| 1 | Construction of sports room for Govt. Girl’s High School at Titilagarh under CSR 2025-26. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. and getting out in soft and loose soil and removing the same to a distance not exc. 50 and depositing where directed at a level not exc. 1.5m above the starting point. |
| 3 | Surface excavation not exc. 30cm deep and averaging 15cm deep and getting out in soft and loose soil. |
| 4 | Site Clearance not exc. 15cm depth in soft and loose soil, cutting of small bushes, levelling the ground including removal of the debris from the area as directed. |
| 5 | M & L for sand fillingunder floors or in foundations including watering and consolidation. |
| 6 | M & L for cement concrete in foundations, filling and mass concrete, Type B2 (1:2:4) using 40mm graded aggregate all as directed. |
| 7 | RCC (Design Mix M-20 using 20mm graded aggregates) in Foundations, including rafts, footings, foundatioin beams, plinth beams, bases for coloumns, etc. and mass concrete all as directed. |
| 8 | RCC (Design Mix M-20 using 20mm graded aggregates) in columns, pillars, piers, posts and struts etc. all as directed. |
| 9 | RCC (Design Mix M-20 using 20mm graded aggregates) in Beams, cantilevers, bressummers, lintels over 1.5m span all as directed. |
| 10 | RCC (Design Mix M-20 using 20mm graded aggregates) in Slab supported on walls, beams and columns in floor, roofs, landing, balconies canopies, deck slabs and in shelves and the like all as directed. |
| 11 | RCC (Design Mix M-20 using 20mm graded aggregates) in Chajjas all as directed. |
| 12 | Brickwork with fly ash bricks using modular bricks, straigh or curved on plan exc 6m mean radius, built in cement mortar (1:4) all as directed. |
| 13 | Fromwork to rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffit (if any) of foundation and plinth beams and similar work, vertical or to batterconcrete all as directed |
| 14 | Fromwork to rough finished surfaces of concrete soffits of suspended slabs such as roof slab, floor, landings and similar work not exceeding 200mm thick (Horizontal or sloping)all as directed. |
| 15 | Formwork to rough finished surfaces of concrete chullah hoods, chajja, troughs and similar items including edges or any rough finished surfaces of concrete. |
| 16 | Formwork to rough finished surfaces of concrete sides and soffits of floors ar roof beam, beam haunching, girders, bressumers, lintels, cantilebver, shelves including supports, overhang, etc. also splays between floors and beams, etc. on Rough finished surfaces. |
| 17 | Fromwork to rough finished surfaces of concrete sides of pillars, posts, struts, piers, columns and stanchions. |
| 18 | S & F of plain, solid, straight chowkats and frames, wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints, supplied and fixed |
| 19 | S & F of flush shutters (30mm thick), solid core construction, with block board core and plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match |
| 20 | Glazed and skeleton shutters of thickness 35mm in 1st class softwood, open rebated and prepared to receive glass, gluze etc. with sash bars, edges of framing plain, chemfered or rounded. Fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to choukats. |
| 21 | S & F of aluminium anodised, barrel tower bolts of size 200mm extruted section and fixed |
| 22 | S & F aluminium anodised, barrel tower bolts of size 150mm extruted section and fixed |
| 23 | S & F of mild steel sliding door bolt (300mm) plate type stove enamelled black with bright bolts not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed. |
| 24 | S & F of butt hinges (100mm), medium weight, cold rolled mild steel and fixed. |
| 25 | S & F of extruded aluminium alloy handles, fabricated type, anodised of size 150mm |
| 26 | S & F of extruded aluminium alloy handles, fabricated type, anodised of size 125mm |
| 27 | S & F of framed work such asgrills, gratings, etc. with ends of bars shoulders and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladder, framed balusters, walk ways,railing, frmework of water tanks and similar work conforming to Fe.290. Gde-E-165 all as directed |
| 28 | S & F of Band, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintel hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fast; all ties hooks for hanging fans; plains angle cleat for securing purlins; to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 29 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as directed. |
| 30 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia i stirrups, spacers and binder, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as directed. |
| 31 | M & L for providing cement concrete ofType B0 1:2:4 (12.5mm graded aggregate) in lintel upto 1.5m clear span, cills steps; seismic and other similar bands, plinth course, string course, lacingcourse, parapets and railing upto 60cm in height, coping, kneelers, apex stones beds plates, water troughs and the like includingweathering, slightly rounded or chamfered angles and throating. |
| 32 | M & L for providing cement concrete of thickness 100mm, type B-1, 1:2:4 (20mm graded aggregate) |
| 33 | M & L for non- skid Ceramic white tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as directed. |
| 34 | Rendering 12mm thick on fair faces of brick work or concrete surface in cement mortar (1:4) all as directed. |
| 35 | Rendering 05mm thick on fair faces of brick work or concrete surface in cement mortar (1:4) all as directed. |
| 36 | Screed bed or bedding layer of mortar 15mm thick for laying floor finishes |
| 37 | S & F of sheet glass of thickness 4.0 mm ordinary quality and glagingwith oil putty in square not exc 0.5 sqm in each pane. |
| 38 | M & L for preparation of new wood and wood based surfaces and applying two coat of synthetic enamel paint over a coat of primer. |
| 39 | M & L for preparation of new steel and iron surfaces and applying two coat of synthetic enamel paint over a coat of primer. |
| 40 | M & L for preparation of new wall surfaces and applying two coat of distemper oil emulsion over a coat of chalk whitining primer. |
| 41 | M & L for preparation of new ceiling surfaces and applying two coat of distemper oil emulsion over a coat of chalk whitining primer. |
| 42 | M & L for applying two or more coats of 100% Premium arcylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489;2004 Alkali & fungal resistance, sirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surface all as directed. |
| 43 | S & F 600mm x 600mm x 20mm thick granite stone (of any type) table rubbed, fixed over 20mm thick screed bed of cement mortar (1:4) and polished, grooving letters of any numbers and any symbles finished with golden colour. |
| 44 | Supply & fixing of 6 to 20 Amp rating,Single Pole, 240 V, 10KA \"C\" Curve miniature circuit breaker (MCB) in the existing MCB DB complete with connection, testing & commissioning.The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 45 | Supply & fixing of 25 Amp, 240 V, Double Pole Residual Current Circuit Breaker with Overcurrent Protection (RCBO) for earth leakage, overload & short-circuit protection with Sensitivity 30 mA in the existing MCB DB complete with connection, testing & commissioning. The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 46 | Labour for excavating trenches in hard/ dense soil not exceeding 1.5 m wide & not exceeding 1.5 m depth for laying of electrical power cable and getting earth out. |
| 47 | Labour for returningthe excavated earth in trench including spreading, levelling & well ramming in layers not exceeding 25 cm. |
| 48 | Cutting chases for concealed conduit wiring etc. and making good, cutting not exc 10 cm girth. |
| 49 | Material & Labour for Ceiling rose, 3 Phase/3 Pin, PVC/Polycarbonate, Isolated Body.The material to be used shall be of ISI marked and confirmning to relevant IS. |
| 50 | Supply & fixing of 1 x 20 Watt, 220 V AC, LED Light fittings with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make of LED Light fittings to be provided shall be of Phillips/Bajaj/Havells, Syska. |
| 51 | Supply & fixing LED Street Light fitting 60 Watt , 230 V AC Outdoor Type with High Pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact & corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 Protection Complete. It includes suitable GI bracket with accessories for fixing of street light. Make of LED Street Light fittings to be provided shall be of Phillips/Bajaj/Havells/Syska. |
| 52 | Supply & fixing of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mmsweep. Min air delivery 210 CFM with service value 6.00, BEE 5 Star Rated with Brushless Direct Current Motor (BLDC). The material to be supplied shall be of ISI marked & of reputed make like Atomberg, Bajaj, Surya, Orient, Havells, V-Guard etc. |
| 53 | Material & Labour for one light or one fan point wiring in PVC conduit with 1.5 sq.mm single core FRLS copper conductor cables to be controlled by one switch. The material to be used shall be of ISI marked and confirmning to relevant IS. |
| 54 | Material & Labour for circuit/submain wiring alongwith earth wire with 2 x 2.5 Sq. MM + 1 x 2.5 Sq. MM Earth Wire of FR PVC Insulated copper conductor, single core cable inPVC conduit in recessed or as required. The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 55 | Supply & fixing of modular switches 1 Way, 6 Amp, 1 Modulein the existing switch board including connectio & testing. The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 56 | Supplying & fixing of 2/3 Pin, 6 A, Combined Socket , 2 Module.The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 57 | Supply & fixing of modular switches 1 Way, 16 Amp, 1 Modulein the existing switch board including connectio & testing. The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 58 | Supplying & fixing of 2/3 Pin, 6 A/16A Combined Socket , 2 Module.The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 59 | Material & Labour for modular white cover plate with frame, 2 Module. The material to be used shall be of ISI marked or conforming to relevant IS & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 60 | Material & Labour for modular white cover plate with frame, 6 Module. The material to be used shall be of ISI marked or conforming to relevant IS & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 61 | Material & Labour for modular white cover plate with frame, 8 Module. The material to be used shall be of ISI marked or conforming to relevant IS & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 62 | Material & Labour for Modular Metal Flush Box, 2 Module. The material to be used shall be reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 63 | Material & Labour for Modular Metal Flush Box, 6 Module. The material to be used shall be reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 64 | Material & Labour for Modular Metal Flush Box, 8 Module. The material to be used shall be reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 65 | Material & Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduitpipe for loop earthing etc. as required with 4mm dia galvanized iron wire. |
| 66 | Demolition of unreinforced cement concrete of any description and in any position not otherwises specifically provided for. |
| 67 | M & L for providing of cement concrete of Type-C2 1:3:6 ( 20-40 MM) graded aggregate in repair against demolished cement concrete after laying of power cable. |
| 68 | M & L for32 MM Bore Dia High Density Polyethelenepipes (HDPE) of pressure rating 6 Kgf/cm2 laid in trenches. |
| 69 | Supply & laying or fixing or passing through pipe, 1100 Volts grade heavy duty cable with 4 core PVC insulated starnded aluminium conductor served with an inner sheathing of PVC tape armoured with galavanised steel wire or tape and overall PVC sheathed 10 Sq.MM nominal cross section in service connections. |
| 70 | Supplying & fixing cable route marker with 10 cm x 10 cm x 5 mm thick GI plate with inscription there on, bolted/welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in the ground as required. |
| 71 | Supplying & making end termination with brass compression gland and aluminium lugs for 4 Core 10 Sq. MM (25 MM) PVC Insulated and Sheathed aluminium conductor cable of 1.1 KV grade as required. |
| 72 | Laying of one number of PVC insulated and PVC sheathed power cable of 1.1 KV grade of size upto 35 Sq. MM in the existing HDPE/GI pipe. |
| 73 | Supplying & fixing of 6 way double door, single pole neutral sheet steel MCB distribution board, 240 V, on surface/recess, complete with neutral bus bar, earth bus bar, din rail, powder painted including interconnection, testing & earthin etc. as required. It includes wall cutting & making good the same for fixing of above MCB distribution board. The material to be used shall be reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 74 | Supplying & fixing single pole blanking plate in the existing MCB DB Complete etc. as required. |
| 75 | Material & Labour for earthing with GI earth Pipe of 4.5 Meter Long, 40 MM Dia Including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.This also includes earth excavation, earth pit chamber construction and earth refilling. |