Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-12-2025 | Corrigendum1 | BOQ | 27-12-2025 |
| Sl. No. | Item Description |
| 1 | Material and labour for chipping and removing carefully existing concrete work by low-impact hammer, breaking without causing damage to the adjoining structure, including cleaning the surface and disposal of debris outside the premises, complete all as directed by the Engineer-in-Charge.Note: Hard concrete shall not be removed by force; work shall be carried out using controlled, non-impact chipping methods to prevent structural distress. |
| 2 | Demolition of reinforced cement concrete by cutting concrete slab, chajjas, etc., and lowering gently in any position, including cutting reinforcement bars as required to facilitate demolition, complete all as specified and directed by the Engineer-in-Charge. |
| 3 | Demolition of brickwork or stone masonry built in cement mortar, including all quoins, arches, and pillars, etc., but excluding ashlar facings, dressed stonework, and precast concrete articles, complete all as specified and directed. |
| 4 | Material and labour for brickwork with subclass “B” bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar (1:6), complete all as specified and directed by the Engineer-in-Charge. |
| 5 | Material and labour for brickwork with subclass “B” bricks, straight or curved on plan to any radius, half-brick thick walls, built in cement mortar (1:4), complete all as specified and directed by the Engineer-in-Charge. |
| 6 | Material and labour for cleaning existing reinforcement using wire / rotary wire brush, removing all loose material, dust, and rust, followed by applying two coats of alkaline rust converting primer (FEOVERT or equivalent) conforming to ASTM-B-117, on cleaned rebars.After six hours of curing between coats, apply protective coating IPNET-RB to reinforcement, complete all as specified and directed by the Engineer-in-Charge. Notes: Work shall be executed by authorised applicator of approved manufacturer. |
| 7 | Material & Labour for Replacement of corroded steel reinforcement with TMT bars (CRS) of appropriate size, where 30% or more of cross-section has reduced, including dismantling and removal of rusted bars and fixing new reinforcement properly tied and bound in position, complete all as specified and directed by the Engineer-in-Charge. |
| 8 | Material & labour for carry out application of Bi-polar migratory corrosion inhibitor EPCO-KP-100/ Protectsil CIT/Ferogard 903 on concrete surface (this inhibitor shall have migratory kind of properly which permits the material to migrate to a virtual extent of 100 mm, through pores of concrete, inhibitor the corrosion and de-passivating the Electro-chemical reaction. It should have properly to attack as well as cathode, which is purely alkaline in nature (pH-9.5), So it has no carcinogen activity with concrete all as per manufacturer\"s instructions and directed. Notes: Work shall be executed by authorised applicator of approved manufacturer. |
| 9 | Material and labour for drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12 mm dia and 50–100 mm deep, complete all as under:(i) Cleaning of holes using air blower prior to fixing nozzles.(ii) Fixing of nozzles: Insert 12 mm dia Rohibb Teflon nozzles in cleaned holes, ensuring outlet alignment with grouting gun. Fix using thixotropic epoxy putty to ensure sealing and cure for minimum 12 hours.(iii) Cutting of nozzles after completion of grouting without damaging structural elements.(iv) For cracks up to 2 mm wide, fix injection nozzles directly over cracks at 6 to 9 inch intervals using drilling machine and fast-setting epoxy putty, curing for 2–3 days. Seal between ports with epoxy.(v) For cracks 2–5 mm wide, drill staggered holes along crack edges at 6-inch spacing and fix with epoxy putty.(vi) Seal the crack face with liberal application of epoxy putty.Make: Dr. Fixit / STP / Choksey Chemical (as approved) or make given in Appx B to PS. Notes: Work shall be executed by authorised applicator of approved manufacturer. |
| 10 | Material and labour for injecting cement slurry grout in ratio 1:2 (cement : water) with superplasticizer (Supercom-100) 250 ml per 50 kg cement, using mechanical mixer to maintain continuous suspension.Injection to be done using grout pump at 0.5 kg/cm² pressure until grout flows from outlet nozzle, ensuring complete filling of voids, all as specified and directed by the Engineer-in-Charge. Notes: Work shall be executed by authorised applicator of approved manufacturer. |
| 11 | Material and labour for injecting low-viscosity MONOPOL (3–5 cps), high molecular weight type, using mechanized injector gun, including mixing of material components (Part A & B) as per manufacturer’s instructions, maintaining pressure at exit between 0.5 to 1.0 kg/cm².Grout to be injected through pre-fixed nozzles in structural members such as beams, RCC walls, and columns @ 100 ml per nozzle, repeating as necessary till absorption is complete, all as specified and directed by the Engineer-in-Charge. Notes: Work shall be executed by authorised applicator of approved manufacturer. |
| 12 | Providing and applying structural grade bonding agent EPIBOND-21-LP, prior to plastering or mortar application, conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bonding between old and new concrete, complete all as per manufacturer’s instructions and as directed by the Engineer-in-Charge.Notes: Work shall be executed by authorised applicator of approved manufacturer. |
| 13 | Providing and applying building up the profile of structural members by applying polymer modified air-cured mortar (MONOBOND / LW+), mix ratio (1:5:15 = 1 monobond : 5 cement : 15 sand), in 30 mm thick layers to damaged areas, including levelling, profiling, and finishing as per manufacturer’s instructions and as directed by the Engineer-in-Charge. Notes: Work shall be executed by authorised applicator of approved manufacturer. |
| 14 | Providing and applying jacketing around columns using Micro Concrete (Molith-MC, M40 grade), including formwork, drilling holes, fixing shear anchors, and placing micro-concrete, complete for all lifts and levels as per specification and manufacturer’s instructions.Note: Reinforcement steel shall be measured and paid separately. Quoted rate includes formwork and micro-concrete application complete.Work shall be executed by authorised applicator of approved manufacturer. |
| 15 | Taking down cement or cement-lime plaster of any description on brick or stone walls, including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed by the Engineer-in-Charge. |
| 16 | Providing and applying 15 mm thick plaster in cement mortar (1:4) using ready-mix pre-packed dry mix mortar, mixed with waterproofing compound on fair faces of brickwork or concrete surfaces on external walls, finishing surface even and smooth without using extra cement, including mixing, curing, and transportation, complete all as specified and directed.Note: Waterproofing compound shall be measured and paid for separately as “Supply Only.” |
| 17 | Providing and applying anti-algal water-based elastomeric exterior wall coating on newly plastered surfaces, including complete surface preparation, primer coat (coverage 8–10 sqm/L), and two coats of finish paint (base coat 4.2–4.7 sqm/L and top coat 6–6.5 sqm/L), applied by roller, complete as specified and directed.Notes:(a) Work shall be executed by authorised applicator of approved manufacturer.(b) Each coat shall be approved by GE prior to application of subsequent coat.(c) Contractor shall submit minimum 5-year warranty certificate from manufacturer, GE shall ascertain that RARs shall be release post submission of 5-year warranty certificate from the manufacturer. |
| 18 | Providing and applying 15 mm thick plaster in cement mortar (1:6) using ready-mix pre-packed dry mix mortar on internal brick or concrete surfaces, finished even and smooth without using extra cement, including mixing, curing, and transportation, complete all as specified and directed. |
| 19 | Material & Labour for complete removal of existing treatment and providing & applying anti-algal water-based elastomeric exterior wall finish on old plastered surfaces, including surface preparation, primer (8–10 sqm/L), and two coats of elastomeric paint by roller, complete all as specified and directed.Notes:(1) Work shall be executed by authorised applicator of approved manufacturer.(2) Each coat shall be approved by GE prior to application of subsequent coat.(3) Contractor shall submit minimum 5-year warranty certificate from manufacturer, GE shall ascertain that RARs shall be release post submission of 5-year warranty certificate from the manufacture. |
| 20 | M&L for preparation of new plastered surface of wall and applying two coats of oil emulsion distemper over a coat of primer on 3 mm thick wall care putty (JK/Birla), complete all as specified and directed. |
| 21 | M&L for complete removal of existing surface treatment and applying two coats of oil emulsion distemper over a coat of 3 mm thick wall care putty (JK/Birla), complete all as specified and directed. |
| 22 | M & L for rendering 5 mm thick in cement mortar (1:3) on fair faces of ceilings, finished even and smooth without using extra cement, complete all as specified and directed. |
| 23 | Material and labour for preparation of new plastered surface of ceiling and applying two coats of oil emulsion distemper over a coat of primer on 2 mm thick wall care putty (JK/Birla), complete all as specified and directed. |
| 24 | M&L for preparation of old plastered surface of ceiling and applying two coats of oil emulsion distemper, complete all as specified and directed. |
| 25 | M&L for preparation of old painted steel surfaces over 10 cm width or girth, and applying one coat of synthetic enamel paint, including necessary scaffolding for high-rise buildings, complete all as specified and directed. |
| 26 | M&L for preparation of old painted wooden surfaces over 10 cm width or girth, and applying one coat of synthetic enamel paint, including external windows and scaffolding for high-rise works, complete all as specified and directed. |
| 27 | M&L for preparation of old treated wooden surfaces over 10 cm width or girth and applying one coat of synthetic varnish, complete all as specified and directed. |
| 28 | M&L for preparation of newly painted steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 29 | M&L for preparation of newlywooden surfaes of any description over 10cm width or girth and applying two coats ofsynthetic enamel paint over a coat of pink primer incl preparation of surfaces. |
| 30 | Taking up or down 15 mm bore steel tubing and connections,complete all as specified. |
| 31 | Taking up or down 20 mm bore steel tubing and connections,complete all as specified. |
| 32 | Taking up or down 25/32mm bore steel tubing and connections, complete all as specified. |
| 33 | Taking up or down 40/ 50mm bore steel tubing and connections,complete all as specified. |
| 34 | S&F 15 mm bore CPVC pipes of pressure rating 10 Kg/cm², fixed complete to wall, ceiling, or in floor, with all fittings and wherever concealed, complete all as specified and directed. |
| 35 | S&F 20 mm bore CPVC pipes of pressure rating 10 Kg/cm², fixed complete to wall, ceiling, or in floor, with all fittings and wherever concealed, complete all as specified and directed. |
| 36 | S&F 25 mm bore CPVC pipes of pressure rating 10 Kg/cm², fixed complete to wall, ceiling, or in floor, with all fittings and wherever concealed, complete all as specified and directed. |
| 37 | S&F 32 mm bore CPVC pipes of pressure rating 10 Kg/cm², fixed complete to wall, ceiling, or in floor, with all fittings and wherever concealed, complete all as specified and directed |
| 38 | S&F 50 mm bore CPVC pipes of pressure rating 10 Kg/cm², fixed complete to wall, ceiling, or in floor, with all fittings and wherever concealed, complete all as specified and directed |
| 39 | S&F in repairs 15 mm fancy-type chromium-plated bib tap approved make, cast copper alloy, with crutch or butterfly handle, screwed down, for iron pipe or brass ferrule, fixed complete all as specified and directed. |
| 40 | S&F in repairs stop valve / angle valve (ISI marked), fancy typechromium-plated, screwed down, high pressure, with butterfly handle, screwed both ends for 15 mm dia pipe, complete all as specified and directed. |
| 41 | S&F in repairs stop valve(ISI marked), 20 mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or unions, fixed as in repairs, complete all as specified and directed. |
| 42 | Supply and fix in repairs vitreous china vanity cabinet wash basin set, unbreakable type, with wash-down basin, cabinet, swan-neck fancy CP pillar tap of approved make, complete with mirror and all necessary fittings and connections, fixed to wall and floor, complete all as specified and directed by the Engineer-in-Charge. |
| 43 | S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 44 | Supply and fix in repairs wall-mounted ceramic western-type water closet (commode) with concealed flush accessories and 10-litre flushing cistern, including connection to existing CI/PVC soil pipe, fixed complete all as specified and directed. |
| 45 | Supply and fix in repair stainless steel tissue paper roll holder, of approved design and make, fixed with screws and accessories complete all as specified and directed. |
| 46 | Supply and fix in repairs brass chromium-plated shower rose, 100 mm dia, with 160 mm long shower arm, casted round shape, wall-mounted, including connection to 15 mm bore pipe, complete all as specified and directed. |
| 47 | Supply and fix in repairs decorative glass shelf, 600 mm long, 8 mm thick with chromium-plated railing and D-type stainless steel brackets, wall-mounted, of approved design and pattern, complete all as specified and directed. |
| 48 | Supply and fix in repairs Health Faucet (ABS body), of approved make, complete with 1.0 m long spiro-chrome flexible tube and wall hook, suitable for 15 mm dia pipe, including making connections and fixing in position complete all as specified and directed. |
| 49 | Supply and fix in repairs 15 mm fancy-type chromium-plated two-way bib tap, cast copper alloy, with crutch or butterfly handle, screwed down for iron pipe or brass ferrule, fixed complete all as specified and directed. |
| 50 | Supply and fix in repairs stainless steel towel rack, 600 mm long, of approved make and design, including necessary wall brackets and fixing, complete all as specified and directed. |
| 51 | Supply and fix in repairs stainless steel soap dish holder, fixed to wall with brass screws, of approved design and make, complete all as specified and directed. |
| 52 | Supply and fix in repair decorative glass corner shelf, 300 mm diameter, 8 mm thick with stainless steel railing, fixed to wall with D-type stainless steel bracket, of approved design and make, complete all as specified and directed. |
| 53 | Supply and fix in repairs Low-Density Polyethylene (LDPE) pipe, 40 mm bore, pressure rating 6 Kg/cm², fixed complete to walls, ceilings, or floors for washing machine / wash basin outlets, complete all as specified and directed. |
| 54 | Supply and fix in repairs rotational moulded polyethylene water storage tank, 2000 litres capacity, hoisted and fixed in position, including 20 mm PTMT high-pressure ball valve with epoxy-coated aluminium rod and high-density plastic ball (min weight 210 gms), dismantling old tank, complete all as specified in SSR Part-I. |
| 55 | Supply and fix in repairs rotational moulded polyethylene water storage tank, 1000 litres capacity, hoisted and fixed in position, including 20 mm PTMT high-pressure ball valve with epoxy-coated aluminium rod and high-density plastic ball (min weight 210 gms), dismantling old tank, complete all as specified in SSR Part-I. |
| 56 | Supply and fix rotational moulded polyethylene water storage loft tank, 300 litres capacity, hoisted and fixed in position including 20 mm PTMT high-pressure ball valve with epoxy-coated aluminium rod and HD plastic ball (min weight 210 gms), dismantling old tank, complete all as specified in SSR Part-I. |
| 57 | S&F as in repairs Gun-metal, globe or gate valves (ISI marked) 50mm bore dia., with iron wheel head, screwed both ends for iron pipe and fixedcomplete all as specified |
| 58 | Supply and fix in repairs ball brass valve(ISI marked) , 50 mm bore, high pressure, with polythene float and fly nut, screwed for iron pipe, fixed complete all as specified and directed. |
| 59 | Material and labour for cement concrete (1:2:4), type B-1, using 20 mm graded stone aggregate, as in flooring, base course, or padding, complete all as specified and directed. |
| 60 | Removing and demolishing existing waterproofing of any type, any thickness, and in any position, including disposal of debris off the premises, complete all as specified and directed. |
| 61 | M&L for rendering 10mm thick cement plaster in cement Mortar 1:4 on concrete surfaces as on roof finished even and smooth without using extra cement complete all as specified and directed. |
| 62 | Material & labour for providing water proofing treatment with (a) Apply one coat bituminous primer @ 0.25 kg/m².(b) Apply blown bitumen grade 85/25 heated to ~180°C at 1.20 kg/m² per coat.(c) Lay APP polymer-modified membrane 4 mm thick with non-woven polyester reinforcement (≥4.0 kg/m²) by torch application (An overlap of 100mm and 150mm shall be provided on sides and ends respectively)(d) Apply another coat of blown bitumen grade 85/25 at 1.20 kg/m².(e) Apply solar-reflective bituminous aluminium paint @ 0.10 kg/m².complete all as specified and directed by Engineer-in-charge.The work shall be carried out through authrorised applicator only. |
| 63 | Supply and lay machine-pressed concrete tiles 250 × 250 × 22 mm thick, set in neat cement slurry over and including 20 mm thick cement screed in CM (1:4), joints pointed in white or coloured cement to match, surface rubbed and polished smooth, complete all as specified and directed by Engineer-in-Charge. |
| 64 | Taking down chowkats or frames not exceeding 1.5 sqm each (without taking off shutters from the frame), complete all as specified and directed by Engineer-in-Charge. |
| 65 | Taking down chowkats or frames exc 1.5 sqm each but n.exc 4 sqm with shutters (without taking off shutters from the frame)complete all as specified and directed by Engineer-in - charge. |
| 66 | Taking down shutters of any description not exceeding 1 sqm each, complete all as specified and directed by Engineer-in-Charge. |
| 67 | Taking down shutters of any description exceeding 1 sqm but not exceeding 2 sqm each, complete all as specified and directed by Engineer-in-Charge. |
| 68 | S&F second-class hardwood (Sal or similar) plain, solid, straight chowkhats and frames, wrought, framed, rebated on solid, rounded or chamfered edges, put together with glue and pinned at joints, complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply and fix 30 mm thick flush shutters, solid-core type with blockboard core and commercial-type plywood faces on both sides, edges lipped with hardwood, complete all as specified and directed by Engineer-in-Charge. |
| 70 | S&F 30 mm thick second-class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass or gauze, divided into squares with plain, chamfered or rounded, mitred and rebated sash bars; edges of framing plain, chamfered or rounded; fitted with cut and mitred beads for securing glass; sizes of members as specified in SSR Part I, Section 8, Clause 8.24(b); supplied and fitted to second-class hardwood chowkhats, complete all as specified and directed by Engineer-in-Charge. |
| 71 | S&F solid PVC door frame of size 50 × 47 mm made out of 5 mm thick plain-colour PVC sheet reinforced with mild-steel square tube, fixed in openings as per drawing and specification, complete all as specified and directed by Engineer-in-Charge. |
| 72 | S&F factory-made solid PVC moulded door shutter 28 to 30 mm thick with 2.4 or 6 raised-panel design, consisting of 2 mm thick moulded PVC sheet on front face and 2 mm plain-colour PVC sheet on back face with particle-board core, complete all as specified and directed by Engineer-in-Charge. |
| 73 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm, fixed with stainless steel staples, complete all as specified and directed by Engineer-in-Charge. |
| 74 | S&F aluminium alloy sliding door bolt 300 mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section, including bolts and sliding bolts, complete all as specified and directed by Engineer-in-Charge. |
| 75 | S&F aluminium anodised barrel tower bolt 200 mm long, of extruded section, fixed complete all as specified and directed by Engineer-in-Charge. |
| 76 | S&F aluminium anodised barrel tower bolt 150 mm long, of extruded section, fixed complete all as specified and directed by Engineer-in-Charge. |
| 77 | S&F aluminium alloy handles 150 mm long, fabricated type from extruded section, ISI marked, complete all as specified and directed by Engineer-in-Charge. |
| 78 | S&F stainless steel butt hinges 125 mm long, medium weight, fixed complete all as specified and directed by Engineer-in-Charge. |
| 79 | S&F stainless steel butt hinges 100 mm long, medium weight, fixed complete all as specified and directed by Engineer-in-Charge. |
| 80 | S&F in repair 100 mm size mortice lock, 4-lever (vertical type) brass body, fixed complete all as specified and directed by Engineer-in-Charge. |
| 81 | M&L Mild Steel flat iron holdfasts, conforming to Fe-290 (Gde E-165), fixed in walls with cement concrete block (1:3:6) type C-1 as necessary, complete all as specified and directed by Engineer-in-Charge. |
| 82 | S&F floor door stopper, 140 mm long, aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge. |
| 83 | Dismantling old rusted G.I. frame work of any description, complete all as specified and directed by Engineer-in-Charge. |
| 84 | S&F grid 605 × 605 mm G.I. frame work for seamless ceiling, comprising of G.I. perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c; intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web 45 mm, suspended from soffit at 900 mm c/c with G.I. cleats and steel expansion fasteners, including ceiling section (not exceeding 1.2 m length) of 0.55 mm thickness having knurled web 50 mm and flanges 26 mm each with lips of 10.5 mm, fixed to intermediate channels with connecting clips at 457 mm c/c, complete all as specified and directed by Engineer-in-Charge. |
| 85 | S&F hangers 6 mm dia G.I. (up to 1200 mm length) for adjusting level, fixed to roof slab by means of ceiling cleats made from G.I. flat 40 × 3 mm size, 60 mm long, and expansion hold fasteners 12.5 mm dia × 40 mm long, complete all as specified and directed by Engineer-in-Charge. |
| 86 | M&Lin repair for false ceiling made out of 600x600x 6mmthick( non asbestos fiber cement designer/coloured) ceiliing board / tiles deep panel as per sample complete all as specified and directed by Engineer-in - charge. |
| 87 | S&F in repair 18/19 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative lamination and other side balancing white lamination, fixed with screws to framework of cupboard etc., including 6 mm thick teak wood beading all around, complete all as specified and directed by Engineer-in-Charge. |
| 88 | S&F in repair 12 mm MDF board, exterior grade, fixed with screws to framework of cupboards etc., complete all as specified and directed by Engineer-in-Charge. |
| 89 | S&F in repair 12 mm thick plywood, BWP type BB grade, fixed with screws to timber frame as in panelling, partition or base for loft tank etc., complete all as specified and directed by Engineer-in-Charge. |
| 90 | M&L 0.9 mm thick decorative textured finish laminate, Type 1, of approved shade, colour and pattern, fixed with adhesive as per manufacturer’s instructions, complete all as specified and directed by Engineer-in-Charge. |
| 91 | Taking down aluminium windows/ventilators of any size, without removing shutters from frame, including all accessories, complete all as specified and directed by Engineer-in-Charge. |
| 92 | Dismantling stone slab/tiles of any description or thickness in floors, laid and pointed in any mortar, complete all as specified and directed by Engineer-in-Charge. |
| 93 | M&L 18 to 20 mm thick mirror-polished, machine cut granite (any type) as in steps, jambs, pillars, cooking platforms or working tables, laid over 15 mm thick screed bed in CM (1:4), including pointing in white cement (1:2) with marble dust and pigment to match the shade of granite, complete all as specified and directed by Engineer-in-Charge. |
| 94 | M&L for tapering, rounding, or chamfering bottom and edges of stone slabs such as cills, jambs, window cladding, and forming grooves for lining or other similar work, complete all as specified and directed by Engineer-in-Charge. |
| 95 | M&L for door seal, EPDM closed-cell foam tape weatherstrip for doors and windows to seal the gap between floor or wall at doors/windows, complete all as specified and directed by Engineer-in-Charge. |
| 96 | S&F UPVC window of any size, sound proof, sound proofing to be done in three layers consisiting of 6 CLT + 1.52 PVB + 5 CLT fixed type/Open type where ever necessary , colour of window , weight of each window to be not less than 45.0 Kg (Make: Fenesta or equivalent approved by accepting officer) . Making the disturbed area good internal and external surfaces, to be matched with the existing treatment of viz plastering , painting or tiling complete including all fittings like jointing cleats glazing clips, rubber neoprone packing anodised aluminium snap beading screws etc rubber beading clips locking arrangement, handle,silicon sealent etc all as specified and directed.(Windows to fixed as per the instruction ofmanufacurer )complete all as specified and directed by Enginner -in- Charge |
| 97 | S&F UPVC sound proofdoor of profile frame high impact modified grade of 65 mm X 73 mm ) outer frame casement door type and sash of 65 mm X 105 mm (casement door type) wall thicknessof profile must be min 1.8(+-) 0.3 mm. Design must be as per the widthstandard cylinder and hook locking system handle double laminated glass on inner and outer side as per drawingcomplete all as specified and directed by Enginner -in- Charge(Doors to fixed(Windows to fixed as per the instruction ofmanufacurer ) |
| 98 | Supply & fixing in repairs powder coated aluminiumsections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such asglazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specifiedNote: - (i) Glass panes will be measured & paid separately. (ii)The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as requiredbut shall not be measured for arriving of weight.(iii) Minimum thickness of powder coating shall be 25 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area.(v)The size of aluminium sections shall be as perHQ CE(N) MZ TD drawing No TD/2021/01 to 05 |
| 99 | S&F in repair aluminium grill with suitable anodised frame (F/H section) fixed to existing window frame with C.P. brass or stainless steel screws @ 200 mm c/c, complete all as specified and directed by Engineer-in-Charge. |
| 100 | S&F in repair sheet glass 4.8 mm thick, selected quality, in square panes not exceeding 0.5 sqm each, fixed complete all as specified and directed by Engineer-in-Charge. |
| 101 | S&F in repair 4 mm thick sheet glass, ordinary quality, frosted on one side, not exceeding 0.5 sqm in each pane, fixed to aluminium windows, complete all as specified and directed by Engineer-in-Charge. |
| 102 | S&F in repair 15 mm thick toughened glass as in hinged doors, partitions, automatic or self-closing push/pull doors with necessary fittings and accessories, including edge polishing, cutting to shape, and drilling as required, complete all as specified and directed by Engineer-in-Charge. |
| 103 | S&F roller-type Venetian blinds made out of approved standard fabric of selected shade and texture, fixed in position with necessary brackets and fittings, complete all as specified and directed by Engineer-in-Charge. |
| 104 | S&F 5 mm thick pre-laminated PVC sheet fixed on aluminium framework for partitions, including solvent cement, rubber beading and necessary fittings, complete all as specified and directed by Engineer-in-Charge. |
| 105 | S&F 4 mm thick decorative laminated bakelite sheet, both sides laminated with approved shade, fixed as directed, complete all as specified and directed by Engineer-in-Charge. |
| 106 | Dismantling floor, hearth or wall tiling including cement-mortar bedding, removing serviceable tiles for reuse and removing rubbish off the premises, complete all as specified and directed by Engineer-in-Charge. |
| 107 | M&L non-skid ceramic tiles, coloured, 7 to 8 mm thick (square or rectangular), each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screed bed in CM (1 : 6), complete all as specified and directed by Engineer-in-Charge. |
| 108 | M&L glazed ceramic tiles, coloured, of approved make and size, on vertical surfaces such as skirting or dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15 mm thick backing coat in CM (1 : 4), complete all as specified and directed by Engineer-in-Charge. |
| 109 | M&L light-shade vitrified ceramic tiles 10 mm thick (square or rectangular) of approved colour and pattern, area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screed bed in CM (1 : 4), including dismantling of old tiles, complete all as specified and directed by Engineer-in-Charge. |
| 110 | M&L light-shade vitrified ceramic tiles 10 mm thick (square or rectangular), area of each tile not exceeding 0.36 sqm, fixed on vertical surfaces such as skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 10 mm thick backing coat in CM (1 : 4) and dismantling of old tiles, complete all as specified and directed by Engineer-in-Charge. |
| 111 | M&L machine-cut mirror polished Kota stone slabs 20 to 25 mm thick, laid in flooring over 15 mm thick screed bed in CM 1 : 4, jointed with grey cement slurry mixed with pigment to match the shade of the slab, rubbed and polished to a smooth finish, complete all as specified and directed by Engineer-in-Charge. |
| 112 | M&L machine-cut mirror polished Kota stone slabs 20 to 25 mm thick as in risers and treads of steps, skirting, dado or pillars, laid over 15 mm thick screed bed in CM (1 : 4), jointed with grey cement slurry mixed with pigment to match the shade, rubbed, polished and rounded at edges where required, complete all as specified and directed by Engineer-in-Charge. |
| 113 | M&L plain cement concrete (1 : 3 : 6) type C-2 using 40 mm graded stone aggregate, 75 mm thick, as in floor, plinth protection or paving, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 114 | M&L forming construction joints 50 mm deep and 10 mm wide, filled with sealing compound Grade ‘A’ in plinth protection, complete all as specified and directed by Engineer-in-Charge. |
| 115 | M&L plain cement concrete (1 : 4 : 8) type D-2 using 40 mm graded stone aggregate as in sub-base, complete all as specified and directed by Engineer-in-Charge. |
| 116 | S&F in repair aluminium door closer (die-cast body), hydraulically regulated, designation No. 2, universal type, suitable for shutters 701 to 850 mm wide and weighing 36 to 60 kg, fixed complete all as specified and directed by Engineer-in-Charge. |
| 117 | S&F in repair plain aluminium sheeting 0.71 mm thick, alloy 31000 H4, fixed in ridges, hips, valley gutters, drip and straight flashings, crumple joints, etc., with screws, complete all as specified and directed by Engineer-in-Charge. |
| 118 | M&L cutting holes in brickwork built in cement-mortar or cement-lime-mortar walls, half-brick thick or not exceeding one brick thick, complete all as specified and directed by Engineer-in-Charge. |
| 119 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundations, shafts, manholes, etc., not exceeding 10 sqm on plan, in hard/dense soil, getting out soil, complete all as specified and directed by Engineer-in-Charge. |
| 120 | Dismantling 200 mm dia reinforced-concrete drainpipes jointed in cement mortar, complete all as specified and directed by Engineer-in-Charge. |
| 121 | S&F 200 mm dia RCC pipe class NP-2, laid and jointed complete with collars, tested, complete all as specified and directed by Engineer-in-Charge. |
| 122 | M&L cement concrete (1 : 3 : 6) type C-2 using 40 mm graded stone aggregate as in bed to drainpipes, including forming cradle after laying and testing 200 mm dia RCC pipes, complete all as specified and directed by Engineer-in-Charge. |
| 123 | M&L plain cement concrete (1 : 3 : 6) type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge. |
| 124 | Demolition and breaking up CI drain pipescement concrete) set in cement mortar 100 mm and 75 mm all as specified and directed. |
| 125 | Supply & Fixing 110 mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 126 | Supply & Fixing 75 mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 127 | S&F PVC (SWR) bends 110 mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 128 | S&F PVC (SWR) bends 75 mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 129 | S&F PVC (SWR) branch piece, single Y type, 110 mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 130 | S&F PVC (SWR) branch piece, single Y type, 75 mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 131 | S&F PVC (SWR) vent cowl 110 mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 132 | S&F PVC (SWR) vent cowl 75 mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 133 | M&L in repair PVC (SWR) floor trap, plain type with grating, including jointing with solvent cement, 75 mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 134 | S&F in repair PVC stack clamps suitable for securing 100 mm dia PVC pipes, including stays and wall-fixing accessories, complete all as specified and directed by Engineer-in-Charge. |
| 135 | S&F in repair PVC stack clamps suitable for securing 75 mm dia PVC pipes, including stays and wall-fixing accessories, complete all as specified and directed by Engineer-in-Charge. |
| 136 | S&F in repair stainless-steel grating 125 mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 137 | Cutting into existing manholes for connection of new drainpipes, forming branch channels (½ round or ¾ section) in cement concrete (1 : 2 : 4) type B-1, rendering smooth finish, and making good benching as required for 200 mm dia pipes, complete all as specified and directed by Engineer-in-Charge. |
| 138 | Removal of excavated soil to a distance exceeding 1.5 km but not exceeding 5 km and depositing where directed, complete all as specified and directed by Engineer-in-Charge. |
| 139 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in Hard / dense soil, complete all as specified. |
| 140 | M&L for mild-steel TMT bars(CRS) 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends, and binding with and including mild-steel annealed wire not less than 0.9 mm dia, or securing with clips,complete all as specified and directed by Engineer-in-Charge. |
| 141 | M&L forMild steel TMT(CRS) bars 5mm dia and over upto and including 10mm dia in stirrups, spacers, binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge. |
| 142 | M&L forinjecting chemical emulsion for post-construction anti-termite treatment along the external wall below concrete or masonry apron at 2.25 litres per linear metre, including drilling and plugging holes and finishing the surface with white cement to match existing apron, complete all as specified and directed by Engineer-in-Charge. |
| 143 | M&L for post construction treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same |
| 144 | M&L Stainless-steel railing, grade 304, of approved section, embedded into wall/floor, including welding, fixing and polishing, complete all as specified and directed by Engineer-in-Charge. |
| 145 | S&Fmild-steel work, grade FG 150, machined, in brackets, framed work, walkways, gratings, railings, frames, manhole covers, dampers, stop-valve boxes, gate stops, balusters and similar articles, each exceeding 5 kg by weight, complete all as specified and directed by Engineer-in-Charge. |
| 146 | Removing debris of any kind, including loading into 5 to 7 cum capacity truck, conveying day-to-day to approved dumping point up to 50 km lead, including spreading, unloading and levelling, complete all as specified and directed by Engineer-in-Charge. |
| 147 | Dismantling old iron materials of any description, complete all as specified and directed by Engineer-in-Charge. |
| 148 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets, light fitting etc. removing materialsto store for keeping in safe custody or for taking credit (credit for above items should be made as per Pointconditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 149 | M & L for Point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated sheathed copper conductors 1100 volts grade drawn through & including PVC non-metallic double locked casing ISI marked with accessories fixed in wall/ceiling/truss including cutting chases, pinning in etc with PVC non metallic ISI marked terminal boxes concealed wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specifed and directed.Note: - PVC Casing caping wiring shall be provided where concealed wiring is not feasible (i.e. concrete surface/ beam/ column/ ceiling etc.) The same shall be deemed to included in the quoted rate.No extra cost shall be paid for the PVC casing caping item. |
| 150 | (a)One light point controlled by one switch SP one way. |
| 151 | (b)One ceiling fan point controlled with one 5A switch. |
| 152 | (c)One exhaust fan point controlled with one 5A switch. |
| 153 | (d)One 3 pin socket outlet 5Amps on independant board. |
| 154 | (e) One 3 pin socket outlet 5Amps on same board with other switches. |
| 155 | Material and Labour point wiring for 15 Amps socket complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic double locked casing and caping including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specifed and directed.Note: - PVC Casing caping wiring shall be provided where concealed wiring is not feasible (i.e. concrete surface/ beam/ column/ ceiling etc.) The same shall be deemed to included in the quoted rate.No extra cost shall be paid for the PVC casing caping item. |
| 156 | S&F Modular Switch, 6Amp, One way, 1 module, ISi marked complete all as specified and directed. |
| 157 | S&F Modular Switch, 16Amp, One way, 1 module, ISI marked complete all as specified anddirected. |
| 158 | S&F Modular Socket, 6 Amps, 2/3 pin combined 2 module, ISi marked complete all as specifiedand directed |
| 159 | S&F Modular Socket, 16Amps, 6 pin combined 2 module, ISi marked complete all as specified and directed. |
| 160 | S&F ceiling rose surface bakelite with ISI mark, three terminals complete all as specified and directed. |
| 161 | S&F Modular white cover plate with Frame 3 Module, ISI marked complete all as specified and directed, |
| 162 | S&F Modular white cover plate with Frame 8 Module, ISI marked complete all asspecified and directed, |
| 163 | S&F Modular white cover plate with Frame 12 Module, ISI marked complete all asspecified and directed, |
| 164 | S&F Modular metal flush box 3 module, ISI marked and including cutting hole in wall / ceiling/pillar etc and making good surface complete all as specified and directed. |
| 165 | S&F Modular metal flush box 8 module, ISI marked and including cutting hole in wall / ceiling/pillar etc and making good surface complete all as specified and directed. |
| 166 | S&F Modular metal flush box 12 module, ISI marked and including cutting hole in wall / ceiling/pillar etc and making good surface complete all as specified and directed. |
| 167 | Supply and fixing integrated LED batten 20 Watt (min 120 lumen/watt) , 4 feet long, full white in Engineering plastic battern with white acrylic cover with built in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 168 | Supply and fixing integrated LED batten 10 Watt (min 120 lumen/watt) ,, 2 feet long, full white in Engineering plastic battern with white acrylic cover with built in electronic driver, pre-wired and connecting up with twisted twin coreflexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 169 | S&F of New LED Bidg security light 45 Watt (min 120 lumen/watt) , indus series powder coated pressure die cast aluminiumhigh power LED bldg security light with heat resistant toughned glass with lens with IP66 Protection including 40 mm dia pipe bracket fixing on wall at any height with 02 nos of MS clamp of suitable size,complete all as specified and directed. |
| 170 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt (min 120 lumen/watt), 220 V AC recessed type with high Each efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr in charge. |
| 171 | S&F MCB DB SPN 12 way suitable for single phase AC supply, 230 V sheet steel powder painted enclosure double door type with minimum IP-43 degree of protection with built in 200 Amps copperbus bar, neutral link and earth link complete including flush off in wall with cutting and making good the disturbed surface including connection of circuits with copper pin terminals complete all as specified and directed |
| 172 | S&F MCB DB SPN 8 way suitable for single phase AC supply, 230 V sheet steel powder painted enclosure double door type with minimum IP-43 degree of protection with built in 200 Amps copperbus bar, neutral link and earth link complete including flush off in wall with cutting and making good the disturbed surface including connection of circuits with copper pin terminals complete all as specified and directed |
| 173 | S & F MCB SP 6-32 Amps, 240 Volts, C Series complete all as specified and directed.. |
| 174 | Supply and fixing MCB, single pole, upto 20Amp, 10KA, 230Volt. complete all as specified and as directed. |
| 175 | Taking down old unserviceable sub main cable of any size and capcity and finishing wall surfaces complete all as specified and directed. |
| 176 | Supply and fixing submain wiring with proper colour coding, 2 single core FRLS 1100 volts gradecable with stranded copper conductor of size 4 Sqmm in and including PVC Conduit/PVC casing caping of suitable size not less than 25 mm, ISI marked including 1 single core cable with stranded copper conductor of size 4 Sqmm (green colour) for earthingNote: (i) 2 runs of 4 Sqmm cable, 1 run of PVC Conduit/PVC casing caping and 1 run of 4 Sqmm cable shall be measured as 1 Run.(ii) Each Submain Wiring shall run in Seperate PVC Conduit/PVC casing caping. |
| 177 | Supply and fixing submain wiring with proper colour coding,2 single core FRLS 1100 volts gradecable with stranded copper conductor of size 6 Sqmm in and including PVC Conduit/PVC casing caping of suitable size not less than 25 mm, ISI marked including 1 single core cable with stranded copper conductor of size 6 Sqmm (green colour) for earthing.Note : (i) 2 runs of 6 Sqmm cable, 1 run of PVC Conduit/PVC casing caping and 1 run of 6 Sqmm cable shall be measured as 1 Run.(ii) Each Submain Wiring shall run in Seperate PVC Conduit/PVC casing caping. |
| 178 | S&F in replacement Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240Volts complete with metal clad socket including flush off in wall with cutting and making good the disturbed surface for window type air conditioners/geyser complete all as specified and directed. |
| 179 | Making round/ square hole cutting in wall with the help of cutting machine / chisel / hammer etc for fixing of exhaust fan of size 200 mm to 300 mm & making good to the distrubed surface including plaster, distumper, white wash complete all as specified and directed. |
| 180 | Supply and laying, commission XLPE insulated armoured LT cable, 110 Volts grade with aluminium conductor of size 2 core 16 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc complete all as specified and directed. |
| 181 | Supply and laying, commission XLPE insulated armoured LT cable, 110 Volts grade with aluminium conductor of size 2 core 16 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc complete all as specified and directed. |
| 182 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm sweep complete all as specified and directed by Engr in Charge. |
| 183 | Taking down existing split/window AC of any capacity from G+7 building alongwith accessories and kept in safe custoday and refix the same after repair of building in same location duly servicing complete includign filling of gas and replacement of minor parts i. filling of gas, copper tube pipe. drain pipe, insulation of pipes, fixing clamp, Bracket, nut bolts etc testing the same after installation complete all as specified and directed by Engr in Charge. |
| 184 | Note for all items above1)The tenderer shall note that before quoting his unit rates, all items of work shall be executed in a high-rise building (G + 7 floors) and shall include provision of necessary scaffolding and safety measures.2)Debris shall be removed from time to time as directed by the Engineer-in-Charge.3)Protective Work: Provision of temporary barricading using galvalume sheets around the periphery of the site up to a height of 5 m, complete all as specified and directed by the Engineer-in-Charge. |
| 185 | 4)Any damage caused to the RCC structure or adjoining portions during demolition or dismantling, due to negligence of the contractor, shall be made good by the contractor at his own expense.5)Safety Precaution: Necessary safety precautions for men, material and structures shall be taken by the contractor during execution of work.6)Necessary steel scaffolding shall be provided by the contractor for multistoried buildings. The contractor shall ensure that all workmen wear safety belts at all times.7)The work shall be carried out while the building remains partially occupied.8)Passenger lift shall not be made available for use by the contractor.9)The quoted rate for all items shall be deemed to include compliance with all the above conditions. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail