| 1 | B/R Portion Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level). |
| 2 | M&L for 25mm thick PCC 1:2:4 type B-0 (12.5mm graded stone aggregate) as in level course with finshining in cement concrete surface even and rough to receive screed bed complete |
| 3 | M&L 75mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate)complete as in level course with finishing in cement concrete surface even and roughto receive screed bed complete |
| 4 | M&L 75mm thick PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection incl finishing even and smooth w/o using extra cement. |
| 5 | M&L for providing PCC 1:2:4 type B-0 as in roof kerbs or mud stops rouded or chamfered on edges (using 12.5mm graded stone aggregate) complete all as specifed and directed. |
| 6 | M&L 100 mm thick PCC (1:4:8 ) type D-2 as in sub base finished even and roughcomplete all as specified and as directed. |
| 7 | M&L moorum/red bajri filling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed by Engr-in-charge |
| 8 | M&L for broken stone or boulders Hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified. |
| 9 | M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard densecomplete all as specified |
| 10 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone agg) as in foundation filling and mass concrete complete all as specified and directed. |
| 11 | M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed. |
| 12 | M&L for Removing excavated soils to a distance exc 250m but n exc 500m and depositing where directed. |
| 13 | Demolition of brick work built in cement mortar all as specified |
| 14 | M&L for brick work with sub class `B’ bricks, straight on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 15 | M&L for 15mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces using WPC where ever requiredas per manufacturerer\"s instructions and finishing the surface even and smooth (without using extra cement) etc. incl finishing even and faircomplete all as specified NOTE -WPC shall be measured and paid separetely. |
| 16 | Supply only WPC complete all as specified and directed. |
| 17 | M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and fair without using extra cement complete all as specified and directed. |
| 18 | M&L for preparation of newly plastered surfaces of wall applying a layer of wall care putty 2mm thick (averaging) , finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 19 | Preparing new plastered or unplastered surfaces of walls and applying 2mm thick wall care, putty and two coats of distemper oil emulsion, white or tinted over a coat of primer, complete all as specified and directed. |
| 20 | M&L for 40mm thick damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate complete all as specifed and directed. |
| 21 | M&L for RCC Type B1 1:2:4 (using 20mm aggregate) for Beams, column, cantilevers, bressummers, lintels over 1.5m span complete all as specifed and directed. |
| 22 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 23 | -ditto- all as per item No.10 above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders complete all as specified and directed. |
| 24 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams etc , rough finish surfaces of concrete complete all as specified and as directed |
| 25 | Dismantling plain or corrugated steel sheeting, any gauge, thickness as in roof etc., coverings complete all as specified and directed. |
| 26 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet0.50mmthick of any colour having tensile strength of 550 MPAas in roof covering /cladding to wall, fixed with self tapping screws as specified complete all as specified |
| 27 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws as specified. |
| 28 | Dismantling wrought iron or mild steel work of any description not otherwiseprovided for |
| 29 | S&F MS work as in wind ties for roof including securing bolts complete all as specified and as directed. |
| 30 | S&F framed work such as grills,gratings, etc with ends of bars shouldered and / or riveted or forged into spikes; framed guard ; barred iron doors; ladders ; framed balusters; walk ways; railing and simillar work Con-forming to Fe 290 Gde E-165. |
| 31 | Dismantling framed work timber scantlings 40 sq. cm and over in section, in any position |
| 32 | S&F rolled mild steel sections channel angle Tee section and in tubular sectionas in main and cross beams, hip and jack rafters; purlins,post where connected to common rafters and running rails fixed with angle cleat or other connecting plates conforming to Fe 410-W Gde-E-250, quality A complete all as specified and directed. |
| 33 | M&L for two coats of synthetic enamel painting over a coat of red oxide zinc chrome primer on steel surfaces over 10cm width or girth including preparation of surface complete. |
| 34 | Taking down chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete. |
| 35 | Taking down chowkats or frames exc 1.50 sqm but n.exc 4.00sqm incl iron mongry each. |
| 36 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Including toughened glass of any colour) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 37 | Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in Charge. (Including toughened glass of any colour) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made made sepreately. |
| 38 | S&F Sheet glass 6.3 mm thick tinted glass and glazing in squarescomplete all as specified and directed. |
| 39 | M&L Vitrified tiles 8 to 10 mm thick light shade (square/ rectangular) polished, area of each tilesexc 0.42sqm but not exceeding 1.00 sqm in floors etc. set and jointed in neat cement slurry and hite or coloured cement to match not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match as in floor etc , all as specified. |
| 40 | M&L Vitrified tiles 8 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles exc 0.42sqm but not exceeding 1.00 sqm, in skirting/dado, vertical etc. set and jointed in neat cement slurry and hite or coloured cement to match not exceeding 0.36 sqm but over screed bed or bedding layer 10mm thick 1:4 on vertical surfaces/skirting complete all as specified and as directed |
| 41 | S&F Decorative Stainless steeltubular curtain rail of 25mm dia incl six nos curtain ring per running mtr and one number of brackets on each end and one no of globe on each end of the rod per opening of door / window (make and materail approved by Engineer-in-charge) complete all as specified and directed. |
| 42 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) any thickness, including cover fillets but without frame work. |
| 43 | S&F powder coated aluminium snap grid frame work for false ceiling size of grid 605 mm x 605 mm complete all as specified and directed. |
| 44 | Supply & fixing 4mm thick non asbestos E-board cememt building board for insulation and accoustic purpose, 600 x 600 mm size fixed with staples on snap grid as in ceiling complete all as specified and directed. |
| 45 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete. |
| 46 | M&L For Roof tiles, Mangalore pattern, interlocking at side joints on chhajja top, laid on 15mm thick screed bed or bedding in CM 1:4 complete. |
| 47 | M&L for Cement concrete tiles 20cm x 20cm x 20mm thick, m a c h i n e pressed; set jointed and pointed in neat cement slurry in floors, with grey cement and pigmentand cut and polished |
| 48 | E/M Portion Taking down carefullyaluminium/copper wiring of any size (for light, fan, socket or power etc complete) including fixture and fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc and making good disturbed surfaces of wall, roof etc to match with existing surface. |
| 49 | Supply & Fixing point wiring for one light point/ fan (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLSH)PVC cable drawn into & including medium grade PVC conduit (not less than 20mmouter dia ) with all fittings and accessories fixed concealed(including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) andsunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washersincluding one continuous run of PVC insulated (green colour) 1.5 Sqmm multistrandedcopper conductor cable earth wire and connected to earth dolly complete all as specified and directed Note:- wiring shall be done in colour coding as directed by Engineer in charge. |
| 50 | All as per item No.49 herein before but one socket outlet 5 Amps on the same board. |
| 51 | All as per item No.49 herein before butone 3 pin socket outlet 5 Amps independent. |
| 52 | All as per item No. 49 above but with 2.5 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 5/15 Amps socket. |
| 53 | All as per item No. 49 above but with 4 Sq mm two single core and 4 Sq mm one single core as earth wire for AC Point. |
| 54 | S&F ceiling rose surface bakelite3 terminal with base plate. |
| 55 | Supply and fixing of following rating of modular type ,white polycarbonate,switches, sockets, fan regulator suitable for250V, AC, 50Hz.Electrical supplyand as directed by Engr-in-Charge. (a) 6 Amp one way switch |
| 56 | (b) 6 Amp 2/3 Pin combined socket shuttered |
| 57 | (c) Modular Switch 1 way 16 Amp, 1 Module |
| 58 | (d) Modular Switch socket combination 16Amp, 6 Pin, 3 Module |
| 59 | (e) Steped type electronic fan regulator modular, 120W-2 module |
| 60 | Supply and fixing of following sizes of modular front plates, white with frame on existing boxes complete as required.(a) 2 Module |
| 61 | (b) 3 Module |
| 62 | (c) 4 Module |
| 63 | (b) 6 Module |
| 64 | (c) 8 Module |
| 65 | Supply and fixing anodised rust proof 18 SWG MS box, flush type offollowing sizes (to be of same make as modular switches and sockets)to berecessed in wall/gypsum partition complete as required :- (a) 75mm x 105mm x 50mm deep (1-2 Module) |
| 66 | (b) 75mm x 105mm x 50mm deep (3 Module) |
| 67 | (c) 75mm x 105mm x 50mm deep (4 Module) |
| 68 | (d) 75mm x 210mm x 50mm deep (6-8 Module) |
| 69 | Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive ofjunction/terminal boxes, all fittings and accessories fixed concealed with and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DBincluding cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existingold sub main wiring complete all as specified.Note :1 The cost of earth wire is included in the quoated rates. 2.Two run of 6 sqmm, one run of 6 sqmm and one run of PVC conduit will be measured as one unit ie one running metre” |
| 70 | Supply and fixing LED lights fitting 1x 20W (warm/milky white as required on site), 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and life of tube light not less than 50,000 hours.completeall as specified and directed..Make Havells cat pat LUMILINEBS20WLED865SPCWH or equivalent of phillips/wippro/Bajaj/Surya complete Note:- LED tube light shall be purches to get minimum 2 year warrenty of material from manufracturer. |
| 71 | Supply & Fixingsheet metal enclosure for DBs(double door type)single pole and neutral 12 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 72 | Supply & Fixingsheet metal enclosure for DBs(double door type)single pole and neutral 8 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 73 | Supply & Fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 40 TO 63 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed . |
| 74 | Supply & Fixing 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of single pole 5 to 32 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed . |
| 75 | M&L for taking down ceiling fans / wall mounted fans of any size / sweep after disconnecting the wire from existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, taking out burnt/damaged winding, bushes & cleanig of stator androtor incl etc. Rewinding with 26/27 SWG of enamelled copper winding wire replacement of bearing /bushes, condencer2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexible core twin core not less than 1.5 meter in length and make the fan operational with a guarantee period of one year after installing the repair fan complete all as specified and directed. |
| 76 | Supply and fixing wall bracket decorative light fixture with lamp 9 watt LED complete all as specified and directed. |
| 77 | Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type(warm/milky white as required on site) with high efficiency PMMAdiffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, life of tube light not less than 50,000 hours including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make Havells/Phillips/Bajaj/C&S Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. |
| 78 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-Charge. |
| 79 | S&F sheet metal enclosure with socket plug top and MCB single pole and netural enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amp 240 Volts complete. |
| 80 | S & F LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make : Havells cat pat HEXAFT10WLED857SSYMBOPC or equivalent cat part in makephillips/wippro/Bajaj & C&S .Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. |
| 81 | M&L for earthing complete with galvanized sheet earth plate electrodes 60x60x6.3 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point of galvanized Iron/ steel of size 75x75x25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed. |