| Sl. No. | Item Description |
| 1 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed. |
| 2 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 5 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level n. exc. 1.5 metre above the starting point complete all as specified and directed. |
| 6 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 7 | M&L for Hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface with Broken stone or boulders complete all as specified and as directed. |
| 8 | M&L for Hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface with Broken bricks complete all as specified and as directed. |
| 9 | M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 10 | M&L for PCC (1:2:4),type B0 ( using 12.5 mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 11 | M&L for RCC (nominal mix) Type B1 (1:2:4) (20 mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.(Note: Reinforcement shall be measured & paid separately) . |
| 12 | M&L for RCC (1:2:4) (nominal mix) type B1 (20 mm graded aggregate) in Beams, cantilevers, bressummer, lintels over 1.5 span complete all as specified and directed. |
| 13 | M&L for RCC (1:2:4) (nominal mix) Type B1 (20 mm graded agg) in column, pillars, piers, post and struts complete all as specified and as directed. |
| 14 | M&L for brick work with sub class \"B\" burnt clay bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 15 | M&L for brick work with sub class \"B\" burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 16 | M&L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) with using water proofing compound complete all as specified and as directed.Note:Water Proofing Compound will be measured and paid separately. |
| 17 | Use and waste of Formwork to sides of concrete foundations, footings bases of columns below GL and similar work, rough finished surfaces of concrete complete all as specified and directed. |
| 18 | Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surface of concrete complete all as specified and as directed. |
| 19 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions etc rough finished flat surface of concrete complete all as specified and as directed. |
| 20 | S&F factory made 35 mm thick 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 21 | S&F for 125 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic filmcomplete all as specified and as directed. |
| 22 | S&F for 100 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic filmcomplete all as specified and as directed. |
| 23 | S&F aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionsor cast aluminium alloy, length of bolt of 300 mm anodised finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed. |
| 24 | S&F Mild steel butt hinges, Medium grade, 100 mm size , complete all as specified and directed. |
| 25 | S&F for 100 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed. |
| 26 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 27 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 28 | M&L for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 29 | M&L for TMT bars 6 to 8 mm dia , as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 30 | M&L for TMT bars 6 to 10 mm dia in stirrups, spacers and binders, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 31 | S&F for rolled mild steel work as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc.conforming to Fe-290 (Gde-E-165) complete all as specified and as directed. |
| 32 | S&F rolled mild steel section sectionsany type as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, FE -290 Gde E-165, complete all as specified and as directed. |
| 33 | S&Frolled mild steel in roof trusses (framed),trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. steel conforming to Fe 410-W (Gde-E-250) quality A complete all as specified and directed. |
| 34 | S&F steel windows with side hung shutters including box type hinges with steel handle and steel peg stay complete without glazing bars, dovetailed or welded complete all as specified and as directed. |
| 35 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed. |
| 36 | S&F pressed steel door frames conforming to IS : 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm x 60 mm, profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers including PCC (1:2:4) type B-1 for filling of hollow section complete all as specified and as directed. |
| 37 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 38 | S&FPre-painted galvalume aluminum zinc coating (AZ-150) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 39 | S&F Pre-painted galvalume aluminum zinc coating (AZ-150) GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed. |
| 40 | M&L for 75 mm thick,plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/ hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed. |
| 41 | M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as sub base of flooringcomplete all as specified and directed. |
| 42 | M&L for 40 mm thick PCC (1:2:4)type B0 (using 12.5 mm graded stone aggregate) as in sub base of floors finished even and smooth with using extra cement, complete all as specified and directed. |
| 43 | M&L for non skid ceramic colouredtiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed. |
| 44 | M&L for Non Skid ceramic colouredtiles 7mm to 8mm thick, premium quality conforming to IS-13755,(square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 sqm in verticle surface etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thickbacking coat in cement mortar (1:4), complete all as specified and directed. |
| 45 | M&L for non-skid, ceramic, coloured tiles 8 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, including 15 mm thick screed bed or bedding in cement mortor (1:6) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed. |
| 46 | M&L for coloured 450x350x7-8 mm thick glazed ceramic tileson vertical surfaces such as skirting, dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thickbacking coat in cement mortar (1:4) , complete all as specified and directed. |
| 47 | M&L for prepolished, chequered cement concrete tiles of size 25cmx25cmx22mm thick, as in floors etc, over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed. |
| 48 | M&L for Kota stone slab 20-25 mm thick in floor laid over and including 20 mm thick screed bed or bedding layer of cement morter (1:6)and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing all as specified and directed. |
| 49 | M&L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 10mm thickbacking coat in cement mortar (1:4) including rubbing and polishing all as specified and directed. |
| 50 | M&L for 60mm thick Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658- 2006 M-35 grade, laid as directed to any shape complete all as specified and as directed. |
| 51 | M&L for rendering 10 mm thick wall on other than fair faces of brick work or concrete surfaces in cement mortar in (1:6) andfinished even and smooth (without using extra lime or cement) complete all as specified and as directed. |
| 52 | M&L for rendering 20 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10mm thick each layer) in cement mortar in (1:4) using water proofing compound in top layer andfinished even and smooth (without using extra lime or cement) complete all as specified and directed.Note:Water Proofing Compound measured and paid separately. |
| 53 | Supply only liquid Water Proofing Compound ISI marked of approved make complete all as specified and directed. |
| 54 | M&L for applying three coats of white wash on new Wall surfaces including preparation of surface, complete all as specified and directed. |
| 55 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of cement primer on wall complete all specified and directed. |
| 56 | S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squaresn.exceeding 0.50sqm in each pane complete all as specified and directed. |
| 57 | M&L for preparing of new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 58 | S&F 15mm bore dia Stop valves fancy type, chromium plated, with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 59 | S&F in repairs Vitreous China wash hand basin, white, flat back, size 550x400mm with coupling , waste, chain and plug andporcelainstopper, brackets, with and incl 32mm dia 90cm long PVC waste down pipe, but excluding taps complete all as specified and directed. |
| 60 | S&F in repairs PTMT(half or full threaded) waste coupling 40mm for sink (min weight 32mm - 45gms/40mm - 60gms) complete all as specified and as directed. |
| 61 | S&F in repairs, 15mm cromium plated Bib taps, cast copper alloy with crutch orbutterfly handle, fancy type,screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. |
| 62 | S&F cromium plated Pillar taps 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks & fly-nuts, screwed for iron pipe, complete all as specified and directed. |
| 63 | Supply, laying, connection and testing, 16mm (outer diameter), CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches or on walls/ceiling or laying in floors complete all as specified and as directed. |
| 64 | All as per Item No.63 here in above but 20mm |
| 65 | S&F for CPVC brass threaded elbow suitable for 16mm outer diameter CPVC pipe complete all as specified and as directed. |
| 66 | All as per Item No.65 here in above but 20mm |
| 67 | S&F for CPVC brass threaded tee suitable for 16mm outer diameter CPVC pipe complete all as specified and as directed. |
| 68 | All as per Item No.67 here in above but 20mm |
| 69 | S&F for CPVC brass threaded union suitable for 16mm outer diameter CPVC pipe complete all as specified and as directed. |
| 70 | All as per Item No.69 here in above but 20mm |
| 71 | S&F in repairs 15mm bore, PVC connection pipe 600 mm long with PTMT nuts at both ends complete all as specified and as directed. |
| 72 | S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 73 | S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed. |
| 74 | S&F PVC (SWR)junction single, (Single T) equal or unequal, 110 mm bore complete all as specified and directed. |
| 75 | S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 76 | S&F for 75 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed. |
| 77 | S&F PVC (SWR)junction single, (Single T) equal or unequal, 75 mm bore complete all as specified and directed. |
| 78 | S&F PVC (SWR) floor trap dia of outlet 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 79 | M&L PVC (SWR) gully trap 125/110mm setting and jointed with solvent cement complete allas specified and directed. |
| 80 | S&F Tubular towel rail, 20mm dia, D type, 60cm long Brass Chromium plated between flanges complete all as specified and as directed |
| 81 | S&F sink with drainage board, made out of stainless steel 1.00mm thick, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915x460mm and bowl size 410X330X160mm complete all as specified and as directed. |
| 82 | S&F 50 mm bore, high density polyethylene pipes (HDPE) of pressure rating 6 kgf/ cm2 in waste pipe for WHB and sinks,complete all as specified and as directed. |
| 83 | S&F 600mmX450mm bevelled edge mirror of selected quality 5mm thick glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated cup washers and screws complete all as specified and as directed. |
| 84 | M&L for forming contraction joint (dummy joint) 65mm deep x 10 mm wide by using diamond cutter and filled withGrade B sealing compound (SHALIMAR or equivalent), all as specified and as directed. |
| 85 | M&L for point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLHSPVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in and including 1.6mm thick mild steel sunken terminal box of suitable size with 3mm thick hylam sheet top cover fixed with suitable size ofbrass screws suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed. |
| 86 | All as per Item No.85here in above but for One 2/3 pin socket outlet 5/6Amps on independent board |
| 87 | All as per Item No.85 here in above but forOne 2/3 pin socket outlet 5/6 Amps on the same board with other switches. |
| 88 | All as per Item No.85 here in above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm |
| 89 | S&FSwitch piano, flush type, single pole, one way switch5 Amps ISI marked complete all as specified and as directed. |
| 90 | S&F socket outlet, 2 in 1, 3 pin, 5 Amps, 240V bearing ISI marked complete all as specified and as directed. |
| 91 | S&F Switch socketcombination 2 in 1,5 Amps flush type, ISI marked complete all as specified and as directed. |
| 92 | S&F switch socket out let combination multipurpose 3/5 pin, 15/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) complete all as specified/directed. |
| 93 | S&F angular/batten holderPVC/Polycarbonate suitable for batten fittings including oneinverter LED Lamp of 9W of complete all as specified and directed. |
| 94 | S&F Ceiling rose surface PVC, 3 terminals 65x50mm ISI marked complete all as specified and as directed. |
| 95 | Supply, fixing and connecting exhaust fan metal body with louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 380mm,including drilling holes in wall for fixing and connecting with suitable size copper wire complete all as specifiedand as directed. |
| 96 | S&F LED fitting 1x20 watts, 220volts AC decorative box inverter type with driver and of aluminium housing, holder LED tube light conncting up to 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 97 | S&F 35 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. including all fixing arrangement and taking down old light fittings of any type complete all as specified and as directed. |
| 98 | S&F in repair of MCB Distribution board SPN 8 Way for mountingSPN/ SP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossyfinished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smoothfinish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed. |
| 99 | S&F MCBSPN \"C\" curve 40 Amps with breaking capacity 10 KA, complete all as specified/directed. |
| 100 | S&F miniature circuit breaker (MCB) SP, 240 Volts,6 to 32 Amps, \"C\" Series, 10KA capacity complete all as specified and directed. |
| 101 | S&F ceiling fan energy saving and fency type complete with min 03 blades, down rods, remote, anti dust coating, double bearing and accessories, 30-40 watts,230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. 5 star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 102 | M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size,fixed to wall/ceiling etc including one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor(FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed.Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets. |
| 103 | M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground levelwith the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete as specified and as directed. |
| 104 | Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size any type from LT overhead line including all jumper, cross arms, clamps, bolts, nuts etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and as directed |
| 105 | Dismantling cross-arms of M.S. channel or angle sections etc. complete and stackingaside serviceable materials for re-use with in 50m and removing unserviceable materials from site of workcomplete all as specified and as directed. |
| 106 | Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and as directed. |
| 107 | Dismantling of GI earth wire 4.0mm or any size complete all as specified and as directed. |
| 108 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, nominal cross sectional area of main conductor 95 Sqmm, 3.5 core stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 109 | All as per Item No.108 here in above but 70 Sqmm 3.5 Core. |
| 110 | All as per Item No.108 here in above but 35 Sqmm 3.5 Core. |
| 111 | All as per Item No.108 here in above but 25 Sqmm 3.5 Core. |
| 112 | All as per Item No.108 here in above but 16 Sqmm 4 Core. |
| 113 | All as per Item No.108 here in above but 10 Sqmm 4 Core. |
| 114 | All as per Item No.108 here in above but 25 Sqmm 2 Core. |
| 115 | All as per Item No.108 here in above but 16 Sqmm 2 Core. |
| 116 | All as per Item No.108 here in above but 10 Sqmm 2 Core. |
| 117 | S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in Trenches over Sand Cushion for laying UG Cable Protection, complete all as specified and as directed. |
| 118 | Boring of holes horizontal for laying not less than 80/50/40/32mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed.Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate. |
| 119 | S&F in repair 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete all as specified and as directed. |
| 120 | All as per Item No.119 here in above but 50 mm bore. |
| 121 | All as per Item No.119 here in above but 80 mm bore. |
| 122 | M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments. |
| 123 | Supply and layingun-reinforced precast concrete cable cover , class LV, type -1, flat of size 250x150x40mm, used for power cables upto and including 11 KV with minimum breaking load capacity upto 200kg as per IS: 5820:1970, complete all as specified and directed. |
| 124 | S&F precast RCC cable route indicator with embrossing mark as \"LT CABLE \"duly painted with approved colour of size 75cm x 15cm x 7.5cm alongwith foundation size 75cm x 30 cm x 30 cm complete all as specified and as directed. |
| 125 | Supply, install,testingand commissioning outdoor type LT panel of size 1m x 1m x 0.5m, withlatest IP factory made totally encloseddust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and copper bus bar of 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (FP-II)Note : Foundation to be included in the quoted priceIncoming :-(a)MCCB, 4 Pole, 250A, 415 V, 36 KA. (I/C).(b) Phase indicator lamps (RYB) - set of 3(c)Copper bus bar 4 strip - 300 amps (length should not be less than 0.7 m)(d) Internal connection by copper strip from MCB/MCCB to busbar and busbar to MCCB/MCB etcOutgoing :-(a) MCCB, 4 Pole, 160 Amp,415 V, 36 KA - 01 No (b) MCB, TPN, 63 A, 240 V, 18 KA- 04 No. (c) MCB, TPN, 32 A, 240 V, 18 KA- 03 No. |
| 126 | Supply, install,testingand commissioning outdoor type LT panel of size 1.2m x 1.2m x 0.6m, with latest IP factory made totally encloseddust and vermin proof , double steel shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door painted with powder coated paint and Copper bus bar 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC platform all around the panel board complete with the following items:- (FP-I, III & IV) Note : Foundation to be included in the quoted priceIncoming :-(a)MCCB, 4 Pole, 160 A, 415 V, 25 KA. (I/C). Thermal Magnetic release(b)3 Phase LED Voltmeter Cl-1(c) Phase indicator lamps (RYB) - set of 3(d)Copper bus bar 4 strip - 300 amps (length should not be less than 0.7 m)(e)Internal connection by copper strip from MCB/MCCB to busbar and busbar to MCCB/MCB etcOutgoing :-(a) MCCB, 4 Pole, 100 A, 415 V 25 KA - 01 nos(b)MCB, TPN, 32 A, 240 V, 18 KA- 03No. (c) MCB,TPN, 63A, 240 V, 18 KA- 03 Nos. |
| 127 | S&F PVC cable Junction Box IP66 \"halogen free and weather proof\" for out door installation size not less than 200 x 150 x 100 mm suitable for street light incoming and outgoing cables up to 10 to 25 sqmm 4 core (with terminal) & inclusive of MCB SP 10 Amp, 60A 04 strip aluminium Bus Bar, including nuts,bolts,cable glands & MS clamps fixed to pole allas directed. |
| 128 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire unarmoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade passed throuh PVC conduit medium grade of size Min 20mm complete all as specified and directed. |
| 129 | Supply, install,testingand commissioning outdoor type LT panel of size 0.6m x 0.6m x 0.5m , with latest IP65 factory made totally encloseddust and vermin proof , double steel shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door painted with powder coated paint and Copper bus bar 200 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC platform all around the panel board complete with the following items:- (Bus Bar Panel). Note : Foundation to be included in the quoted price(a) Copper bus bar 4 strip of 200 Amps having hole drilled on Bus Bar for fixing of cables. |
| 130 | M&L for dismantling the all cable from panel, poles, MCB Main DBs taking out the cable loop stretching out the cable, carrying out end termination with new lugs, proper thimbling, fixing the joint kits connecting back to the new/existing panel board by means of nuts, bolts & washers of any size any type all as directed by engineer in charge. Note: (i The work includes necessary excavation to take out the loop,and laying the cable, putting proper cable protection bricks using the old retrived bricks and refill the area properly and spreading any surplus soil. |
| 131 | S&F cable straight through joint for 1100 volt, out door type terminal heat shrinkable type joint complete with all jointing material and accessories suitable for 3.5/4 core 70-150sqmm, complete all as specified and directed. By engineer-in-charge. |
| 132 | S&F cable straight through joint for 1100 volt, out door type terminal heat shrinkable type joint complete with all jointing material and accessories suitable for 2/3.5/4 core 25-50sqmm, complete all as specified and directed. By engineer-in-charge. |
| 133 | S&F cable straight through joint for 1100 volt, out door type terminal heat shrinkable type joint complete with all jointing material and accessories suitable for 2 core 10-25sqmm, complete all as specified and directed. By engineer-in-charge. |
| 134 | Supply, install,testingand commissioning of dual nature switch smart timer based automatic street light control panel. the panel should be suitable for 3 phase 15 KW power load. the contral panel should be maintenance free in design and setting accessible via mobile app (with bluetooth connectivity) the mobile app should be allow users to (customize the ON & OFF timing based on Natural light lux level sensor or local sunset/sunrise (astro) or manual time setting or combination of all options) . the mobile app should also have facility to set input voltage range. the contral panel have 2 smart timers along with suitable power contactors and incoming -outing MCBs should be inclosed in a pole/ wall mountable rust proof, electric shock proof, termite proof and FRgrade polycarbonate enclosure conforming to IP66 and circuit should also have provision for manual operation (i.e.sensor by pass option & controlling current phase selection option at least from 2 phase). Note : the hanging arrangment on pole/wall to be included in the quoted price |