Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-01-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-01-2026 |
| 2 | 06-01-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-01-2026 |
| 3 | 24-12-2025 | Corrigendum 4 | Date | 06-01-2026 |
| 4 | 24-12-2025 | Corrigendum 3 | BOQ | 06-01-2026 |
| 5 | 22-12-2025 | Corrigendum 2 | Date | 31-12-2025 |
| 6 | 16-12-2025 | corg1 | Date | 31-12-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/slabs/blankets , any thickness, including frame (upto any height). Complete all as specified and as directed. |
| 2 | Supplying and fixing at any places of wall panelling (upto heights upto 5.80 mtr)and fixingonframe work grid with glasswool accordingto following specifiacationwool Gypserra™ C-stud Wall Lining with Fultone 12.5 mm Tile includes 34x48x36x0.5mm Gypserra™ C-stud {Material-IS 513, Y/S-300Mpa, Finish - AZ150 (IS 15961)} placed at 297.5mm c/c in 32x50x32x0.5mm Gypserra™ floor and ceiling channel {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961}. Floor & Ceiling channel is anchored to the floor & True ceiling using Gyproc® Rawl plug Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} /Hilti X-GN20MX anchor fasteners at 600mm c/c in center line manner. 50x32x32x0.5mm Gypserra™ floor channel to be cut & bend & bracing at every 1200mm c/c vertically. Floor channel is cut-bend & fixed to brick wall with Hilti HPS-1 (Ø6x40mm) Impact anchor. |
| 3 | Floor channel to be wrapped with 70µ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. A Gypserra™ noggin channel {Material-IS 513, Y/S-300Mpa, Finish - AZ150 (IS 15961)} of 48x0.5mm width has to be provided at the horizontal joints of the two boards. Then Resin bonded glass wool of 24kg/M3 and 50mm thick is placed between the studs and noggin channels, for NRC 0.85 -0.88. Saint Gobain Gyproc Single layer of 12.5mm Fultone 12.5mm Tile (meets requirement of specification mentioned under DAR no. 12.52.4 in Delhi Schedule of rates (DSR)), of size 595x595mm having four squared edges, 18% perforation area of board & hole size of 9.7mm square shape with center borders of 48mm and side borders of 30mm, backed with non-woven tissue, to be screw fixed with Gyproc® Drywall screws of 25mm at minimum spacing of 300mm at center and 150mm at periphery. Finally edges are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc® Pro Fill Jointing Compound Air Dry (Conforms to AST) and incl board painted with a coat of primer and two coats of plastic emulsion of any colour. Make- India Gypsume , knauf USG, AMF. Complete all as specified and directed. |
| 4 | Supply & Fixing of KCS Mineral Fibre Acoustical Suspended Ceiling System with 12 mm thick SCALATiles and incl KCS Suprafine 15mm Face Exposed Grid and incl suspenders and fasterners complete. (upto ceiling height 5.8 mtr). Make - \" Armstrong or Equivalent\"The ceiling board fissured visual with acoustical punctures, Humidity Resistance NRC 0.5 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C-423 standard, CAC of 30db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, ColourGlobal White, Fire Performance of class 0/1 as per BS 476 Part 6/7and Class A as per ASTM E84 with 15mm Tegular 15 BE edge and 8mm drop in module size of 600 x 600mm. suitable for Green Building application, with Recycled content of up to 30%. The tile/boards shouldbe certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product.Properties of Tile Relevant Standards,Core Material Mineral Fibre Panel Dimensions 600 x 600 m (Nominal) /593 x 593 mm (Actual) Panel Thickness 12 mm Panel Weight 2.5 kg/m2 Recycled Content Up to 46 % Noise Reduction Co-efficient 0.5 ASTM C-423 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz)Ceiling Attenuation Class 30 dB ASTM E1414Fire Properties Class 0/1 Class A BS 476 Part 6/7 ASTM E84Light Reflectance 85% ASTM E-1477 Thermal Conductivity 0.052 - 0.057 W/mK Environmental Certifications GRIHA GreenPro Dimensional tolerances ±3mm |
| 5 | Note : (i)SUSPENSION: The tile shall be laid on KCS Suprafine 32ith 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. |
| 6 | Note : (ii)Suspension System Details Base Material Hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability Construction Method Roll formed double stroked rotary stitched construction to mechanically lock together the two metal layers of the vertical web Deflection Loading 15 kg/m with deflection limit less then L/360 as per ASTM C635 Pull-out Strength 100 kg Main Runner Dimensions 3600(L) x 38(H) x 15(W) mmCross Tee Dimensions 1200/ 600(L) x 38(H) x 15(W) mm Cross Tee End Detail The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam” Wall Angle dimensions 3000(L) x 19(H) x 19(W) mmMain Runner Rout Spacing 150 mmHanger-wire Material Galvanized Steel with 0.7 micron coating Hanger-wire Dimensions 2.5 mm Ø x 1800 mm Hanger-wire Tensile Strength 344-413 MPa Hanger-wire Pull Strength 110 Kgs |
| 7 | Note : (iii)INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using KCS suspension system (specifications above) at 1200mm maximum. The First/Last KCS suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be KCS wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per KCS recommended procedure.KCS SUSPENSION SYSTEM accessories supplied by KCS consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners). |
| 8 | Dismantling of Chair care fully and same to be refixing in same position after completion of requisite work and incl cost of any small fitting if required to install the chairNote :- If chair damaged or broke down while taking it out, the contractor will get it make good or replace with new chair athis own cost. |
| 9 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillar etc but excluding ashlar facing dressed stonework and precast concrete surfaces complete all as specified and directed by Engineer-in-Charge. |
| 10 | M & LPCC 1:2:4type B-1 using 20 mm graded stone aggregate as in floor/paving etc and incl contraction joint as required,incl demolition of old PCC of any description or any type/thickness complete all as specified and directed. |
| 11 | Cutting openings, through brick walls made of any mortar for door, window,(OPENING FOREXUAST FAN AT HEIGHT OF 5.5 MTR FROM FFL)and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. and incl making good jambs /circular portion with plaster complete. |
| 12 | Taking down of glass louver from existing alu ventilator and S & F 5 mm thick clear glass in existing alu ventilator frame incl alu beading / member or any fitting requitred to fix in the same, complete all as specified and directed |
| 13 | M&L brick work with fly ash modular bricks straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 14 | M & L 10 mm thick rendering on brick work or concrete surface in cement mortar 1:4, mixed with water proofing compoundas per manufracturer instruction, surface finished even and smooth, including taking down cement plaster of any description on brick or stone walls, ceiling etc including raking out joints, hacking for key, scrubbing down with water at any height etc and incl cost ofliquid water proofing complete all as specified and as directed. |
| 15 | Taking down cement plaster of any description on brick or stone walls, ceiling etc including raking out joints, hacking for key, scrubbing down with water at any height etc |
| 16 | M & L for preparation of newly plaster surfaces of wall and applying three coat of white wash complete all as specified and directed. |
| 17 | M & L Granite 20 mm thick(of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plateforms and likeincluding pointing in white cement(1:2) using marble dust with admixture of pigment to match with shade of granite over & incl 15mm thick screed bed built in CM 1:4, including rounding of edges wherever required, including dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed. |
| 18 | M & L vitrified ceramic tiles 9 to 10mm thick (square/rectangular) light shade polished, area of each tiles not exceeding 0.36 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm screed bed in cement mortar 1:6, including dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. |
| 19 | Description allas per ser item No 14.00above but in vertical surface including 10 mm thick rendering in cement mortar 1:4, including dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. |
| 20 | M & L for applying two coats of plastic emulsion paint including primer on old painted surfaces of wall of any description over 10 cm width or girth, not otherwise described, complete all as specified and directed. |
| 21 | Complete removal of existing treatment on wall/roof projections rubbing and scrapping with sand paper/ grit to make surface clean, free from dust, loose paint etc by skilled labour, complete all as specified and directed. |
| 22 | M & L for providing and applying minimum 1mmto 2mm thick wall care INTERIOR/ PUTTY over prepared surface to achieve the surface even and smooth for painting, complete all as specified and directed. |
| 23 | S & F (in repair) Solid PVC Wall Lining consisting of 5 mm thick printed or wood grain printed colour PVC sheet inclusive of solvent cement and fixing at site on and incl PVC frame as per specifications and driwing in SSR pt II, complete all as specified and directed. (Note : Including PVC fillet as required) |
| 24 | M & L 12mm thick Plywood, grade BWP, type BB fixed with screws to timber frame work complete all as specified and directed |
| 25 | M&L mild steel framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ;barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks, door shutter/gate and similar work conforming to Fe-290 Gde E-165 complete all as specified. |
| 26 | M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed |
| 27 | M & L second classwrought hard-wood in framed work. Complete all as specified and directed. |
| 28 | M & L for preparation of old treatedWood or Wood basedsurfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 29 | M & L Preparation of New wood or previously untreated surfaces of any description , not otherwise description, over 10 cm width or grith apply two coat of synthetic enemel paint (ordinary tint) over a coat of pink primer complete all as specifed and directed. |
| 30 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles of size 595 x 595 mm of approved texture (pre-finished state), design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225 : 1987, Noncombustible as per BS tiles 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions Note : The rates include for:(a) Use of all scaffoldings and cradles including hoisting and lowering. (b) Shifting of movable cupboards and furniture as required and replacing in position. |
| 31 | M&L Rendering on fair faces of brick work or concrete surfaces of wall 15 mm thickin CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed. Note :-The Rates includes for (a) Thickness of plaster key in joints, etc.(b) Arrises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth, except in thecase of mud plaster and leeping where angles etc. of any girth are included.(c) Scoring surface of plastering for key, where the surface is not required to be finished fair.(d) Curing of plastered surface.(e) Cleaning stains and dripping mortar from floors and walls, etc. |
| 32 | M&L Rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceiling and finishing the surfaces even and smooth complete all as specified and directed. Note :-The Rates includes for (a) Thickness of plaster key in joints, etc.(b) Arrises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth, except in thecase of mud plaster and leeping where angles etc. of any girth are included.(c) Scoring surface of plastering for key, where the surface is not required to be finished fair.(d) Curing of plastered surface.(e) Cleaning stains and dripping mortar from floors and walls, etc. |
| 33 | M&L for preparation of newly plastered surfaces of ceilings and apply three coat of white wash complete all as specified and directed. |
| 34 | M & L for preparation of newly plastered surfaces ofwall & concrete and applying 1mm thick Wall Care Putty including preparation complete all as specified and directed. |
| 35 | M&L for applying 1mm thick Wall Care Putty on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 36 | M&L for applying two coats of oil bound distemper on wall or concrete over a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 37 | M&L preparation of old painted surfaces and applying one coat of white wash on ceiling complete all as specified and as directed. |
| 38 | The rates (from Sch Item- 31 to Item - 35) include for:(a) Use of all scaffoldings and cradles including hoisting and lowering.(b) Taking down, cleaning as directed and refixing blinds and fittings, picture rods, cornice poles and small items of builder’s hardware such as door knobs, finger plates, escutcheons, hooks etc. which are not required to be painted.(c) Use of dust sheets and other coverings for the protection of fixtures, fittings, furniture, etc.(d) Shifting of movable cupboards and furniture as required and replacing in position.(e) Work in patches (over one square metre each) including matching with existing work and marrying in at the edges.(f) Removing all splashes, drops, dirt, etc. and leaving premises in a clean state. |
| 39 | Taking down copper /aluminium point wiring (light, fan, bell,socketor power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc.Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc. |
| 40 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site. |
| 41 | Taking down carefully copper/aluminium Sub main wiring of any size fromsurface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 42 | Taking down existing fire detectorof any type after disconnecting all necessary electricalconnections and deposit to MES store yard of AGE E/M No II complete all as specified and as directed. |
| 43 | M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceilingwith and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module,for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for the following complete for One light / fancontrolled by one, one way switch 5/6 Amps all as specified and as directed . |
| 44 | Description all as per ser item No. 40.00 above but for one 3 pin, 5/6 amps socket outlet point on independent boardcontrolled by one, one way 5/6 amps switch |
| 45 | Description all as per ser item No. 40.00 above but for one 3 pin, 5/6 amps socket outlet point on same boardcontrolled by one, one way 5/6 amps switch |
| 46 | M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceilingwith and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module,for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one 15A socket point independentcompleteincl taking down of old unsv point wiringall as specified and directed. |
| 47 | Description all as per ser item No. 43.00 above here in before butusing 4.0 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of4.0 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point) |
| 48 | S&F in replacement of Ceiling rosethree terminals surface bakelite type, AC, 50 HZ, 230V complete all as specified and directed. |
| 49 | S&F modular switch1 way 6 A , 1 modulecomplete all as specified and directed. |
| 50 | S&Fmodular socket 6 Amps 2/3 pin combined2 module complete all as specified and directed. |
| 51 | S&Fswitch modular type 16 A, 1 module complete all as specified and directed. |
| 52 | S&F socketmodular type multipurposes 6/16 A, 2 module complete all as specified and directed. |
| 53 | S&F MCB DB SPN 8 way ,IP-43, IK 09, double door type with metal doorwith 200 Amps rated bus bar ,230 volts, 50 Hz complete all as specifed and directed. |
| 54 | Supply & FixMCB SPN 32 Amps current rating \"C\" series 10 KA breaking capacitycomplete all as specified and directed. |
| 55 | Supply & FixMCB SP 6 to 32 Amps current rating \"C\" series 10 KA breaking capacitycomplete all as specified and directed. |
| 56 | M & L sub main wiring with 2 runs of 06 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good disturbed surfaces complete all as specified and directed.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. |
| 57 | Taking down existingexhaust fan/ceiling fan of any sweep after disconnecting necessary connection from ceiling rose to fan and deposit to MES store yardcomplete all as specified and as directed |
| 58 | S & F for energy efficient exhaust fan of 450 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing brick wall for fan baseincluding writting the MES Number with synthetic enamel paintcompelte all as specifiedand directed.Note :- Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). |
| 59 | S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan teriminal includingwritting the MES Number with synthetic enamel paintcomplete all as specified and as directed. |
| 60 | Supply , fixingrigid non metallic PVC conduit fixed conceiled/on wall wherever necessary with all connectedaccessories20 mm dia forcable TV connectionscomplete all as specified and as directed |
| 61 | Replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground levelwith top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 4.0 sqmm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc completeall as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified. |
| 62 | Refixing of fire detecrtor any type obtained from taking down including checking of electrical connections etc all necessary connection and testingall as specified and directed. |
| 63 | Fixing only for LED luminaire600 mm x 600 mm square LED panel 35/36 watts, recess mounted light fittingo btained from item No 1 with necessary electrical connections complete all as specified and as diredcted |
| 64 | M&L for single pole and earth encolsure with a two pin and earth plug with socket 240 Volts, 50 Hz complete with onesingle pole MCB SP 20 Amps complete all as specified and directed. |
| 65 | S & Ffor modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 66 | M&L for LED ceiling fitting 33 to 36 watts, 2 ft x 2 ft fittings suitable for aluminium grid ceiling, lumen out put ≥ 122 lumen/ watt,THD < 10% environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source,incl inbuilt drivers suitable for Grid ceiling complete with atration of aluminium frame work wherever necessary during installation all as specified and directed. |
| 67 | Refixing of ceiling fans any type obtained from taking down including painting , checking and electrical connections etc all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail