| 1 | Demolition ofBrickwork or stone/bou-lder masonry, built in Cementmortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 2 | Removing building materilas such as bricks, stones, concrete, sand,soil etc to a distance upto 15Km, beyond the lead included in the rates, including loading, unloading and stacking at the destination. |
| 3 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 4 | M&L for Brickwork with Sub class \"B\"bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 in narrow widths including Cutting out bricks/stone, forming toothing for, and bonding new into old brickwork /stone masonry |
| 5 | M&L for Rendering 15mm thick CM 1:4 on fair faces of brick work or concrete surfaces and to be finished even and smooth(without using extra lime or cement) |
| 6 | M&L for Rendering 15mm thick CM 1:6 on fair faces of brick work or concrete surfaces and to be finished even and smooth(without using extra lime or cement) |
| 7 | M&L for Preparing newely plastered surface and priming with alkali resistant priming paint and applying 2 coats of oil bound distemper on walls over 3 mm thk wall care putty |
| 8 | M&L for preparation of old surfaces of walland applying two coats of oil bound distemper complete all as specified and as directed by Engineer-in-Charge. |
| 9 | M&L for complete removal of smoke, shoot,moulds,vegetation, moss and efflorescent salts and trading oil and greasy spots from surface areas using high-pressure water jet spray technology pressure (5000-10000)PSI , as part of surface preparation for repainting. by skilled labour complete all as directed by Engineer-in-Charge Note-: Rates are inclusiveall scafoldings used for up to the height of 4 storeys. |
| 10 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces including removal of old paint and preparation of surface all as specified and as directed by Engineer-in-Charge. |
| 11 | Taking downchowkats or framesN.exc 1.5 Sqmwith shutter (without taking of shutter from the frame. |
| 12 | Taking downchowkats with shutters(without taking off shutters from the frame) exc1.5sqm and n.exc 4 sqmeach |
| 13 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 14 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 15 | S&Ffactory made single extruded WPC (Wood Polymer Composite) 30mm thick wire mesh solid decorativeflush door shuter consisting of Density 500 Kg/Cum manufactured by an ISO certified company, door to be panelled with SS mosquito mesh and XTN aluminium mesh for additional strngth and safety purpose (conforming as per IS 4020).The door should be water proof,termite proof, fire retardant and having screw holding capacity.Door to be fixed to frame3 nos Stainless steel butt hinges size 100mmx25 mmx2mm (in each leafs) and 32 mm long steel screws drilled suitable to pass through both the walls of the MS tube. Other hardwares should be fixed with 19x6mm size steel screws etcall as per direction of Engineer- In- Charge. |
| 16 | S&F in repairs steel rolling shutters thickness of laths in 1mm, without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete gear operated type with bevel gear box and crank handle |
| 17 | S&F Ball bearing for rolling shutters |
| 18 | S&F safety lever locks mild steel with 4 levers for rolling shutters |
| 19 | S & F 100 mm size Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, typeB-11 |
| 20 | S&F Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed 150mm long. |
| 21 | S&F 200mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed |
| 22 | S&F 100mm Extruded brass handles, fabricated type polished |
| 23 | Taking down steel/aluminiumwindows/ventilatorof any size with all fittingscomplete |
| 24 | Taking down carefully unserviceable aluminium/copperpoint wiring (light, fan, socket or power)including unserviceablelight fittings, switch board complete,switch sockets, ceiling roses, pendants, regulators, sockets, etcandremoving materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge. |
| 25 | Taking down carefully Tubelight fittings,up down lights, flood lights,security lights, any decorative lights etc. and making good to disturbed surface of wall and match with the existing surface.(Note:- Contractor should properly check fitting operational or not during taking down ) |
| 26 | M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and includingproviding PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed by Engineer-in-Charge. |
| 27 | One Exhaust Fan point controlled by one switch |
| 28 | All as per item No.3 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately). |
| 29 | S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-Charge. |
| 30 | S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 31 | S & F Ceiling rose, 3 way PVC insulated bodycomplete all as specified and directed by engineer in charge. |
| 32 | Supply & fixexhaust fans steel body AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed.Note:- Cost of making hole for Exhaust fan of required size at site is deemed to be included in quoted rates. |
| 33 | Refixing all old serviceable Tubelight fittings,up down lights, flood lights,security lights, any decorative lights etc and connetions in new or old position(walls,ceiling, floor etc) complete all as specified and directed by Engineer-in-Charge. |
| 34 | Refixing all old serviceable switchs,sockets, switch socket combination, regulators etc and connetions in new or old position(walls,ceiling, floor etc) complete all as specified and directed by Engineer-in-Charge. |
| 35 | Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface. |
| 36 | M&L for sub main wiring drawing through PVC conduit with Wiring alongwith earth wiresize2x2.5 sq. mm +1 x1.5 sq. mm earth wireof FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:-Two run of 2.5 sqmm wire and Onerun of 1.5 sqmm wire and One run of PVC conduit will be measured as one running meter. |
| 37 | Taking down cable XLPE of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface. |
| 38 | Supply lay and testing cable XLPE insulated screened beded,galvanized steel trip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 35 sq mm 3.5 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as directed by Engineer-in-Charge. |
| 39 | Supply lay and testing cable XLPE insulated screened beded,galvanized steel trip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 95 sq mm 3.5 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as directed by Engineer-in-Charge. |
| 40 | Supply lay and testing cable XLPE insulated screened beded,galvanized steel trip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 70 sq mm 3.5 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as directed by Engineer-in-Charge. |
| 41 | S & F cable jointing kit for 1.1 KV grade cable or straight through joint complete with Jointing material heat shrink type & accessories suitable for 3.5/4 core XLPE, arnoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specified and directed by Engineer-in-Charge. |
| 42 | S & F cable jointing kit for 1.1 KV grade cable or straight through joint complete with Jointing material heat shrink type & accessories suitable for 3.5/4 core XLPE, arnoured, Al conductor cable of size 70 to 95 sqmm,Indoor/Outdoor type complete all as specified and directed by Engineer-in-Charge. |
| 43 | Shifting of old LT panel to another location with disconnetion of existing cables properly and reconnecting cables to panel properly and all as specified and directed by Engineer-in-Charge. |
| 44 | Excavation in trenches n. exc. 1.5 M in width and 1.5 M in deep for laying of pipes and getting out in Soft / loose Soil complete as specified & directed by Engineer-in-Charge |
| 45 | Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25cm in soft/soil complete all as specified and directed by Engineer-in-Charge |
| 46 | Removing excavated material n. exc. 50 M away and depositing where directed at a level n. exc. 1.5 M above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 47 | M&L Sand cushioning for UG cable protection/ducts, consolidated sand compacted with clean dry sand all as directed and specified. |
| 48 | Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed by Engineer-in-Charge. |
| 49 | Supply and install hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of 1.5 TR |
| 50 | M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed. Note:- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 51 | S&FDistribution Board, 4 Way ,(SPN) ,Double door complete all as specified and as directed. Make : Indo Asian cat part No. 811807[Optipro] / Standard / Havells |
| 52 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 53 | Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps. |
| 54 | M&L for AC out door unit Stand factory made suitable for Split AC |
| 55 | M&L copper pipe 5/8\" 1/4\" and 3/8\" duly insulated with superlon sleeve insulation |
| 56 | M&L PVC pipe 15 mm dia for drain water |
| 57 | M&L for core cutting to out the suction and delivery lines from indoor to out door unitsuitable for Split AC |
| 58 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp |
| 59 | Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp |
| 60 | Supply and installation of Hot dip galavanised iron pole 7 mtr long sheet thickness 3 mm. C/s A/F - top = 70mm, bottom =130 mm, base plate 200x200x12 mm, long weatherproof reinforced door opening with junction box mounting arrangement but including of junction box with 4 Nos aluminium Bus bar and including 1.0 M long double arm bracket wich required as per site 180 degree angle or 60 degree angle made of 40NB B class pipe having top 70 mm, 20 dia threaded made to J shape M20x600mm long steel grade EN8 grade foundation bolts- 4 nos with nuts, templates and all complete as per approved drawing (with internal accessorises like connectors, one run of FRLS PVC insulated cable 1100 V grade with multistranded copper conductor of size 1.5 Sqmm3 core conductor as per required and mcb) . including taking down old rusted steel/pcc pole of any size by digging or cutting all as directed . Foundation RCC 1:1.5:3 shall be of size 550x550mm and depth 1500 mm with 8 nos. 12mm dia. tor bars as main bars and 8mm dia. tor bars stirrups @ 190 mm c/c as per approved drawing(Including form work). This reinforcement shall conform to IS:1786 latest edition. The foundation shall extend above sorrounding ground/driveway level for 200 mm and have slant 63mmdia. PVC sleeve cast insitu foundation for cable entry as per the drawing. Excavation, PCC, RCC,Form work,welding and reinforcement shall be deemed to be included in quoted rates. |
| 61 | S& F XLPE insulated armoured and pvc sheated heavy duty electric cable size 4 core ,16 Sqmm cross sectional areawith aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendmentlaid in tranches passing through pipes /ducts including testing completenote- rate is inclusive of cable gland & cable lugsNote -Excavation and earth work shall be measured and paid for separately under relevant item of schedule. |
| 62 | M&L for Earthing complete with galvanizedsteel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth lead wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc |
| 63 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in hard/dense soil for laying of cable trenches all as specified and directed by Engineer-in-Charge. |
| 64 | All as per item No.22Herein before but in hard dense soil |
| 65 | Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cmall as specified. |
| 66 | Removal of surplus soil(excavated soil) to distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point and all specified. |
| 67 | M&L for providing dry river sand / crush stone dust for cushioning to UG cable including punning down of sand in layers all as specified. Note :- Cushioning will be measured and paid after punning down. |
| 68 | Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed by Engineer-in-Charge. |