litre capacityincl(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I including dismantling and taking down existing water tank complete all as specified & directed. |
| 72 | S&F 20 mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe as in repairs complete all as specified & directed. |
| 73 | S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weigth 455gms) 20mm bore complete all as specified and directed. |
| 74 | Surface excavation n exc 30 cm deep and averaging 15 cmm deep and getting out hard/dense soil complete all as specified and directed. |
| 75 | Removing excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point. complete all as specified and directed. |
| 76 | M&L for broken stone or boulder hard core of gauge exc 63 mm but n exc 100mm deposited spread and levelled in layers n,exc 15 cm thick watered and rammed to true surface complete all as specified and directed. |
| 77 | M&L for 100 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub bases, sub flooring finished even and rough. complete all as specified and directed. |
| 78 | M&L for chequered cement concrete tiles with grey cement and pigments of size 300cmx300cmx20-25mm thick set, jointed and pointed in neat cement slurry over and including 15mm thick CM 1:6 screed bed in flooring complete all as specified & directed. |
| 79 | M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS-15658-2006 of 60 mm thickness M-35 grade complete all as specified and directed. |
| 80 | M&L for sand fillingunder floor or in foundations including watering and consolidation complete all as specified and directed.Note: Sand shall be sharp angular free from harmful chemical & organic matters. |
| 81 | S&F 4mm Plain mild steel wire, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hook eyes, etc complete all as specified and directed. |
| 82 | S&F Bulletin/Pin-in/Notice board (Green, Maroon or Blue) of size 120cm x 90cm (4\"x3\") to be fixed in verandah of barracks including necessary bolts and fittings complete all as specified and directed. |
| 83 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loosesoil. complete all as specified and directed. |
| 84 | M & L for PCC 1:4:8 type D-2(using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete etc complete all as specified and as directed |
| 85 | M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM (1:4)complete all as specified and as directed. |
| 86 | M&L for Plastering 15mm thick on other thanfair faces of stone masonry or concrete surfaces rendering to be finished fair & even without using extra cement in CM 1:4 on walls complete all as specified and as directed. |
| 87 | S & F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipsetc complete all as specified and as directed |
| 88 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 89 | M&Lfor Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 90 | M&L for Reinforced cement concrete M-25 (nominal mix) (using 20mm graded crushed stone aggregates) in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 91 | M&L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 92 | M&L for 100mm thick Plain Cement concrete type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) Laid in sub base flooring complete all as specified and directed. |
| 93 | M&L for 75mm thick Plain Cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) Laid in base of flooring complete all as specified and directed. |
| 94 | Excavation in post holes each n.exc 0.50 cum getting out. Returning filling in layers n.exc 25cm etc removal at surplus soil to a distance n.exc 50 mt and making good surface in hard/ dense soil complete all as specified and directed. |
| 95 | M&L for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) laid in base, mass concrete complete all as specified and directed. |
| 96 | S&F Steel work as in tubular / L post trusses,plates, purlins including special shaped washers etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St 240 complete all as specified and directed. |
| 97 | M&L forPlain Cement concrete type B-2, 1:2:4 (using 40mm graded crushed stone aggregate) Cement concrete in surface channels and drains complete all as specified and directed. |
| 98 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds,stopped ends etc. complete all as specified and directed. |
| 99 | M & L Mild steel TMT bars 5mm dia and over upto and including 10mm dia instirrups, spacers and binders including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed |
| 100 | M & L fir returning filling in any type of soil including spreading leveling watering and wel ramming in layers note exc 25cm thick cpmplete all as pecified and as directed |
| 101 | M & L for taking down copper/aluminium point wiring (light, fan, socket, power, security lights or bulkhead) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 102 | Taking down existing unserviceable Distribution boards / AC board with MCB\"s any size and any type complete all as specified and directed. |
| 103 | Material and labour for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FR-LSH unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall / ceiling including continous earth wire 1.5 Sqmm PVC insulated FR-LSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in walls and modular white plate covers with frame for mounting of modular switches/sockets etc complete including making good of disturbed surfaces of wall / ceiling / floor all complete all as specified and directed.(a) onelight point/ ceiling /exhaust fan point |
| 104 | (b) One three pin switch socket 6 Amps outlet on independent board. complete all as specified and directed. |
| 105 | (c) One three pin switch socket 6 Amps outlet on same board. complete all as specified and directed. |
| 106 | All as per item No 103 here in before but with cable 2.5 sqmm multi stranded copper FR-LSH wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 2.5 sqmm copper stranded conductor FR-LSH, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and directed. |
| 107 | All as per item No 103 here in before but with cable 4 sqmm multi stranded copper FR-LSH wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 4 sqmm copper stranded conductor FR-LSH, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and directed. |
| 108 | S&F in repair Modular switch 1 way 6A , 1-module complete all as specified and directed. |
| 109 | S&F in repairModular switch 1 way 16A with indicator, 1-module complete all as specified and directed. |
| 110 | S&F in repairModular socket, shuttered type, 6A - 3 pin 2 -module complete all as specified and directed. |
| 111 | S&F in repairModular socket, shuttered type, 6/16A -combined 2-module complete all as specified and directed. |
| 112 | S&F in repair 3 pin, 6 A, 250 V ceiling rose having terminal capacity 3 X 1.5 mm² IP 20 protection complete all as specified and directed. |
| 113 | Supply and fixing ceiling fans complete with blades,copper winding, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery not less than 210 CFM with service value more than equal to (≥)6.00, BEE Five star rated with brushless direct current motor (BLDC) white colour complete all as specified and directed. Make:Gold Medal cat part no.SCFS 500748/Bajaj Cat part No:ENERGOS 28/ Crompton Cat part No:ENERGION RIVIRA/Havells Cat part No:PRO 28BLDC/Luker Cat part No:ECO28NEOBLDC Regulator 222cmm |
| 114 | Supply and fix exhaust fan made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm sweep complete all as specified and directed.Make:Havells Cat part No:Vetil Air DX HS/Gold Medal EFS850310 AIR MAXX/Crompton VENTILUS250MM/Bajaj-Maxima neo/Luker cat part No:Viento LX10 |
| 115 | M&L for replacement of old unserviceacble light fitting withLED batten light fitting 20 Watts 4 feet surface / wall mounted aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy not less than 120 Lumen/Watt, rated llife 50000 Burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: Crompton CCS-100-20-65-HSL2-DP-NWH/ Havells ENDURALINEARPROBS20WLED865PCSSIND / Bajaj-BCLAB20WCWLEDXT |
| 116 | S & F 10 W surface / wall mounted 2 feet LED batten light fittinginput voltage range 250 V, input frequency 50Hz, efficacy not less than 100 Lumen/Watt rated life 25000 burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.Make:Crompton CCS-103-10-65-SL-DP-NWH/ Havells LHEXAZP7PN1W010 / PHILIPS BN021LED12S 6500K PSU GR / WIPROLL20-111-XXX-65NE3 /Bajaj-BCLAB10WLEDCWLED |
| 117 | S & F recess mounting LED down light fitting 2\" x 2\" of capacity 36 Watts powder coated white CRCA full glow,efficacy 120 lumen/watts rated life 50000 burning hours suitable for false ceiling pop/grid ceilingincluding making electrical connection from ceiling rose to light fitting complete all as specified and directed..Make:Crompton: LCTLRP-36-FO-CDL / PHILIPS RC308LED36S6500 / HAVELLS VENUSEXL2X2PLR36WLED865SWH/WIPRO-CRCO10R036HE57G4/Bajaj-BZRSQL43LXEWHODSD |
| 118 | M&L for replacement of old unserviceacble light fitting withLED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling complete all as specified and directed.Make:Crompton TRP-409-45-57-SL-GL-NSG /HAVELLS ENDURASUNDOWNSL45W LED765PASYBOPC/Bajaj-VISTAP45LWHPOPCSD |
| 119 | S&F in repairSingle pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) complete all as specified and directed. |
| 120 | S&F in repairof sheet metal enclosure TPN DBs with 200 Amps rated bus bar of 4 way 415 volts with blank plate complete with double door complete all as specified and directed. |
| 121 | S&F in repairsingle pole & neutral, double door, metallic distribution board 8 ways conforming to IEC 61439-3, suitable for flush / surface mounting with provision for DP MCB as incomer and SP MCBs as outgoing, complete all as specified and directed. |
| 122 | S&F in repairMCB SP 6 to 32 Amps \"C\" series complete all specified and directed. |
| 123 | S&F in repair MCB, single pole, 40 Amps, 240 Volts,connecting with copper lugscomplete all as specified and directed. |
| 124 | S&F in repair MCB three phase and neutral (TPN), 125 Amps, 415 Volts,connecting with lugs, complete all as specified and directed. |
| 125 | S&F in repair MCB single phase and neutral (SPN), 40 Amps, 230 Volts,connecting with lugs, complete all as specified and directed. |
| 126 | M & L for submain wiring using 3 runs of 6 Sq mm 1100 V grade single core FR-LSH flexible cable conforming to IS 694: 2010, having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade PVC recessed conduits, conforming to IS 9537 (Part- 3): 1983, of size not less than 25 mm NB, including taking down old submain wire and making good of disturbed surfaces of wall / ceiling / floor complete all as specified and directed. |
| 127 | Material and Labour for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less\" than 1.5meters below normal ground level, earth plate connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES 2009 (part I Specifications) connected to earth test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil and adequate quantity of common salt & charcoal for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I. cover with arrangement of hinge to 40x40x6mm C.I. angle iron frame, including 20mm dia G.I. pipe for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15 dia for earth lead protection complete incl taking down old onecomplete all as specified and directed. |
| 128 | M&L for earth continuity conductor 4 Sq.mm dia GI or steel wire complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail